1.
Quant Imaging Med Surg ; 11(4): 1470-1482, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33816183

RESUMO

BACKGROUND: Left ventricular (LV) kinetic energy (KE) assessment by four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) may offer incremental value over routine assessment in aortic stenosis (AS). The main objective of this study is to investigate the LV KE in patients with AS before and after the valve intervention. In addition, this study aimed to investigate if LV KE offers incremental value for its association to the six-minute walk test (6MWT) or LV remodelling post-intervention. METHODS: We recruited 18 patients with severe AS. All patients underwent transthoracic echocardiography for mean pressure gradient (mPG), CMR including 4D flow and 6MWT. Patients were invited for post-valve intervention follow-up CMR at 3 months and twelve patients returned for follow-up CMR. KE assessment of LV blood flow and the components (direct, delayed, retained and residual) were carried out for all cases. LV KE parameters were normalised to LV end-diastolic volume (LVEDV). RESULTS: For LV blood flow KE assessment, the metrics including time delay (TD) for peak E-wave from base to mid-ventricle (14±48 vs. 2.5±9.75 ms, P=0.04), direct (4.91±5.07 vs. 1.86±1.72 µJ, P=0.01) and delayed (2.46±3.13 vs. 1.38±1.15 µJ, P=0.03) components of LV blood flow demonstrated a significant change between pre- and post-valve intervention. Only LV KEiEDV (r=-0.53, P<0.01), diastolic KEiEDV (r=-0.53, P<0.01) and Ewave KEiEDV (r=-0.38, P=0.04) demonstrated association to the 6MWT. However, Pre-operative LV KEiEDV (r=0.67, P=0.02) demonstrated association to LV remodelling post valve intervention. CONCLUSIONS: LV blood flow KE is associated with 6MWT and LV remodelling in patients with AS. LV KE assessment provides incremental value over routine LV function and pressure gradient (PG) assessment in AS.

2.
Int J Cardiol ; 331: 316-321, 2021 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-33548381

RESUMO

BACKGROUND: There are several methods to quantify mitral regurgitation (MR) by cardiovascular magnetic resonance (CMR). The interoperability of these methods and their reproducibility remains undetermined. OBJECTIVE: To determine the agreement and reproducibility of different MR quantification methods by CMR across all aetiologies. METHODS: Thirty-five patients with MR were recruited (primary MR = 12, secondary MR = 10 and MVR = 13). Patients underwent CMR, including cines and four-dimensional flow (4D flow). Four methods were evaluated: MRStandard (left ventricular stroke volume - aortic forward flow by phase contrast), MRLVRV (left ventricular stroke volume - right ventricular stroke volume), MRJet (direct jet quantification by 4D flow) and MRMVAV (mitral forward flow by 4D flow - aortic forward flow by 4D flow). For all cases and MR types, 520 MR volumes were recorded by these 4 methods for intra-/inter-observer tests. RESULTS: In primary MR, MRMVAV and MRLVRV were comparable to MRStandard (P > 0.05). MRJet resulted in significantly higher MR volumes when compared to MRStandard (P < 0.05) In secondary MR and MVR cases, all methods were comparable. In intra-observer tests, MRMVAV demonstrated least bias with best limits of agreement (bias = -0.1 ml, -8 ml to 7.8 ml, P = 0.9) and best concordance correlation coefficient (CCC = 0.96, P < 0.01). In inter-observer tests, for primary MR and MVR, least bias and highest CCC were observed for MRMVAV. For secondary MR, bias was lowest for MRJet (-0.1 ml, PNS). CONCLUSION: CMR methods of MR quantification demonstrate agreement in secondary MR and MVR. In primary MR, this was not observed. Across all types of MR, MRMVAV quantification demonstrated the highest reproducibility and consistency.


Assuntos
Insuficiência da Valva Mitral , Humanos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Insuficiência da Valva Mitral/diagnóstico por imagem , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
3.
JACC Cardiovasc Imaging ; 14(7): 1354-1366, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33582060

RESUMO

OBJECTIVES: This study determined: 1) the interobserver agreement; 2) valvular flow variation; and 3) which variables independently predicted the variation of valvular flow quantification from 4-dimensional (4D) flow cardiac magnetic resonance (CMR) with automated retrospective valve tracking at multiple sites. BACKGROUND: Automated retrospective valve tracking in 4D flow CMR allows consistent assessment of valvular flow through all intracardiac valves. However, due to the variance of CMR scanners and protocols, it remains uncertain if the published consistency holds for other clinical centers. METHODS: Seven sites each retrospectively or prospectively selected 20 subjects who underwent whole heart 4D flow CMR (64 patients and 76 healthy volunteers; aged 32 years [range 24 to 48 years], 47% men, from 2014 to 2020), which was acquired with locally used CMR scanners (scanners from 3 vendors; 2 1.5-T and 5 3-T scanners) and protocols. Automated retrospective valve tracking was locally performed at each site to quantify the valvular flow and repeated by 1 central site. Interobserver agreement was evaluated with intraclass correlation coefficients (ICCs). Net forward volume (NFV) consistency among the valves was evaluated by calculating the intervalvular variation. Multiple regression analysis was performed to assess the predicting effect of local CMR scanners and protocols on the intervalvular inconsistency. RESULTS: The interobserver analysis demonstrated strong-to-excellent agreement for NFV (ICC: 0.85 to 0.96) and moderate-to-excellent agreement for regurgitation fraction (ICC: 0.53 to 0.97) for all sites and valves. In addition, all observers established a low intervalvular variation (≤10.5%) in their analysis. The availability of 2 cine images per valve for valve tracking compared with 1 cine image predicted a decreasing variation in NFV among the 4 valves (beta = -1.3; p = 0.01). CONCLUSIONS: Independently of locally used CMR scanners and protocols, valvular flow quantification can be performed consistently with automated retrospective valve tracking in 4D flow CMR.


Assuntos
Estudos Retrospectivos , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes
4.
Wellcome Open Res ; 6: 253, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-37250619

RESUMO

Background: The reproducibility of mitral regurgitation (MR) quantification by cardiovascular magnetic resonance (CMR) imaging using different software solutions remains unclear. This research aimed to investigate the reproducibility of MR quantification between two software solutions: MASS (version 2019 EXP, LUMC, Netherlands) and CAAS (version 5.2, Pie Medical Imaging). Methods: CMR data of 35 patients with MR (12 primary MR, 13 mitral valve repair/replacement, and ten secondary MR) was used. Four methods of MR volume quantification were studied, including two 4D-flow CMR methods (MR MVAV and MR Jet) and two non-4D-flow techniques (MR Standard and MR LVRV). We conducted within-software and inter-software correlation and agreement analyses. Results: All methods demonstrated significant correlation between the two software solutions: MR Standard (r=0.92, p<0.001), MR LVRV (r=0.95, p<0.001), MR Jet (r=0.86, p<0.001), and MR MVAV (r=0.91, p<0.001). Between CAAS and MASS, MR Jet and MR MVAV, compared to each of the four methods, were the only methods not to be associated with significant bias. Conclusions: We conclude that 4D-flow CMR methods demonstrate equivalent reproducibility to non-4D-flow methods but greater levels of agreement between software solutions.

5.
Sci Rep ; 10(1): 10569, 2020 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-32601326

RESUMO

The management of patients with aortic stenosis (AS) crucially depends on accurate diagnosis. The main aim of this study were to validate the four-dimensional flow (4D flow) cardiovascular magnetic resonance (CMR) methods for AS assessment. Eighteen patients with clinically severe AS were recruited. All patients had pre-valve intervention 6MWT, echocardiography and CMR with 4D flow. Of these, ten patients had a surgical valve replacement, and eight patients had successful transcatheter aortic valve implantation (TAVI). TAVI patients had invasive pressure gradient assessments. A repeat assessment was performed at 3-4 months to assess the remodelling response. The peak pressure gradient by 4D flow was comparable to an invasive pressure gradient (54 ± 26 mmHG vs 50 ± 34 mmHg, P = 0.67). However, Doppler yielded significantly higher pressure gradient compared to invasive assessment (61 ± 32 mmHG vs 50 ± 34 mmHg, P = 0.0002). 6MWT was associated with 4D flow CMR derived pressure gradient (r = -0.45, P = 0.01) and EOA (r = 0.54, P < 0.01) but only with Doppler EOA (r = 0.45, P = 0.01). Left ventricular mass regression was better associated with 4D flow derived pressure gradient change (r = 0.64, P = 0.04). 4D flow CMR offers an alternative method for non-invasive assessment of AS. In addition, 4D flow derived valve metrics have a superior association to prognostically relevant 6MWT and LV mass regression than echocardiography.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Sistema Cardiovascular/fisiopatologia , Ecocardiografia/métodos , Ecocardiografia Doppler/métodos , Feminino , Tomografia Computadorizada Quadridimensional , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Volume Sistólico/fisiologia , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Função Ventricular Esquerda/fisiologia
6.
Sci Rep ; 10(1): 9908, 2020 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-32555252

RESUMO

Assessment of right ventricular (RV) diastolic function is not routinely carried out. This is due to standard two-dimensional imaging techniques being unreliable. Four-dimensional flow (4D flow) derived right ventricular blood flow kinetic energy assessment could circumvent the issues of the current imaging modalities. It also remains unknown whether there is an association between right ventricular blood flow kinetic energy (KE) and healthy ageing. We hypothesise that healthy ageing requires maintaining normal RV intra-cavity blood flow as quantified using KE method. The main objective of this study was to investigate the effect of healthy ageing on tricuspid through-plane flow and right ventricular blood flow kinetic energy. In this study, fifty-three healthy participants received a 4D flow cardiovascular magnetic resonance (CMR) scan on 1.5 T Philips Ingenia. Cine segmentation and 4D flow analysis were performed using dedicated software. Standard statistical methods were carried out to investigate the associations. Both RV E-wave KEiEDV (r = -0.3, P = 0.04) and A-wave KEiEDV (r = 0.42, P < 0.01) showed an association with healthy ageing. Additionally, the right ventricular blood flow KEiEDV E/A ratio demonstrated the strongest association with healthy ageing (r = -0.53, P < 0.01) when compared to all RV functional and haemodynamic parameters. Furthermore, in a multivariate regression model, KEiEDV E/A ratio and 4D flow derived tricuspid valve stroke volume demonstrated independent association to healthy ageing (beta -0.02 and 0.68 respectively, P < 0.01). Ageing is independently associated with 4D flow derived tricuspid stroke volume and RV blood flow KE E/A ratio. These novel 4D flow CMR derived imaging markers have future potential for RV diastolic assessment.


Assuntos
Velocidade do Fluxo Sanguíneo , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Valva Tricúspide/fisiologia , Disfunção Ventricular Direita/fisiopatologia , Função Ventricular Direita/fisiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Adulto Jovem
7.
Front Cardiovasc Med ; 6: 103, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31428619

RESUMO

Background: Four-dimensional flow cardiac magnetic resonance (4D flow CMR) is an emerging non-invasive imaging technology that can be used to quantify mitral regurgitation (MR) volume. Current methods of quantification have demonstrated limitations in accurate analysis, particularly in difficult cases such as complex congenital heart disease. 4D flow CMR methods aim to circumvent these limitations and allow accurate quantification of MR volume even in complex cases. This systematic review aims to summarize the available literature on 4D flow CMR MR quantification methods and examine their ability to accurately classify MR severity. Methods: Structured searches were carried out on Medline and EMBASE in December 2018 to identify suitable research outcome studies. The titles and abstracts were screened for relevance, with a third adjudicator utilized when study suitability was uncertain. Results: Seven studies met the eligibility criteria and were included in the systematic review. The most widely used 4D flow MRI method was retrospective valve tracking (RVT) which was examined in five papers. The key finding of these papers was that RVT is a reliable and accurate method of regurgitant volume quantification. Conclusions: MR quantification through 4D flow MRI is both feasible and accurate. The evidence gathered suggests that for MR assessment, 4D flow MRI is potentially as accurate and reliable to echocardiography and may be complementary to this technique. Further work on MR quantification 4D flow image analysis is needed to determine the most accurate analysis technique and to demonstrate 4D flow MRI as a predictor of clinical outcome. PROSPERO Registration Number: CRD42019122837, http://www.crd.york.ac.uk/PROSPERO/display_record.php?ID=CRD42019122837.

8.
Biomed Res Int ; 2019: 6074984, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31001557

RESUMO

BACKGROUND: Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) is a noninvasive novel imaging technology that can be used to visualise and assess right ventricular function. The aim of this systematic review is to summarise the literature available on 4D flow CMR methods used to determine right ventricular diastolic function. METHODS: A systematic review of current literature was carried out to ascertain what is known about right ventricular assessment by quantification of 4D flow CMR. Structured searches were carried out on Medline and EMBASE in December 2018. PG and NB screened the titles and abstracts for relevance. RESULTS: Of the 20 articles screened, 5 studies met eligibility for systematic review. After a further search on pubmed 1 more relevant article was found and added to the review. CONCLUSIONS: These proposed methods using 4D flow CMR can quantify right ventricular diastolic assessment. The evidence gathered is mainly observational, featuring single-centred studies. Larger, multicentre studies are required to validate the proposed techniques, evaluate reproducibility, and investigate the clinical applicability that 4D flow CMR offers compared to standard practices. PROSPERO registration number is CRD42019121492.


Assuntos
Diástole , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética , Função Ventricular Direita , Feminino , Humanos , Masculino