1.
Mar Pollut Bull ; 60(12): 2225-32, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20832088

RESUMO

The spatial distribution of As (total As, As (III) and As (V)) in estuarine sediments from the main tributaries of Todos os Santos Bay, BA, Brazil, was evaluated under high and low flow conditions. The concentrations of As were determined using a slurry sampling procedure with hydride generation atomic absorption spectrometry (HG-AAS). The highest concentrations were observed at estuary mouths, and exceeded conservative lower threshold value (Threshold Effects Level; TEL). Due to the oxic conditions and abundance of Mn and Fe (oxyhydr)oxides in the sediments, most inorganic arsenic in the Subaé and Paraguaçu estuaries was present as As (V). Nevertheless, the concentration of As (III) at several locations along the Jaguaripe River were also above the TEL value, suggesting that As may be toxic to biota. In the Subaé estuary, antropogenic activities are the main source of As. At the Jaguaripe and at Paraguaçu estuaries, nevertheless, natural sources of As need to be considered to explain the distribution patterns.


Assuntos
Arsênio/análise , Sedimentos Geológicos/química , Poluentes Químicos da Água/análise , Oceano Atlântico , Brasil , Monitoramento Ambiental , Água Doce/química , Água do Mar/química
2.
Talanta ; 80(2): 559-64, 2009 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-19836520

RESUMO

The quantitative determination of chemical elements in organic or biological samples is an important analytical problem. Normally the elements to be determined in the organic matrix must be transformed into a simple inorganic form. A digestion method by heating on a block digestor has been developed for the determination of Al, As, Ba, Ca, Cd, Co, Cu, Fe, Mg, Mn, V and Zn in Oyster tissue by ICP OES. A simplex centroid statistical mixture design has been used to study the effects of changing HNO(3), HCl and H(2)O(2) reagent proportions on the digestion of these samples. Response surface and principal component analyses show that the species Ca, Cd, Cu, Fe, Mg, Mn and Zn have very similar analytical tendencies under this experiment. By means of mixture modeling maximum recoveries for these ions were predicted using 19%, 18% and 63% of the HCl, HNO(3) and H(2)O(2) pseudocomponent mixtures, respectively. This corresponds to 21.4%, 30.8% and 47.8% of the HCl, HNO(3) and H(2)O(2) commercial solutions. Furthermore the As, Co and V ions present large recoveries for these mixtures as well. The Al and Ba ion recoveries are seen to be independent of the mixture proportions. The analysis of Oyster tissue reference material (SRM 1566b - NIST) under optimized conditions at the selected wavelengths resulted in ion recoveries between 90% and 100%.


Assuntos
Técnicas de Química Analítica/métodos , Metais/análise , Ostreidae/química , Análise Espectral/métodos , Alumínio/análise , Alumínio/química , Análise de Variância , Animais , Arsênio/análise , Arsênio/química , Bário/análise , Bário/química , Cádmio/análise , Cádmio/química , Cálcio/análise , Cálcio/química , Cobalto/análise , Cobalto/química , Cobre/análise , Cobre/química , Ácido Clorídrico/química , Peróxido de Hidrogênio/química , Íons/análise , Íons/química , Ferro/análise , Ferro/química , Magnésio/análise , Magnésio/química , Manganês/análise , Manganês/química , Metais/química , Ácido Nítrico/química , Reprodutibilidade dos Testes , Vanádio/análise , Vanádio/química , Zinco/análise , Zinco/química
3.
Anal Chim Acta ; 597(2): 179-86, 2007 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-17683728

RESUMO

The present paper describes fundamentals, advantages and limitations of the Box-Behnken design (BBD) for the optimization of analytical methods. It establishes also a comparison between this design and composite central, three-level full factorial and Doehlert designs. A detailed study on factors and responses involved during the optimization of analytical systems is also presented. Functions developed for calculation of multiple responses are discussed, including the desirability function, which was proposed by Derringer and Suich in 1980. Concept and evaluation of robustness of analytical methods are also discussed. Finally, descriptions of applications of this technique for optimization of analytical methods are presented.

4.
Anal Chim Acta ; 575(1): 133-7, 2006 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-17723582

RESUMO

The present paper proposes a pre-concentration procedure for determination of lead and iron in several samples by flame atomic absorption spectrometry. In it, lead(II) and iron(III) ions are coprecipitated using the violuric acid-copper(II) system as collector. Afterwards, the precipitate is dissolved with 1M HNO3 solution and the metal ions are determined. The optimization step was performed using factorial design involving the variables: pH, violuric acid mass (VA) and copper concentration (Cu). Using the optimized experimental conditions, the proposed procedure allows the determination these metals with detection limits of 0.18 microg L(-1) for iron and 0.16 microg L(-1) for lead. The effects of foreign ions on the pre-concentration procedure were also evaluated and the results demonstrated that this method could be applied for determination of iron and lead in several real samples. The proposed method was successfully applied to the analysis of seawater, urine, mineral water, soil and physiological solution samples. The concentrations of lead and iron achieved in these samples agree well with others data reported in the literature.

5.
J Hazard Mater ; 112(3): 279-83, 2004 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-15302449

RESUMO

The present paper proposes an on-line preconcentration procedure for cadmium determination in drinking water samples. It is based on the precipitation of cadmium(II) ions on a knotted reactor (KR) using 1(2-thiazolylazo)-p-cresol (TAC) as complexing reagent. The optimization step was performed using a full factorial design involving the variables: pH, eluent concentration (nitric acid) and TAC concentration. The results of this experiment demonstrated that these variables at chosen levels are not statistically significant. Under optimized experimental established conditions, analytical parameters for the preconcentration method were: a detection limit of 40.0 ng/l, precision as relative standard deviation (RSD) of 1.2 and 1.0%, for cadmium concentration of 2.5 and 20.0 microg/l, respectively. The preconcentration factor considering the slopes of the analytical curves with and without preconcentration is 23 for a sample volume of 10 ml. This system shows a sampling frequency of 25 h(-1). In order to check the accuracy, the standard reference material, NIST SRM 1643d trace elements in water was analyzed. A comparison, using t-test demonstrates that there is not significant difference among the achieved results with proposed method and the certified values. The addition/recovery experiments in the samples analyzed demonstrated the accuracy and applicability of the system developed for cadmium determination in water samples.


Assuntos
Cádmio/análise , Cádmio/química , Cresóis/química , Espectrofotometria Atômica/métodos , Tiazóis/química , Poluentes Químicos da Água/análise , Poluição da Água/análise , Indicadores e Reagentes/química
6.
Talanta ; 63(4): 1077-82, 2004 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-18969536

RESUMO

A system for on-line preconcentration and determination of platinum by ultrasonic nebulization (USN) coupled to inductively coupled plasma optical emission spectrometry (ICP-OES) was studied. It is based on the chemical sorption of platinum on a column packed with polyurethane foam loaded with thiocyanate reagent. The optimization step was carried out using two level full factorial design. Three variables (pH, loading flow rate (LFR) and eluent concentration) were regarded as factors in the optimization. Results of the two level factorial design 2(3) with three replicates of the central point for platinum preconcentration, based on the variance analysis (ANOVA), demonstrated that the factors and their interactions are not statistically significant. The proposed procedure allowed the determination of platinum with a detection limit of 0.28mugl(-1). The precision for 10 replicate determinations at 10.0mugl(-1) Pt level was 3.8% relative standard deviation (R.S.D.), calculated from the peak heights obtained. A total enhancement factor of 100 was obtained with respect to ICP-OES using pneumatic nebulization (10 for USN and 10 for preconcentration). A sampling frequency of 50 samples per hour was obtained. The effect of other ions in concentrations agreeing with water samples was studied. The addition/recovery experiments in the samples analyzed demonstrated the accuracy and applicability of the system developed for platinum determination in spiked water samples.

7.
Anal Bioanal Chem ; 375(3): 443-9, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12589511

RESUMO

A system for on-line preconcentration and determination of lead by flame atomic absorption spectrometry (FAAS) was proposed. It was based on the sorption of lead(II) ions on a minicolumn of polyurethane foam loaded with 2-(2-thiazolylazo)-5-dimethylaminophenol (TAM). The optimisation step was carried out using two-level full factorial and Doehlert designs for the determination of the optimum conditions for lead preconcentration. The proposed procedure allowed the determination of lead with a detection limit of 2.2 microg L(-1), and a precision, calculated as relative standard deviation (RSD), of 2.4 and 6.8 for a lead concentration of 50.0 and 10.0 microg L(-1), respectively. A preconcentration factor of 45 and a sampling frequency of 27 samples per hour were obtained. The recovery achieved for lead determination in the presence of several cations demonstrated that this procedure has enough selectivity for analysis of environmental samples. The validation was carried out by analysis of certified reference material. This procedure was applied to lead determination in natural food.


Assuntos
Chumbo/análise , Espectrofotometria Atômica/métodos , Cátions , Cromatografia , Desenho de Equipamento , Análise de Alimentos , Sistemas On-Line , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Atômica/instrumentação , Espectrofotometria Atômica/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...