Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Magn Reson Med ; 75(6): 2324-31, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26115021

RESUMO

PURPOSE: Simultaneous acquisition of spatially resolved (31) P-MRI data for evaluation of muscle specific energy metabolism, i.e., PCr and pH kinetics. METHODS: A three-dimensional (3D) gradient-echo sequence for multiple frequency-selective excitations of the PCr and Pi signals in an interleaved sampling scheme was developed and tested at 7 Tesla (T). The pH values were derived from the chemical shift-induced phase difference between the resonances. The achieved spatial resolution was ∼2 mL with image acquisition time below 6 s. Ten healthy volunteers were studied performing plantar flexions during the delay between (31) P-MRI acquisitions, yielding a temporal resolution of 9-10 s. RESULTS: Signal from anatomically matched regions of interest had sufficient signal-to-noise ratio to allow single-acquisition PCr and pH quantification. The Pi signal was clearly detected in voxels of actively exercising muscles. The PCr depletions were in gastrocnemius 42 ± 14% (medialis), 48 ± 17% (lateralis) and in soleus 20 ± 11%. The end exercise pH values were 6.74 ± 0.18 and 6.65 ± 0.27 for gastrocnemius medialis and lateralis, respectively, and 6.96 ± 0.12 for soleus muscle. CONCLUSION: Simultaneous acquisition of PCr and Pi images with high temporal resolution, suitable for measuring PCr and pH kinetics in exercise-recovery experiments, was demonstrated at 7T. This study presents a fast alternative to MRS for quantifying energy metabolism of posterior muscle groups of the lower leg. Magn Reson Med 75:2324-2331, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Exercício Físico/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Músculo Esquelético/diagnóstico por imagem , Fosfocreatina/metabolismo , Adulto , Feminino , Humanos , Concentração de Íons de Hidrogênio , Masculino , Músculo Esquelético/metabolismo , Músculo Esquelético/fisiologia , Fosfocreatina/análise , Isótopos de Fósforo/metabolismo , Razão Sinal-Ruído , Adulto Jovem
2.
Magn Reson Med ; 73(3): 1190-5, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24752959

RESUMO

PURPOSE: The aim of this study was to develop a measurement protocol for noninvasive simultaneous perfusion quantification and T2 *-weighted MRI acquisition in the exercising calf muscle at 7 Tesla. METHODS: Using a nonmagnetic ergometer and a dedicated in-house built calf coil array, dynamic pulsed arterial spin labeling (PASL) measurements with a temporal resolution of 12 s were performed before, during, and after plantar flexion exercise in 16 healthy volunteers. RESULTS: Postexercise peak perfusion in gastrocnemius muscle (GAS) was 27 ± 16 ml/100g/min, whereas in soleus (SOL) and tibialis anterior (TA) muscles it remained at baseline levels. T2 *-weighted and ASL time courses in GAS showed comparable times to peak of 161 ± 72 s and 167 ± 115 s, respectively. The T2 *-weighted signal in the GAS showed a minimum during exercise (88 ± 6 % of the baseline signal) and a peak during the recovery (122 ± 9%), whereas in all other muscles only a signal decrease was observed (minimum 91 ± 6% in SOL; 87 ± 8% in TA). CONCLUSION: We demonstrate the feasibility of dynamic perfusion quantification in skeletal muscle at 7 Tesla using PASL. This may help to better investigate the physiological processes in the skeletal muscle and also in diseases such as diabetes mellitus and peripheral arterial disease.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Imagem de Difusão por Ressonância Magnética/métodos , Exercício Físico/fisiologia , Angiografia por Ressonância Magnética/métodos , Músculo Esquelético/fisiologia , Esforço Físico/fisiologia , Adulto , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Perna (Membro) , Masculino , Músculo Esquelético/irrigação sanguínea , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
NMR Biomed ; 27(5): 553-60, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24610788

RESUMO

Skeletal muscle metabolism is impaired in disorders like diabetes mellitus or peripheral vascular disease. The skeletal muscle echo planar imaging (EPI) signal (S(EPI) ) and its relation to energy metabolism are still debated. Localised ³¹P MRS and S(EPI) data from gastrocnemius medialis of 19 healthy subjects were combined in one scanning session to study direct relationships between phosphocreatine (PCr), pH kinetics and parameters of T2∗ time courses. Dynamic spectroscopy (semi-LASER) and EPI were performed immediately before, during and after 5 min of plantar flexions. Data were acquired in a 7 T MR scanner equipped with a custom-built ergometer and a dedicated ³¹P/¹H radio frequency (RF) coil array. Using a form-fitted multi-channel ³¹P/¹H coil array resulted in high signal-to-noise ratio (SNR). PCr and pH in the gastrocnemius medialis muscle were quantified from each ³¹P spectrum, acquired every 6 s. During exercise, SEPI (t) was found to be a linear function of tissue pH(t) (cross-correlation r = -0.85 ± 0.07). Strong Pearson's correlations were observed between post exercise time-to-peak (TTP) of SEPI and (a) the time constant of PCr recovery τPCr recovery (r = 0.89, p < 10⁻6), (b) maximum oxidative phosphorylation using the linear model, Q(max, lin) (r = 0.65, p = 0.002), the adenosine-diphosphate-driven model, Q(max,ADP) (r = 0.73, p = 0.0002) and (c) end exercise pH (r = 0.60, p = 0.005). Based on combined accurately localised ³¹P MRS and T2∗ weighted MRI, both with high temporal resolution, strong correlations of the skeletal muscle SEPI during exercise and tissue pH time courses and of post exercise SEPI and parameters of energy metabolism were observed. In conclusion, a tight coupling between skeletal muscle metabolic activity and tissue T2∗ signal weighting, probably induced by osmotically driven water shift, exists and can be measured non-invasively, using NMR at 7 T.


Assuntos
Exercício Físico/fisiologia , Perna (Membro)/fisiologia , Imageamento por Ressonância Magnética , Músculo Esquelético/fisiologia , Fosforilação Oxidativa , Fosfocreatina/metabolismo , Adulto , Demografia , Imagem Ecoplanar , Feminino , Humanos , Concentração de Íons de Hidrogênio , Masculino , Fosfocreatina/análogos & derivados , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA