Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Clin Res Cardiol ; 113(2): 223-234, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37368015

RESUMO

INTRODUCTION AND OBJECTIVES: Vaccines against SARS-CoV-2 have been a major scientific and medical achievement in the control of the COVID-19 pandemic. However, very infrequent cases of inflammatory heart disease have been described as adverse events, leading to uncertainty in the scientific community and in the general population. METHODS: The Vaccine-Carditis Registry has included all cases of myocarditis and pericarditis diagnosed within 30 days after COVID-19 vaccination since August 1, 2021 in 29 centers throughout the Spanish territory. The definitions of myocarditis (probable or confirmed) and pericarditis followed the consensus of the Centers for Disease Control and the Clinical Practice Guidelines of the European Society of Cardiology. A comprehensive analysis of clinical characteristics and 3-month evolution is presented. RESULTS: From August 1, 2021, to March 10, 2022, 139 cases of myocarditis or pericarditis were recorded (81.3% male, median age 28 years). Most cases were detected in the 1st week after administration of an mRNA vaccine, the majority after the second dose. The most common presentation was mixed inflammatory disease (myocarditis and pericarditis). 11% had left ventricular systolic dysfunction, 4% had right ventricular systolic dysfunction, and 21% had pericardial effusion. In cardiac magnetic resonance studies, left ventricular inferolateral involvement was the most frequent pattern (58%). More than 90% of cases had a benign clinical course. After a 3-month follow-up, the incidence of adverse events was 12.78% (1.44% mortality). CONCLUSIONS: In our setting, inflammatory heart disease after vaccination against SARS-CoV-2 predominantly affects young men in the 1st week after the second dose of RNA-m vaccine and presents a favorable clinical course in most cases.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Miocardite , Pericardite , Adulto , Feminino , Humanos , Masculino , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Progressão da Doença , Miocardite/induzido quimicamente , Miocardite/epidemiologia , Pericardite/induzido quimicamente , Pericardite/epidemiologia , Sistema de Registros , Vacinação/efeitos adversos , Espanha
2.
JACC Case Rep ; 4(11): 655-657, 2022 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-35677793

RESUMO

Catheter ablation has become the cornerstone of the treatment of ventricular arrythmias. Nevertheless, it is crucial to recognize the adverse effects of such treatment. We present a case of an incidental diagnosis of ventricular pseudoaneurysms after catheter ablation for treatment of drug-refractory nonsustained runs of ventricular tachycardia. (Level of Difficulty: Advanced.).

3.
Cardiol J ; 27(6): 789-796, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31106841

RESUMO

BACKGROUND: Left ventricular (LV) mechanics are impaired in patients with severe aortic stenosis (AS); however, transcatheter aortic valve implantation (TAVI) may positively affect LV mechanics. Assessed herein is the performance of the SAPIEN 3 transcatheter heart valve (THV) and the effect of TAVI on LV function recovery, as assessed by global longitudinal strain (GLS). METHODS: A subset of patients from the SOURCE 3 registry (n = 276) from 16 European centers received SAPIEN 3 balloon-expandable THV. Echocardiography was performed at baseline, postprocedure, and at 1 year, including assessment of GLS using standard two-dimensional images, and was analyzed in a core laboratory. Paired analyses between baseline and discharge, baseline and at 1 year were conducted. RESULTS: Hemodynamic parameters were improved after TAVI and sustained to 1 year. At 1 year, the rate of moderate to severe paravalvular leaks (PVL), and moderate to severe mitral and tricuspid regurgitations were 1.8%, 1.7%, and 8.0%, respectively. The discharge GLS (-15.6 ± 5.1; p = 0.004; n = 149) improved significantly from baseline (-15.1 ± 4.8) following TAVI. This improvement was sustained at 1 year compared with baseline (-17.0 ± 4.6, p < 0.001; n = 100). Conversely, LV ejection fraction (LVEF) did not significantly change following TAVI (p = 0.47). CONCLUSIONS: Following TAVI with a third-generation THV, valve performances were good at 1 year with low PVL rate. The LV mechanics improved immediately after the procedure and were maintained at 1 year. These findings demonstrate the benefit of TAVI on LV mechanics, and suggests that GLS may be superior to LVEF in assessing this benefit. Clinicaltrial.gov number: NCT02698956.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
4.
Cardiology ; 143(1): 52-61, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31307038

RESUMO

PURPOSE: Left ventricular (LV) mechanics are impaired in patients with severe aortic stenosis (AS). Transcatheter aortic valve replacement (TAVR) has become a widespread technique for patients with severe AS considered inoperable or high risk for open surgery. This procedure could have a positive impact in LV mechanics. The aim of the study was to evaluate the effect of TAVR on LV function recovery, as assessed by myocardial deformation parameters, both immediately and in the long term. METHODS: One-hundred nineteen consecutive patients (81.2 ± 6.9 years, 50.4% female) from 10 centres in Europe with severe AS who successfully underwent TAVR with either a self-expanding CoreValve (Medtronic, Minneapolis, MN, USA) or a mechanically expanded Lotus valve (Boston Scientific, Natick, MA, USA) were enrolled in a prospective observational study. A complete echocardiographic examination was performed prior to device implantation, before discharge and 1 year after the procedure, including the assessment of LV strain using standard 2D images. RESULTS: Between baseline and discharge, only a modest but statistically significant improvement in GLS (global longitudinal strain) could be seen (GLS% -14.6 ± 5.0 at baseline; -15.7 ± 5.1 at discharge, p = 0.0116), although restricted to patients in the CoreValve group; 1 year after the procedure, a greater improvement in GLS was observed (GLS% -17.1 ± 4.9, p < 0.001), both in the CoreValve and the Lotus groups. CONCLUSIONS: Immediate and sustained improvement in GLS was appreciated after the TAVR procedure. Whether this finding continues to be noted in a more prolonged follow-up and its clinical implications need to be assessed in further studies.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda/terapia , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Ecocardiografia , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos , Disfunção Ventricular Esquerda/etiologia
5.
Cardiol J ; 25(4): 487-494, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29924376

RESUMO

BACKGROUND: Left ventricular (LV) mechanics are impaired in patients with severe aortic stenosis (AS). Transcatheter aortic valve replacement (TAVR) has become a widespread technique for patients with severe AS considered inoperable or high risk for traditional open-surgery. This procedure could have a positive impact in LV mechanics. The aim of this study was to evaluate the immediate effect of TAVR on LV function recovery, as assessed by myocardial deformation parameters. METHODS: One-hundred twelve consecutive patients (81.4 ± 6.4 years, 50% female) from 10 centres in Europe with severe AS who successfully underwent TAVR with either a self-expanding CoreValve (Medtronic, Minneapolis, MN) or a mechanically expanded Lotus valve (Boston Scientific, Natick, MA) were enrolled in a prospective multi-center study. A complete echocardiographic examination was performed at baseline and immediately before discharge, including the assessment of LV strain using standard two-dimensional images. RESULTS: Echocardiographic examination with global longitudinal strain (GLS) quantification could be obtained in 92 patients, because of echocardiographic and logistic reasons. Between examinations, a modest statistically significant improvement in GLS could be seen (GLS% -15.00 ± 4.80 at baseline;-16.15 ± 4.97 at discharge, p = 0.028). In a stratified analysis, only women showed a significant improvement in GLS and a trend towards greater improvement in GLS according to severity of systolic dysfunction as measured by LV ejection fraction could be noted. CONCLUSIONS: Immediate improvement in GLS was appreciated after TAVR procedure. Whether this finding continues to be noted in a more prolonged follow-up and its clinical implications need to be assessed in further studies.


Assuntos
Estenose da Valva Aórtica/cirurgia , Ventrículos do Coração/fisiopatologia , Substituição da Valva Aórtica Transcateter/métodos , Função Ventricular Esquerda/fisiologia , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Período Pós-Operatório , Estudos Prospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
6.
Can J Cardiol ; 32(12): 1574.e5-1574.e7, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27378590

RESUMO

We report on a 49-year-old man who presented to the emergency department with progressive angina. Echocardiography displayed severe aortic regurgitation and aortic valve thickening. The suspected diagnosis was acute aortic syndrome. Cardiac computed tomography showed circumferential thickening of the aortic wall and left main coronary artery ostial stenosis. Histologic examination showed diffuse aortic inflammation. No damage of any other organ or vascular structure was reported, and the final diagnosis was nonspecific aortitis. Differential diagnosis, prognosis, and therapeutic strategies are discussed.


Assuntos
Angina Pectoris , Aorta , Aortite , Angiografia por Tomografia Computadorizada/métodos , Ponte de Artéria Coronária/métodos , Estenose Coronária , Angina Pectoris/diagnóstico , Angina Pectoris/etiologia , Aorta/diagnóstico por imagem , Aorta/patologia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/fisiopatologia , Aortite/complicações , Aortite/diagnóstico , Aortite/fisiopatologia , Estenose Coronária/complicações , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Estenose Coronária/cirurgia , Diagnóstico Diferencial , Ecocardiografia/métodos , Eletrocardiografia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Resultado do Tratamento
7.
EuroIntervention ; 11 Suppl W: W32-6, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26384185

RESUMO

Mitral regurgitation is a source of significant morbidity and mortality with growing prevalence in an increasingly ageing population. The development of reparative percutaneous techniques allows offering treatment to patients ineligible for surgery. The mitral valve is a complex structure and these procedures are limited by anatomical variability and technical complexity. The most established mitral valve repair technique currently is the MitraClip, which requires a careful preoperative evaluation of the mitral valve apparatus to assess the patient's suitability for the intervention, where echocardiography plays an essential role.


Assuntos
Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Cateterismo Cardíaco/instrumentação , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Anuloplastia da Valva Mitral/instrumentação , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/terapia , Seleção de Pacientes , Valor Preditivo dos Testes , Desenho de Prótese , Índice de Gravidade de Doença , Resultado do Tratamento
8.
Echocardiography ; 32(1): 96-105, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24661050

RESUMO

BACKGROUND: Swirling flow, organized in vortices, contributes to adequate left ventricular function. In this study, we apply a novel echocardiographic flow-mapping technique, vector flow mapping (VFM), to evaluate the main characteristics of left ventricular vortices and its relation to filling parameters. METHODS: Forty-eight subjects underwent conventional transthoracic echocardiographic examination with additional intracardiac flow assessment with VFM using a Aloka Alpha-10 system and experimental VFM analysis software. To analyze vortex behavior, its rotation direction, duration, location inside the left ventricle, size, and intensity were assessed in apical long-axis view. Its relation to conventional left ventricular filling parameters was then analyzed. RESULTS: Two vortex components were consistently identified following each transmitral filling wave. The anterior component of these visualized vortices was analyzed, due to its higher significance in the cardiac cycle, following early filling (V1) and atrial contraction (V2). Differences were observed in several aspects of vortex behavior between V1 and V2, particularly in patients with normal left ventricular filling parameters. These differences may be related to varying roles of vortices in different periods of the cardiac cycle. CONCLUSIONS: Vector flow mapping allowed visualization and measurement of several parameters defining vortex behavior inside the cardiac cycle. The differences observed in these parameters between vortices in different phases of the cardiac cycle may be related to their role in optimizing cardiac function.


Assuntos
Velocidade do Fluxo Sanguíneo , Ecocardiografia/métodos , Ventrículos do Coração/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/fisiopatologia , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Reologia/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...