1.
J Hazard Mater ; 470: 134278, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38631247

RESUMO

Resuspension caused by human walking activities is an important source of indoor bioaerosols and has been associated with health effects such as allergies and asthma. However, it is unknown whether inhalation of resuspended bioaerosols is an important exposure pathway for airborne infection. Also, crucial factors influencing the resuspension of settled microbes have not been quantified. In this study, we experimentally investigated the resuspension of culturable bacteria from human-stepping on polyvinyl chloride (PVC) flooring under different conditions. We determined the bacterial resuspension emission factor (ER), a normalized resuspension parameter for the ratio of resuspended mass in the air to the mass of settled particles, for two common bacteria, Escherichia coli and Salmonella enterica. The investigation involved varying factors such as microbial surface-attached durations (0, 1, 2, and 3 days), the absence or presence of nutrients on flooring surfaces, and changes in relative humidity (RH) (35%, 65%, and 85%). The results showed that, in the absence of nutrients, the highest ER values for E. coli and S. enterica were 3.8 × 10-5 ± 5.2 × 10-6 and 5.3 × 10-5 ± 6.0 × 10-6, respectively, associated with surface-attached duration of 0 days. As the surface-attached duration increased from 0 to 3 days, ER values decreased by 92% and 84% for E. coli and S. enterica, respectively. In addition, we observed that ER values decreased with the increasing RH, which is consistent with particle adhesion theory. This research offers valuable insights into microbial resuspension during human walking activities and holds the potential for assisting in the assessment and estimation of risks related to human exposure to bioaerosols.


Assuntos
Escherichia coli , Umidade , Caminhada , Humanos , Pisos e Cobertura de Pisos , Salmonella enterica , Aerossóis , Poluição do Ar em Ambientes Fechados , Microbiologia do Ar , Cloreto de Polivinila/química , Nutrientes
2.
Sci Rep ; 13(1): 18294, 2023 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-37880507

RESUMO

The number of respiratory particles emitted during different respiratory activities is one of the main parameters affecting the airborne transmission of respiratory pathogens. Information on respiratory particle emission rates is mostly available for adults (few studies have investigated adolescents and children) and generally involves a limited number of subjects. In the present paper we attempted to reduce this knowledge gap by conducting an extensive experimental campaign to measure the emission of respiratory particles of more than 400 children aged 6 to 12 years while they pronounced a phonetically balanced word list at two different voice intensity levels ("speaking" and "loudly speaking"). Respiratory particle concentrations, particle distributions, and exhaled air flow rates were measured to estimate the respiratory particle emission rate. Sound pressure levels were also simultaneously measured. We found out that median respiratory particle emission rates for speaking and loudly speaking were 26 particles s-1 (range 7.1-93 particles s-1) and 41 particles s-1 (range 10-146 particles s-1), respectively. Children sex was significant for emission rates, with higher emission rates for males during both speaking and loudly speaking. No effect of age on the emission rates was identified. Concerning particle size distributions, for both respiratory activities, a main mode at approximately 0.6 µm and a second minor mode at < 2 µm were observed, and no differences were found between males and females. This information provides important input parameters in predictive models adopted to estimate the transmission risk of airborne pathogens in indoor spaces.


Assuntos
Poluição do Ar em Ambientes Fechados , Expiração , Masculino , Adulto , Feminino , Adolescente , Humanos , Criança , Tamanho da Partícula
3.
Artigo em Inglês | MEDLINE | ID: mdl-37337048

RESUMO

BACKGROUND: The COVID-19 pandemic was caused by the SARS-CoV-2 coronaviruses transmitted mainly through exposure to airborne respiratory droplets and aerosols carrying the virus. OBJECTIVE: To assess the transport and dispersion of respiratory aerosols containing the SARS-CoV-2 virus and other viruses in a small office space using a diffusion-based computational modeling approach. METHODS: A 3-D computational model was used to simulate the airflow inside the 70.2 m3 ventilated office. A novel diffusion model accounting for turbulence dispersion and gravitational sedimentation was utilized to predict droplet concentration transport and deposition. The numerical model was validated and used to investigate the influences of partition height and different ventilation rates on the concentration of respiratory aerosols of various sizes (1, 10, 20, and 50 µm) emitted by continuous speaking. RESULTS: An increase in the hourly air change rate (ACH) from 2.0 to 5.6 decreased the 1 µm droplet concentration inside the office by a factor of 2.8 and in the breathing zone of the receptor occupant by a factor of 3.2. The concentration at the receptor breathing zone is estimated by the area-weighted average of a 1 m diameter circular disk, with its centroid at the center of the receptor mannequin mouth. While all aerosols were dispersed by airflow turbulence, the gravitational sedimentation significantly influenced the transport of larger aerosols in the room. The 1 and 10 µm aerosols remained suspended in the air and dispersed throughout the room. In contrast, the larger 20 and 50 µm aerosols deposited on the floor quickly due to the gravitational sedimentation. Increasing the partition between cubicles by 0.254 m (10") has little effect on the smaller aerosols and overall exposure. IMPACT: This paper provides an efficient computational model for analyzing the concentration of different respiratory droplets and aerosols in an indoor environment. Thus, the approach could be used for assessing the influence of the spatial concentration variations on exposure for which the fully mixed model cannot be used.

4.
J Aerosol Sci ; 173: 106179, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37069899

RESUMO

Propagation of respiratory particles, potentially containing viable viruses, plays a significant role in the transmission of respiratory diseases (e.g., COVID-19) from infected people. Particles are produced in the upper respiratory system and exit the mouth during expiratory events such as sneezing, coughing, talking, and singing. The importance of considering speaking and singing as vectors of particle transmission has been recognized by researchers. Recently, in a companion paper, dynamics of expiratory flow during fricative utterances were explored, and significant variations of airflow jet trajectories were reported. This study focuses on respiratory particle propagation during fricative productions and the effect of airflow variations on particle transport and dispersion as a function of particle size. The commercial ANSYS-Fluent computational fluid dynamics (CFD) software was employed to quantify the fluid flow and particle dispersion from a two-dimensional mouth model of sustained fricative [f] utterance as well as a horizontal jet flow model. The fluid velocity field and particle distributions estimated from the mouth model were compared with those of the horizontal jet flow model. The significant effects of the airflow jet trajectory variations on the pattern of particle transport and dispersion during fricative utterances were studied. Distinct differences between the estimations of the horizontal jet model for particle propagation with those of the mouth model were observed. The importance of considering the vocal tract geometry and the failure of a horizontal jet model to properly estimate the expiratory airflow and respiratory particle propagation during the production of fricative utterances were emphasized.

6.
J Expo Sci Environ Epidemiol ; 32(5): 689-696, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35351959

RESUMO

OBJECTIVE: To elucidate the role of phonation frequency (i.e., pitch) and intensity of speech on respiratory aerosol emissions during sustained phonations. METHODS: Respiratory aerosol emissions are measured in 40 (24 males and 16 females) healthy, non-trained singers phonating the phoneme /a/ at seven specific frequencies at varying vocal intensity levels. RESULTS: Increasing frequency of phonation was positively correlated with particle production (r = 0.28, p < 0.001). Particle production rate was also positively correlated (r = 0.37, p < 0.001) with the vocal intensity of phonation, confirming previously reported findings. The primary mode (particle diameter ~0.6 µm) and width of the particle number size distribution were independent of frequency and vocal intensity. Regression models of the particle production rate using frequency, vocal intensity, and the individual subject as predictor variables only produced goodness of fit of adjusted R2 = 40% (p < 0.001). Finally, it is proposed that superemitters be defined as statistical outliers, which resulted in the identification of one superemitter in the sample of 40 participants. SIGNIFICANCE: The results suggest there remain unexplored effects (e.g., biomechanical, environmental, behavioral, etc.) that contribute to the high variability in respiratory particle production rates, which ranged from 0.2 particles/s to 142 particles/s across all trials. This is evidenced as well by changes in the distribution of participant particle production that transitions to a more bimodal distribution (second mode at particle diameter ~2 µm) at higher frequencies and vocal intensity levels.


Assuntos
Fonação , Aerossóis e Gotículas Respiratórios , Feminino , Humanos , Masculino , Fala
7.
Indoor Air ; 31(6): 1896-1912, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34297885

RESUMO

The COVID-19 pandemic has highlighted the need to improve understanding of droplet transport during expiratory emissions. While historical emphasis has been placed on violent events such as coughing and sneezing, the recognition of asymptomatic and presymptomatic spread has identified the need to consider other modalities, such as speaking. Accurate prediction of infection risk produced by speaking requires knowledge of both the droplet size distributions that are produced, as well as the expiratory flow fields that transport the droplets into the surroundings. This work demonstrates that the expiratory flow field produced by consonant productions is highly unsteady, exhibiting extremely broad inter- and intra-consonant variability, with mean ejection angles varying from ≈+30° to -30°. Furthermore, implementation of a physical mouth model to quantify the expiratory flow fields for fricative pronunciation of [f] and [θ] demonstrates that flow velocities at the lips are higher than previously predicted, reaching 20-30 m/s, and that the resultant trajectories are unstable. Because both large and small droplet transport are directly influenced by the magnitude and trajectory of the expirated air stream, these findings indicate that prior investigations of the flow dynamics during speech have largely underestimated the fluid penetration distances that can be achieved for particular consonant utterances.


Assuntos
Aerossóis , Poluição do Ar em Ambientes Fechados , Boca/fisiologia , Fala/fisiologia , COVID-19 , Humanos , Sujeitos da Pesquisa , SARS-CoV-2
8.
Build Environ ; 170: 1-16, 2019 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-32055099

RESUMO

Carpet and rugs currently represent about half of the United States flooring market and offer many benefits as a flooring type. How carpets influence our exposure to both microorganisms and chemicals in indoor environments has important health implications but is not well understood. The goal of this manuscript is to consolidate what is known about how carpet impacts indoor chemistry and microbiology, as well as to identify the important research gaps that remain. After describing the current use of carpet indoors, questions focus on five specific areas: 1) indoor chemistry, 2) indoor microbiology, 3) resuspension and exposure, 4) current practices and future needs, and 5) sustainability. Overall, it is clear that carpet can influence our exposures to particles and volatile compounds in the indoor environment by acting as a direct source, as a reservoir of environmental contaminants, and as a surface supporting chemical and biological transformations. However, the health implications of these processes are not well known, nor how cleaning practices could be optimized to minimize potential negative impacts. Current standards and recommendations focus largely on carpets as a primary source of chemicals and on limiting moisture that would support microbial growth. Future research should consider enhancing knowledge related to the impact of carpet in the indoor environment and how we might improve the design and maintenance of this common material to reduce our exposure to harmful contaminants while retaining the benefits to consumers.

9.
Environ Res ; 167: 7-14, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30005199

RESUMO

Land-use regression (LUR) models provide location and time specific estimates of exposure to air pollution and thereby improve the sensitivity of health effects models. However, they require pollutant concentrations at multiple locations along with land-use variables. Often, monitoring is performed over short durations using mobile monitoring with research-grade instruments. Low-cost PM monitors provide an alternative approach that increases the spatial and temporal resolution of the air quality data. LUR models were developed to predict hourly PM concentrations across a metropolitan area using PM concentrations measured simultaneously at multiple locations with low-cost monitors. Monitors were placed at 23 sites during the 2015/16 heating season. Monitors were externally calibrated using co-located measurements including a reference instrument (GRIMM particle spectrometer). LUR models for each hour of the day and weekdays/weekend days were developed using the deletion/substitution/addition algorithm. Coefficients of determination for hourly PM predictions ranged from 0.66 and 0.76 (average 0.7). The hourly-resolved LUR model results will be used in epidemiological studies to examine if and how quickly, increases in ambient PM concentrations trigger adverse health events by reducing the exposure misclassification that arises from using less time resolved exposure estimates.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Monitoramento Ambiental , Monitoramento Ambiental/instrumentação , Monitoramento Ambiental/métodos , Modelos Teóricos , Material Particulado , Estações do Ano
10.
Sensors (Basel) ; 17(8)2017 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-28825680

RESUMO

There is concern regarding the heterogeneity of exposure to airborne particulate matter (PM) across urban areas leading to negatively biased health effects models. New, low-cost sensors now permit continuous and simultaneous measurements to be made in multiple locations. Measurements of ambient PM were made from October to April 2015-2016 and 2016-2017 to assess the spatial and temporal variability in PM and the relative importance of traffic and wood smoke to outdoor PM concentrations in Rochester, NY, USA. In general, there was moderate spatial inhomogeneity, as indicated by multiple pairwise measures including coefficient of divergence and signed rank tests of the value distributions. Pearson correlation coefficients were often moderate (~50% of units showed correlations >0.5 during the first season), indicating that there was some coherent variation across the area, likely driven by a combination of meteorological conditions (wind speed, direction, and mixed layer heights) and the concentration of PM2.5 being transported into the region. Although the accuracy of these PM sensors is limited, they are sufficiently precise relative to one another and to research grade instruments that they can be useful is assessing the spatial and temporal variations across an area and provide concentration estimates based on higher-quality central site monitoring data.

11.
J Expo Sci Environ Epidemiol ; 26(1): 86-94, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-25967067

RESUMO

Typical resuspension activities within the home, such as walking, have been estimated to contribute up to 25% of personal exposures to PM10. Chamber studies have shown that for moderate walking intensities, flooring type can impact the rate at which particles are re-entrained into the air. For this study, the impact of residential flooring type on incremental average daily (24 h) time-averaged exposure was investigated. Distributions of incremental time-averaged daily exposures to fine and coarse PM while walking within the residential micro-environment were predicted using CONTAM, the multizone airflow and contaminant transport program of the National Institute of Standards and Technology. Knowledge of when and where a person was walking was determined by randomly selecting 490 daily diaries from the EPA's consolidated human activity database (CHAD). On the basis of the results of this study, residential flooring type can significantly impact incremental time-averaged daily exposures to coarse and fine particles (α=0.05, P<0.05, N=490, Kruskal-Wallis test) with high-density cut pile carpeting resulting in the highest exposures. From this study, resuspension from walking within the residential micro-environment contributed 6-72% of time-averaged daily exposures to PM10.


Assuntos
Poluentes Atmosféricos/análise , Exposição Ambiental/análise , Pisos e Cobertura de Pisos , Tamanho da Partícula , Simulação por Computador , Monitoramento Ambiental , Habitação , Humanos , Maryland , Modelos Teóricos , Caminhada
12.
Environ Int ; 36(1): 8-14, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19796820

RESUMO

Studies have shown links between the concentration of allergens found in homes and asthma. Inhalation of allergens present in settled residential dust can occur when the dust is resuspended via human activity or air currents. Although previous studies have measured allergen concentrations in homes, the focus has been on the presence of the allergens in settled dust samples. However, the actual inhalation exposure is to airborne allergens. The relationship between the settled dust composition and suspended allergens and endotoxin and the effect of exposure of these aeroallergens to asthmatics are not well understood for species typically present indoors. In this study, settled dust and airborne particulate matter samples were collected in the homes and school classrooms of asthmatic children of ages 9 to 16 and analyzed for endotoxin and allergens including dust mite and cockroach allergen, and dog and cat dander (Der p1, Der f1, Bla g1, Can f1, and Fel d1, respectively). Concentrations of cockroach allergen were below detection limit for all samples. Measurements of the settled dust samples show higher dust mite allergen in bedroom samples than in living room samples. Concentrations of airborne endotoxin and indoor allergens were generally higher in the homes than those measured at school. Within the homes, higher concentrations of airborne allergens and endotoxin were observed in the living rooms compared to the bedrooms. Resuspension rates for endotoxin, dust mite allergen, and, cat and dog dander were estimated in this study. Calculated resuspension rates for cat dander (8.1x10(-7)+/-3.5x10(-7)min(-1)) and dust mite allergen (2.1x10(-6)+/-7.6x10(-7)min(-1)and 1.4x10(-5)+/-4.6x10(-6)min(-1) for Der p 1 and Der f 1, respectively) were found to be higher than those for dog dander (3.1x10(-7)+/-1.3x10(-7)min(-1)) and endotoxin (3.6x10(-7)+/-1.6x10(-7)min(-1)). Markers of asthma inflammation including nitrate in exhaled breath condensate (EBC) and exhaled nitric oxide (eNO), were correlated with the concentrations of dust mite allergen (Der p 1) (Spearman r=0.598; p-value=0.068 for EBC and Spearman r=0.819; p-value=0.007 for eNO) and cat dander (Fel d 1) (Spearman r=0.917; p-value=0.0002 for EBC and Spearman r=0.697; p-value=0.054 for eNO) present in PM(10) samples.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Alérgenos/análise , Asma/imunologia , Adolescente , Animais , Testes Respiratórios , Gatos , Criança , Pré-Escolar , Cães , Endotoxinas/análise , Monitoramento Ambiental , Feminino , Humanos , Masculino , Material Particulado/análise , Pneumonia/imunologia
13.
J Air Waste Manag Assoc ; 58(4): 502-16, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18422037

RESUMO

Resuspension experiments were performed in a single-family residence. Resuspension by human activity was found to elevate the mass concentration of indoor particulate matter with an aerodynamic diameter less than 10 microm (PM10) an average of 2.5 times as high as the background level. As summarized from 14 experiments, the average estimated PM10 resuspension rate by a person walking on a carpeted floor was (1.4 +/- 0.6) x 10(-4) hr(-1). The estimated residence time for PM in the indoor air following resuspension was less than 2 hr for PM10 and less than 3 hr for 2-microm tracer particles. However, experimental results show that the 2-microm tracer particles stayed in the combined indoor air and surface compartments much longer (>>19 days). Using a two-compartment model to simulate a regular deposition and resuspension cycle by normal human activity (e.g., walking and sitting on furniture), we estimated residence time for 2-microm conservative particulate pollutants to be more than 7 decades without vacuum cleaning, and months if vacuum cleaning was done once per week. This finding supports the observed long residence time of persistent organic pollutants in indoor environments. This study introduces a method to evaluate the particle resuspension rate from semicontinuous concentration data of particulate matter (PM). It reveals that resuspension and subsequent exfiltration does not strongly affect the overall residence time of PM pollutants when compared with surface cleaning. However, resuspension substantially increases PM concentration, and thus increases short-term inhalation exposure to indoor PM pollutants.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Material Particulado/análise , Clima , Habitação , Material Particulado/química , Fatores de Tempo , Ventilação
14.
J Air Waste Manag Assoc ; 57(2): 190-203, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17355080

RESUMO

A factor analytic model has been applied to resolve and apportion particles based on submicron particle size distributions downwind of a United States-Canada bridge in Buffalo, NY. The sites chosen for this study were located at gradually increasing distances downwind of the bridge complex. Seven independent factors were resolved, including four factors that were common to all of the five sites considered. The common factors were generally characterized by the existence of two or more number and surface area modes. The seven factors resolved were identified as follows: fresh tail-pipe diesel exhaust, local/street diesel traffic, aged/evolved diesel particles, spark-ignition gasoline emissions, background urban emissions, heavy-duty diesel agglomerates, and secondary/transported material. Submicron (<0.5 microm) and ultrafine (<0.1 microm) particle emissions downwind of the bridge were dominated by commercial diesel truck emissions. Thus, this study obtained size distinction between fresh versus aged vehicle exhaust and spark-ignition versus diesel emissions based on the measured high time-resolution particle number concentrations. Because this study mainly used particles <300 nm in diameter, some sources that would usually exhibit number modes >100 nm were not resolved. Also, the resolved profiles suggested that the major number mode for fresh tailpipe diesel exhaust might exist below the detection limit of the spectrometer used. The average particle number contributions from the resolved factors were highest closest to the bridge.


Assuntos
Poluentes Atmosféricos/análise , Poluentes Ocupacionais do Ar/análise , Canadá , Análise Fatorial , Modelos Estatísticos , Tamanho da Partícula , Estados Unidos , Emissões de Veículos
15.
J Air Waste Manag Assoc ; 54(9): 1188-96, 2004 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-15468671

RESUMO

This study compares an indoor-outdoor air-exchange mass balance model (IO model) with a chemical mass balance (CMB) model. The models were used to determine the contribution of outdoor sources and indoor resuspension activities to indoor particulate matter (PM) concentrations. Simultaneous indoor and outdoor measurements of PM concentration, chemical composition, and air-exchange rate were made for five consecutive days at a single-family residence using particle counters, nephelometers, and filter samples of integrated PM with an aerodynamic diameter of less than or equal to 2.5 microm (PM2.5) and PM with an aerodynamic diameter of less than or equal to 5 microm (PM5). Chemical compositions were determined by inductively coupled plasma mass-spectrometry. During three high-activity days, prescribed activities, such as cleaning and walking, were conducted over a period of 4-6 hr. For the remaining two days, indoor activities were minimal. Indoor sources accounted for 60-89% of the PM2.5 and more than 90% of the PM5 for the high-activity days. For the minimal-activity days, indoor sources accounted for 27-47% of PM2.5 and 44-60% of the PM5. Good agreement was found between the two mass balance methods. Indoor PM2.5 originating outdoors averaged 53% of outdoor concentrations.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Modelos Teóricos , Movimentos do Ar , Monitoramento Ambiental , Tamanho da Partícula
16.
J Expo Anal Environ Epidemiol ; 14 Suppl 1: S34-40, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15118743

RESUMO

Continuous laser particle counters collocated with time-integrated filter samplers were used to measure personal, indoor, and outdoor particulate matter (PM) concentrations for a variety of prescribed human activities during a 5-day experimental period in a home in Redwood City, CA, USA. The mean daytime personal exposures to PM(2.5) and PM(5) during prescribed activities were 6 and 17 times, respectively, as high as the pre-activity indoor background concentration. Activities that resulted in the highest exposures of PM(2.5), PM(5), and PM(10) were those that disturbed dust reservoirs on furniture and textiles, such as dry dusting, folding clothes and blankets, and making a bed. The vigor of activity and type of flooring were also important factors for dust resuspension. Personal exposures to PM(2.5) and PM(5) were 1.4 and 1.6 times, respectively, as high as the indoor concentration as measured by a stationary monitor. The ratio of personal exposure to the indoor concentration was a function of both particle size and the distance of the human activity from the stationary indoor monitor. The results demonstrate that a wide variety of indoor human resuspension activities increase human exposure to PM and contribute to the "personal cloud" effect.


Assuntos
Atividades Cotidianas , Poluição do Ar em Ambientes Fechados/análise , Exposição Ambiental , Movimentos do Ar , Coleta de Dados , Poeira , Monitoramento Ambiental/métodos , Filtração , Habitação , Humanos , Tamanho da Partícula
17.
Environ Sci Technol ; 38(6): 1759-64, 2004 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-15074686

RESUMO

A mathematical model was applied to continuous indoor and outdoor particulate matter (PM) measurements to estimate source strengths for a variety of prescribed human activities that resuspend house dust in the home. Activities included folding blankets, folding clothes, dry dusting, making a bed, dancing on a rug, dancing on a wood floor, vacuuming, and walking around and sitting on upholstered furniture. Although most of the resuspended particle mass from these activities was larger than 5 microm in diameter, the resuspension of PM2.5 and PM5 was substantial, with source strengths ranging from 0.03 to 0.5 mg min(-1) for PM2.5 and from 0.1 to 1.4 mg min(-1) for PM5. Source strengths for PM > 5 microm could not be quantified due to instrument limitations. The source strengths were found to be a function of the number of persons performing the activity, the vigor of the activity, the type of activity, and the type of flooring.


Assuntos
Atividades Cotidianas , Poluição do Ar em Ambientes Fechados/análise , Modelos Teóricos , Roupas de Cama, Mesa e Banho , Poeira , Pisos e Cobertura de Pisos , Habitação , Humanos , Tamanho da Partícula
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...