1.
Appl Radiat Isot ; 182: 110077, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35121275

RESUMO

As a consequence of the Chernobyl accident in 1986 the Integrated Measurement and Information System (IMIS) was established (Weiss and Leeb, 1993) which includes on-line monitoring networks for the surveillance of radioactivity in Germany. Today, the German Federal Office for Radiation Protection (BfS) operates a gamma dose rate network with 1800 ambient dose equivalent rate H*(10) (ADER) stations almost equally distributed over the German territory. The ADER network integrates Geiger-Müller (GM) based detectors which, if low and high dose rate tubes are combined, are known to have excellent long-term stability and an extended dose rate range from environmental background level (20 nSv/h) up to several Sv/h. However, one main drawback is the lack of information about nuclides contributing to the observed dose rate. Therefore BfS has started to integrate LaBr3-based spectrometric detector systems (so-called spectro-dosemeters) in the existing ADER network. In this paper detector design, quality assurance and quality control (QA/QC) procedures are described as well as efforts required to characterize and operate monitoring networks based on spectrometric detectors.


Assuntos
Dosímetros de Radiação , Monitoramento de Radiação/métodos , Alemanha , Doses de Radiação , Monitoramento de Radiação/instrumentação
SELEÇÃO DE REFERÊNCIAS