Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Animals (Basel) ; 11(7)2021 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-34359126

RESUMO

Llama fibre has the potential to become the most valuable textile resource in the Puna region of Argentina. In this study near infrared reflectance spectroscopy was evaluated to predict the mean fibre diameter in llama fleeces. Analyses between sets of carded and non-carded samples in combination with spectral preprocessing techniques were carried out and a total of 169 spectral signatures of llama samples in Vis and NIR ranges (400-2500 nm) were obtained. Spectral preprocessing consisted in wavelength selection (Vis-NIR, NIR and discrete ranges) and multiplicative and derivative pretreatments; spectra without pretreatments were also included, while modified partial least squares (M-PLS) regression was used to develop prediction models. Predictability was evaluated through R2: standard cross validation error (SECV), external validation error (SEV) and residual predictive value (RPD). A total of 54 calibration models were developed in which the best model (R2 = 0.67; SECV = 1.965; SEV = 2.235 and RPD = 1.91) was obtained in the Vis-NIR range applying the first derivative pretreatment. ANOVA analysis showed differences between carded and non-carded sets and the models obtained could be used in screening programs and contribute to valorisation of llama fibre and sustainable development of textile industry in the Puna territory of Catamarca. The data presented in this paper are a contribution to enhance the scarce information on this subject.

2.
Sensors (Basel) ; 20(3)2020 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-32033345

RESUMO

The control of refrigeration in the food chain is fundamental at all stages, with special emphasis on the retail stage. The implementation of information and communication technologies (IoT, open-source hardware and software, cloud computing, etc.) is representing a revolution in the operational paradigm of food control. This paper presents a low-cost IoT solution, based on free hardware and software, for monitoring the temperature in refrigerated retail cabinets. Specifically, the use of the ESP-8266-Wi-Fi microcontroller with DS18B20 temperature sensors is proposed. The ThingSpeak IoT platform is used to store and process data in the cloud. The solution presented is robust, affordable, and flexible, allowing to extend the scope of supervising other relevant parameters in the operating process (light control, energy efficiency, consumer presence, etc.).

3.
Appl Spectrosc ; 67(8): 924-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23876731

RESUMO

This research work investigated new methods to improve the accuracy of intact feed calibrations for the near-infrared (NIR) prediction of the ingredient composition. When NIR reflection spectroscopy, together with linear models, was used for the prediction of the ingredient composition, the results were not always acceptable. Therefore, other methods have been investigated. Three different local methods (comparison analysis using restructured near-infrared and constituent data [CARNAC]), locally weighed regression [LWR], and LOCAL) were applied to a large (N = 20 320) and heterogeneous population of non-milled feed compounds for the NIR prediction of the inclusion percentage of wheat and sunflower meal, as representative of two different classes of ingredients. Compared with partial least-squares regression, results showed considerable reductions of standard error of prediction values for all methods and ingredients: reductions of 59, 47, and 50% with CARNAC, LWR, and LOCAL, respectively, for wheat, and reductions of 49, 45, and 43% with CARNAC, LWR, and LOCAL, respectively, for sunflower meal. These results are a valuable achievement in coping with legislation and manufacture requirements concerning the labeling of intact feedstuffs.


Assuntos
Ração Animal/análise , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Animais , Helianthus/química , Proteínas de Vegetais Comestíveis/química , Reprodutibilidade dos Testes , Triticum/química
4.
J Agric Food Chem ; 56(21): 10135-41, 2008 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-18939849

RESUMO

In the context of current demands in the animal feed industry for controls and analyses, the use of instruments that may be applied on the process line has acquired a significant interest. A key aspect is that the calibrations developed for quality control with instruments sited in the laboratory (at-line) must be transferred to instruments that will be used in the plant itself (online). This study evaluates the standardization and the calibration transfer between a grating monochromator instrument (predispersive) designed for laboratory analysis and a diode array instrument (postdispersive) more adapted to process conditions. Two procedures that correct differences between spectra of two instruments were tested: the patented algorithm by Shenk and Westerhaus and piecewise direct standardization (PDS). Although results were slightly better with PDS, both methods achieved good spectral matching between the two instruments, with levels of repeatability similar to that of the grating instrument itself. The calibration transfer was evaluated in terms of the standard error of prediction (SEP), which was considerably reduced after standardization. However, final calibration models to be used in the diode array instrument must contain spectra from both types of instruments to give acceptable prediction accuracy.


Assuntos
Ração Animal/análise , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Espectroscopia de Luz Próxima ao Infravermelho/normas , Calibragem , Controle de Qualidade , Padrões de Referência
5.
J Agric Food Chem ; 56(9): 3185-92, 2008 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-18407654

RESUMO

Near-infrared calibrations were developed for the instantaneous prediction of the chemical and ingredient composition of intact compound feeds. Two rather different instruments were compared (diode array vs grating monochromator). The grating monochromator was used in a static mode in the laboratory, whereas the diode-array instrumentbetter adapted to online analysiswas placed on a conveyor belt to simulate measurements at a feed mill plant. Modified partial least squares (MPLS) equations were developed using the same set of samples analyzed in the two instruments. Sample set 1 ( N = 398) was used to predict crude protein (CP) and crude fiber (CF), while sample set 2 ( N = 393) was used for the prediction of one macroingredient (sunflower meal, SFM) and one microingredient (mineral-vitamin premix, MVP). The standard error of cross-validation (SECV) and the coefficient of determination (R2) values for CF were better using the monochromator instrument. However, results obtained for CP, SFM, and MVP using the samples analyzed in the diode-array instrument showed similar or even greater accuracy than those obtained using samples analyzed in the grating monochromator. The excellent predictive ability [R2> 0.95; RPD (ratio of standard deviation to SECV) > 3] obtained for CP, CF, and SFM opens the way for the online use of NIRS diode-array instruments for surveillance and monitoring in the manufacture, processing, and marketing of compound feeds. R2, RPD, and SECV values for MVP showed similar performance for both instruments. Although RPD values did not reach the minimum recommended for quantitative analysis, results are encouraging for an ingredient present in feed compounds in such very low amounts.


Assuntos
Ração Animal/análise , Manipulação de Alimentos , Laboratórios , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Calibragem , Análise dos Mínimos Quadrados , Sistemas On-Line , Controle de Qualidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...