Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Rev Sci Instrum ; 93(2): 023502, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-35232152

RESUMO

We report a technique of proton deflectometry that uses a grid and an in situ reference x-ray grid image for precise measurements of magnetic fields in high-energy-density plasmas. A D3He fusion implosion provides a bright point source of both protons and x-rays, which is split into beamlets by a grid. The protons undergo deflections as they propagate through the plasma region of interest, whereas the x-rays travel along straight lines. The x-ray image, therefore, provides a zero-deflection reference image. The line-integrated magnetic fields are inferred from the shifts of beamlets between the deflected (proton) and reference (x-ray) images. We developed a system for analysis of these data, including automatic algorithms to find beamlet locations and to calculate their deflections from the reference image. The technique is verified in an experiment performed at OMEGA to measure a nonuniform magnetic field in vacuum and then applied to observe the interaction of an expanding plasma plume with the magnetic field.

2.
Rev Sci Instrum ; 92(4): 043524, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34243484

RESUMO

We present measurements of spatially and temporally resolved electron temperature in high-energy-density plasmas using gated x-ray pinhole imagers. A 2D image of bremsstrahlung x-ray self-emission from laser-driven plasma plumes is detected at the same time through two pinholes covered with different filter materials. By comparing the attenuated signal through each filter, a spatially resolved electron temperature as low as 0.1 keV can be estimated. Measurements of the plasma plume taken from different directions indicate that imaging through extended plasmas has a negligible effect on the temperature estimates. Methods for estimating the expected signal, selecting filters, and incorporating the response of the detector are discussed.

3.
Phys Rev Lett ; 125(14): 145001, 2020 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-33064539

RESUMO

In experiments performed with the OMEGA EP laser system, magnetic field generation in double ablation fronts was observed. Proton radiography measured the strength, spatial profile, and temporal dynamics of self-generated magnetic fields as the target material was varied between plastic, aluminum, copper, and gold. Two distinct regions of magnetic field are generated in mid-Z targets-one produced by gradients from electron thermal transport and the second from radiation-driven gradients. Extended magnetohydrodynamic simulations including radiation transport reproduced key aspects of the experiment, including field generation and double ablation front formation.

4.
Phys Rev E ; 101(3-1): 031201, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32289929

RESUMO

Relativistic electron temperatures were measured from kilojoule, subrelativistic laser-plasma interactions. Experiments show an order of magnitude higher temperatures than expected from a ponderomotive scaling, where temperatures of up to 2.2 MeV were generated using an intensity of 1×10^{18}W/cm^{2}. Two-dimensional particle-in-cell simulations suggest that electrons gain superponderomotive energies by stochastic acceleration as they sample a large area of rapidly changing laser phase. We demonstrate that such high temperatures are possible from subrelativistic intensities by using lasers with long pulse durations and large spatial scales.

5.
Phys Rev Lett ; 122(24): 245001, 2019 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-31322368

RESUMO

We present the first laboratory observations of time-resolved electron and ion velocity distributions in magnetized collisionless shock precursors. Thomson scattering of a probe laser beam was used to observe the interaction of a laser-driven, supersonic piston plasma expanding through an ambient plasma in an external magnetic field. From the Thomson-scattered spectra we measure time-resolved profiles of electron density, temperature, and ion flow speed, as well as spatially resolved magnetic fields from proton radiography. We observe direct evidence of the coupling between piston and ambient plasmas, including the acceleration of ambient ions driven by magnetic and pressure gradient electric fields, and deformation of the piston ion flow, key steps in the formation of magnetized collisionless shocks. Even before a shock has fully formed, we observe strong density compressions and electron heating associated with the pileup of piston ions. The results demonstrate that laboratory experiments can probe particle velocity distributions relevant to collisionless shocks, and can complement, and in some cases overcome, the limitations of similar measurements undertaken by spacecraft missions.

6.
Rev Sci Instrum ; 90(6): 063501, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31255022

RESUMO

The measurement of angularly resolved energy distributions of mega-electron-volt electrons is important for gaining a better understanding of the interaction of ultra-intense laser pulses with plasma, especially for fast-ignition laser-fusion research. It is also crucial when evaluating the production of suprathermal (several 10-keV) electrons through laser-plasma instabilities in conventional hot-spot-ignition and shock-ignition research. For these purposes, we developed a 10-in. manipulator-based multichannel electron spectrometer-the Osaka University electron spectrometer (OU-ESM)-that combines angular resolution with high-energy resolution. The OU-ESM consists of five small electron spectrometers set at every 5°, with an energy range from ∼40 keV to ∼40 MeV. A low-magnetic-field option provides a higher spectral resolution for an energy range of up to ∼5 MeV. We successfully obtained angularly resolved electron spectra for various experiments on the OMEGA and OMEGA EP laser systems.

7.
Phys Rev Lett ; 121(9): 095001, 2018 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-30230875

RESUMO

Recent experiments have demonstrated magnetic reconnection between colliding plasma plumes, where the reconnecting magnetic fields were self-generated in the plasma by the Biermann-battery effect. Using fully kinetic 3D simulations, we show the full evolution of the magnetic fields and plasma in these experiments, including self-consistent magnetic field generation about the expanding plume. The collision of the two plasmas drives the formation of a current sheet, where reconnection occurs in a strongly time- and space-dependent manner, demonstrating a new 3D reconnection mechanism. Specifically, we observe a fast, vertically localized Biermann-mediated reconnection, an inherently 3D process where the temperature profile in the current sheet coupled with the out-of-plane ablation density profile conspires to break inflowing field lines, reconnecting the field downstream. Fast reconnection is sustained by both the Biermann effect and the traceless electron pressure tensor, where the development of plasmoids appears to modulate the contribution of the latter. We present a simple and general formulation to consider the relevance of Biermann-mediated reconnection in general astrophysical scenarios.

8.
Rev Sci Instrum ; 89(8): 084703, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-30184699

RESUMO

A pulsed high magnetic field device based on the inductively coupled coil concept [D. H. Barnak et al., Rev. Sci. Instrum. 89, 033501 (2018)] is described. The device can be used for studying magnetized high-energy-density plasma and is capable of producing a pulsed magnetic field of 30 T inside a single-turn coil with an inner diameter of 6.5 mm and a length of 6.3 mm. The magnetic field is created by discharging a high-voltage capacitor through a multi-turn solenoid, which is inductively coupled to a small single-turn coil. The solenoid electric current pulse of tens of kA and a duration of several µs is inductively transformed to hundreds of kA in the single-turn coil, thus enabling a high magnetic field. Unlike directly driven single-turn systems that require a high-current and low-inductive power supply, the inductively coupled system operates using a relatively low-current power supply with very relaxed requirements for its inductance. This arrangement significantly simplifies the design of the power supply and also makes it possible to place the power supply at a significant distance from the coil. In addition, the device is designed to contain possible wire debris, which makes it attractive for debris-sensitive applications.

9.
Rev Sci Instrum ; 89(3): 033501, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29604743

RESUMO

Magnetized high energy density physics (HEDP) is a very active and relatively unexplored field that has applications in inertial confinement fusion, astrophysical plasma science, and basic plasma physics. A self-contained device, the Magneto-Inertial Fusion Electrical Discharge System, MIFEDS [G. Fiksel et al., Rev. Sci. Instrum. 86, 016105 (2015)], was developed at the Laboratory for Laser Energetics to conduct magnetized HEDP experiments on both the OMEGA [T. R. Boehly et al., Opt. Commun. 133, 495-506 (1997)] and OMEGA EP [J. H. Kelly et al., J. Phys. IV France 133, 75 (2006) and L. J. Waxer et al., Opt. Photonics News 16, 30 (2005)] laser systems. Extremely high magnetic fields are a necessity for magnetized HEDP, and the need for stronger magnetic fields continues to drive the redevelopment of the MIFEDS device. It is proposed in this paper that a magnetic coil that is inductively coupled rather than directly connecting to the MIFEDS device can increase the overall strength of the magnetic field for HEDP experiments by increasing the efficiency of energy transfer while decreasing the effective magnetized volume. A brief explanation of the energy delivery of the MIFEDS device illustrates the benefit of inductive coupling and is compared to that of direct connection for varying coil size and geometry. A prototype was then constructed to demonstrate a 7-fold increase in energy delivery using inductive coupling.

10.
Phys Rev Lett ; 119(2): 025001, 2017 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-28753335

RESUMO

We present the first laboratory generation of high-Mach-number magnetized collisionless shocks created through the interaction of an expanding laser-driven plasma with a magnetized ambient plasma. Time-resolved, two-dimensional imaging of plasma density and magnetic fields shows the formation and evolution of a supercritical shock propagating at magnetosonic Mach number M_{ms}≈12. Particle-in-cell simulations constrained by experimental data further detail the shock formation and separate dynamics of the multi-ion-species ambient plasma. The results show that the shocks form on time scales as fast as one gyroperiod, aided by the efficient coupling of energy, and the generation of a magnetic barrier between the piston and ambient ions. The development of this experimental platform complements present remote sensing and spacecraft observations, and opens the way for controlled laboratory investigations of high-Mach number collisionless shocks, including the mechanisms and efficiency of particle acceleration.

11.
Rev Sci Instrum ; 86(1): 016105, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25638132

RESUMO

An upgrade of the pulsed magnetic field generator magneto-inertial fusion electrical discharge system [O. Gotchev et al., Rev. Sci. Instrum. 80, 043504 (2009)] is described. The device is used to study magnetized high-energy-density plasma and is capable of producing a pulsed magnetic field of tens of tesla in a volume of a few cubic centimeters. The magnetic field is created by discharging a high-voltage capacitor through a small wire-wound coil. The coil current pulse has a duration of about 1 µs and a peak value of 40 kA. Compared to the original, the updated version has a larger energy storage and improved switching system. In addition, magnetic coils are fabricated using 3-D printing technology which allows for a greater variety of the magnetic field topology.

12.
Nat Commun ; 5: 5785, 2014 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-25503788

RESUMO

The advent of high-intensity lasers enables us to recreate and study the behaviour of matter under the extreme densities and pressures that exist in many astrophysical objects. It may also enable us to develop a power source based on laser-driven nuclear fusion. Achieving such conditions usually requires a target that is highly uniform and spherically symmetric. Here we show that it is possible to generate high densities in a so-called fast-ignition target that consists of a thin shell whose spherical symmetry is interrupted by the inclusion of a metal cone. Using picosecond-time-resolved X-ray radiography, we show that we can achieve areal densities in excess of 300 mg cm(-2) with a nanosecond-duration compression pulse--the highest areal density ever reported for a cone-in-shell target. Such densities are high enough to stop MeV electrons, which is necessary for igniting the fuel with a subsequent picosecond pulse focused into the resulting plasma.

13.
Rev Sci Instrum ; 85(11): 11E501, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25430343

RESUMO

A high-performance cryogenic DT inertial confinement fusion implosion experiment is an especially challenging backlighting configuration because of the high self-emission of the core at stagnation and the low opacity of the DT shell. High-energy petawatt lasers such as OMEGA EP promise significantly improved backlighting capabilities by generating high x-ray intensities and short emission times. A narrowband x-ray imager with an astigmatism-corrected bent quartz crystal for the Si Heα line at ∼1.86 keV was developed to record backlit images of cryogenic direct-drive implosions. A time-gated recording system minimized the self-emission of the imploding target. A fast target-insertion system capable of moving the backlighter target ∼7 cm in ∼100 ms was developed to avoid interference with the cryogenic shroud system. With backlighter laser energies of ∼1.25 kJ at a 10-ps pulse duration, the radiographic images show a high signal-to-background ratio of >100:1 and a spatial resolution of the order of 10 µm. The backlit images can be used to assess the symmetry of the implosions close to stagnation and the mix of ablator material into the dense shell.

14.
Phys Rev Lett ; 113(10): 105003, 2014 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-25238366

RESUMO

Observations of magnetic reconnection between colliding plumes of magnetized laser-produced plasma are presented. Two counterpropagating plasma flows are created by irradiating oppositely placed plastic (CH) targets with 1.8-kJ, 2-ns laser beams on the Omega EP Laser System. The interaction region between the plumes is prefilled with a low-density background plasma and magnetized by an externally applied magnetic field, imposed perpendicular to the plasma flow, and initialized with an X-type null point geometry with B=0 at the midplane and B=8 T at the targets. The counterflowing plumes sweep up and compress the background plasma and the magnetic field into a pair of magnetized ribbons, which collide, stagnate, and reconnect at the midplane, allowing the first detailed observations of a stretched current sheet in laser-driven reconnection experiments. The dynamics of current sheet formation are in good agreement with first-principles particle-in-cell simulations that model the experiments.

15.
Phys Rev Lett ; 111(22): 225002, 2013 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-24329452

RESUMO

Filamentation due to the growth of a Weibel-type instability was observed in the interaction of a pair of counterstreaming, ablatively driven plasma flows, in a supersonic, collisionless regime relevant to astrophysical collisionless shocks. The flows were created by irradiating a pair of opposing plastic (CH) foils with 1.8 kJ, 2-ns laser pulses on the OMEGA EP Laser System. Ultrafast laser-driven proton radiography was used to image the Weibel-generated electromagnetic fields. The experimental observations are in good agreement with the analytical theory of the Weibel instability and with particle-in-cell simulations.

16.
Rev Sci Instrum ; 84(10): 106103, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24182176

RESUMO

The Bragg angle, rocking curve, and reflection efficiency of a quartz crystal x-ray imager (Miller indices 234) were measured at photon energy of 15.6909 keV, corresponding to the K(α2) line of Zr, using the X15A beamline at the National Synchrotron Light Source at Brookhaven National Laboratory. One flat and three spherically curved samples were tested. The peak reflectivity of the best-performing crystal was determined to be (3.6 ± 0.7) × 10(-4) with a rocking-curve full width at half maximum of 0.09°. The Zr K(α2) emission was imaged from a hot Zr plasma generated by a 10-J multiterawatt laser.

17.
Phys Rev Lett ; 110(18): 185003, 2013 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-23683208

RESUMO

Magnetic fields generated by the nonlinear Rayleigh-Taylor growth of laser-seeded three-dimensional broadband perturbations were measured in laser-accelerated planar targets using ultrafast proton radiography. The experimental data show self-similar behavior in the growing cellular magnetic field structures. These observations are consistent with a bubble competition and merger model that predicts the time evolution of the number and size of the bubbles, linking the cellular magnetic field structures with the Rayleigh-Taylor bubble and spike growth.

18.
Phys Rev Lett ; 110(6): 065008, 2013 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-23432267

RESUMO

A new mechanism for intrinsic plasma flow has been experimentally identified in a toroidal plasma. For reversed field pinch plasmas with a few percent ß (ratio of plasma pressure to magnetic pressure), measurements show that parallel pressure fluctuations correlated with magnetic fluctuations create a kinetic stress that can affect momentum balance and the evolution of intrinsic plasma flow. This implies kinetic effects are important for flow generation and sustainment.

19.
Rev Sci Instrum ; 83(10): 10D302, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126829

RESUMO

An advanced neutral particle analyzer (ANPA) capable of simultaneously measuring hydrogen and deuterium ions of energies up to 45 keV has recently been developed for use on the Madison Symmetric Torus. The charge-to-mass separation allows for separate analysis of bulk deuterium ions and hydrogen ions injected with a 1 MW, 25 keV neutral beam. Orientation of the ANPA allows sampling of different regions of ion velocity space; a radial viewport favors collection of ions with high v(perpendicular)∕|v| while a recently installed tangential viewport favors ions with high v(||)∕|v|, such as those from the core-localized fast ion population created by the neutral beam. Signals are observed in the ANPA's highest energy channels during periodic magnetic reconnection events, which are drivers of anisotropic, non-Maxwellian ion energization in the reversed-field pinch. ANPA signal strength is dependent on the background neutral density, which also increases during magnetic reconnection events, so careful analysis must be performed to identify the true change in the ion distribution. A Monte Carlo neutral particle tracing code (NENE) is used to reconstruct neutral density profiles based on D(α) line emission, which is measured using a 16-chord filtered photodiode array.

20.
Rev Sci Instrum ; 83(10): 10D704, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23126878

RESUMO

A new E∥B neutral particle analyzer, which has recently been installed on Madison Symmetric Torus (MST) reversed-field pinch (RFP), has now been calibrated, allowing the measurement of the fast ion density and energy distribution. This diagnostic, dubbed the advanced neutral particle analyzer (ANPA), can simultaneously produce time resolved measurements of the efflux of both hydrogen and deuterium ions from the plasma over a 35 keV energy range with an energy resolution of 2-4 keV and a time resolution of 10 µs. These capabilities are needed to measure both majority ion heating that occurs during magnetic reconnection events in MST and the behavior of the fast ions from the 1 MW hydrogen neutral beam injector on MST. Calibration of the ANPA was performed using a custom ion source that resides in the flight tube between the MST and the ANPA. In this work, the ANPA will be described, the calibration procedure and results will be discussed, and initial measurements of the time evolution of 25 keV neutral beam injection-born fast ions will be presented.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...