Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Magn Reson Med ; 89(1): 469-476, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36089826

RESUMO

PURPOSE: This study aims to find a relation between the number of channels and the computational burden for specific absorption rate (SAR) calculation using virtual observation point-based SAR compression. METHODS: Eleven different arrays of rectangular loops covering a cylinder of fixed size around the head of an anatomically correct voxel model were simulated. The resulting Q-matrices were compressed with 2 different compression algorithms, with the overestimation fixed to a certain fraction of worst-case SAR, median SAR, or minimum SAR. The latter 2 were calculated from 1e6 normalized random excitation vectors. RESULTS: The number of virtual observation points increased with the number of channels to the power of 2.3-3.7, depending on the compression algorithm when holding the relative error fixed. Together with the increase in the size of the Q-matrices (and therefore the size of the virtual observation points), the total increase in computational burden with the number of channels was to the power of 4.3-5.7. CONCLUSION: The computational cost emphasizes the need to use the best possible compression algorithms when moving to high channel counts.


Assuntos
Compressão de Dados , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Algoritmos , Simulação por Computador , Imagens de Fantasmas
2.
NMR Biomed ; 35(8): e4722, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35226966

RESUMO

Longitudinally orientated dipoles and microstrip antennas have both demonstrated superior results as RF transmit elements for body imaging at 7 T MRI, and are as of today the most commonly used transmit elements. In this study, the performances of the two antenna concepts were compared for use in local RF antenna arrays by numerical simulations. Antenna elements investigated are the fractionated dipole and the microstrip line with meander structures. Phantom simulations with a single antenna element were performed and evaluated with regard to specific absorption rate (SAR) efficiency in the center of the subject. Simulations of array configurations with 8 and 16 elements were performed with anatomical body models. Both antenna elements were combined with a loop coil to compare hybrid configurations. Singular value decomposition of the B1+ fields, RF shimming, and calculation of the voxel-wise power and SAR efficiencies were performed in regions of interest with varying sizes to evaluate the transmit performance. The signal-to-noise ratio (SNR) was evaluated to estimate the receive performance. Simulated data show similar transmit profiles for the two antenna types in the center of the phantom (penetration depth > 20 mm). For body imaging, no considerable differences were determined for the different antenna configurations with regard to the transmit performance. Results show the advantage of 16 transmit channels compared with today's commonly used 8-channel systems (minimum RF shimming excitation error of 4.7% (4.3%) versus 2.7% (2.8%) for the 8-channel and 16-channel configurations with the microstrip antennas in a (5 cm)3 cube in the center of a male (female) body model). Highest SNR is achieved for the 16-channel configuration with fractionated dipoles. The combination of either fractionated dipoles or microstrip antennas with loop coils is more favorable with regard to the transmit performance compared with only increasing the number of elements.


Assuntos
Imageamento por Ressonância Magnética , Modelos Anatômicos , Desenho de Equipamento , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Masculino , Imagens de Fantasmas , Razão Sinal-Ruído
3.
NMR Biomed ; 35(5): e4656, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34962689

RESUMO

In this study, the performance of an integrated body-imaging array for 7 T with 32 radiofrequency (RF) channels under consideration of local specific absorption rate (SAR), tissue temperature, and thermal dose limits was evaluated and the imaging performance was compared with a clinical 3 T body coil. Thirty-two transmit elements were placed in three rings between the bore liner and RF shield of the gradient coil. Slice-selective RF pulse optimizations for B1 shimming and spokes were performed for differently oriented slices in the body under consideration of realistic constraints for power and local SAR. To improve the B1+ homogeneity, safety assessments based on temperature and thermal dose were performed to possibly allow for higher input power for the pulse optimization than permissible with SAR limits. The results showed that using two spokes, the 7 T array outperformed the 3 T birdcage in all the considered regions of interest. However, a significantly higher SAR or lower duty cycle at 7 T is necessary in some cases to achieve similar B1+ homogeneity as at 3 T. The homogeneity in up to 50 cm-long coronal slices can particularly benefit from the high RF shim performance provided by the 32 RF channels. The thermal dose approach increases the allowable input power and the corresponding local SAR, in one example up to 100 W/kg, without limiting the exposure time necessary for an MR examination. In conclusion, the integrated antenna array at 7 T enables a clinical workflow for body imaging and comparable imaging performance to a conventional 3 T clinical body coil.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Temperatura
4.
Magn Reson Med ; 86(5): 2853-2861, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34216047

RESUMO

PURPOSE: Compression of local specific absorption rate (SAR) matrices is essential for enabling SAR monitoring and efficient pulse calculation in parallel transmission. Improvements in compression result in lower error margin and/or lower number of virtual observation points (VOPs). The purpose of this work is to introduce two algorithms for post-processing of already compressed VOP sets. One calculates individual overestimation matrices for the VOPs to reduce overestimation, the other identifies redundant VOPs. METHODS: The first algorithm was evaluated for VOP sets calculated for three different transmit arrays with either 8 or 16 channels. For each array, two different overestimation matrices were used to generate the VOP sets. Each post-processed VOP set was evaluated using one million random excitation vectors and the results compared to the VOP set before post-processing. The second algorithm was evaluated by utilizing the same random excitation vectors and comparing the results after removal of the redundant VOPs with the results before removal to verify that these were identical. RESULTS: The first algorithm reduced the mean overestimation by up to four fifths compared to the original set, while keeping the number of VOPs constant. The second algorithm decreased the number of VOPs generated by a compression with Eichfelder and Gebhardt's algorithm by more than 40% in 40% of the investigated cases and by more than 20% in 73% of the investigated cases. CONCLUSION: Two post-processing algorithms are presented that enhance previously compressed VOP sets by improving the accuracy per number of VOPs.


Assuntos
Compressão de Dados , Imageamento por Ressonância Magnética , Algoritmos , Imagens de Fantasmas
5.
NMR Biomed ; 34(7): e4515, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33942938

RESUMO

The aim of the current study was to investigate the performance of integrated RF transmit arrays with high channel count consisting of meander microstrip antennas for body imaging at 7 T and to optimize the position and number of transmit elements. RF simulations using multiring antenna arrays placed behind the bore liner were performed for realistic exposure conditions for body imaging. Simulations were performed for arrays with as few as eight elements and for arrays with high channel counts of up to 48 elements. The B1+ field was evaluated regarding the degrees of freedom for RF shimming in the abdomen. Worst-case specific absorption rate (SARwc ), SAR overestimation in the matrix compression, the number of virtual observation points (VOPs) and SAR efficiency were evaluated. Constrained RF shimming was performed in differently oriented regions of interest in the body, and the deviation from a target B1+ field was evaluated. Results show that integrated multiring arrays are able to generate homogeneous B1+ field distributions for large FOVs, especially for coronal/sagittal slices, and thus enable body imaging at 7 T with a clinical workflow; however, a low duty cycle or a high SAR is required to achieve homogeneous B1+ distributions and to exploit the full potential. In conclusion, integrated arrays allow for high element counts that have high degrees of freedom for the pulse optimization but also produce high SARwc , which reduces the SAR accuracy in the VOP compression for low-SAR protocols, leading to a potential reduction in array performance. Smaller SAR overestimations can increase SAR accuracy, but lead to a high number of VOPs, which increases the computational cost for VOP evaluation and makes online SAR monitoring or pulse optimization challenging. Arrays with interleaved rings showed the best results in the study.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Ondas de Rádio , Simulação por Computador , Humanos , Masculino , Modelos Biológicos
6.
Magn Reson Med ; 86(1): 561-568, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33634530

RESUMO

PURPOSE: Local specific absorption rate (SAR) compression algorithms are essential for enabling online SAR monitoring in parallel transmission. A better compression resulting in a lower number of virtual observation points improves speed of SAR calculation for online supervision and pulse design. METHOD: An iterative expansion of an existing algorithm presented by Lee et al is proposed in this work. The original algorithm is used within a loop, making use of the virtual observation points from the previous iteration as the starting subvolume, while decreasing the overestimation with each iteration. This algorithm is evaluated on the SAR matrices of three different simulated arrays. RESULT: The number of virtual observation points is approximately halved with the new algorithm, while at the same time the compression time is reduced with speed-up factors of up to 2.5. CONCLUSION: The new algorithm improves the original algorithm in terms of compression rate and speed.


Assuntos
Compressão de Dados , Imageamento por Ressonância Magnética , Algoritmos
7.
MAGMA ; 34(1): 153-163, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32964299

RESUMO

OBJECTIVE: In local SAR compression algorithms, the overestimation is generally not linearly dependent on actual local SAR. This can lead to large relative overestimation at low actual SAR values, unnecessarily constraining transmit array performance. METHOD: Two strategies are proposed to reduce maximum relative overestimation for a given number of VOPs. The first strategy uses an overestimation matrix that roughly approximates actual local SAR; the second strategy uses a small set of pre-calculated VOPs as the overestimation term for the compression. RESULT: Comparison with a previous method shows that for a given maximum relative overestimation the number of VOPs can be reduced by around 20% at the cost of a higher absolute overestimation at high actual local SAR values. CONCLUSION: The proposed strategies outperform a previously published strategy and can improve the SAR compression where maximum relative overestimation constrains the performance of parallel transmission.


Assuntos
Compressão de Dados , Algoritmos , Simulação por Computador , Imageamento por Ressonância Magnética , Imagens de Fantasmas
8.
Materials (Basel) ; 13(22)2020 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-33182725

RESUMO

The number of shark attacks resulting in fatalities and severe injuries has increased steadily over recent years. This is mainly attributed to a growing population participating in ocean sports such as swimming, diving, and surfing. To mitigate the severity of shark attacks, the current study presents a novel fibre-reinforced composite for bite protection. This material is intended for integration into neoprene wetsuits, e.g., in the form of protective pads. A suitable material must be able to withstand significant bite forces, which are concentrated within a small contact area at the tips of the shark teeth. At the same time, the material should not hinder the complex motion sequences of aquatic sports. To this end, a novel fibre-reinforced composite was created by integrating Kevlar fibres into an elastic matrix. Uni-axial testing using shark teeth replicas was conducted on a specially designed test rig to quantify the effectiveness of the novel protective material.

9.
FEBS Lett ; 2020 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-32298460

RESUMO

Coronin proteins are widely expressed among eukaryotic organisms. Most coronins consist of a WD-repeat domain followed by a C-terminal coiled coil. Dictyostelium discoideum expresses a single short coronin coronin A, which has been implicated in both actin modulation and multicellular differentiation. Whether coronin A's coiled coil is important for functionality, as well as the oligomeric state of coronin A is not known. Here, we show that the coiled-coil domain in Dictyostelium coronin A functions in homodimerization, is dispensable for coronin A stability and localization but essential for multicellular differentiation. These results allow a better understanding of the role for the coiled-coil domain of coronin A in oligomerization and demonstrate that its presence is essential for multicellular differentiation.

10.
Int J Mol Sci ; 21(4)2020 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-32098122

RESUMO

Coronin proteins are evolutionary conserved WD repeat containing proteins that have been proposed to carry out different functions. In Dictyostelium, the short coronin isoform, coronin A, has been implicated in cytoskeletal reorganization, chemotaxis, phagocytosis and the initiation of multicellular development. Generally thought of as modulators of F-actin, coronin A and its mammalian homologs have also been shown to mediate cellular processes in an F-actin-independent manner. Therefore, it remains unclear whether or not coronin A carries out its functions through its capacity to interact with F-actin. Moreover, the interacting partners of coronin A are not known. Here, we analyzed the interactome of coronin A as well as its interaction with F-actin within cells and in vitro. Interactome analysis showed the association with a diverse set of interaction partners, including fimbrin, talin and myosin subunits, with only a transient interaction with the minor actin10 isoform, but not the major form of actin, actin8, which was consistent with the absence of a coronin A-actin interaction as analyzed by co-sedimentation from cells and lysates. In vitro, however, purified coronin A co-precipitated with rabbit muscle F-actin in a coiled-coil-dependent manner. Our results suggest that an in vitro interaction of coronin A and rabbit muscle actin may not reflect the cellular interaction state of coronin A with actin, and that coronin A interacts with diverse proteins in a time-dependent manner.


Assuntos
Actinas/metabolismo , Dictyostelium/metabolismo , Proteínas dos Microfilamentos/metabolismo , Proteínas de Protozoários/metabolismo , Animais , Coelhos
11.
PLoS One ; 14(9): e0222452, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31513637

RESUMO

PURPOSE: A 32-channel parallel transmit (pTx) add-on for 7 Tesla whole-body imaging is presented. First results are shown for phantom and in-vivo imaging. METHODS: The add-on system consists of a large number of hardware components, including modulators, amplifiers, SAR supervision, peripheral devices, a control computer, and an integrated 32-channel transmit/receive body array. B1+ maps in a phantom as well as B1+ maps and structural images in large volunteers are acquired to demonstrate the functionality of the system. EM simulations are used to ensure safe operation. RESULTS: Good agreement between simulation and experiment is shown. Phantom and in-vivo acquisitions show a field of view of up to 50 cm in z-direction. Selective excitation with 100 kHz sampling rate is possible. The add-on system does not affect the quality of the original single-channel system. CONCLUSION: The presented 32-channel parallel transmit system shows promising performance for ultra-high field whole-body imaging.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Humanos , Imagens de Fantasmas , Razão Sinal-Ruído
12.
Materials (Basel) ; 12(5)2019 Mar 07.
Artigo em Inglês | MEDLINE | ID: mdl-30866504

RESUMO

Zinc alloy (ZA27) syntactic foams (SF) were manufactured using expanded perlite (EP) particles and counter-gravity infiltration casting. Due to a variation of the metallic matrix content, the density of the produced foam samples varied from 1.78 to 2.03 g·cm-3. As-cast and solution heat-treated samples were tested to investigate the compressive properties of the ZA27 syntactic foam. To this end, quasi-static compression tests were conducted. In addition, microstructural analysis of the as-cast and heat-treated syntactic foams was carried out using scanning electron microscopy. The results indicate that the heat treatment alters the microstructure of the ZA27 alloy matrix from a multiphase dendrite to a spheroidized microstructure with improved ductility. Moreover, the heat treatment considerably enhances the energy absorption and plateau stress ( σ pl ) of the syntactic foam. Optical analysis of the syntactic foams under compression shows that the dominant deformation mechanism of the as-cast foams is brittle fracture. In comparison, the heat-treated samples undergo a more ductile deformation.

13.
Materials (Basel) ; 12(1)2018 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-30577425

RESUMO

In this study, activated carbon (AC) particles were combined with AZ91 alloy to manufacture a magnesium syntactic foam. This novel lightweight foam has a very low density, in the range of 1.12⁻1.18 gcm-3. The results show that no chemical reaction occurred between the AZ91 matrix and the activated carbon particles. The mechanical properties of the foam were evaluated under quasi-static compression loading conditions, and showed a consistent trend for the energy absorption of the fabricated AZ91⁻AC syntactic foams. The deformation mechanism of samples was a brittle fracture mode with the formation of shear bands during the fracture of all samples.

15.
Neuroimage ; 168: 33-58, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28336426

RESUMO

At ultra-high fields, the assessment of radiofrequency (RF) safety presents several new challenges compared to low-field systems. Multi-channel RF transmit coils in combination with parallel transmit techniques produce time-dependent and spatially varying power loss densities in the tissue. Further, in ultra-high-field systems, localized field effects can be more pronounced due to a transition from the quasi stationary to the electromagnetic field regime. Consequently, local information on the RF field is required for reliable RF safety assessment as well as for monitoring of RF exposure during MR examinations. Numerical RF and thermal simulations for realistic exposure scenarios with anatomical body models are currently the only practical way to obtain the requisite local information on magnetic and electric field distributions as well as tissue temperature. In this article, safety regulations and the fundamental characteristics of RF field distributions in ultra-high-field systems are reviewed. Numerical methods for computation of RF fields as well as typical requirements for the analysis of realistic multi-channel RF exposure scenarios including anatomical body models are highlighted. In recent years, computation of the local tissue temperature has become of increasing interest, since a more accurate safety assessment is expected because temperature is directly related to tissue damage. Regarding thermal simulation, bio-heat transfer models and approaches for taking into account the physiological response of the human body to RF exposure are discussed. In addition, suitable methods are presented to validate calculated RF and thermal results with measurements. Finally, the concept of generalized simulation-based specific absorption rate (SAR) matrix models is discussed. These models can be incorporated into local SAR monitoring in multi-channel MR systems and allow the design of RF pulses under constraints for local SAR.


Assuntos
Absorção de Radiação , Radiação Eletromagnética , Temperatura Alta , Imageamento por Ressonância Magnética/normas , Modelos Anatômicos , Modelos Teóricos , Ondas de Rádio , Segurança/normas , Absorção de Radiação/fisiologia , Adulto , Feminino , Temperatura Alta/efeitos adversos , Humanos , Imageamento por Ressonância Magnética/efeitos adversos , Masculino , Ondas de Rádio/efeitos adversos
16.
Magn Reson Med ; 79(5): 2652-2664, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28994132

RESUMO

PURPOSE: Current methods for mitigation of transmit field B1+ inhomogeneities at ultrahigh field (UHF) MRI by multi-channel radiofrequency (RF) shimming rely on accurate B1+ mapping. This can be time consuming when many RF channels have to be mapped for in vivo body MRI, where the B1 maps should ideally be acquired within a single breath-hold. Therefore, a new B1+ mapping technique (B1TIAMO) is proposed. METHODS: The performance of this technique is validated against an established method (DREAM) in phantom measurements for a cylindrical head phantom with an 8-channel transmit/receive (Tx/Rx) array. Furthermore, measurements for a 32-channel Tx/Rx remote array are conducted in a large body phantom and the |B1+| map reliability is validated against simulations of the transmit RF field distribution. Finally, in vivo results of this new mapping technique for human abdomen are presented. RESULTS: For the head phantom (8-channel Tx/Rx coil), the single |B1+| comparison between B1 TIAMO, the direct DREAM measurements, and simulation data showed good agreement with 10-19% difference. For the large body phantom (32-channel Tx/Rx coil), B1TIAMO matched the RF field simulations well. CONCLUSION: The results demonstrate the potential to acquire 32 accurate single-channel B1+ maps for large field-of-view body imaging within only a single breath-hold of 16 s at 7T UHF MRI. Magn Reson Med 79:2652-2664, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Cabeça/diagnóstico por imagem , Humanos , Rim/diagnóstico por imagem , Masculino , Imagens de Fantasmas , Reprodutibilidade dos Testes , Imagem Corporal Total
17.
Geburtshilfe Frauenheilkd ; 78(12): 1232-1244, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30651661

RESUMO

Purpose On January 1st, 2018, the ÖGZ (Austrian Society of Cytology) revised its cytological nomenclature to make it more similar to the 2015 Bethesda system. Following these changes, the Austrian Society of Gynecology and Obstetrics felt it necessary to revise the approach currently used in Austria to diagnose and treat CIN and to review the procedures to be followed when the quality of cytological specimens is unsatisfactory. It was not possible to adopt the German S3 guideline "Prevention of Cervical Cancer" in its entirety, because the Munich III gynecological cytology nomenclature used in Germany is not used in Austria. This made it necessary to compile a separate scientific opinion for Austria. Methodology The OEGGG worked together with the ÖGZ (Austrian Society for Cytology), AGO Austria (Austrian Working Group for Gynecological Oncology), the AGK (Colposcopy Working Group), and physicians representing gynecologists in private practice. The different scientific associations nominated representatives, who attended the various meetings. After an in-depth analysis of the recent literature, three meetings and numerous votes by telephone, we were able to achieve a consensus about the contents of this guideline. Recommendations The guideline provides recommendations for the diagnosis and treatment of CIN which take account of the gynecological cytology nomenclature used in Austria.

18.
Materials (Basel) ; 10(9)2017 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-28902158

RESUMO

Metal matrix syntactic foams have been fabricated via counter-gravity infiltration of a packed bed of recycled expanded glass particles (EG) with A356 aluminum alloy. Particle shrinkage was studied and has been utilized to increase the particles' strength and tailor the mechanical properties of the expanded glass/metal syntactic foam (EG-MSF). The crushing strength of particles could be doubled by shrinking them for 20 min at 700 °C. Owing to the low density of EG (0.20-0.26 g/cm³), the resulting foam exhibits a low density (1.03-1.19 g/cm³) that increases slightly due to particle shrinkage. Chemical and physical analyses of EG particles and the resulting foams were conducted. Furthermore, metal syntactic foam samples were tested in uni-axial compression tests. The stress-strain curves obtained exhibit three distinct regions: elastic deformation followed by a stress plateau and densification commencing at 70-80% macroscopic strain. Particle shrinkage increased the mechanical strength of the foam samples and their average plateau stress increased from 15.5 MPa to 26.7 MPa.

19.
Materials (Basel) ; 10(8)2017 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-28786935

RESUMO

Over the past two decades, a large number of metallic foams have been developed. In recent years research on this multi-functional material class has further intensified. However, despite their unique properties only a limited number of large-scale applications have emerged. One important reason for this sluggish uptake is their high cost. Many cellular metals require expensive raw materials, complex manufacturing procedures, or a combination thereof. Some attempts have been made to decrease costs by introducing novel foams based on cheaper components and new manufacturing procedures. However, this has often yielded materials with unreliable properties that inhibit utilization of their full potential. The resulting balance between cost and performance of cellular metals is probed in this editorial, which attempts to consider cost not in absolute figures, but in relation to performance. To approach such a distinction, an alternative classification of cellular metals is suggested which centers on structural aspects and the effort of realizing them. The range thus covered extends from fully stochastic foams to cellular structures designed-to-purpose.

20.
MAGMA ; 30(6): 519-536, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28550649

RESUMO

OBJECTIVE: Functional parameters can be measured with the help of quantitative non-proton MRI where exact relaxometry parameters are needed. Investigation of [Formula: see text] is often biased by strong partial volume (PV) effects. Hence, in this work a PV correction algorithm approach was evaluated that uses iteratively adapted [Formula: see text]-values and high-resolution structural 1H data to determine transverse relaxation in non-proton MRI more accurately. MATERIALS AND METHODS: Simulations, a phantom study and in vivo 23Na, 17O and 35Cl MRI measurements of five healthy volunteers were performed to evaluate the algorithm. [Formula: see text] values of grey matter (GM), white matter (WM) and cerebrospinal fluid (CSF) were obtained. Data were acquired at B 0  = 7T with nominal spatial resolutions of (4-7 mm)3 using a density-adapted radial sequence. The resulting transverse relaxation times were used for quantification of 17O data. RESULTS: The conducted simulations and phantom study verified the correction performance of the algorithm. For in vivo measured [Formula: see text] values, the correction of PV effects leads to an increase in CSF and to a decrease in GM/WM (23Na MRI: long/short GM, WM [Formula: see text]: 36.4 ± 3.1/5.4 ± 0.2, 23.3 ± 2.6/3.5 ± 0.1 ms; 35Cl MRI: 8.9 ± 1.4/1.0 ± 0.4, 5.9 ± 0.3/0.4 ± 0.1 ms; 17O MRI: 2.5 ± 0.1, 2.8 ± 0.1 ms). Iteratively corrected in vivo [Formula: see text] values of the 17O study resulted in improved water content quantification. CONCLUSION: The proposed iterative algorithm for PV correction leads to more accurate [Formula: see text] values and, thus, can improve accuracy in quantitative non-proton MRI.


Assuntos
Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Cloro , Simulação por Computador , Feminino , Humanos , Hidrogênio , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Isótopos de Oxigênio , Imagens de Fantasmas , Prótons , Sódio , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...