Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Environ Health Perspect ; 121(9): 1054-60, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23823697

RESUMO

BACKGROUND: Errors in address geocodes may affect estimates of the effects of air pollution on health. OBJECTIVE: We investigated the impact of four geocoding techniques on the association between urban air pollution estimated with a fine-scale (10 m × 10 m) dispersion model and lung function in adults. METHODS: We measured forced expiratory volume in 1 sec (FEV1) and forced vital capacity (FVC) in 354 adult residents of Grenoble, France, who were participants in two well-characterized studies, the Epidemiological Study on the Genetics and Environment on Asthma (EGEA) and the European Community Respiratory Health Survey (ECRHS). Home addresses were geocoded using individual building matching as the reference approach and three spatial interpolation approaches. We used a dispersion model to estimate mean PM10 and nitrogen dioxide concentrations at each participant's address during the 12 months preceding their lung function measurements. Associations between exposures and lung function parameters were adjusted for individual confounders and same-day exposure to air pollutants. The geocoding techniques were compared with regard to geographical distances between coordinates, exposure estimates, and associations between the estimated exposures and health effects. RESULTS: Median distances between coordinates estimated using the building matching and the three interpolation techniques were 26.4, 27.9, and 35.6 m. Compared with exposure estimates based on building matching, PM10 concentrations based on the three interpolation techniques tended to be overestimated. When building matching was used to estimate exposures, a one-interquartile range increase in PM10 (3.0 µg/m3) was associated with a 3.72-point decrease in FVC% predicted (95% CI: -0.56, -6.88) and a 3.86-point decrease in FEV1% predicted (95% CI: -0.14, -3.24). The magnitude of associations decreased when other geocoding approaches were used [e.g., for FVC% predicted -2.81 (95% CI: -0.26, -5.35) using NavTEQ, or 2.08 (95% CI -4.63, 0.47, p = 0.11) using Google Maps]. CONCLUSIONS: Our findings suggest that the choice of geocoding technique may influence estimated health effects when air pollution exposures are estimated using a fine-scale exposure model.


Assuntos
Poluição do Ar/efeitos adversos , Cidades , Exposição Ambiental/análise , Monitoramento Ambiental/métodos , Volume Expiratório Forçado/efeitos dos fármacos , Mapeamento Geográfico , Capacidade Vital/efeitos dos fármacos , Adulto , França , Humanos , Modelos Teóricos
2.
J Allergy Clin Immunol ; 124(4): 681-7.e3, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19665764

RESUMO

BACKGROUND: Although uncontrolled asthma remains frequent, determinants of asthma control are poorly studied. OBJECTIVES: The aim was to estimate the distribution and the phenotypic characteristics of asthma control in 2 groups of subjects defined by the use of inhaled corticosteroids (ICS) in the past 12 months, in the Epidemiological study on the Genetics and Environment of Asthma, bronchial hyperresponsiveness and atopy (EGEA). METHODS: Five hundred one adult current patients with asthma who participated in the follow-up of the EGEA study were included. Asthma control was assessed from survey questions reflecting asthma control, as defined in the 2006 Global Initiative for Asthma guidelines. The factors analyzed were age, sex, educational level, body mass index, active and passive smoking, sensitization to aeroallergens, total IgE, rhinitis, chronic cough/phlegm, and age at asthma onset. Analyses were stratified according to ICS use. RESULTS: Uncontrolled asthma was more frequent in ICS users (27.6%, 35.0%, and 37.4% with controlled, partly-controlled, and uncontrolled asthma respectively) compared with non-ICS users (60.0%, 23.9%, and 16.1%, respectively). In ICS users, chronic cough or phlegm and female sex were independently and significantly related to uncontrolled asthma. In non-ICS users, high total IgE and sensitization to molds were associated with uncontrolled asthma. Smoking and rhinitis were not associated with asthma control. CONCLUSION: Optimal asthma control remained unachieved in the majority of patients with asthma in this study. Factors associated with uncontrolled asthma were different in ICS users (chronic cough/phlegm, female sex) and non-ICS users (high total IgE and sensitization to molds).


Assuntos
Corticosteroides/uso terapêutico , Asma/tratamento farmacológico , Asma/imunologia , Administração por Inalação , Adulto , Alérgenos/imunologia , Asma/epidemiologia , Estudos Transversais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...