Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Immunol Res ; 65(1): 299-306, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27475095

RESUMO

To evaluate the analytical agreement between results obtained from the indirect immunofluorescence methods and from the multiplexed line-blot assay and EliA-M2, to analyze the diagnostic accuracy in a cohort of primary biliary cirrhosis (PBC) patients and in control patients of two different types of tests for anti-M2 and assess whether, with the advent of a quantitative test, the possibility exists to correlate disease activity with the value of AMA. Serum analysis of 67 patients with fluorescence patterns detected on Hep-2 cells suggestive of PBC-related antibodies and three groups of patients (15 PBC, 16 PBC suspect and 48 disease controls) was carried out. All samples were tested by both a qualitative test multiplexed line-blot Autoimmune Liver Disease Profile Euroline and by a quantitative test EliA-M2 IgG. In order to evaluate a possible correlation between the quantitative M2 and disease activity, we divided patients mixed in a further three groups based on the value EliA-M2. For each of these groups were calculated the average values of the main indices of cholestasis. A perfect agreement was shown between the EliA-M2 and the multiplexed line-blot method for AMA detection. All sera of patients with PBC were positive with both tests, with a 100 % sensitivity. Forty-seven of the 48 sera of the control group were negative for both tests with a 100 % next specificity, and only 70 % for the AMA-IIF. We had also observed in the other three groups of patients that the average of the values of γ-glutamyl transpeptidase and alkaline phosphatase increases with the increase of the value EliA-M2. The difference between the mean values of the most significant parameter which the alkaline phosphatase of the three groups is significant, with a statistically significant difference between the first and the third group (p value 0.023). Both the qualitative method Profile Euroline and the quantitative EliA-M2 have a high diagnostic accuracy for PBC, with a specificity higher than the immunofluorescence method. These preliminary data might suggest the possibility of using the dosage EliA-M2 not only in the diagnosis phase but also in the monitoring of disease activity.


Assuntos
Autoanticorpos/sangue , Cirrose Hepática Biliar/diagnóstico , Mitocôndrias/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Linhagem Celular Tumoral , Feminino , Humanos , Testes Imunológicos , Cirrose Hepática Biliar/sangue , Cirrose Hepática Biliar/imunologia , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...