1.
J Periodontol ; 87(2): 168-74, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26513267

RESUMO

BACKGROUND: The influence of diamond-like carbon (DLC) films on bacterial leakage through the interface between abutments and dental implants of external hexagon (EH) and internal hexagon (IH) designs was evaluated. METHODS: Film deposition was performed by plasma-enhanced chemical vapor deposition. Sets of implants and abutments (n = 30 per group, sets of 180 implants) were divided according to connection design and treatment of the abutment base: 1) no treatment (control); 2) DLC film deposition; and 3) Ag-DLC film deposition. Under sterile conditions, 1 µL Enterococcus faecalis was inoculated inside the implants, and abutments were tightened. The sets were tested for immediate external contamination, suspended in test tubes containing sterile culture broth, and followed for 5 days. Turbidity of the broth indicated bacterial leakage. At the end of the period, the abutments were removed and the internal content of the implants was collected with paper points and plated in Petri dishes. After 24-hour incubation, they were assessed for bacterial viability and colony-forming unit counting. Bacterial leakage was analyzed by χ(2) and Fisher exact tests (α = 5%). RESULTS: The percentage of bacterial leakage was 16.09% for EH implants and 80.71% for IH implants (P <0.0001). The bacterial load was higher inside IH implants (P = 0.000). The type of implant significantly influenced the results (P = 0.000), whereas the films did not (P = 0.487). CONCLUSION: IH implants show a higher frequency of bacterial leakage; and DLC and Ag-DLC films do not significantly reduce the frequency of bacterial leakage and bacteria load inside the implants.


Assuntos
Implantes Dentários , Infiltração Dentária/microbiologia , Carbono , Dente Suporte , Projeto do Implante Dentário-Pivô , Planejamento de Prótese Dentária , Diamante
2.
Int J Oral Maxillofac Implants ; 30(6): 1310-6, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26574857

RESUMO

PURPOSE: To determine the effect of maintaining torque after mechanical cycling of abutment screws that are coated with diamondlike carbon and coated with diamondlike carbon doped with diamond nanoparticles, with external and internal hex connections. MATERIALS AND METHODS: Sixty implants were divided into six groups according to the type of connection (external or internal hex) and the type of abutment screw (uncoated, coated with diamondlike carbon, and coated with diamondlike carbon doped with diamond nanoparticles). The implants were inserted into polyurethane resin and crowns of nickel chrome were cemented on the implants. The crowns had a hole for access to the screw. The initial torque and the torque after mechanical cycling were measured. The torque values maintained (in percentages) were evaluated. Statistical analysis was performed using one-way analysis of variance and the Tukey test, with a significance level of 5%. RESULTS: The largest torque value was maintained in uncoated screws with external hex connections, a finding that was statistically significant (P = .0001). No statistically significant differences were seen between the groups with and without coating in maintaining torque for screws with internal hex connections (P = .5476). CONCLUSION: After mechanical cycling, the diamondlike carbon with and without diamond doping on the abutment screws showed no improvement in maintaining torque in external and internal hex connections.


Assuntos
Parafusos Ósseos , Carbono , Dente Suporte , Implantação Dentária/métodos , Implantes Dentários , Diamante , Análise de Variância , Implantação Dentária/instrumentação , Retenção em Prótese Dentária , Análise do Estresse Dentário , Humanos , Nanopartículas , Estresse Mecânico , Torque