Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Neuroanat ; 17: 1198042, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37332322

RESUMO

Basic behaviors, such as swallowing, speech, and emotional expressions are the result of a highly coordinated interplay between multiple muscles of the head. Control mechanisms of such highly tuned movements remain poorly understood. Here, we investigated the neural components responsible for motor control of the facial, masticatory, and tongue muscles in humans using specific molecular markers (ChAT, MBP, NF, TH). Our findings showed that a higher number of motor axonal population is responsible for facial expressions and tongue movements, compared to muscles in the upper extremity. Sensory axons appear to be responsible for neural feedback from cutaneous mechanoreceptors to control the movement of facial muscles and the tongue. The newly discovered sympathetic axonal population in the facial nerve is hypothesized to be responsible for involuntary control of the muscle tone. These findings shed light on the pivotal role of high efferent input and rich somatosensory feedback in neuromuscular control of finely adjusted cranial systems.

2.
J Neurosurg ; 139(5): 1396-1404, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37029679

RESUMO

OBJECTIVE: Intrinsic function is indispensable for dexterous hand movements. Distal ulnar nerve defects can result in intrinsic muscle dysfunction and sensory deficits. Although the ulnar nerve's fascicular anatomy has been extensively studied, quantitative and topographic data on motor axons traveling within this nerve remain elusive. METHODS: The ulnar nerves of 14 heart-beating organ donors were evaluated. The motor branches to the flexor carpi ulnaris (FCU) and flexor digitorum profundus (FDP) muscles and the dorsal branch (DoBUN) as well as 3 segments of the ulnar nerve were harvested in 2-cm increments. Samples were subjected to double immunofluorescence staining using antibodies against choline acetyltransferase and neurofilament. RESULTS: Samples revealed more than 25,000 axons in the ulnar nerve at the forearm level, with a motor axon proportion of only 5%. The superficial and DoBUN showed high axon numbers of more than 21,000 and 9300, respectively. The axonal mapping of more than 1300 motor axons revealed an increasing motor/sensory ratio from the proximal ulnar nerve (1:20) to the deep branch of the ulnar nerve (1:7). The motor branches (FDP and FCU) showed that sensory axons outnumber motor axons by a ratio of 10:1. CONCLUSIONS: Knowledge of the detailed axonal architecture of the motor and sensory components of the human ulnar nerve is of the utmost importance for surgeons considering fascicular grafting or nerve transfer surgery. The low number of efferent axons in motor branches of the ulnar nerve and their distinct topographical distribution along the distal course of the nerve is indispensable information for modern nerve surgery.


Assuntos
Transferência de Nervo , Nervo Ulnar , Humanos , Antebraço/inervação , Músculo Esquelético/inervação , Cotovelo , Axônios/fisiologia
3.
J Adv Res ; 44: 135-147, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36725185

RESUMO

INTRODUCTION: Neuromuscular control of the facial expressions is provided exclusively via the facial nerve. Facial muscles are amongst the most finely tuned effectors in the human motor system, which coordinate facial expressions. In lower vertebrates, the extracranial facial nerve is a mixed nerve, while in mammals it is believed to be a pure motor nerve. However, this established notion does not agree with several clinical signs in health and disease. OBJECTIVES: To elucidate the facial nerve contribution to the facial muscles by investigating axonal composition of the human facial nerve. To reveal new innervation pathways of other axon types of the motor facial nerve. METHODS: Different axon types were distinguished using specific molecular markers (NF, ChAT, CGRP and TH). To elucidate the functional role of axon types of the facial nerve, we used selective elimination of other neuronal support from the trigeminal nerve. We used retrograde neuronal tracing, three-dimensional imaging of the facial muscles, and high-fidelity neurophysiological tests in animal model. RESULTS: The human facial nerve revealed a mixed population of only 85% motor axons. Rodent samples revealed a fiber composition of motor, afferents and, surprisingly, sympathetic axons. We confirmed the axon types by tracing the originating neurons in the CNS. The sympathetic fibers of the facial nerve terminated in facial muscles suggesting autonomic innervation. The afferent fibers originated in the facial skin, confirming the afferent signal conduction via the facial nerve. CONCLUSION: These findings reveal new innervation pathways via the facial nerve, support the sympathetic etiology of hemifacial spasm and elucidate clinical phenomena in facial nerve regeneration.


Assuntos
Nervo Facial , Espasmo Hemifacial , Animais , Humanos , Axônios/fisiologia , Músculos Faciais , Nervo Facial/fisiologia , Vias Neurais , Roedores
4.
J Neurosci ; 2022 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-36216502

RESUMO

The surgical redirection of efferent neural input to a denervated muscle via a nerve transfer can reestablish neuromuscular control after nerve injuries. The role of autonomic nerve fibers during the process of muscular reinnervation remains largely unknown. Here, we investigated the neurobiological mechanisms behind the spontaneous functional recovery of denervated facial muscles in male rodents. Recovered facial muscles demonstrated an abundance of cholinergic axonal endings establishing functional neuromuscular junctions. The parasympathetic source of the neuronal input was confirmed to be in the pterygopalatine ganglion. Furthermore, the autonomically reinnervated facial muscles underwent a muscle fiber change to a purely intermediate muscle fiber population (MHCIIa). Finally, electrophysiological tests revealed that the postganglionic parasympathetic fibers travel to the facial muscles via the sensory infraorbital nerve. Our findings demonstrated expanded neuromuscular plasticity of denervated striated muscles enabling functional recovery via alien autonomic fibers. These findings may further explain the underlying mechanisms of sensory protection implemented to prevent atrophy of a denervated muscle.SIGNIFICANCE STATEMENT:Nerve injuries represent significant morbidity and disability for patients. Rewiring motor nerve fibers to other target muscles have shown to be a successful approach in the restoration of motor function. This demonstrates the remarkable capacity of the central nervous system to adapt to the needs of the neuromuscular system. Yet, the capability of skeletal muscles being reinnervated by non-motor axons remains largely unknown. Here, we show that under deprivation of original efferent input, the neuromuscular system can undergo functional and morphological remodeling via autonomic nerve fibers. This may explain neurobiological mechanisms of the sensory protection phenomenon, which is due to parasympathetic reinnervation.

5.
Clin Orthop Relat Res ; 480(6): 1191-1204, 2022 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35202032

RESUMO

BACKGROUND: Currently used prosthetic solutions in upper extremity amputation have limited functionality, owing to low information transfer rates of neuromuscular interfacing. Although surgical innovations have expanded the functional potential of the residual limb, available interfaces are inefficacious in translating this potential into improved prosthetic control. There is currently no implantable solution for functional interfacing in extremity amputation which offers long-term stability, high information transfer rates, and is applicable for all levels of limb loss. In this study, we presented a novel neuromuscular implant, the the Myoelectric Implantable Recording Array (MIRA). To our knowledge, it is the first fully implantable system for prosthetic interfacing with a large channel count, comprising 32 intramuscular electrodes. QUESTIONS/PURPOSES: The purpose of this study was to evaluate the MIRA in terms of biocompatibility, functionality, and feasibility of implantation to lay the foundations for clinical application. This was achieved through small- and large-animal studies as well as test surgeries in a human cadaver. METHODS: We evaluated the biocompatibility of the system's intramuscular electromyography (EMG) leads in a rabbit model. Ten leads as well as 10 pieces of a biologically inert control material were implanted into the paravertebral muscles of four animals. After a 3-month implantation, tissue samples were taken and histopathological assessment performed. The probes were scored according to a protocol for the assessment of the foreign body response, with primary endpoints being inflammation score, tissue response score, and capsule thickness in µm. In a second study, chronic functionality of the full system was evaluated in large animals. The MIRA was implanted into the shoulder region of six dogs and three sheep, with intramuscular leads distributed across agonist and antagonist muscles of shoulder flexion. During the observation period, regular EMG measurements were performed. The implants were removed after 5 to 6 months except for one animal, which retained the implant for prolonged observation. Primary endpoints of the large-animal study were mechanical stability, telemetric capability, and EMG signal quality. A final study involved the development of test surgeries in a fresh human cadaver, with the goal to determine feasibility to implant relevant target muscles for prosthetic control at all levels of major upper limb amputation. RESULTS: Evaluation of the foreign body reaction revealed favorable biocompatibility and a low-grade tissue response in the rabbit study. No differences regarding inflammation score (EMG 4.60 ± 0.97 [95% CI 4.00 to 5.20] versus control 4.20 ± 1.48 [95% CI 3.29 to 5.11]; p = 0.51), tissue response score (EMG 4.00 ± 0.82 [95% CI 3.49 to 4.51] versus control 4.00 ± 0.94 [95% CI 3.42 to 4.58]; p > 0.99), or thickness of capsule (EMG 19.00 ± 8.76 µm [95% CI 13.57 to 24.43] versus control 29.00 ± 23.31 µm [95% CI 14.55 to 43.45]; p = 0.29) were found compared with the inert control article (high-density polyethylene) after 3 months of intramuscular implantation. Throughout long-term implantation of the MIRA in large animals, telemetric communication remained unrestricted in all specimens. Further, the implants retained the ability to record and transmit intramuscular EMG data in all animals except for two sheep where the implants became dislocated shortly after implantation. Electrode impedances remained stable and below 5 kΩ. Regarding EMG signal quality, there was little crosstalk between muscles and overall average signal-to-noise ratio was 22.2 ± 6.2 dB. During the test surgeries, we found that it was possible to implant the MIRA at all major amputation levels of the upper limb in a human cadaver (the transradial, transhumeral, and glenohumeral levels). For each level, it was possible to place the central unit in a biomechanically stable environment to provide unhindered telemetry, while reaching the relevant target muscles for prosthetic control. At only the glenohumeral level, it was not possible to reach the teres major and latissimus dorsi muscles, which would require longer lead lengths. CONCLUSION: As assessed in a combination of animal model and cadaver research, the MIRA shows promise for clinical research in patients with limb amputation, where it may be employed for all levels of major upper limb amputation to provide long-term stable intramuscular EMG transmission. CLINICAL RELEVANCE: In our study, the MIRA provided high-bandwidth prosthetic interfacing through intramuscular electrode sites. Its high number of individual EMG channels may be combined with signal decoding algorithms for accessing spinal motor neuron activity after targeted muscle reinnervation, thus providing numerous degrees of freedom. Together with recent innovations in amputation surgery, the MIRA might enable improved control approaches for upper limb amputees, particularly for patients with above-elbow amputation where the mismatch between available control signals and necessary degrees of freedom for prosthetic control is highest.


Assuntos
Membros Artificiais , Animais , Cadáver , Cães , Eletrodos Implantados , Eletromiografia , Estudos de Viabilidade , Humanos , Inflamação , Coelhos , Ovinos
6.
J Neurosurg ; : 1-10, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36681968

RESUMO

OBJECTIVE: Until recently, autologous sensory nerve grafting has remained the gold-standard technique in peripheral nerve reconstruction. However, there are several disadvantages to these grafts, such as donor site morbidity, limited availability, and a qualitative mismatch. Building on this shortage, a new concept, the fascicular shift procedure, was proposed and successfully demonstrated nerve regeneration in a rat nerve injury model. This approach involves harvesting a fascicular group distal to a peripheral nerve injury and shifting it to bridge the defect. The present study aimed to evaluate the clinical applicability of this technique in brachial plexus reconstruction. METHODS: The supra- and infraclavicular nerves of the brachial plexus were bilaterally explored in 18 formalin-fixed cadaveric specimens. Following dissection, their fascicular shifting potential was evaluated. The medial antebrachial cutaneous and sural nerves were investigated and used as references for the required cross-sectional area of potential nerve grafts. Furthermore, 29 brachial plexus injuries, which qualified for surgical repair, were subjected to retrospective analysis. The intraoperatively measured lengths of the harvested and ultimately transplanted nerve grafts served as a basis to assess graft requirements in brachial plexus lesions. RESULTS: The transplanted nerve grafts measured a total length of 51.9 ± 28.1 cm in brachial plexus injuries. The individual inserted nerve grafts averaged 10.3 ± 5.1 cm. In the anatomical exploration, the ulnar and median nerves qualified for fascicular shifting. Their fascicular graft lengths measured 26.6 ± 2.5 cm and 24.8 ± 5.2 cm, respectively. The long thoracic, suprascapular, musculocutaneous, thoracodorsal, and axillary nerves were not suitable for fascicular shifting. The sensory graft length of the medial antebrachial cutaneous nerve measured 20.6 ± 3.4 cm. CONCLUSIONS: In the surgical reconstruction of brachial plexus injuries, fascicular shifting of the ulnar and median nerves provides sufficient donor material. Even though potential donor length is limited in the radial nerve, it may still help to expand the surgical armamentarium in selected clinical scenarios. Overall, the fascicular shift procedure presents a novel alternative to allow modality-matched grafting in the reconstruction of large proximal nerve defects and was found to be an attractive option in brachial plexus reconstruction.

7.
Elife ; 102021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34596042

RESUMO

Surgical nerve transfers are used to efficiently treat peripheral nerve injuries, neuromas, phantom limb pain, or improve bionic prosthetic control. Commonly, one donor nerve is transferred to one target muscle. However, the transfer of multiple nerves onto a single target muscle may increase the number of muscle signals for myoelectric prosthetic control and facilitate the treatment of multiple neuromas. Currently, no experimental models are available. This study describes a novel experimental model to investigate the neurophysiological effects of peripheral double nerve transfers to a common target muscle. In 62 male Sprague-Dawley rats, the ulnar nerve of the antebrachium alone (n=30) or together with the anterior interosseus nerve (n=32) was transferred to reinnervate the long head of the biceps brachii. Before neurotization, the motor branch to the biceps' long head was transected at the motor entry point. Twelve weeks after surgery, muscle response to neurotomy, behavioral testing, retrograde labeling, and structural analyses were performed to assess reinnervation. These analyses indicated that all nerves successfully reinnervated the target muscle. No aberrant reinnervation was observed by the originally innervating nerve. Our observations suggest a minimal burden for the animal with no signs of functional deficit in daily activities or auto-mutilation in both procedures. Furthermore, standard neurophysiological analyses for nerve and muscle regeneration were applicable. This newly developed nerve transfer model allows for the reliable and standardized investigation of neural and functional changes following the transfer of multiple donor nerves to one target muscle.


Assuntos
Músculo Esquelético/fisiologia , Transferência de Nervo/métodos , Traumatismos dos Nervos Periféricos/cirurgia , Nervos Periféricos/cirurgia , Animais , Membro Anterior/cirurgia , Masculino , Músculo Esquelético/cirurgia , Regeneração Nervosa/fisiologia , Ratos , Ratos Sprague-Dawley , Nervo Ulnar/cirurgia
8.
Front Neuroanat ; 15: 650761, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33828465

RESUMO

The facial dermato-muscular system consists of highly specialized muscles tightly adhering to the overlaying skin and thus form a complex morphological conglomerate. This is the anatomical and functional basis for versatile facial expressions, which are essential for human social interaction. The neural innervation of the facial skin and muscles occurs via branches of the trigeminal and facial nerves. These are also the most commonly pathologically affected cranial nerves, often requiring surgical treatment. Hence, experimental models for researching these nerves and their pathologies are highly relevant to study pathophysiology and nerve regeneration. Experimental models for the distinctive investigation of the complex afferent and efferent interplay within facial structures are scarce. In this study, we established a robust surgical model for distinctive exploration of facial structures after complete elimination of afferent or efferent innervation in the rat. Animals were allocated into two groups according to the surgical procedure. In the first group, the facial nerve and in the second all distal cutaneous branches of the trigeminal nerve were transected unilaterally. All animals survived and no higher burden was caused by the procedures. Whisker pad movements were documented with video recordings 4 weeks after surgery and showed successful denervation. Whole-mount immunofluorescent staining of facial muscles was performed to visualize the innervation pattern of the neuromuscular junctions. Comprehensive quantitative analysis revealed large differences in afferent axon counts in the cutaneous branches of the trigeminal nerve. Axon number was the highest in the infraorbital nerve (28,625 ± 2,519), followed by the supraorbital nerve (2,131 ± 413), the mental nerve (3,062 ± 341), and the cutaneous branch of the mylohyoid nerve (343 ± 78). Overall, this surgical model is robust and reliable for distinctive surgical deafferentation or deefferentation of the face. It may be used for investigating cortical plasticity, the neurobiological mechanisms behind various clinically relevant conditions like facial paralysis or trigeminal neuralgia as well as local anesthesia in the face and oral cavity.

9.
Orthopade ; 50(1): 14-23, 2021 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-33231741

RESUMO

BACKGROUND: After limb loss, it is the surgeon's task to provide the patient with a pain-free and resilient residual limb. Particularly in the upper extremity, there is an additional functional aspect, as appropriate muscle signals are needed to control myoelectric prostheses. Surgical management of peripheral nerves within the residual limb plays a central role both in terms of pain treatment as well as functional human-machine interfacing. OBJECTIVES: The presentation of current surgical procedures for dealing with peripheral nerves after limb amputation. MATERIAL AND METHODS: A literature search is carried out regarding the surgical prophylaxis and therapy of neuroma and phantom limb pain, as well as techniques to improve the functional interface between residual limb and prosthesis. Practical recommendations are formulated based on relevant literature, as well as the experiences of the authors. RESULTS AND CONCLUSIONS: There is a large number of different surgical techniques, particularly for the management of painful neuromas. Of the conventional methods, intramuscular implantation of the terminal nerves is commonly used with good results. Newer techniques such as targeted muscle reinnervation (TMR) and the regenerative peripheral nerve interface (RPNI) aim for the first time to provide functional end organs to the nerve even after amputation. In addition to the improved control of myoelectric prostheses, these methods further show excellent results for treatment and prevention of neuroma and phantom limb pain.


Assuntos
Cotos de Amputação/cirurgia , Nervos Periféricos/cirurgia , Membro Fantasma , Amputação Cirúrgica , Extremidades , Humanos
10.
Front Med (Lausanne) ; 7: 613138, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33363189

RESUMO

Introduction: Current imaging modalities for peripheral nerves display the nerve's structure but not its function. Based on a nerve's capacity for axonal transport, it may be visualized by targeted application of a contrast agent and assessing the distribution through radiological imaging, thus revealing a nerve's continuity. This concept has not been explored, however, may potentially guide the treatment of peripheral nerve injuries. In this experimental proof-of-concept study, we tested imaging through MRI after administering gadolinium-based contrast agents which were then retrogradely transported. Methods: We synthesized MRI contrast agents consisting of paramagnetic agents and various axonal transport facilitators (HSA-DTPA-Gd, chitosan-DTPA-Gd or PLA/HSA-DTPA-Gd). First, we measured their relaxivity values in vitro to assess their radiological suitability. Subsequently, the sciatic nerve of 24 rats was cut and labeled with one of the contrast agents to achieve retrograde distribution along the nerve. One week after surgery, the spinal cords and sciatic nerves were harvested to visualize the distribution of the respective contrast agent using 7T MRI. In vivo MRI measurements were performed using 9.4 T MRI on the 1st, 3rd, and the 7th day after surgery. Following radiological imaging, the concentration of gadolinium in the harvested samples was analyzed using inductively coupled mass spectrometry (ICP-MS). Results: All contrast agents demonstrated high relaxivity values, varying between 12.1 and 116.0 mM-1s-1. HSA-DTPA-Gd and PLA/HSA-DTPA-Gd application resulted in signal enhancement in the vertebral canal and in the sciatic nerve in ex vivo MRI. In vivo measurements revealed significant signal enhancement in the sciatic nerve on the 3rd and 7th day after HSA-DTPA-Gd and chitosan-DTPA-Gd (p < 0.05) application. Chemical evaluation showed high gadolinium concentration in the sciatic nerve for HSA-DTPA-Gd (5.218 ± 0.860 ng/mg) and chitosan-DTPA-Gd (4.291 ± 1.290 ng/mg). Discussion: In this study a novel imaging approach for the evaluation of a peripheral nerve's integrity was implemented. The findings provide radiological and chemical evidence of successful contrast agent uptake along the sciatic nerve and its distribution within the spinal canal in rats. This novel concept may assist in the diagnostic process of peripheral nerve injuries in the future.

11.
Wien Klin Wochenschr ; 131(23-24): 599-607, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31201567

RESUMO

BACKGROUND: Loss of an extremity at any level has a major impact on a patient's life. Using bionic reconstruction, extremity function can be restored and the patient reintegrated into daily life. Surgical procedures including selective nerve transfer and anchoring of prostheses into bone are combined with structured rehabilitation and modern prosthetic fitting. The patient is thereby able to use the prostheses intuitively and with multiple degrees of freedom. METHODS: This article presents the concept and approach for modern bionic reconstruction in detail and the relevant literature. The nerve transfer matrices for targeted muscle reinnervation (TMR) and the concept of osseointegration to optimally fit a patient with a modern prosthesis are described in detail. As a clinical example, the case of a patient who suffered from traumatic amputation and subsequently received TMR in combination with an osseointegrated implant and structured rehabilitation is presented. RESULTS: Using bionic reconstruction, basic hand functions can be restored and bimanual dexterity can expand the range of daily activities. Besides this approach to bionic reconstruction, its advantages and disadvantages are compared to hand transplantation. The limitations and perspectives of modern bionic reconstruction are also discussed. CONCLUSIONS: Bionic reconstruction is a sophisticated method for restoring extremity function and nowadays can be considered a standard of care for all levels of upper extremity amputations. An interdisciplinary approach and structured rehabilitation are necessary to master prosthetic function to ultimately reintegrate patients into daily life.


Assuntos
Amputação Cirúrgica/reabilitação , Membros Artificiais , Músculo Esquelético/inervação , Osseointegração , Extremidade Superior/cirurgia , Biônica , Humanos , Osseointegração/fisiologia , Desenho de Prótese , Implantação de Prótese , Procedimentos de Cirurgia Plástica/métodos
12.
Front Neurosci ; 13: 1442, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32116485

RESUMO

Introduction: Man-machine interfacing remains the main challenge for accurate and reliable control of bionic prostheses. Implantable electrodes in nerves and muscles may overcome some of the limitations by significantly increasing the interface's reliability and bandwidth. Before human application, experimental preclinical testing is essential to assess chronic in-vivo biocompatibility and functionality. Here, we analyze available animal models, their costs and ethical challenges in special regards to simulating a potentially life-long application in a short period of time and in non-biped animals. Methods: We performed a literature analysis following the PRISMA guidelines including all animal models used to record neural or muscular activity via implantable electrodes, evaluating animal models, group size, duration, origin of publication as well as type of interface. Furthermore, behavioral, ethical, and economic considerations of these models were analyzed. Additionally, we discuss experience and surgical approaches with rat, sheep, and primate models and an approach for international standardized testing. Results: Overall, 343 studies matched the search terms, dominantly originating from the US (55%) and Europe (34%), using mainly small animal models (rat: 40%). Electrode placement was dominantly neural (77%) compared to muscular (23%). Large animal models had a mean duration of 135 ± 87.2 days, with a mean of 5.3 ± 3.4 animals per trial. Small animal models had a mean duration of 85 ± 11.2 days, with a mean of 12.4 ± 1.7 animals. Discussion: Only 37% animal models were by definition chronic tests (>3 months) and thus potentially provide information on long-term performance. Costs for large animals were up to 45 times higher than small animals. However, costs are relatively small compared to complication costs in human long-term applications. Overall, we believe a combination of small animals for preliminary primary electrode testing and large animals to investigate long-term biocompatibility, impedance, and tissue regeneration parameters provides sufficient data to ensure long-term human applications.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...