Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(4)2024 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-38399127

RESUMO

This paper discusses the results of the micro-Raman analysis performed on paper-like graphene oxide (GO) samples consisting of many functionalised graphene layers and annealed at moderate temperatures (≤500 °C) under vacuum conditions (p ≃ 10-4 mbar). The analysis of the standalone samples revealed that the obtained material is characterised by a noticeable disorder level but still stays below the commonly accepted threshold of high or total disorder. GO formed in a simple way showed two spectral bands above 1650 cm-1 recorded very rarely or not at all and their origin has been discussed in detail. The results also confirmed the metastable character of multilayer GO after the annealing process at moderate temperatures as the C/O ratio was kept between 2 and 3 and the spectral features were stable within the annealing temperature range.

2.
Microsc Microanal ; 29(6): 2014-2025, 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-37944034

RESUMO

Correlative microscopy is a powerful technique that combines the advantages of multiple imaging modalities to achieve a comprehensive understanding of investigated samples. For example, fluorescence microscopy provides unique functional contrast by imaging only specifically labeled components, especially in biological samples. However, the achievable structural information on the sample in its full complexity is limited. Here, the intrinsic label-free carbon contrast of water window soft X-ray microscopy can complement fluorescence images in a correlative approach ultimately combining nanoscale structural resolution with functional contrast. However, soft X-ray microscopes are complex and elaborate, and are usually installed on large-scale synchrotron radiation sources due to the demanding photon flux requirements. Yet, with modern high-power lasers it has become possible to generate sufficient photon flux from laser-produced plasmas, thus enabling laboratory-based setups. Here, we present a compact table-top soft X-ray microscope with an integrated epifluorescence modality for "in situ" correlative imaging. Samples remain in place when switching between modalities, ensuring identical measurement conditions and avoiding sample alteration or destruction. We demonstrate our new method by multimodal images of several exemplary samples ranging from nanoparticles to various multicolor labeled cell types. A structural resolution of down to 50 nm was reached.

3.
Opt Express ; 30(26): 47867-47878, 2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36558705

RESUMO

The development of the broad-bandwidth photon sources emitting in the soft X-ray range has attracted great attention for a long time due to the possible applications in high-resolution spectroscopy, nano-metrology, and material sciences. A high photon flux accompanied by a broad, smooth spectrum is favored for the applications such as near-edge X-ray absorption fine structure (NEXAFS), extended X-ray absorption fine structure (EXAFS), or XUV/X-ray coherence tomography (XCT). So far, either large-scale facilities or technologically challenging systems providing only limited photon flux in a single shot dominate the suitable sources. Here, we present a soft, broad-band (1.5 nm - 10.7 nm) soft X-ray source. The source is based on the interaction of very intense laser pulses with a target formed by a cluster mixture. A photon yield of 2.4 × 1014 photons/pulse into 4π (full space) was achieved with a medium containing Xe clusters of moderate-size mixed with a substantial amount of extremely large ones. It is shown that such a cluster mixture enhances the photon yield in the soft X-ray range by roughly one order of magnitude. The size of the resulting source is not beneficial (≤500 µm but this deficit is compensated by a specific spectral structure of its emission fulfilling the specific needs of the spectroscopic (broad spectrum and high signal dynamics) and metrological applications (broad and smoothed spectrum enabling a sub-nanometer resolution limit for XCT).

4.
Stem Cells Int ; 2022: 8775591, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35378955

RESUMO

Hypoxia-mimetic agents are new potential tools in MSC priming instead of hypoxia incubators or chambers. Several pharmaceutical/chemical hypoxia-mimetic agents can be used to induce hypoxia in the tissues: deferoxamine (DFO), dimethyloxaloylglycine (DMOG), 2,4-dinitrophenol (DNP), cobalt chloride (CoCl2), and isoflurane (ISO). Hypoxia-mimetic agents can increase cell proliferation, preserve or enhance differentiation potential, increase migration potential, and induce neovascularization in a concentration- and stem cell source-dependent manner. Moreover, hypoxia-mimetic agents may increase HIF-1α, changing the metabolism and enhancing glycolysis like hypoxia. So, there is clear evidence that treatment with hypoxia-mimetic agents is beneficial in regenerative medicine, preserving stem cell capacities. These agents are not studied so wildly as hypoxia but, considering the low cost and ease of use, are believed to find application as pretreatment of many diseases such as ischemic heart disease and myocardial fibrosis and promote cardiac and cartilage regeneration. The knowledge of MSC priming is critical in evaluating safety procedures and use in clinics. In this review, similarities and differences between hypoxia and hypoxia-mimetic agents in terms of their therapeutic efficiency are considered in detail. The advantages, challenges, and future perspectives in MSC priming with hypoxia mimetic agents are also discussed.

5.
Opt Express ; 30(8): 13491-13509, 2022 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-35472960

RESUMO

Optical coherence tomography (OCT) with the use of soft x-rays (SXR) and extreme ultraviolet (EUV) has been recently demonstrated [Fuchs et al. Sci. Rep.6, 20658 (2016)10.1038/srep20658; Fuchs et al. Optica4, 903 (2017)10.1364/OPTICA.4.000903]. This new imaging technique, named XCT, makes it possible to obtain cross-sectional and tomographic images of objects with nanometer spatial resolution. The article presents a newly developed laboratory system for XCT using a compact laser plasma light source operating in the SXR and EUV spectral ranges. The source is based on a gas puff target containing Kr gas or a Kr/Xe gas mixture irradiated with nanosecond laser pulses from an Nd:YAG laser. The use of the gas puff target enables efficient emission of SXR and EUV radiation without generating target debris associated with laser ablation when using a solid target. The system is equipped with an ellipsoidal mirror to collect radiation from the source and focus on the imaged object. The XCT measurements are made by processing the spectrum of the radiation reflected from the object recorded with a transmission grating spectrometer equipped with an identical focusing mirror and a CCD camera. The paper presents the characterization and optimization of the new XCT system and its application to the measurements of layered nanostructures.

6.
Materials (Basel) ; 14(23)2021 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-34885490

RESUMO

A near 1-keV photons from the Xe/He plasma produced by the interaction of laser beam with a double stream gas puff target were employed for studies of L absorption edges of period 4 transitional metals with atomic number Z from 26 to 30. The dual-channel, compact NEXAFS system was employed for the acquisition of the absorption spectra. L1-3 absorption edges of the samples were identified in transmission mode using broadband emission from the Xe/He plasma to show the applicability of such source and measurement system to the NEXAFS studies of the transition metals, including magnetic materials.

7.
Int J Mol Sci ; 22(16)2021 Aug 06.
Artigo em Inglês | MEDLINE | ID: mdl-34445159

RESUMO

Polyetheretherketone (PEEK), due to its excellent mechanical and physico-chemical parameters, is an attractive substitute for hard tissues in orthopedic applications. However, PEEK is hydrophobic and lacks surface-active functional groups promoting cell adhesion. Therefore, the PEEK surface must be modified in order to improve its cytocompatibility. In this work, extreme ultraviolet (EUV) radiation and two low-temperature, EUV induced, oxygen and nitrogen plasmas were used for surface modification of polyetheretherketone. Polymer samples were irradiated with 100, 150, and 200 pulses at a 10 Hz repetition rate. The physical and chemical properties of EUV and plasma modified PEEK surfaces, such as changes of the surface topography, chemical composition, and wettability, were examined using atomic force microscopy (AFM), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and goniometry. The human osteoblast-like MG63 cells were used for the analysis of cell viability and cell adhesion on all modified PEEK surfaces. EUV radiation and two types of plasma treatment led to significant changes in surface topography of PEEK, increasing surface roughness and formation of conical structures. Additionally, significant changes in the chemical composition were found and were manifested with the appearance of new functional groups, incorporation of nitrogen atoms up to ~12.3 at.% (when modified in the presence of nitrogen), and doubling the oxygen content up to ~25.7 at.% (when modified in the presence of oxygen), compared to non-modified PEEK. All chemically and physically changed surfaces demonstrated cyto-compatible and non-cytotoxic properties, an enhancement of MG63 cell adhesion was also observed.


Assuntos
Benzofenonas/química , Materiais Biocompatíveis/química , Nitrogênio/química , Osteoblastos/citologia , Oxigênio/química , Gases em Plasma/química , Polímeros/química , Adesão Celular , Linhagem Celular , Humanos , Propriedades de Superfície , Raios Ultravioleta
8.
Opt Express ; 29(13): 20514-20525, 2021 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-34266139

RESUMO

Characterization of Xe emission in the spectral range between 1 and 1.5 keV is presented in the case when the laser-plasma is generated by nanosecond laser pulse irradiation of a double stream Xe/He gas-puff target. Gas target density was estimated using extreme ultraviolet (EUV) radiography. Emission spectral characteristics in the wavelength range from 0.8 to 5.2 nm were determined by using a flat field SXR spectrometer. Significant emission was recorded in two high-energy bands, the first one at wavelengths 0.8-1.6 nm (photon energy range 0.78-1.5 keV) and the second one at 1.6-2.5 nm (0.5-0.78 keV). Both plasma size and photon yield in each band were measured separately to individually assess radiation and source characteristics. Moreover, a proof-of-principle experiment for near-edge X-ray absorption fine structure spectroscopy of metallic sample near the L2,3 absorption edge was performed to show one of the applicability areas of such a compact source.

9.
Int J Mol Sci ; 22(14)2021 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-34298899

RESUMO

Understanding cancer cell adhesion could help to diminish tumor progression and metastasis. Adhesion mechanisms are currently the main therapeutic target of TNBC-resistant cells. This work shows the distribution and size of adhesive complexes determined with a common fluorescence microscopy technique and soft X-ray contact microscopy (SXCM). The results presented here demonstrate the potential of applying SXCM for imaging cell protrusions with high resolution when the cells are still alive in a physiological buffer. The possibility to observe the internal components of cells at a pristine and hydrated state with nanometer resolution distinguishes SXCM from the other more commonly used techniques for cell imaging. Thus, SXCM can be a promising technique for investigating the adhesion and organization of the actin cytoskeleton in cancer cells.


Assuntos
Adesão Celular/fisiologia , Neoplasias de Mama Triplo Negativas/patologia , Citoesqueleto de Actina/metabolismo , Linhagem Celular Tumoral , Feminino , Humanos , Microscopia de Fluorescência/métodos , Raios X
10.
Int J Mol Sci ; 21(24)2020 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-33353050

RESUMO

Recently, extreme ultraviolet (EUV) radiation has been increasingly used to modify polymers. Properties such as the extremely short absorption lengths in polymers and the very strong interaction of EUV photons with materials may play a key role in achieving new biomaterials. The purpose of the study was to examine the impact of EUV radiation on cell adhesion to the surface of modified polymers that are widely used in medicine: poly(tetrafluoroethylene) (PTFE), poly (vinylidene fluoride) (PVDF), and poly-L-(lactic acid) (PLLA). After EUV surface modification, which has been performed using a home-made laboratory system, changes in surface wettability, morphology, chemical composition and cell adhesion polymers were analyzed. For each of the three polymers, the EUV radiation differently effects the process of endothelial cell adhesion, dependent of the parameters applied in the modification process. In the case of PVDF and PTFE, higher cell number and cellular coverage were obtained after EUV radiation with oxygen. In the case of PLLA, better results were obtained for EUV modification with nitrogen. For all three polymers tested, significant improvements in endothelial cell adhesion after EUV modification have been demonstrated.


Assuntos
Adesão Celular , Células Endoteliais/fisiologia , Microvasos/fisiologia , Poliésteres/farmacologia , Politetrafluoretileno/farmacologia , Polivinil/farmacologia , Raios Ultravioleta , Células Cultivadas , Células Endoteliais/efeitos dos fármacos , Humanos , Microvasos/efeitos dos fármacos , Poliésteres/química , Poliésteres/efeitos da radiação , Politetrafluoretileno/química , Politetrafluoretileno/efeitos da radiação , Polivinil/química , Polivinil/efeitos da radiação , Propriedades de Superfície , Molhabilidade
11.
Materials (Basel) ; 13(19)2020 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-33050110

RESUMO

In this work, the effect of extreme ultraviolet (EUV) radiation and the combination of EUV radiation and low-temperature nitrogen plasma on the physico-chemical properties of polyetheretherketone (PEEK) surfaces were presented. The laser-plasma EUV source based on a double gas puff target was used in this experiment to irradiate PEEK surfaces with nanosecond pulses of EUV radiation and to produce low-temperature plasma through the photoionization of nitrogen with EUV photons. The changes in surface morphology on irradiated polymer samples were examined using atomic force microscopy (AFM) and scanning electron microscopy (SEM). Chemical changes of the PEEK surfaces were analysed using X-ray photoelectron spectroscopy (XPS). EUV radiation and nitrogen plasma treatment caused significant changes in the topography of modified PEEK's surfaces and an increase in their average roughness. Strong chemical decomposition, appearance of new functional groups as well as incorporation of nitrogen atoms up to ~17 at.% on the PEEK's surface were observed.

12.
Opt Express ; 28(15): 22478-22489, 2020 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-32752507

RESUMO

We present a 2-D mapping of a sample thickness with nanometer accuracy employing a compact arrangement of near-edge X-ray absorption fine structure (NEXAFS) technique. A NEXAFS spectrum coupled with a scanning system was used to generate a 2-D thickness map of the TiO2 sample (anatase form) deposited on the top of a SiN membrane. The thickness values were retrieved from the experimental data by applying different methods of data processing. In the paper, the detailed analysis of the data processing methods and the identified sources of the errors show that the proposed procedure based on averaging two imperfect estimates reduces the error caused by the uncontrolled bias of the measured signals. This procedure was termed as the average one. The estimates from the proposed average approach and the standard absorption-jump ratio in the absorption edge vicinity were compared with the direct results obtained by applying scanning electron microscopy (SEM). The experimental arrangement of the NEXAFS spectroscopy system, the data acquisition method, as well as the possible error sources, are presented and discussed in detail.

13.
Radiat Res ; 193(4): 372-382, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32097100

RESUMO

A standard Fricke dosimeter was used to measure the absorbed dose via the oxidation yields of Fe3+ ions in an aqueous environment induced by soft X rays within the "water window" spectral range. We also exploited the property of a neutral solution containing terephthalic acid as a tool for selective detection of OH radicals. Both dosimetric systems were irradiated using the experimental pulsed laser-plasma soft X-ray source as well as conventional 1.25-MeV gamma rays. Radiation chemical yields of Fe3+ ions and OH radicals were determined to be (5.13 ± 0.94) × 10-1 µmol·J-1 (4.95 ± 0.91 100eV-1) and (2.33 ± 0.35) × 10-2 µmol·J-1 (0.23 ± 0.03 100eV-1), respectively. Measurements were supported by Monte Carlo simulations to estimate the linear energy transfer of the water window radiation. The simulation results are in good agreement with expected linear energy transfer of ions inducing the same Fe3+ ion and OH radical radiation chemical yield.


Assuntos
Radical Hidroxila/química , Ferro/química , Radiometria , Raios X/efeitos adversos , Raios gama/efeitos adversos , Humanos , Radical Hidroxila/efeitos da radiação , Íons/química , Transferência Linear de Energia , Método de Monte Carlo , Oxirredução , Água/química
14.
Rev Sci Instrum ; 89(10): 103109, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399967

RESUMO

For investigating extreme ultraviolet (EUV) damage on optics, a table-top EUV focusing optical system was developed in the laboratory. Based on a modified Schwarzschild objective with a large numerical aperture and a laser-plasma light source, this optical system can generate a focusing spot with the maximum energy density of 2.27 J/cm2 at the focal plane of the objective at the wavelength of 13.5 nm. The structures and the characterized properties of this optical system are presented in this paper. For testing the performance of this setup, single-shot EUV damage tests were carried out on an optical substrate of CaF2 and a gold thin film. The damage thresholds and morphologies of these samples were given and discussed with former research studies.

15.
Materials (Basel) ; 11(8)2018 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-30060555

RESUMO

We present a proof of principle experiment on single-shot near edge soft X-ray fine structure (NEXAFS) spectroscopy with the use of a laboratory laser-plasma light source. The source is based on a plasma created as a result of the interaction of a nanosecond laser pulse with a double stream gas puff target. The laser-plasma source was optimized for efficient soft X-ray (SXR) emission from the krypton/helium target in the wavelength range from 2 nm to 5 nm. This emission was used to acquire simultaneously emission and absorption spectra of soft X-ray light from the source and from the investigated sample using a grazing incidence grating spectrometer. NEXAFS measurements in a transmission mode revealed the spectral features near the carbon K-α absorption edge of thin polyethylene terephthalate (PET) film and L-ascorbic acid in a single-shot. From these features, the composition of the PET sample was successfully obtained. The NEXAFS spectrum of the L-ascorbic acid obtained in a single-shot exposure was also compared to the spectrum obtained a multi-shot exposure and to numerical simulations showing good agreement. In the paper, the detailed information about the source, the spectroscopy system, the absorption spectra measurements and the results of the studies are presented and discussed.

16.
Sci Rep ; 8(1): 8494, 2018 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-29855555

RESUMO

We present optical coherence tomography (OCT) with 2 nm axial resolution using broadband soft X-ray radiation (SXR) from a compact laser plasma light source. The laser plasma was formed by the interaction of nanosecond laser pulses with a gaseous target in a double stream gas puff target approach. The source was optimized for efficient SXR emission from the krypton/helium gas puff target in the 2 to 5 nm spectral range, encompassing the entire "water-window" spectral range from 2.3 nm to 4.4 nm wavelength. The coherence parameters of the SXR radiation allowed for the OCT measurements of a bulk multilayer structure with 10 nm period and 40% bottom layer thickness to period ratio, with an axial resolution of about 2 nm and detect multilayer interfaces up to a depth of about 100 nm. The experimental data are in agreement with OCT simulations performed on ideal multilayer structure. In the paper, detailed information about the source, its optimization, the optical system, OCT measurements and the results are presented and discussed.

17.
Opt Express ; 26(7): 8260-8274, 2018 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-29715795

RESUMO

We present a compact laboratory system for near edge soft X-ray fine structure (NEXAFS) spectroscopy that was developed using a laser-plasma light source. The source is based on a double stream gas puff target. The plasma is formed by the interaction of a laser beam with the double stream gas puff target approach. The laser plasma source was optimized for efficient soft X-ray emission from a krypton/helium target in the range of 1.5 to 5 nm wavelength. This emission is used to acquire simultaneously the emission and absorption spectra of soft X-ray light from the source and from the investigated sample using a grazing incidence spectrometer. The measurements in the transmission mode reveal the features near the carbon K-α absorption edge of thin PET film. From those features, the composition of the sample was successfully obtained. The data are in agreement with synchrotron measurements. In the paper, the detailed information about the source, its optimization, the system, spectral measurements and the results are presented and discussed.

18.
J Microsc ; 265(2): 251-260, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27766644

RESUMO

We report on a very compact desk-top transmission extreme ultraviolet (EUV) microscope based on a laser-plasma source with a double stream gas-puff target, capable of acquiring magnified images of objects with a spatial (half-pitch) resolution of sub-50 nm. A multilayer ellipsoidal condenser is used to focus and spectrally narrow the radiation from the plasma, producing a quasi-monochromatic EUV radiation (λ = 13.8 nm) illuminating the object, whereas a Fresnel zone plate objective forms the image. Design details, development, characterization and optimization of the EUV source and the microscope are described and discussed. Test object and other samples were imaged to demonstrate superior resolution compared to visible light microscopy.

19.
Microsc Microanal ; 21(5): 1214-23, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26373378

RESUMO

Short illumination wavelength allows an extension of the diffraction limit toward nanometer scale; thus, improving spatial resolution in optical systems. Soft X-ray (SXR) radiation, from "water window" spectral range, λ=2.3-4.4 nm wavelength, which is particularly suitable for biological imaging due to natural optical contrast provides better spatial resolution than one obtained with visible light microscopes. The high contrast in the "water window" is obtained because of selective radiation absorption by carbon and water, which are constituents of the biological samples. The development of SXR microscopes permits the visualization of features on the nanometer scale, but often with a tradeoff, which can be seen between the exposure time and the size and complexity of the microscopes. Thus, herein, we present a desk-top system, which overcomes the already mentioned limitations and is capable of resolving 60 nm features with very short exposure time. Even though the system is in its initial stage of development, we present different applications of the system for biology and nanotechnology. Construction of the microscope with recently acquired images of various samples will be presented and discussed. Such a high resolution imaging system represents an interesting solution for biomedical, material science, and nanotechnology applications.


Assuntos
Biologia/métodos , Microscopia/instrumentação , Microscopia/métodos , Nanotecnologia/métodos , Animais , Carbono , Carcinoma/patologia , Neoplasias do Colo/patologia , Fibroblastos/citologia , Processamento de Imagem Assistida por Computador , Camundongos , Água , Raios X
20.
Opt Lett ; 39(3): 532-5, 2014 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24487858

RESUMO

A tomographic method for three-dimensional reconstruction of low density objects is presented and discussed. The experiment was performed in the extreme ultraviolet (EUV) spectral region using a desktop system for enhanced optical contrast and employing a compact laser-plasma EUV source, based on a double stream gas puff target. The system allows for volume reconstruction of transient gaseous objects, in this case gas jets, providing additional information for further characterization and optimization. Experimental details and reconstruction results are shown.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...