Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 227
Filtrar
1.
J Biomech ; 170: 112127, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38781798

RESUMO

Abnormal postoperative global sagittal alignment (GSA) is associated with an increased risk of mechanical complications after spinal surgery. Typical assessment of sagittal alignment relies on a few selected measures, disregarding global complexity and variability of the sagittal curvature. The normative range of spinal loads associated with GSA has not yet been considered in clinical evaluation. The study objectives were to develop a new GSA assessment method that holistically describes the inherent relationships within GSA and to estimate the related spinal loads. Vertebral endplates were annotated on radiographs of 85 non-pathological subjects. A Principal Component Analysis (PCA) was performed to derive a Statistical Shape Model (SSM). Associations between identified GSA variability modes and conventional alignment measures were assessed. Simulations of respective Shape Modes (SMs) were performed using an established musculoskeletal AnyBody model to estimate normal variation in cervico-thoraco-lumbar loads. The first six principal components explained 97.96% of GSA variance. The SSM provides the normative range of GSA and a visual representation of the main variability modes. Normal variation relative to the population mean in identified alignment features was found to influence spinal loads, e.g. the lower bound of the second shape mode (SM2-2σ) corresponds to an increase in L4L5-compression by 378.64 N (67.86%). Six unique alignment features were sufficient to describe GSA almost entirely, demonstrating the value of the proposed method for an objective and comprehensive analysis of GSA. The influence of these features on spinal loads provides a normative biomechanical reference, eventually guiding surgical planning of deformity correction in the future.


Assuntos
Análise de Componente Principal , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Coluna Vertebral/fisiologia , Coluna Vertebral/diagnóstico por imagem , Suporte de Carga/fisiologia , Idoso , Vértebras Lombares/fisiologia , Vértebras Lombares/diagnóstico por imagem , Fenômenos Biomecânicos , Modelos Biológicos
2.
Mater Today Bio ; 26: 101060, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38711934

RESUMO

Cardiovascular diseases are a main cause of death worldwide, leading to a growing demand for medical devices to treat this patient group. Central to the engineering of such devices is a good understanding of the biology and physics of cell-surface interactions. In existing blood-contacting devices, such as vascular grafts, the interaction between blood, cells, and material is one of the main limiting factors for their long-term durability. An improved understanding of the material's chemical- and physical properties as well as its structure all play a role in how endothelial cells interact with the material surface. This review provides an overview of how different surface structures influence endothelial cell responses and what is currently known about the underlying mechanisms that guide this behavior. The structures reviewed include decellularized matrices, electrospun fibers, pillars, pits, and grated surfaces.

3.
Front Bioeng Biotechnol ; 12: 1355723, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38807649

RESUMO

Introduction: Osteoarthritis (OA) and rotator cuff tear (RCT) pathologies have distinct scapular morphologies that impact disease progression. Previous studies examined the correlation between scapular morphology and glenohumeral joint biomechanics through critical shoulder angle (CSA) variations. In abduction, higher CSAs, common in RCT patients, increase vertical shear force and rotator cuff activation, while lower CSAs, common in OA patients, are associated with higher compressive force. However, the impact of the complete patient-specific scapular morphology remains unexplored due to challenges in establishing personalized models. Methods: CT data of 48 OA patients and 55 RCT patients were collected. An automated pipeline customized the AnyBody™ model with patient-specific scapular morphology and glenohumeral joint geometry. Biomechanical simulations calculated glenohumeral joint forces and instability ratios (shear-to-compressive forces). Moment arms and torques of rotator cuff and deltoid muscles were analyzed for each patient-specific geometry. Results and discussion: This study confirms the increased instability ratio on the glenohumeral joint in RCT patients during abduction (mean maximum is 32.80% higher than that in OA), while OA patients exhibit a higher vertical instability ratio in flexion (mean maximum is 24.53% higher than that in RCT) due to the increased inferior vertical shear force. This study further shows lower total joint force in OA patients than that in RCT patients (mean maximum total force for the RCT group is 11.86% greater than that for the OA group), attributed to mechanically advantageous muscle moment arms. The findings highlight the significant impact of the glenohumeral joint center positioning on muscle moment arms and the total force generated. We propose that the RCT pathomechanism is related to force magnitude, while the OA pathomechanism is associated with the shear-to-compressive loading ratio. Overall, this research contributes to the understanding of the impact of the complete 3D scapular morphology of the individual on shoulder biomechanics.

4.
J Mech Behav Biomed Mater ; 155: 106579, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38749266

RESUMO

Silicon nitride is utilized clinically as a bioceramic for spinal fusion cages, owing to its high strength, osteoconductivity, and antibacterial effects. Nevertheless, silicon nitride exhibits suboptimal damping properties, a critical factor in mitigating traumatic bone injuries and fractures. In fact, there is a scarcity of spinal implants that simultaneously demonstrate proficient damping performance and support osteogenesis. In our study, we fabricated a novel sodium alginate-silicon nitride/poly(vinyl alcohol) (SA-SiN/PVA) composite scaffold, enabling enhanced energy absorption and rapid elastic recovery under quasi-static and impact loading scenarios. Furthermore, the study demonstrated that the incorporation of physical and chemical cross-linking significantly improved stiffness and recoverable energy dissipation. Concerning the interaction between cells and materials, our findings suggest that the addition of silicon nitride stimulated osteogenic differentiation while inhibiting Staphylococcus aureus growth. Collectively, the amalgamation of ceramics and tough hydrogels facilitates the development of advanced composites for spinal implants, manifesting superior damping, osteogenic potential, and antibacterial properties. This approach holds broader implications for applications in bone tissue engineering.


Assuntos
Alginatos , Materiais Biocompatíveis , Teste de Materiais , Álcool de Polivinil , Compostos de Silício , Staphylococcus aureus , Alginatos/química , Alginatos/farmacologia , Álcool de Polivinil/química , Compostos de Silício/química , Compostos de Silício/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Antibacterianos/farmacologia , Antibacterianos/química , Osteogênese/efeitos dos fármacos , Fenômenos Mecânicos , Alicerces Teciduais/química , Humanos
5.
J Biomech ; 168: 112039, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38657434

RESUMO

Musculoskeletal simulations with muscle optimization aim to minimize muscle effort, hence are considered unable to predict the activation of antagonistic muscles. However, activation of antagonistic muscles might be necessary to satisfy the dynamic equilibrium. This study aims to elucidate under which conditions coactivation can be predicted, to evaluate factors modulating it, and to compare the antagonistic activations predicted by the lumbar spine model with literature data. Simple 2D and 3D models, comprising of 2 or 3 rigid bodies, with simple or multi-joint muscles, were created to study conditions under which muscle coactivity is predicted. An existing musculoskeletal model of the lumbar spine developed in AnyBody was used to investigate the effects of modeling intra-abdominal pressure (IAP), linear/cubic and load/activity-based muscle recruitment criterion on predicted coactivation during forward flexion and lateral bending. The predicted antagonist activations were compared to reported EMG data. Muscle coactivity was predicted with simplified models when multi-joint muscles were present or the model was three-dimensional. During forward flexion and lateral bending, the coactivation ratio predicted by the model showed good agreement with experimental values. Predicted coactivation was negligibly influenced by IAP but substantially reduced with a force-based recruitment criterion. The conditions needed in multi-body models to predict coactivity are: three-dimensionality or multi-joint muscles, unless perfect antagonists. The antagonist activations are required to balance 3D moments but do not reflect other physiological phenomena, which might explain the discrepancies between model predictions and experimental data. Nevertheless, the findings confirm the ability of the multi-body trunk models to predict muscle coactivity and suggest their overall validity.


Assuntos
Modelos Biológicos , Músculo Esquelético , Humanos , Músculo Esquelético/fisiologia , Tronco/fisiologia , Vértebras Lombares/fisiologia , Contração Muscular/fisiologia , Eletromiografia , Simulação por Computador , Fenômenos Biomecânicos
6.
Osteoporos Int ; 35(7): 1231-1241, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38658459

RESUMO

There is imminent refracture risk in elderly individuals for up to six years, with a decline thereafter except in women below 75 who face a constant elevated risk. Elderly men with fractures face the highest mortality risk, particularly those with hip and vertebral fractures. Targeted monitoring and treatment strategies are recommended. PURPOSE: Current management and interventions for osteoporotic fractures typically focus on bone mineral density loss, resulting in suboptimal evaluation of fracture risk. The aim of the study is to understand the progression of fractures to refractures and mortality in the elderly using multi-state models to better target those at risk. METHODS: This prospective, observational study analysed data from the AGES-Reykjavik cohort of Icelandic elderly, using multi-state models to analyse the evolution of fractures into refractures and mortality, and to estimate the probability of future events in subjects based on prognostic factors. RESULTS: At baseline, 4778 older individuals aged 65 years and older were included. Elderly men, and elderly women above 80 years of age, had a distinct imminent refracture risk that lasted between 2-6 years, followed by a sharp decline. However, elderly women below 75 continued to maintain a nearly constant refracture risk profile for ten years. Hip (30-63%) and vertebral (24-55%) fractures carried the highest 5-year mortality burden for elderly men and women, regardless of age, and for elderly men over 80, lower leg fractures also posed a significant mortality risk. CONCLUSION: The risk of refracture significantly increases in the first six years following the initial fracture. Elderly women, who experience fractures at a younger age, should be closely monitored to address their long-term elevated refracture risk. Elderly men, especially those with hip and vertebral fractures, face substantial mortality risk and require prioritized monitoring and treatment.


Assuntos
Fraturas do Quadril , Fraturas por Osteoporose , Recidiva , Fraturas da Coluna Vertebral , Humanos , Fraturas por Osteoporose/mortalidade , Idoso , Masculino , Feminino , Islândia/epidemiologia , Idoso de 80 Anos ou mais , Fraturas do Quadril/mortalidade , Fraturas da Coluna Vertebral/mortalidade , Estudos Prospectivos , Medição de Risco/métodos , Progressão da Doença , Densidade Óssea/fisiologia , Prognóstico
7.
Trends Biotechnol ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38658198

RESUMO

Advances in tissue engineering for both system modeling and organ regeneration depend on embracing and recapitulating the target tissue's functional and structural complexity. Microenvironmental features such as anisotropy, heterogeneity, and other biochemical and mechanical spatiotemporal cues are essential in regulating tissue development and function. Novel biofabrication strategies and innovative biomaterial design have emerged as promising tools to better reproduce such features. These facilitate a transition towards high-fidelity biomimetic structures, offering opportunities for a deeper understanding of tissue function and the development of superior therapies. In this review, we explore some of the key structural and compositional aspects of tissues, lay out how to achieve similar outcomes with current fabrication strategies, and identify the main challenges and promising avenues for future research.

8.
Artigo em Inglês | MEDLINE | ID: mdl-38642877

RESUMO

BACKGROUND: Tendon transfers are established techniques to regain external rotation mobility in patients suffering from an irreparable, posterosuperior massive rotator cuff tear (MRCT). Posterosuperior MRCT with intact teres minor (Type D MRCT) can lead to excessive teres minor loading to maintain external rotation. We hypothesize that tendon transfers are effective in relieving teres minor loading in Type D MRCTs. Our aim was to biomechanically assess muscle synergism with latissimus dorsi (LD-Transfer) and lower trapezius (LT-Transfer) tendon transfer during external rotation at different abduction heights. METHODS: Using musculoskeletal modeling, we analyzed and compared the moment arm, muscle torque and muscle activity between a healthy and Type D MRCT pathological model with and without the LD- or LT-Transfer at infraspinatus and teres minor insertion sites. Output measures were analyzed during external rotation at different abduction angles and 10 to 50N resistance against external rotation. We assessed its impact on teres minor loading in a Type D MRCT. Morphological variations were parameterized using the critical shoulder angle and the acromiohumeral distance to address variations among patients. RESULTS: Both transfer types reduced teres minor torque and activity significantly, reaching physiological state at 40N external resistance (p<0.001), with insertion to infraspinatus site being more effective than teres minor site (p<0.001). External rotation moment arms of LD-Transfer were larger than LT-Transfer at 90° abduction (25.1±0.8mm vs. 21.2±0.6mm, p<0.001) and vice versa at 0° abduction (17.4±0.5mm vs. 24.0±0.2mm, p<0.001). While the healthy infraspinatus was the main external rotator in all abduction angles (50-70% torque), a Type D MRCT resulted in a 70-90% increase of teres minor torque and an up to sevenfold increase in its activity leading to excessive loadings beyond 10N resistance against external rotation. Varying the critical shoulder angle and the acromiohumeral distance led to minor variations in muscle moment arm and muscle activity. CONCLUSION: We identified biomechanical efficacy of both tendon transfers in Type D MRCT regarding teres minor load relieve and superior performance of the transfers at the infraspinatus insertion site.

9.
Osteoporos Int ; 35(6): 971-996, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38353706

RESUMO

The use of opportunistic computed tomography (CT) image-based biomarkers may be a low-cost strategy for screening older individuals at high risk for osteoporotic fractures and populations that are not sufficiently targeted. This review aimed to assess the discriminative ability of image-based biomarkers derived from existing clinical routine CT scans for hip, vertebral, and major osteoporotic fracture prediction. A systematic search in PubMed MEDLINE, Embase, Cochrane, and Web of Science was conducted from the earliest indexing date until July 2023. The evaluation of study quality was carried out using a modified Quality Assessment Tool for Diagnostic Accuracy Studies (QUADAS-2) checklist. The primary outcome of interest was the area under the curve (AUC) and its corresponding 95% confidence intervals (CIs) obtained for four main categories of biomarkers: areal bone mineral density (BMD), image attenuation, volumetric BMD, and finite element (FE)-derived biomarkers. The meta-analyses were performed using random effects models. Sixty-one studies were included in this review, among which 35 were synthesized in a meta-analysis and the remaining articles were qualitatively synthesized. In comparison to the pooled AUC of areal BMD (0.73 [95% CI 0.71-0.75]), the pooled AUC values for predicting osteoporotic fractures for FE-derived parameters (0.77 [95% CI 0.72-0.81]; p < 0.01) and volumetric BMD (0.76 [95% CI 0.71-0.81]; p < 0.01) were significantly higher, but there was no significant difference with the pooled AUC for image attenuation (0.73 [95% CI 0.66-0.79]; p = 0.93). Compared to areal BMD, volumetric BMD and FE-derived parameters may provide a significant improvement in the discrimination of osteoporotic fractures using opportunistic CT assessments.


Assuntos
Biomarcadores , Densidade Óssea , Fraturas por Osteoporose , Tomografia Computadorizada por Raios X , Humanos , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/fisiopatologia , Densidade Óssea/fisiologia , Tomografia Computadorizada por Raios X/métodos , Biomarcadores/sangue , Programas de Rastreamento/métodos , Fraturas da Coluna Vertebral/fisiopatologia , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/fisiopatologia , Análise de Elementos Finitos
10.
Comput Methods Programs Biomed ; 245: 108009, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38219339

RESUMO

BACKGROUND AND OBJECTIVE: The accurate evaluation of bone mechanical properties is essential for predicting fracture risk based on clinical computed tomography (CT) images. However, blurring and noise in clinical CT images can compromise the accuracy of these predictions, leading to incorrect diagnoses. Although previous studies have explored enhancing trabecular bone CT images to super-resolution (SR), none of these studies have examined the possibility of using clinical CT images from different instruments, typically of lower resolution, as a basis for analysis. Additionally, previous studies rely on 2D SR images, which may not be sufficient for accurate mechanical property evaluation, due to the complex nature of the 3D trabecular bone structures. The objective of this study was to address these limitations. METHODS: A workflow was developed that utilizes convolutional neural networks to generate SR 3D models across different clinical CT instruments. The morphological and finite-element-derived mechanical properties of these SR models were compared with ground truth models obtained from micro-CT scans. RESULTS: A significant improvement in analysis accuracy was demonstrated, where the new SR models increased the accuracy by up to 700 % compared with the low-resolution data, i.e. clinical CT images. Additionally, we found that the mixture of different CT image datasets may improve the SR model performance. CONCLUSIONS: SR images, generated by convolutional neural networks, outperformed clinical CT images in the determination of morphological and mechanical properties. The developed workflow could be implemented for fracture risk prediction, potentially leading to improved diagnoses and subsequent clinical decision making.


Assuntos
Processamento de Imagem Assistida por Computador , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Osso e Ossos , Osso Esponjoso
11.
J Mech Behav Biomed Mater ; 150: 106333, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38134586

RESUMO

The fibro-cartilaginous labrum surrounds the acetabular rim and is important for hip joint stability and sealing. Sealing may be enhanced by swelling pressure within the normal labrum. Swelling of the degenerated or torn labrum might occur and potentially contribute to the development of osteoarthritis, through altered load transmission. This study aimed to characterize the three-dimensional swelling behaviour, the collagen fiber orientation and spatial proteoglycan distribution of the bovine acetabular labrum. Specimens were harvested from bovine donors (192-652 days, male, n = 6 donors). Structure was analyzed by scanning electron microscopy, histology, and dimethylmethylene blue assay. Specimen dimensions were measured before and after incubation in phosphate buffered saline to assess the swelling. Results showed that the articulating surface is composed of a collagen mesh network. Collagen fiber bundles showed a low degree of alignment close to the surface and were circumferentially aligned in the deep tissue. Proteoglycans were identified clustered between the collagen bundles. Glycosaminoglycan content was 10 x lower than that of cartilage (23.1 ± 6.4 compared to 299.5 ± 19.1 µg/mg dry weight) with minor regional differences. Specimens swelled significantly more in the orthogonal direction (swelling ratio 124.7 ± 10.2%) compared to the swelling parallel to the articulating surface (108.8 ± 6.1% and 102.8 ± 4.1%). In the deep tissue, swelling was also restricted in the main collagen fiber bundle direction (circumferentially), with a swelling ratio of 109.5 ± 4.0% in the main fiber bundle direction compared to 126.8 ± 7.3 % and 122.3 ± 5.8% radially. The findings demonstrate that the labrum shows anisotropic swelling properties, which reflect the anisotropy in the tissue structure and inter-fiber localisation of proteoglycans.


Assuntos
Acetábulo , Cartilagem Articular , Masculino , Animais , Bovinos , Anisotropia , Cartilagem Articular/patologia , Articulação do Quadril , Colágeno , Proteoglicanas
12.
Sci Rep ; 13(1): 21531, 2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38057609

RESUMO

Considerable research has been focused on identifying the optimum biomaterial for spine implants. New technologies and materials have allowed surgeons to better grasp the biomechanical principles underpinning implant stability and function. An optimal biomaterial for total disc replacement (TDR) should include essential characteristics such as biocompatibility, long-term durability, the capacity to withstand mechanical stresses, and economic viability. Our research has focused on six biomaterials for TDR, including Ti-6Al-4V, CoCr alloy, stainless steel 316L, zirconia toughened alumina (ZTA), polyether ether ketone (PEEK) and ultra-high-molecular weight polyethylene (UHMWPE). Ten common properties, i.e., the Young's modulus, density, tensile strength, the expense of the manufacturing process, the cost of raw material, wear rate, corrosion resistance, thermal conductivity, fracture toughness and compressive strength were utilized to assess these six different materials. The purpose of this study was to evaluate and rank the six alternative biomaterials proposed for use in the endplates and articulating surface of a spinal TDR. To accomplish this, a multi-criteria decision-making approach, namely the fuzzy analytic hierarchy process (fuzzy AHP) and the Technique of Order Preference by Similarity to Ideal Solution (TOPSIS) was adopted to solve the model. For validation and robustness of the proposed method, sensitivity analysis was performed, and comparison was performed with fuzzy-VIKOR and fuzzy-MOORA methods. In light of the study's results, ZTA and Ti-6Al-4V were identified as the best suited materials for the articulating surface and endplates, respectively, in a spinal disc implant.


Assuntos
Processo de Hierarquia Analítica , Materiais Biocompatíveis , Próteses e Implantes , Coluna Vertebral/cirurgia , Ligas , Tomada de Decisões , Titânio , Teste de Materiais
14.
Biomater Adv ; 154: 213617, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37678088

RESUMO

Despite the recent advances in 3D-printing, it is often difficult to fabricate implants that optimally fit a defect size or shape. There are some approaches to resolve this issue, such as patient-specific implant/scaffold designs based on CT images of the patients, however, this process is labor-intensive and costly. Especially in developing countries, affordable treatment options are required, while still not excluding these patient groups from potential material and manufacturing advances. Here, a selective laser melting (SLM) 3D-printing strategy was used to fabricate a hierarchical, LEGO®-inspired Assemblable Titanium Scaffold (ATS) system, which can be manually assembled in any shape or size with ease. A surgeon can quickly create a scaffold that would fit to the defect right before the implantation during the surgery. Additionally, the direct inclusion of micro- and macroporous structures via 3D-printing, as well as a double acid-etched surface treatment (ST) in the ATS, ensure biocompatibility, sufficient nutrient flow, cell migration and enhanced osteogenesis. Three different structures were designed (non-porous:NP, semi-porous:SP, ultra-porous:UP), 3D-printed with the SLM technique and then surface treated for the ST groups. After analyzing characteristics of the ATS such as printing quality, surface roughness and interconnected porosity, mechanical testing and finite element analysis (FEA) demonstrated that individual and stacked ATS have sufficient mechanical properties to withstand loading in a physiological system. All ATS showed high cell viability, and the SP and UP groups demonstrated enhanced cell proliferation rates compared to the NP group. Furthermore, we also verified that cells were well-attached and spread on the porous structures and successful cell migration between the ATS units was seen in the case of assemblies. The UP and SP groups exhibited higher calcium deposition and RT-qPCR proved higher osteogenic gene expression compared to NP group. Finally, we demonstrate a number of possible medical applications that reveal the potential of the ATS through assembly.


Assuntos
Medicina Regenerativa , Titânio , Humanos , Osteogênese , Próteses e Implantes , Impressão Tridimensional
15.
J Biomech Eng ; 145(12)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37773639

RESUMO

Intervertebral disc (IVD) degeneration and methods for repair and regeneration have commonly been studied in organ cultures with animal IVDs under compressive loading. With the recent establishment of a novel multi-axial organ culture system, accurate predictions of the global and local mechanical response of the IVD are needed for control system development and to aid in experiment planning. This study aimed to establish a finite element model of bovine IVD capable of predicting IVD behavior at physiological and detrimental load levels. A finite element model was created based on the dimensions and shape of a typical bovine IVD used in the organ culture. The nucleus pulposus (NP) was modeled as a neo-Hookean poroelastic material and the annulus fibrosus (AF) as a fiber-reinforced poroviscoelastic material. The AF consisted of 10 lamella layers and the material properties were distributed in the radial direction. The model outcome was compared to a bovine IVD in a compressive stress-relaxation experiment. A parametric study was conducted to investigate the effect of different material parameters on the overall IVD response. The model was able to capture the equilibrium response and the relaxation response at physiological and higher strain levels. Permeability and elastic stiffness of the AF fiber network affected the overall response most prominently. The established model can be used to evaluate the response of the bovine IVD at strain levels typical for organ culture experiments, to define relevant boundaries for such studies, and to aid in the development and use of new multi-axial organ culture systems.

16.
ACS Appl Bio Mater ; 6(8): 3319-3329, 2023 08 21.
Artigo em Inglês | MEDLINE | ID: mdl-37561906

RESUMO

The issue of spine-related disorders is a global healthcare concern that requires effective solutions to restore normal spine functioning. Spinal fusion implants have become a standard approach for this purpose, making it crucial to develop biomaterials and structures that possess high osteogenic capacities and exhibit mechanical properties and dynamic responses similar to those of the host bone. This study focused on the fabrication of 3D-printed polyether ether ketone/silicon nitride (PEEK/SiN) scaffolds with a triply periodic minimal surface (TPMS) structure, which offers several advantages, such as a large surface area and uniform stress distribution under load. The mechanical properties and dynamic response of PEEK/SiN scaffolds with varying porosities were evaluated through mechanical testing and finite element analysis. The scaffold with 30% porosity exhibited a compressive strength (34.56 ± 1.91 MPa) and elastic modulus (734 ± 64 MPa) similar to those of trabecular bone. In addition, the scaffold demonstrated favorable damping properties. The biological data revealed that incorporating silicon nitride into the PEEK scaffold stimulated osteogenic differentiation. In light of these findings, it can be inferred that PEEK/SiN TPMS scaffolds exhibit significant potential for use in bone tissue engineering and represent a promising option as candidates for spinal fusion implants.


Assuntos
Osteogênese , Fusão Vertebral , Teste de Materiais , Polietilenoglicóis/química , Cetonas/química , Impressão Tridimensional
17.
Adv Mater ; 35(44): e2302008, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37632210

RESUMO

Advances in additive manufacturing have led to diverse patient-specific implant designs utilizing computed tomography, but this requires intensive work and financial implications. Here, Digital Light Processing is used to fabricate a hive-structured assemblable bespoke scaffold (HIVE). HIVE can be manually assembled in any shape/size with ease, so a surgeon can create a scaffold that will best fit a defect before implantation. Simultaneously, it can have site-specific treatments by working as a carrier filled with microcryogels (MC) incorporating different biological factors in different pockets of HIVE. After characterization, possible site-specific applications are investigated by utilizing HIVE as a versatile carrier with incorporated treatments such as growth factors (GF), bioceramic, or cells. HIVE as a GF-carrier shows a controlled release of bone morphogenetic protein/vascular endothelial growth factor (BMP/VEGF) and induced osteogenesis/angiogenesis from human mesenchymal stem cells (hMSC)/human umbilical vein endothelial cells (HUVECs). Furthermore, as a bioceramic-carrier, HIVE demonstrates enhanced mineralization and osteogenesis, and as a HUVEC carrier, it upregulates both osteogenic and angiogenic gene expression of hMSCs. HIVE with different combinations of MCs yields a distinct local effect and successful cell migration is confirmed within assembled HIVEs. Finally, an in vivo rat subcutaneous implantation demonstrates site-specific osteogenesis and angiogenesis.


Assuntos
Medicina Regenerativa , Alicerces Teciduais , Humanos , Ratos , Animais , Fator A de Crescimento do Endotélio Vascular/genética , Fator A de Crescimento do Endotélio Vascular/metabolismo , Osteogênese , Células Endoteliais da Veia Umbilical Humana/metabolismo , Impressão Tridimensional , Engenharia Tecidual/métodos , Regeneração Óssea
18.
Bioengineering (Basel) ; 10(7)2023 Jun 27.
Artigo em Inglês | MEDLINE | ID: mdl-37508797

RESUMO

Osteoarthritis scaffold-based grafts fail because of poor integration with the surrounding soft tissue and inadequate tribological properties. To circumvent this, we propose electrospun poly(ε-caprolactone)/zein-based scaffolds owing to their biomimetic capabilities. The scaffold surfaces were characterized using Fourier-transform infrared spectroscopy, X-ray photoelectron spectroscopy, static water contact angles, and profilometry. Scaffold biocompatibility properties were assessed by measuring protein adsorption (Bicinchoninic Acid Assay), cell spreading (stained F-actin), and metabolic activity (PrestoBlue™ Cell Viability Reagent) of primary bovine chondrocytes. The data show that zein surface segregation in the membranes not only completely changed the hydrophobic behavior of the materials, but also increased the cell yield and metabolic activity on the scaffolds. The surface segregation is verified by the infrared peak at 1658 cm-1, along with the presence and increase in N1 content in the survey XPS. This observation could explain the decrease in the water contact angles from 125° to approximately 60° in zein-comprised materials and the decrease in the protein adsorption of both bovine serum albumin and synovial fluid by half. Surface nano roughness in the PCL/zein samples additionally benefited the radial spreading of bovine chondrocytes. This study showed that co-electrospun PCL/zein scaffolds have promising surface and biocompatibility properties for use in articular-tissue-engineering applications.

19.
Sports (Basel) ; 11(7)2023 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-37505612

RESUMO

Velocity-based training (VBT) is a method to monitor resistance training based on measured kinematics. Often, measurement devices are too expensive for non-professional use. The purpose of this study was to determine the accuracy and precision of the Apple Watch 7 and the Enode Pro device for measuring mean, peak, and propulsive velocity during the free-weighted back squat (in comparison to Vicon as the criterion). Velocity parameters from Vicon optical motion capture and the Apple Watch were derived by processing the motion data in an automated Python workflow. For the mean velocity, the barbell-mounted Apple Watch (r = 0.971-0.979, SEE = 0.049), wrist-worn Apple Watch (r = 0.952-0.965, SEE = 0.064) and barbell-mounted Enode Pro (r = 0.959-0.971, SEE = 0.059) showed an equal level of validity. The barbell-mounted Apple Watch (Vpeak: r = 0.952-0.965, SEE = 0.092; Vprop: r = 0.973-0.981, SEE = 0.05) was found to be the most valid for assessing propulsive and peak lifting velocity. The present results on the validity of the Apple Watch are very promising, and may pave the way for the inclusion of VBT applications in mainstream consumer wearables.

20.
Clin Biomech (Bristol, Avon) ; 107: 106030, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37413811

RESUMO

BACKGROUND: Compromised abduction ability after reverse shoulder arthroplasty is primarily linked to limited glenohumeral range of motion while scapulothoracic mobility can typically be maintained. Glenohumeral joint forces strongly depend on the resulting scapulohumeral rhythm, however, an association between the acting muscle and joint forces and the subject-specific scapulohumeral rhythm after reverse shoulder arthroplasty has not been established. METHODS: Eleven reverse shoulder arthroplasty patients were divided into groups of poor and excellent abduction ability. Subject-specific models were developed and scaled for each patient using existing motion capture data in AnyBody™. Shoulder muscle and joint forces were obtained using inverse dynamics calculations during shoulder abduction to 100° in the scapula plane. The scapulohumeral rhythm, the resting abduction angle and internal body forces between the outcome groups were compared using a Mann Whitney U test. FINDINGS: The mean glenohumeral and scapulothoracic contribution to overall shoulder abduction for the excellent group was on average 9.7% higher and 21.4% lower, respectively, compared to the mean of the poor group. For shoulder abduction angles between 30° and 60°, the excellent group demonstrated on average 25% higher muscle forces in the anterior deltoid which was significantly higher compared to the poor outcome patients. Scapulothoracic muscle activity did not differ significantly between the two functional groups. INTERPRETATION: Accordingly, rehabilitation strategies focusing on strengthening the anterior part of the deltoid in particular may improve clinical outcomes.


Assuntos
Artroplastia do Ombro , Articulação do Ombro , Humanos , Ombro/fisiologia , Fenômenos Biomecânicos/fisiologia , Escápula/cirurgia , Escápula/fisiologia , Músculo Esquelético/cirurgia , Amplitude de Movimento Articular/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...