Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 843-855, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38639169

RESUMO

INTRODUCTION: Among different coronary stents implanted in High Bleeding Risk (HBR) patients with an indication for short antiplatelet therapy, no comparisons in terms of efficacy have been provided. METHODS: A Network Meta Analysis was performed including all randomized controlled trials comparing different coronary stents evaluated in HBR patients. Major Adverse Cardiovascular Events (MACEs) as defined by each included trial were the primary end point, whereas TLR (target lesion revascularization), TVR (target vessel revascularization), stent thrombosis and total and major (BARC3-5) bleedings were the secondary ones. RESULTS: A total of four studies (ONYX ONE, LEADERS FREE, SENIOR and HBR in BIO-RESORT) including 6637 patients were analyzed with different kind of stents and dual antiplatelet therapy (DAPT) length (1 or 6 months) on 12 months follow-up. About one-third of these patients were defined HBR due to indication for oral anticoagulation. All drug eluting stents (DESs) reduced risk of MACE compared to Bare Metal Stents (BMSs) when followed by a 1-month DAPT. At SUCRA analysis, Orsiro was the device with the highest probability of performing best. Rates of TLR and TVR were significantly lower when using Resolute Onyx, Synergy and BioFreedom stents in comparison to BMS when followed by 1-month DAPT, with Synergy ranking best. Synergy also showed a significantly lower number of stent thrombosis compared to BMS (RR 0.28, 95% CI 0.06-0.93), while Orsiro and Resolute Integrity showed the highest probability of performing best. CONCLUSION: In HBRs patients, all DESs were superior to BMSs in terms of efficacy and safety. Among DESs, Orsiro was the one with the highest ranking in terms of MACE, mainly driven by a reduced incidence of repeated revascularization and stent thrombosis.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Hemorragia , Metanálise em Rede , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária , Humanos , Doença da Artéria Coronariana/terapia , Trombose Coronária/etiologia , Trombose Coronária/prevenção & controle , Terapia Antiplaquetária Dupla , Hemorragia/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
J Card Fail ; 28(7): 1202-1216, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34774745

RESUMO

The intra-aortic balloon pump (IABP) is widely implanted as temporary mechanical circulatory support for cardiogenic shock (CS). However, its use is declining following the results of the IABP-SHOCK II trial, which failed to show a clinical benefit of the IABP in acute coronary syndrome (ACS)-related CS. Acute-on-chronic heart failure has become an increasingly recognized, distinct cause of CS (HF-CS). The pathophysiology of HF-CS differs from that of ACS-CS because it typically represents the progression from a state of congestion (with relatively preserved cardiac output) to a low-output state with hypoperfusion. The IABP is a volume-displacement pump that promotes forward flow from a high-capacitance reservoir to low-capacitance vessels, improving peripheral perfusion and decreasing left ventricular afterload in the setting of high filling pressures. The IABP can improve ventricular-vascular coupling and, therefore, myocardial energetics. Additionally, many patients with HF-CS are candidates for cardiac replacement therapies (left ventricular assist device or heart transplantation) and, therefore, may benefit from a bridge strategy that stabilizes the hemodynamics and end-organ function in preparation for more durable therapies. Notably, the new United Network for Organ Sharing donor heart allocation system has recently prioritized patients on IABP support. This review describes the role of IABP in the treatment of HF-CS. It also briefly discusses new strategies for vascular access as well as fully implantable versions for longer duration of support.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Infarto do Miocárdio , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/terapia , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos , Humanos , Balão Intra-Aórtico/métodos , Infarto do Miocárdio/terapia , Choque Cardiogênico/etiologia , Choque Cardiogênico/cirurgia , Doadores de Tecidos , Resultado do Tratamento
3.
Rev Cardiovasc Med ; 22(2): 439-444, 2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-34258910

RESUMO

Atrial fibrillation (AF) is the most common cardiac arrhythmia encountered in clinical practice. Despite the frequent coexistence with coronary artery disease (CAD), the prognostic independent implication of AF in patients with stable CAD remains controversial. Our aim was to perform a pairwise meta-analysis of adjusted observational studies comparing cardiovascular outcomes in patients with stable CAD with and without concomitant AF, in search of AF-specific prognostic implications. We performed random effect meta-analysis of binary outcome events in studies comparing stable CAD patients with versus without AF providing risk estimates adjusted for confounding variables. Literature search was performed in PubMed/MEDLINE and Google Scholar. Death was the primary endpoint of the analysis, while myocardial infarction, coronary revascularization and stroke secondary endpoints. 5 studies were included in the meta-analysis, encompassing a total of 30230 stable CAD patients (2844 with AF, 27386 without AF). Stable CAD patients with AF presented an independent increased risk of death (HR 1.39, 95% CI: 1.17-1.66) and stroke (HR 1.88, 95% CI: 1.45-2.45) compared to those without AF. Instead, risk of myocardial infarction (HR 0.90, 95% CI: 0.66-1.22) and coronary revascularization (HR 0.96, 95% CI: 0.79-1.16) did not differ in stable CAD patients with and without the arrhythmia. In patients with stable CAD, AF exerts an independent negative prognostic effect, increasing the risk of death and stroke. However, the small number of eligible studies included in this analysis highlights the astonishing lack of data regarding prognostic implications of concomitant AF in patients with stable CAD.


Assuntos
Fibrilação Atrial , Doença da Artéria Coronariana , Acidente Vascular Cerebral , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/terapia , Humanos , Estudos Observacionais como Assunto , Prognóstico , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia
4.
Int J Cardiol ; 300: 73-79, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31619362

RESUMO

BACKGROUND: Cystatin C (CyC) role in the detection of contrast induced acute kidney injury (CIAKI) is controversial. This study assessed whether a single CyC determination before coronary angiography (CA)could predict CIAKI and long-term adverse events. METHODS: CyC was assessed before CA in 713 consecutive patients. CIAKI was the primary endpoint, defined as ≥0.3 mg/dl creatinine (sCR) increase at 48 h or ≥50% in 7-days. All-cause death, cardiovascular (CV)death and MACE (acute coronary syndrome, acute pulmonary edema,CV death) were secondary endpoints. Re-hospitalization, in-hospital death and worsening renal function were tertiary endpoints. RESULTS: CIAKI occurred in 47 (6.7%) patients. ROC analysis showed a good accuracy of CyC in the prediction of CIAKI (AUC 0.82,p < 0.01), compared with baseline sCR and sCR-eGFR (AUC 0.70 and 0.75 respectively, both p < 0.01). CyC was associated with 10-year CV-death, all-cause death and MACEs (AUC 0.76,0.74 and 0.64 respectively,all p < 0.01). A CyC cut-off value of 1.4 mg/L was not only accurate in predicting or ruling-out CIAKI following CA (97% negative predictive value, 84% specificity), but also useful as a prognostic marker for 10-year adverse events (50% vs.16% all cause mortality, 29% vs.3% CV death, 39% vs.13% MACE,all p < 0.01), re-hospitalizations (54% vs.35%,p < 0.01) and worsening renal function (34% vs.19%,p < 0.01). The strongest and independent risk factor for 10-year CV death was baseline CyC>1.4 mg/L (HR 17.3, 95% CI 1.94-155.1). CONCLUSIONS: A baseline determination of CyC before CA can accurately rule out CIAKI and predict adverse events in the long term. CIAKI can be ruled out before CA in 97% patients with a CyC value < 1.4 mg/L.


Assuntos
Injúria Renal Aguda/sangue , Injúria Renal Aguda/diagnóstico por imagem , Meios de Contraste/efeitos adversos , Angiografia Coronária/tendências , Cistatina C/sangue , Injúria Renal Aguda/induzido quimicamente , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Estudos de Coortes , Angiografia Coronária/métodos , Feminino , Taxa de Filtração Glomerular/efeitos dos fármacos , Taxa de Filtração Glomerular/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...