Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Anaesth Crit Care Pain Med ; 41(2): 101036, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35181529

RESUMO

INTRODUCTION: Neonatal and infant anaesthesia are associated with a high risk of perioperative complications. The aim of the current study was to describe those risks in France using the French data from the NECTARINE study. MATERIAL AND METHODS: Data from the French centres that participated to the NECTARINE study were analysed. The primary goal of the study was the description of patients' characteristics, procedures and perioperative management and their comparison with the results of the European NECTARINE study. Secondary outcomes were the description of major perioperative complications and death. RESULTS: Overall, 926 procedures collected in 15 centres (all teaching hospitals) were analysed. Comparison between the French and European NECTARINE cohorts found few differences related to patients' characteristics and procedures. The rate of interventions for critical events (respiratory, haemodynamic, and metabolic) was similar between the two cohorts. Near-infrared spectroscopy monitoring was used in 12% of procedures. Nearly none of the thresholds for these interventions met the published standards. By day 30, complications (respiratory, haemodynamic, metabolic, renal, and liver failure) and death were observed in 14.4% [95% CI 11.6-16.4]% and 1.8% [95% CI 1.1-2.9] of cases, respectively. DISCUSSION: Although the health status of the patients in the French cohort was less severe, procedures, management and postoperative complications and mortality rates were similar to the European cohort. However, thresholds for interventions were often inadequate in both cohorts. Efforts should be undertaken to improve the knowledge and use of new monitoring devices in this population.


Assuntos
Anestesia , Anestesia/efeitos adversos , Estudos de Coortes , França/epidemiologia , Humanos , Lactente , Recém-Nascido , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos
2.
Ann Intensive Care ; 9(1): 13, 2019 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-30671726

RESUMO

BACKGROUND: Intubation and extubation of ventilated patients are not risk-free procedures in the intensive care unit (ICU) and can be associated with morbidity and mortality. Intubation in the ICU is frequently required in emergency situations for patients with an unstable cardiovascular or respiratory system. Under these circumstances, it is a high-risk procedure with life-threatening complications (20-50%). Moreover, technical problems can also give rise to complications and several new techniques, such as videolaryngoscopy, have been developed recently. Another risk period is extubation, which fails in approximately 10% of cases and is associated with a poor prognosis. A better understanding of the cause of failure is essential to improve success procedure. RESULTS AND CONCLUSION: In constructing these guidelines, the SFAR/SRLF experts have made use of new data on intubation and extubation in the ICU from the last decade to update existing procedures, incorporate more recent advances and propose algorithms.

4.
Arch Cardiovasc Dis ; 107(6-7): 361-70, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24996565

RESUMO

BACKGROUND: Transoesophageal echocardiography (TOE) is feasible in neonates using a miniaturized probe, but is not widely used because of low imaging quality. AIMS: To assess handling and imaging quality of a new release of a micro-TOE probe in children. METHODS: Thirty-eight consecutive children, enrolled during February and May 2013, underwent TOE with the Philips S8-3t probe. Insertion, handling and image quality were assessed. RESULTS: The 38 children (aged 7days to 12years; weight 3.1-27kg) underwent 75 TOE (30 [40.0%] before cardiac surgery, 31 [41.3%] after cardiac surgery, 4 [5.3%] during a percutaneous procedure, 10 [13.3%] in the intensive care unit). Insertion of the micro-TOE probe was 'very easy' in 37/38 patients (97.4%). Handling was better in the lightest children (P=0.001). Image quality was mainly 'good' or 'very good', with no significant changes between preoperative and postoperative examinations or over time. Total scores (insertion, handling, image quality) were significantly better in the lightest children (P=0.02). Preoperative TOE did not provide additional information over transthoracic echocardiography. Postoperative TOE was useful to assess surgical results, but no residual lesions required extracorporeal circulation return. Micro-TOE was useful during the postoperative care of neonatal surgery with open breastbone to assess the surgical result and ventricular function. It was also useful to guide extracorporeal membrane oxygenation (ECMO) indication and withdrawal; and was a useful guide for percutaneous procedures. CONCLUSION: Micro-multiplane TOE is safe and efficient for use in neonates and children. This minimally invasive tool increases the impact of TOE in paediatric cardiology.


Assuntos
Ecocardiografia Doppler em Cores/instrumentação , Ecocardiografia Transesofagiana/instrumentação , Cardiopatias/diagnóstico por imagem , Fatores Etários , Peso Corporal , Criança , Pré-Escolar , Ecocardiografia Doppler em Cores/efeitos adversos , Ecocardiografia Transesofagiana/efeitos adversos , Desenho de Equipamento , Cardiopatias/terapia , Humanos , Interpretação de Imagem Assistida por Computador , Lactente , Recém-Nascido , Miniaturização , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco
5.
Anesth Analg ; 119(1): 67-75, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24806140

RESUMO

BACKGROUND: Preoperative flushing of an anesthesia workstation is an alternative for preparation of the anesthesia workstation before use in malignant hyperthermia-susceptible patients (MHS). We studied in vitro, using a test lung, the washout profile of sevoflurane in 7 recent workstations during adult and, for the first time, pediatric ventilation patterns. METHODS: Anesthesia workstations were first primed with 3% sevoflurane for 2 hours and then prepared according to the recommendations of the Malignant Hyperthermia Association of the United States. The flush was done with maximal fresh gas flow (FGF) with a minute ventilation equal to 600 mL × 15, to reach a sevoflurane concentration of <5 parts per million. After flush, 2 clinical situations were simulated in vitro to test the efficiency of preparation: decrease of FGF from max to 10 L/min, or decrease of minute ventilation to 50 mL × 30, to simulate the ventilation of an MHS infant. RESULTS: We report washout delays for MHS patients for previously studied workstations (Primus®, Avance®, and Zeus®) and more interestingly, for machines not previously tested (Felix®, Flow-I®, Perseus®, and Leon®). An increase of sevoflurane concentration was observed when decreasing FGF (except for flow-I® and Leon®) and during simulation of MHS infant ventilation (except for Felix®). CONCLUSIONS: This descriptive study strongly suggests that washout profiles may differ for each anesthesia workstation. We advise the use of maximal FGF during preparation and anesthesia. Required flushing times are longer when preparing an anesthesia workstation before providing anesthesia for MHS infants.


Assuntos
Anestesia por Inalação/instrumentação , Anestésicos Inalatórios/administração & dosagem , Hipertermia Maligna/prevenção & controle , Éteres Metílicos/administração & dosagem , Adulto , Humanos , Lactente , Estudos Prospectivos , Sevoflurano
6.
Eur J Cardiothorac Surg ; 43(4): 864-5, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23178817

RESUMO

Tracheobronchial rupture due to blunt chest trauma is a rare but life-threatening injury among children. The severity of this condition ranges from death before hospital admission to clinical stability resulting in delayed management. Diagnosis is difficult because there is sometimes no evidence of external trauma, in spite of severe chest crush injury and consecutive rupture of airways. Here, we report the case of a 32-month-old girl whose torso was crushed by a van, resulting in bilateral bronchi disconnection. She was admitted to our hospital with cardiac and respiratory arrest. After prompt resuscitation, flexible bronchoscopy permitted the accurate visualization of the rupture and its extent. The life-saving procedure consisted of surgical repair using extracorporeal membrane oxygenation (ECMO) as ventilatory support. This provided rapid relief from the injury, which was previously expected to result in death. These data suggest that ECMO could be beneficial as supportive therapy for selected paediatric patients with major tracheobronchial traumas.


Assuntos
Brônquios/lesões , Brônquios/cirurgia , Oxigenação por Membrana Extracorpórea , Traumatismos Torácicos/terapia , Traqueia/lesões , Traqueia/cirurgia , Ferimentos não Penetrantes/terapia , Pré-Escolar , Enfisema , Feminino , Parada Cardíaca , Humanos , Pneumotórax , Traumatismos Torácicos/cirurgia , Tomografia Computadorizada por Raios X , Ferimentos não Penetrantes/cirurgia
7.
Anesth Analg ; 115(2): 310-4, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22584556

RESUMO

We measured the time it takes to reach the desired inspired anesthetic concentration using the Primus (Drägerwerk, AG, Lübeck, Germany) and the Avance (GE Datex-Ohmeda, Munich, Germany) anesthesia machines with toddler and newborn ventilation settings. The time to reach 95% of inspired target sevoflurane concentration was measured during wash-in from 0 to 6 vol% sevoflurane and during wash-out from 6 to 0 vol% with fresh gas flows equal to 1 and 2 times the minute ventilation. The Avance was faster than the Primus (65 seconds [95% confidence interval (CI): 55 to 78] vs 310 seconds [95% CI: 261 to 359]) at 1.5 L/min fresh gas flow, tidal volume of 50 mL, and 30 breaths/min. Times were shorter by the same magnitude at higher fresh gas flows and higher minute ventilation rates. The effect of doubling fresh gas flow was variable and less than expected. The Primus is slower during newborn than toddler ventilation, whereas the Avance's response time was the same for newborn and toddler ventilation. Our data confirm that the time to reach the target-inspired anesthetic concentration depends on breathing circuit volume, fresh gas flow, and minute ventilation.


Assuntos
Anestesia com Circuito Fechado/instrumentação , Anestésicos Inalatórios/farmacocinética , Pulmão/metabolismo , Éteres Metílicos/farmacocinética , Respiração Artificial/instrumentação , Ventiladores Mecânicos , Administração por Inalação , Anestésicos Inalatórios/administração & dosagem , Desenho de Equipamento , Humanos , Lactente , Recém-Nascido , Teste de Materiais , Éteres Metílicos/administração & dosagem , Estudos Prospectivos , Taxa Respiratória , Sevoflurano , Volume de Ventilação Pulmonar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...