Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Arq Neuropsiquiatr ; 82(1): 1-10, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38286434

RESUMO

BACKGROUND: Phantom limb pain (PLP) occurs after amputations and can persist in a chronic and debilitating way. Repetitive transcranial magnetic stimulation (rTMS) is a non-invasive neuromodulation method capable of influencing brain function and modulating cortical excitability. Its effectiveness in treating chronic pain is promising. OBJECTIVE: To evaluate the evidence on the efficacy and safety of using rTMS in the treatment of PLP, observing the stimulation parameters used, side effects, and benefits of the therapy. METHODS: This is a systematic review of scientific articles published in national and international literature using electronic platforms. RESULTS: Two hundred and fifty two articles were identified. Two hundred and forty six publications were removed because they were duplicated or met the exclusion criteria. After selection, six studies were reviewed, those being two randomized clinical trials and four case reports. All evaluated studies indicated some degree of benefit of rTMS to relieve painful symptoms, even temporarily. Pain perception was lower at the end of treatment when compared to the period prior to the sessions and remained during patient follow-up. There was no standardization of the stimulation parameters used. There were no reports of serious adverse events. The effects of long-term therapy have not been evaluated. CONCLUSION: There are some benefits, even if temporary, in the use of rTMS to relieve painful symptoms in PLP. High-frequency stimulation at M1 demonstrated a significant analgesic effect. Given the potential that has been demonstrated, but limited by the paucity of high-quality studies, further controlled studies are needed to establish and standardize the clinical use of the method.


ANTECEDENTES: A dor do membro fantasma (DMF) ocorre após amputações e pode persistir de forma crônica e debilitante. A estimulação magnética transcraniana repetitiva (EMTr) é um método de neuromodulação não invasivo capaz de influenciar a função cerebral e modular a excitabilidade cortical. Sua eficácia no tratamento da dor crônica é promissora. OBJETIVO: Avaliar as evidências sobre a eficácia e segurança do uso da EMTr no tratamento da DMF, observando os parâmetros de estimulação utilizados, efeitos colaterais e benefícios da terapia. MéTODOS: Trata-se de uma revisão sistemática de artigos científicos publicados na literatura nacional e internacional utilizando plataformas eletrônicas. RESULTADOS: Foram identificados 252 artigos. Duzentas e quarenta e seis publicações foram removidas por estarem duplicadas ou atenderem aos critérios de exclusão. Após a seleção, foram revisados seis estudos, sendo dois ensaios clínicos randomizados e quatro relatos de caso. Todos os estudos avaliados indicaram algum grau de benefício da EMTr no alívio dos sintomas dolorosos, mesmo que temporariamente. A percepção da dor foi menor ao final do tratamento quando comparada ao período anterior às sessões e permaneceu durante o acompanhamento do paciente. Não houve padronização dos parâmetros de estimulação utilizados. Não houve relatos de eventos adversos graves. Os efeitos da terapia a longo prazo não foram avaliados. CONCLUSãO: Existem alguns benefícios, mesmo que temporários, no uso da EMTr para alívio dos sintomas dolorosos na DMF. A estimulação de alta frequência em M1 demonstrou um efeito analgésico significativo. Dado o potencial demonstrado, mas limitado pela escassez de estudos de alta qualidade, são necessários mais estudos controlados para estabelecer e padronizar o uso clínico do método.


Assuntos
Dor Crônica , Membro Fantasma , Humanos , Estimulação Magnética Transcraniana/efeitos adversos , Estimulação Magnética Transcraniana/métodos , Membro Fantasma/terapia , Membro Fantasma/etiologia , Dor Crônica/terapia
2.
Arq Neuropsiquiatr ; 69(3): 460-5, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21755122

RESUMO

OBJECTIVE: To identify P50 suppression in patients with epilepsy, to investigate the effect of seizure control on P50 suppression, and to compare epilepsy patients with individuals with schizophrenia and healthy volunteers. METHOD: P50 evoked potential parameters and P50 suppression were studied crossectionally in patients with uncontrolled or controlled epilepsy, in individuals with schizophrenia and in healthy volunteers. RESULTS: Individuals with schizophrenia had significantly smaller conditioning stimulus (S1) amplitude, and patients with epilepsy had larger test stimulus (S2) amplitude. Mean S2/S1 ratio was 0.71 ± 0.33 for patients with uncontrolled epilepsy; 0.68 ± 0.36 for patients with controlled epilepsy; 0.96 ± 0.47 for individuals with schizophrenia, and 0.42 ± 0.24 for healthy volunteers. CONCLUSION: The sensory filter of patients with epilepsy is altered, and this alteration is not associated with seizure control. Also, it works differently from the sensory filter of individuals with schizophrenia.


Assuntos
Epilepsia/fisiopatologia , Potenciais Evocados Auditivos/fisiologia , Esquizofrenia/fisiopatologia , Estimulação Acústica , Adolescente , Adulto , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tempo de Reação , Adulto Jovem
3.
Arq. neuropsiquiatr ; 69(3): 460-465, June 2011. ilus, tab
Artigo em Inglês | LILACS | ID: lil-592503

RESUMO

OBJECTIVE: To identify P50 suppression in patients with epilepsy, to investigate the effect of seizure control on P50 suppression, and to compare epilepsy patients with individuals with schizophrenia and healthy volunteers. METHOD: P50 evoked potential parameters and P50 suppression were studied crossectionally in patients with uncontrolled or controlled epilepsy, in individuals with schizophrenia and in healthy volunteers. RESULTS: Individuals with schizophrenia had significantly smaller conditioning stimulus (S1) amplitude, and patients with epilepsy had larger test stimulus (S2) amplitude. Mean S2/S1 ratio was 0.71±0.33 for patients with uncontrolled epilepsy; 0.68±0.36 for patients with controlled epilepsy; 0.96±0.47 for individuals with schizophrenia, and 0.42±0.24 for healthy volunteers. CONCLUSION: The sensory filter of patients with epilepsy is altered, and this alteration is not associated with seizure control. Also, it works differently from the sensory filter of individuals with schizophrenia.


OBJETIVO: Identificar se existe déficit de supressão do P50 em pacientes com epilepsia, verificar a influência do controle das crises nesse déficit, comparando com pacientes com esquizofrenia e com voluntários saudáveis. MÉTODO: Os parâmetros do potencial evocado P50 e sua supressão foram estudados, com um corte transversal, em pacientes com epilepsia controlada ou não, esquizofrenia e em voluntários saudáveis. RESULTADOS: Indivíduos com esquizofrenia apresentam uma amplitude de S1 significativamente menor que os demais, sendo que os pacientes com epilepsia apresentavam uma resposta S2 de maior amplitude. A média da razão S2/S1 foi de 0,71±0,33 nos pacientes com epilepsia não controlada; 0,68±0,36 naqueles com epilepsia controlada; 0,96±0,47 nos com esquizofrenia e 0,42±0,24 nos controles normais. CONCLUSÃO: O filtro sensitivo de pacientes com epilepsia é alterado, e essa alteração não está associada com o controle das crises. Além disso, ele funciona de forma diferente do filtro sensitivo dos indivíduos com esquizofrenia.


Assuntos
Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Epilepsia/fisiopatologia , Potenciais Evocados Auditivos/fisiologia , Esquizofrenia/fisiopatologia , Estimulação Acústica , Estudos de Casos e Controles , Estudos Transversais , Tempo de Reação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...