Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Med ; 13(7)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38610666

RESUMO

(1) Background: Total knee arthroplasty (TKA) performed on working-age patients significantly affects the participation of such patients in social life. A retrospective study was conducted to determine the return to work (RTW) rate after TKA. The goal of this study was to provide reference data for the Polish population and identify the factors impacting patients' decisions to return to or resign from work, relative to their functional performance. (2) Methods: This retrospective study involved 48 patients. An interview related to RTW was carried out to identify the factors impacting a patient's decision to return to or resign from work. Functional performance was assessed using the Knee Outcome Survey-Activities of Daily Living (KOS-ADL) scale. (3) Results: Before TKA, 15 individuals (31.25%) qualified for the study did not work and were receiving welfare benefits. After the surgery, 23 individuals (47.9% of those working prior to TKA) did not return to work. The number of those who did not work after TKA increased to 38 (79.17%), which was a significant change. The mean level of functional performance after TKA assessed using KOS-ADL was 75.89. (4) Conclusions: The findings show that the rate of RTW after TKA in Poland is significantly lower than that in other countries. The reasons for this situation, as shown in the study, may be related to the lack of an occupational rehabilitation system, resulting in a paucity of information about the possibility to return to work and about opportunities for retraining.

2.
Polymers (Basel) ; 14(11)2022 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35683908

RESUMO

Currently, medicine uses typical industrial structure techniques, including reverse engineering, data processing, 3D-CAD modeling, 3D printing, and coordinate measurement techniques. Taking this into account, one can notice the applications of procedures used in the aviation or automotive industries based on the structure of Industry 4.0 in the planning of operations and the production of medical models with high geometric accuracy. The procedure presented in the publication shortens the processing time of tomographic data and increases the reconstruction accuracy within the hip and knee joints. The procedure allows for the partial removal of metallic artifacts from the diagnostic image. Additionally, numerical models of anatomical structures, implants, and bone cement were developed in more detail by averaging the values of local segmentation thresholds. Before the model manufacturing process, additional tests of the PLA material were conducted in terms of its strength and thermal properties. Their goal was to select the appropriate type of PLA material for manufacturing models of anatomical structures. The numerical models were divided into parts before being manufactured using the Fused Filament Fabrication technique. The use of the modifier made it possible to change the density, type of filling, number of counters, and the type of supporting structure. These treatments allowed us to reduce costs and production time and increase the accuracy of the printout. The accuracy of the manufactured model geometry was verified using the MCA-II measuring arm with the MMDx100 laser head and surface roughness using a 3D Talyscan 150 profilometer. Using the procedure, a decrease in geometric deviations and amplitude parameters of the surface roughness were noticed. The models based on the presented approach allowed for detailed and meticulous treatment planning.

3.
Polymers (Basel) ; 14(8)2022 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-35458276

RESUMO

Tissue engineering is an interdisciplinary field of science that has developed very intensively in recent years. The first part of this review describes materials with medical and dental applications from the following groups: metals, polymers, ceramics, and composites. Both positive and negative sides of their application are presented from the point of view of medical application and mechanical properties. A variety of techniques for the manufacture of biomedical components are presented in this review. The main focus of this work is on additive manufacturing and 3D printing, as these modern techniques have been evaluated to be the best methods for the manufacture of medical and dental devices. The second part presents devices for skull bone reconstruction. The materials from which they are made and the possibilities offered by 3D printing in this field are also described. The last part concerns dental transitional implants (scaffolds) for guided bone regeneration, focusing on polylactide-hydroxyapatite nanocomposite due to its unique properties. This section summarises the current knowledge of scaffolds, focusing on the material, mechanical and biological requirements, the effects of these devices on the human body, and their great potential for applications.

4.
Epilepsy Res ; 98(2-3): 148-56, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21944895

RESUMO

The aim of this study was to characterize the anticonvulsant effects of pregabalin in combination with four second-generation antiepileptic drugs (i.e., gabapentin, levetiracetam, tiagabine, and vigabatrin) in the mouse maximal electroshock (MES)-induced seizure model by using the type II isobolographic analysis. Tonic hind limb extension (seizure activity) was evoked in adult male albino Swiss mice by a current (sine-wave, 25 mA, 500 V, 50 Hz, 0.2 s stimulus duration) delivered via auricular electrodes. The combination of pregabalin with gabapentin at the fixed-ratio of 1:1 was supra-additive (synergistic) in terms of seizure suppression while the combinations at the fixed-ratios of 2:1 and 4:1 were additive in the mouse MES model. Similarly, the combination of pregabalin with tiagabine at the fixed-ratio of 25:1 was supra-additive, whereas the combinations at the fixed-ratios of 100:1 and 50:1 were additive in the mouse MES model. Pregabalin with levetiracetam and vigabatrin at the fixed-ratios of 1:1, 2:1 and 4:1 were additive in this seizure model. The combinations of pregabalin with gabapentin (1:1) and pregabalin with tiagabine (25:1) appear to be favorable combinations exerting supra-additive interaction in suppressing MES-induced seizures. Pregabalin in combination with levetiracetam and vigabatrin appears to be neutral producing only additivity in the mouse MES model.


Assuntos
Anticonvulsivantes/uso terapêutico , Eletrochoque/efeitos adversos , Convulsões/tratamento farmacológico , Convulsões/etiologia , Ácido gama-Aminobutírico/análogos & derivados , Aminas , Animais , Aprendizagem da Esquiva/efeitos dos fármacos , Intervalos de Confiança , Ácidos Cicloexanocarboxílicos , Modelos Animais de Doenças , Relação Dose-Resposta a Droga , Sinergismo Farmacológico , Gabapentina , Força da Mão/fisiologia , Levetiracetam , Masculino , Camundongos , Atividade Motora/efeitos dos fármacos , Piracetam/análogos & derivados , Pregabalina , Convulsões/fisiopatologia , Vigabatrina , Ácido gama-Aminobutírico/uso terapêutico
5.
Epilepsy Res ; 91(2-3): 166-75, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20692123

RESUMO

The aim of this study was to characterize the anticonvulsant effects of pregabalin (PGB-a third-generation antiepileptic drug) in combination with three second-generation antiepileptic drugs (i.e., lamotrigine [LTG], oxcarbazepine [OXC] and topiramate [TPM]) in the mouse maximal electroshock (MES)-induced seizure model by using the type I isobolographic analysis for non-parallel dose-response relationship curves (DRRCs). Tonic hind limb extension (seizure activity) was evoked in adult male albino Swiss mice by a current (sine-wave, 25mA, 500V, 50Hz, 0.2s stimulus duration) delivered via auricular electrodes. Potential adverse-effect profiles of interactions of PGB with LTG, OXC and TPM at the fixed-ratio of 1:1 in the MES test with respect to motor performance, long-term memory and skeletal muscular strength were measured. In the mouse MES model, PGB administered singly had its DRRC non-parallel to that for LTG, OXC and TPM. With type I isobolography for non-parallel DRRCs, the combinations of PGB with LTG, OXC and TPM at the fixed-ratio of 1:1 exerted additive interaction. In all combinations, neither motor coordination, long-term memory nor muscular strength were affected. In conclusion, the additive interactions between PGB and LTG, OXC and TPM are worthy of consideration while extrapolating the results from this study to clinical settings.


Assuntos
Carbamazepina/análogos & derivados , Modelos Animais de Doenças , Frutose/análogos & derivados , Convulsões/tratamento farmacológico , Triazinas/administração & dosagem , Ácido gama-Aminobutírico/análogos & derivados , Animais , Carbamazepina/administração & dosagem , Relação Dose-Resposta a Droga , Interações Medicamentosas/fisiologia , Sinergismo Farmacológico , Quimioterapia Combinada , Eletrochoque/efeitos adversos , Eletrochoque/métodos , Frutose/administração & dosagem , Lamotrigina , Masculino , Camundongos , Oxcarbazepina , Pregabalina , Desempenho Psicomotor/efeitos dos fármacos , Desempenho Psicomotor/fisiologia , Convulsões/etiologia , Convulsões/fisiopatologia , Topiramato , Ácido gama-Aminobutírico/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA