Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Rev. Flum. Odontol. (Online) ; 2(67): 171-185, mai-ago.2025. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1577002

RESUMO

Este estudo teve como objetivo avaliar o dimorfismo sexual em uma coleção de mandíbulas portuguesas através de uma metodologia métrica digital, utilizando análise estatística descritiva, inferencial e multivariada para identificar quais parâmetros são mais dimórficos e quais são os melhores preditores de sexo. Trinta e três mandíbulas (14 mulheres e 19 homens) e pertences pessoais foram fotograficamente registrados com código e sexo. Os dados foram coletados por tomografia e as medidas foram feitas pelo software Simplant Pro. Foram registrados a largura máxima e mínima do ramo mandibular, altura condilar, altura do processo coronoide, altura da sínfise mandibular, ângulo mandibular, distâncias bimentual, biantegonial, bigonial e bicondilar e comprimento máximo mandibular. A análise estatística foi realizada utilizando IBM® SPSS. Os resultados mostraram diferenças estatisticamente significativas para os seguintes parâmetros: altura do processo coronoide, altura do côndilo, comprimento máximo da mandíbula e largura mínima do ramo mandibular. Na análise estatística multivariada foi possível identificar a altura do processo coronoide como melhor preditor de sexo com precisão em 72,2% dos casos. Isto permite uma diferenciação mais fácil entre mandíbulas femininas e masculinas com uma precisão de 64,3% e 78,9%, respectivamente. Foi possível concluir que a altura do processo coronoide é o parâmetro mais dimórfico e o melhor preditor de sexo na amostra.


This study aimed to assess sex dimorphism in a collection of Portuguese mandibles through a digital metric methodology by using descriptive, inferential, and multivariate statistical analysis to identify which parameters are the most dimorphic and which are the best sex predictors. Thirty-three mandibles (14 females and 19 males) and personal belongings were photographically registered with code and sex. Data was collected using tomography, and measurements were made using the Simplant Pro software. The maximum and minimum width of the mandibular ramus, condylar height, coronoid process height, mandibular symphysis height, mandibular angle, bi-mental, bi-antegonial, bi-gonial and bi-condylar distances, and maximal mandibular length were registered. Statistical analysis was performed using IBM® SPSS. The results showed statistically significant differences for the following parameters: coronoid process height, condyle height, the maximum length of the mandible, and the minimum width of the mandibular ramus. In the multivariate statistical analysis, it was possible to identify the coronoid process height as the best sex predictor accurately in 72.2% of cases. This allows for easier differentiation between female and male mandibles with an accuracy of 64.3% and 78.9%, respectively. It was possible to conclude that the coronoid process height is the most dimorphic parameter and the best sex predictor in the sample.

2.
Rev. Flum. Odontol. (Online) ; 1(66): 1-11, jan-abr.2025. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1570439

RESUMO

Introduction: This case report presents the intentional periodontal maintenance of two periodontal hopeless lower central incisors with a multidisciplinary approach and 20-year follow-up. Case presentation: A 36-year-old male, in 2001, was diagnosed with aggressive periodontitis, gingival swelling, bleeding, and mandibular central incisors with mobility and poor prognosis. Following periodontal therapy (phase I), root canal treatment, and occlusal adjustment, #31 and #41 were gently extracted to remove the granulation tissues, calculus, and infected cementum from the root surface. Then, tetracycline-HCl was applied for 5 minutes on the root surfaces. The teeth were repositioned into the sockets and splinted with a lingual bar. At 3 months, the bar was removed, and a free gingival autogenous graft was done to improve the local keratinized tissue width. Mobility scores, pocket depths, and clinical attachment levels were recorded, and radiographs were taken at 1, 5, and 20 years. The 5-year follow-up showed that the teeth were clinically and radiographically in function. There was a reduction in probing depth and a gain in clinical attachment and radiographic alveolar bone levels. After 20 years, #41 was stable, but #31 had external root resorption, leading to a new treatment plan (dental implants) and extraction. Conclusion: The clinical result of this case was satisfactory for 20 years. Intentional periodontal maintenance of the teeth may be an alternative treatment, even considering the high level of complexity.


Assuntos
Humanos , Masculino , Adulto , Planejamento de Assistência ao Paciente , Periodontia , Procedimentos Cirúrgicos Operatórios , Tempo , Perda da Inserção Periodontal
3.
J Funct Biomater ; 15(7)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-39057299

RESUMO

The present study evaluated the mechanical behavior of five designs of Morse taper (MT) connections with and without the application of loads. For this, the detorque of the fixing screw and the traction force required to disconnect the abutment from the implant were assessed. A total of 100 sets of implants/abutments (IAs) with MT-type connections were used, comprising five groups (n = 20/group): (1) Group Imp 11.5: IA sets with a cone angulation of 11.5°; (2) Group SIN 11.5: with a cone angulation of 11.5°; (3) Group SIN 16: with a cone angulation of 16°; (4) Group Neo 16: with a cone angulation of 16°; and (5) Group Str 15: with a cone angulation of 15°. All sets received the torque recommended by the manufacturer. After applying the torque, the counter torque of the fixing screws was measured in ten IA sets of each group without the application of cyclic loads (frequencies ≤ 2 Hz, 360,000 cycles, and force at 150 Ncm). The other ten sets of each group were subjected to cyclic loads, after which the detorque was measured. Afterwards, the force for disconnection between the implant and the abutment was measured by traction on all the samples. The untwisting of the abutment fixation screws showed a decrease in relation to the initial torque applied in all groups. In the unloaded samples, it was found to be -25.7% in Group 1, -30.4% in Group 2, -36.8% in Group 3, -29.6% in Group 4, and -25.7% in Group 5. After the applied loads, it was found to be -44% in Group 1, -43.5% in Group 2, -48.5% in Group 3, -47.2% in Group 4, and -49.8% in Group 5. The values for the IA sets were zero for SIN 16 (Group 3) and Neo16 (Group 4), both without and with loads. In the other three groups, without loads, the disconnection value was 56.3 ± 2.21 N (Group 1), 30.7 ± 2.00 N (Group 2), and 26.0 ± 2.52 N (Group 5). After applying loads, the values were 63.5 ± 3.06 N for Group 1, 34.2 ± 2.45 N in Group 2, and 23.1 ± 1.29 N in Group 5. It was concluded that in terms of the mechanical behavior of the five designs of MT IA sets, with and without the application of loads, the Imp 11.5, SIN 11.5, and Srt 15 groups showed better results compared to the SIN 16 and Neo 16 groups, showing that lower values of cone angulation increase the friction between the parts (IA), thus avoiding the need to maintain the torque of the fixing screw to maintain the union of the sets.

4.
J Funct Biomater ; 15(5)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38786635

RESUMO

The aim of this study was to evaluate the effect of local administration of melatonin (MLT) on molecular biomarkers and calvaria bone critical defects in female rats with or without osteoporosis, associated or not with a xenogeneic biomaterial. Forty-eight female rats were randomly divided into two groups: (O) ovariectomized and (S) placebo groups. After 45 days of osteoporosis induction, two critical-size defects (5 mm diameter) were created on the calvaria. The groups were subdivided according to the following treatment: (C) Clot, MLT, MLT associated with Bio-Oss® (MLTBO), and Bio-Oss® (BO). After 45 days, the defect samples were collected and processed for microtomography, histomorphometry, and biomolecular analysis (Col-I, BMP-2, and OPN). All animals had one femur harvested to confirm the osteoporosis. Microtomography analysis demonstrated a bone mineral density reduction in the O group. Regarding bone healing, the S group presented greater filling of the defects than the O group; however, in the O group, the defects treated with MLT showed higher mineral filling than the other treatments. There was no difference between the treatments performed in the S group (p = 0.05). Otherwise, O-MLT had neoformed bone higher than in the other groups (p = 0.05). The groups that did not receive biomaterial demonstrated lower levels of Col-I secretion; S-MLT and S-MLTBO presented higher levels of OPN, while O-C presented statistically lower results (p < 0.05); O-BO showed greater BMP-2 secretion (p < 0.05). In the presence of ovariectomy-induced osteoporosis, MLT treatment increased the newly formed bone area, regulated the inflammatory response, and increased OPN expression.

5.
Heliyon ; 10(3): e25038, 2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38322837

RESUMO

Background: The goal of this in vitro study was to compare three different surfaces: two types of implant surfaces commercially available ([a] smooth/machined and [b] acid-treated surface) versus (c) anodized surface. Discs were manufactured with commercially pure titanium (CP) grade IV, which were subsequently analyzed by scanning microscopy and fibroblastic and osteoblastic cell cultures. Methods: Ninety-nine discs (5 × 2 mm) were manufactured in titanium grade IV and received different surface treatments: (i) Mach group: machined; (ii) AA group: double acid etch; and (iii) AN group: anodizing treatment. Three discs from each group were analyzed by Scanning Electron Microscopy (SEM) to obtain surface topography images and qualitatively analyzed by EDS. Balb/c 3T3 fibroblasts and pre-osteoblastic cells (MC3T3-E1 lineage) were used to investigate each group's biological response (n = 10/cellular type). The data were compared statistically using the ANOVA one-way test, considered as a statistically significant difference p < 0.05. Results: The AA group had numerous micropores with diameters between 5 and 10 µm, while nanopores between 1 and 5 nm were measured in the AN group. The EDX spectrum showed a high titanium concentration in all the analyzed samples. The contact angle and wetting tension were higher in the AA, whereas similar results were observed for the other groups. A lower result was observed for base width in the AA, which was higher in the other two groups. The AN showed the best values in the fibroblast cells, followed by Mach and AA; whereas, in the culture of the MC3T3 cells, the result was precisely the opposite (AA > Mach > AN). There was similar behavior for cell adhesion for the test groups (Mach and AN), with greater adhesion of Balb/c 3T3 fibroblasts compared to MC3T3 cells; in the AA group, there was greater adherence for MC3T3 cells compared to Balb/c 3T3 fibroblasts. Conclusions: The findings suggest that different surface characteristics can produce different biological responses, possibly cell-line dependent. These findings have important implications for the design of implantable medical devices, where the surface characteristics can significantly impact its biocompatibility.

6.
Rev. Flum. Odontol. (Online) ; 1(63): 87-109, jan-abr. 2024. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1566923

RESUMO

Objective: The aim of this study was to analyze the intra- and inter-examiner reliability when using the DC/TMD axis 1 and verify the replicability and validity of the data obtained.Methods: The sample comprised 30 volunteers (students) of the Instituto Universitário de Ciências da Saúde Norte (Portugal). The calibration process consisted of a volunteer selection, theoretical and practical training, data collection, and agreement calculation. Examiners received proper previous training. Three dental practitioners applied the questionnaire (T1) and re-examined all the participants one week later (T2). To measure the degree of inter and intra-examiner agreement, multiple Kappa coefficients were obtained when nominal or ordinal variables were involved. When the correspondence between quantifiable variables was assessed, Pearson correlation coefficients and their statistical significance were replicated.Results: Regarding opening patterns, a strong overall agreement was obtained, only showing discrepancies in left-assisted and unassisted maximum openings (from -0.034 to -0.370 and -0.630 to -0.933, respectively). A high level of inter-examiner agreement during TMJ noise during the opening assessment was obtained, only displaying variations in clicks (Kappa -0.423 to 0.757). Protrusion movement showed negative kappa and weaker agreement of all measurements (Kappa between -0.034 and -0037). Small discrepancies were obtained from palpation assessment (left lateral pole- Kappa -0.034).Conclusion: There was no discernible and persistent difference in the amount of agreement among the three examiners, demonstrating that all three examiners were capable of participating in data collecting by employing the DC/TMD questionnaire. The findings indicated nearly perfect intra- and inter-examiner concordance scores.


Assuntos
Transtornos da Articulação Temporomandibular , Transtornos da Articulação Temporomandibular/classificação , Diagnóstico Clínico , Coleta de Dados , Odontólogos
7.
Biomed Mater ; 18(6)2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37844570

RESUMO

This study aimed to analyze the physicochemical and histological properties of nanostructured hydroxyapatite and alginate composites produced at different temperatures with and without sintering and implanted in rabbit tibiae. Hydroxyapatite-alginate (HA) microspheres (425-600 µm) produced at 90 and 5 °C without (HA90 and HA5) or with sintering at 1000 °C (HA90S and HA5S) were characterized and applied to evaluate thein vitrodegradation; also were implanted in bone defects on rabbit's tibiae (n= 12). The animals were randomly divided into five groups (blood clot, HA90S, HA5S, HA90, and HA5) and euthanized after 7 and 28 d. X-ray diffraction and Fourier-transform infrared analysis of the non-sintered biomaterials showed a lower crystallinity than sintered materials, being more degradablein vitroandin vivo. However, the sinterization of HA5 led to the apatite phase's decomposition into tricalcium phosphate. Histomorphometric analysis showed the highest (p< 0.01) bone density in the blood clot group, similar bone levels among HA90S, HA90, and HA5, and significantly less bone in the HA5S. HA90 and HA5 groups presented higher degradation and homogeneous distribution of the new bone formation onto the surface of biomaterial fragments, compared to HA90S, presenting bone only around intact microspheres (p< 0.01). The elemental distribution (scanning electron microscope and energy dispersive spectroscopy andµXRF-SR analysis) of Ca, P, and Zn in the newly formed bone is similar to the cortical bone, indicating bone maturity at 28 d. The synthesized biomaterials are biocompatible and osteoconductive. The heat treatment directly influenced the material's behavior, where non-sintered HA90 and HA5 showed higher degradation, allowing a better distribution of the new bone onto the surface of the biomaterial fragments compared to HA90S presenting the same level of new bone, but only on the surface of the intact microspheres, potentially reducing the bone-biomaterial interface.


Assuntos
Durapatita , Trombose , Animais , Coelhos , Durapatita/química , Síncrotrons , Materiais Biocompatíveis/química , Cerâmica , Alginatos/química
8.
Medicina (Kaunas) ; 59(7)2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37512062

RESUMO

Objective: The primary objective of the present retrospective clinical study was to evaluate and compare the clinical performance presented by castable abutments developed for the MT system versus intermediate machined abutments, specifically regarding prosthetic or implant fractures/loss; the secondary objective was to verify the looseness of the abutments and the behavior of the peri-implant soft tissues. Methods: This clinical retrospective study was conducted on patients rehabilitated between 2019 and 2020. Inclusion criteria were patients in good general health, with an implants-supporting single crown; with solid machined abutments (control group) or castable UCLA abutments; with a connection portion (base) machined in cobalt-chrome (test group) over Morse taper DuoCone implants in the posterior mandible area; and at least two years in function. Clinical assessment was carried out by the same professional, considering the following parameters: (A) prosthetic: (i) loosening of the fixation screw, (ii) fracture of the screw and (iii) the number of times the patient had some type of complication after the installation of the prostheses were evaluated; (B) biological: (i) without keratinized mucosa (KM), (ii) 1 mm or less, (iii) between 1 and 2 mm and (iv) greater than 2 mm of KM width; and the presence or absence of mucositis. Furthermore, radiographic evaluation was performed in order to assess the marginal bone loss. These evaluations permitted to compare the groups analyzed and patients enrolled. Data were statistically analyzed, with the level of significance set at α = 0.05. Results: 79 patients with 120 MT implants were evaluated (80 castable UCLA abutments and 40 machined solid abutments). The follow-up was from 2 to 4 years. There was a 100% implant survival rate. Therefore, the control group showed two fractured abutments (5%) and no abutment loosening (95% for prosthetic survival rate), whereas the test group showed no abutment fracture but nine loosening screws (11.3%) (100% for prosthetic survival rate). Keratinized mucosa was considered thin or absent in 19 implants in the control group (47.5%) and 42 in the test group (52.5%). Mucositis was found in 11 implants in the control group (27.5%) and 27 in the test group (33.8%). A positive correlation was observed between the width of keratinized mucosa and mucositis (r = 0.521, p = 0.002). The mean marginal bone loss was 2.3 mm, ranging from 1.1 to 5.8 mm. No correlation was observed when considering marginal bone loss versus the three parameters (implant diameter, implant length and time of the prosthesis in function). Conclusions: The results suggest that UCLA-type abutments are a viable option for rehabilitating implants with Morse taper connections, suggesting lower fracture risk. Further research is necessary to confirm these findings and thoroughly evaluate the clinical performance and long-term outcomes.


Assuntos
Mucosite , Humanos , Estudos Retrospectivos , Próteses e Implantes
9.
Rev. Flum. Odontol. (Online) ; 2(61): 91-106, maio-ago. 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1562630

RESUMO

The biological sealing (BS) around implants is a dominant factor to determine the long-term success of peri-implant health. There are several features of the BS around implants in common with the soft tissue attached to teeth, such as the presence of crevicular fluid, acquired pellicle, epithelium; otherwise, the quality of the BS around implants is weaker compared with the junctional epithelium of natural teeth. Then, this article aimed to describe three cases report showing the presence of a BS (cuticle-crevice fluid-acquired pellicle) around the fixed crowns on dental implants in the anterior zone, through photographic analysis. It was used a Nikon 8100 camera with a 105 mm macro lens and a Macro Ring circular flash. A photographic profile examination was made always showing the clinical case and, specifically, the focal point in the crown-gingival tissue (prosthesis boundary and peri-implant tissue), highlighting the anatomical gingiva on the ceramic prosthetic crown at an angle between 140 to 160 degrees. Although cases 1 and 2 had 1-year follow-up and case 3 around 4 years, the common findings for all treatments done were: (i) oral rehabilitation with crowns on dental implants; (ii) patients satisfied with the esthetic and functional result; (iii) stability of the soft tissue around the crowns; (iv) all the patients had a good oral hygiene; (v) presence of a thin membrane associated with the acquire pellicle, similar to an annular cuticle, which we named cuticle-acquired pellicle complex or tertiary cuticle or prosthetic-implant cuticle. This complex (cuticle-crevicular fluid-acquired pellicle) is suggested to be the responsible by the BS on dental implants. Moreover, the cuticle (epithelial part in the peri-implant sulcus), although similar to teeth, may be considered a tertiary pellicle due to be found on ceramic crowns on dental implants, differently of the primary and secondary pellicle. Whitin the limitation of these three cases reports, the BS was reported and can be introduced the new concept of the "cuticle-crevicular fluid-acquired pellicle complex" or "prosthetic-implant cuticle".


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Implantes Dentários , Líquido do Sulco Gengival , Biofilmes , Coroas , Película Dentária
10.
J Funct Biomater ; 14(3)2023 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-36976052

RESUMO

The goal of this retrospective clinical study was to evaluate the behavior of Morse-taper indexed abutments by analyzing the marginal bone level (MBL) after at least 12 months of function. Patients rehabilitated with single ceramic crowns between May 2015 and December 2020 received single Morse-taper connection implants (DuoCone implant) with two-piece straight abutment baseT used for at least 12 months, presenting periapical radiograph immediately after crown installation were enrolled. The position of the rehabilitated tooth and arch (maxilla or mandible), crown installation period, implant dimensions, abutment transmucosal height, installation site (immediate implant placement or healed area), associated with bone regeneration, immediate provisionalization, and complications after installation of the final crown were analyzed. The initial and final MBL was evaluated by comparing the initial and final X-rays. The level of significance was α = 0.05. Seventy-five patients (49 women and 26 men) enrolled had a mean period of evaluation of 22.7 ± 6.2 months. Thirty-one implant-abutment (IA) sets had between 12-18 months, 34 between 19-24 months, and 44 between 25-33 months. Only one patient failed due to an abutment fracture after 25 months of function. Fifty-eight implants were placed in the maxilla (53.2%) and 51 in the mandible (46.8%). Seventy-four implants were installed in healed sites (67.9%), and 35 were in fresh socket sites (32.1%). Thirty-two out of these 35 implants placed in fresh sockets had the gap filled with bone graft particles. Twenty-six implants received immediate provisionalization. The average MBL was -0.67 ± 0.65 mm in mesial and -0.70 ± 0.63 mm in distal (p = 0.5072). The most important finding was the statistically significant difference comparing the values obtained for MBL between the abutments with different transmucosal height portions, which were better for abutments with heights greater than 2.5 mm. Regarding the abutments' diameter, 58 had 3.5 mm (53.2%) and 51 had 4.5 mm (46.8%). There was no statistical difference between them, with the following means and standard deviation, respectively, -0.57 ± 0.53 mm (mesial) and -0.66 ± 0.50 mm (distal), and -0.78 ± 0.75 mm (mesial) and -0.746 ± 0.76 mm (distal). Regarding the implant dimensions, 24 implants were 3.5 mm (22%), and 85 implants (78%) had 4.0 mm. In length, 51 implants had 9 mm (46.8%), 25 had 11 mm (22.9%), and 33 implants were 13 mm (30.3%). There was no statistical difference between the abutment diameters (p > 0.05). Within the limitations of this study, it was possible to conclude that better behavior and lesser marginal bone loss were observed when using abutment heights greater than 2.5 mm of transmucosal portion and when placed implants with 13 mm length. Furthermore, this type of abutment showed a little incidence of failures within the period analyzed in our study.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA