Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
2.
Phys Rev Lett ; 130(5): 051802, 2023 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-36800478

RESUMO

The inclusive electron neutrino charged-current cross section is measured in the NOvA near detector using 8.02×10^{20} protons-on-target in the NuMI beam. The sample of GeV electron neutrino interactions is the largest analyzed to date and is limited by ≃17% systematic rather than the ≃7.4% statistical uncertainties. The double-differential cross section in final-state electron energy and angle is presented for the first time, together with the single-differential dependence on Q^{2} (squared four-momentum transfer) and energy, in the range 1 GeV≤E_{ν}<6 GeV. Detailed comparisons are made to the predictions of the GENIE, GiBUU, NEUT, and NuWro neutrino event generators. The data do not strongly favor a model over the others consistently across all three cross sections measured, though some models have especially good or poor agreement in the single differential cross section vs Q^{2}.

4.
Phys Rev Lett ; 127(20): 201801, 2021 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-34860065

RESUMO

This Letter reports results from the first long-baseline search for sterile antineutrinos mixing in an accelerator-based antineutrino-dominated beam. The rate of neutral-current interactions in the two NOvA detectors, at distances of 1 and 810 km from the beam source, is analyzed using an exposure of 12.51×10^{20} protons-on-target from the NuMI beam at Fermilab running in antineutrino mode. A total of 121 of neutral-current candidates are observed at the far detector, compared to a prediction of 122±11(stat.)±15(syst.) assuming mixing only between three active flavors. No evidence for ν[over ¯]_{µ}→ν[over ¯]_{s} oscillation is observed. Interpreting this result within a 3+1 model, constraints are placed on the mixing angles θ_{24}<25° and θ_{34}<32° at the 90% C.L. for 0.05 eV^{2}≤Δm_{41}^{2}≤0.5 eV^{2}, the range of mass splittings that produces no significant oscillations at the near detector. These are the first 3+1 confidence limits set using long-baseline accelerator antineutrinos.

5.
Eur J Cardiothorac Surg ; 60(2): 295-296, 2021 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-34051079
6.
Ann Thorac Surg ; 111(1): 314-326, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33036738

RESUMO

Comprehensive information on the characteristics of surgical heart valves (SHVs) is essential for optimal valve selection. Such information is also important in assessing SHV function after valve replacement. Despite the existing regulatory framework for SHV sizing and labelling, this information is challenging to obtain in a uniform manner for various SHVs. To ensure that clinicians are adequately informed, the European Association for Cardio-Thoracic Surgery (EACTS), The Society of Thoracic Surgeons (STS) and American Association for Thoracic Surgery (AATS) set up a Task Force comprised of cardiac surgeons, cardiologists, engineers, regulatory bodies, representatives of the International Organization for Standardization and major valve manufacturers. Previously, the EACTS-STS-AATS Valve Labelling Task Force identified the most important problems around SHV sizing and labelling. This Expert Consensus Document formulates recommendations for providing SHV physical dimensions, intended implant position and hemodynamic performance in a transparent, uniform manner. Furthermore, the Task Force advocates for the introduction and use of a standardized chart to assess the probability of prosthesis-patient mismatch and calls valve manufacturers to provide essential information required for SHV choice on standardized Valve Charts, uniformly for all SHV models.


Assuntos
Implante de Prótese de Valva Cardíaca/normas , Próteses Valvulares Cardíacas/normas , Desenho de Prótese/normas , Árvores de Decisões , Humanos
7.
J Thorac Cardiovasc Surg ; 161(2): 545-558, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33070936

RESUMO

Comprehensive information on the characteristics of surgical heart valves (SHVs) is essential for optimal valve selection. Such information is also important in assessing SHV function after valve replacement. Despite the existing regulatory framework for SHV sizing and labelling, this information is challenging to obtain in a uniform manner for various SHVs. To ensure that clinicians are adequately informed, the European Association for Cardio-Thoracic Surgery (EACTS), The Society of Thoracic Surgeons (STS) and American Association for Thoracic Surgery (AATS) set up a Task Force comprised of cardiac surgeons, cardiologists, engineers, regulatory bodies, representatives of the International Organization for Standardization and major valve manufacturers. Previously, the EACTS-STS-AATS Valve Labelling Task Force identified the most important problems around SHV sizing and labelling. This Expert Consensus Document formulates recommendations for providing SHV physical dimensions, intended implant position and hemodynamic performance in a transparent, uniform manner. Furthermore, the Task Force advocates for the introduction and use of a standardized chart to assess the probability of prosthesis-patient mismatch and calls valve manufacturers to provide essential information required for SHV choice on standardized Valve Charts, uniformly for all SHV models.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/normas , Próteses Valvulares Cardíacas/normas , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Bioprótese/normas , Doenças das Valvas Cardíacas/patologia , Valvas Cardíacas/patologia , Valvas Cardíacas/cirurgia , Hemodinâmica/fisiologia , Humanos
8.
Eur J Cardiothorac Surg ; 59(1): 54-64, 2021 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-33021620

RESUMO

Comprehensive information on the characteristics of surgical heart valves (SHVs) is essential for optimal valve selection. Such information is also important in assessing SHV function after valve replacement. Despite the existing regulatory framework for SHV sizing and labelling, this information is challenging to obtain in a uniform manner for various SHVs. To ensure that clinicians are adequately informed, the European Association for Cardio-Thoracic Surgery (EACTS), The Society of Thoracic Surgeons (STS) and American Association for Thoracic Surgery (AATS) set up a Task Force comprised of cardiac surgeons, cardiologists, engineers, regulatory bodies, representatives of the International Organization for Standardization and major valve manufacturers. Previously, the EACTS-STS-AATS Valve Labelling Task Force identified the most important problems around SHV sizing and labelling. This Expert Consensus Document formulates recommendations for providing SHV physical dimensions, intended implant position and haemodynamic performance in a transparent, uniform manner. Furthermore, the Task Force advocates for the introduction and use of a standardized chart to assess the probability of prosthesis-patient mismatch and calls valve manufacturers to provide essential information required for SHV choice on standardized Valve Charts, uniformly for all SHV models.


Assuntos
Próteses Valvulares Cardíacas , Cirurgiões , Cirurgia Torácica , Consenso , Valvas Cardíacas , Humanos , Próteses e Implantes , Estados Unidos
9.
PLoS One ; 15(9): e0239363, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32970710

RESUMO

BACKGROUND: Healthcare workers around the world are experiencing skin injury due to the extended use of personal protective equipment (PPE) during the COVID-19 pandemic. These injuries are the result of high shear stresses acting on the skin, caused by friction with the PPE. This study aims to provide a practical lubricating solution for frontline medical staff working a 4+ hours shift wearing PPE. METHODS: A literature review into skin friction and skin lubrication was conducted to identify products and substances that can reduce friction. We evaluated the lubricating performance of commercially available products in vivo using a custom-built tribometer. FINDINGS: Most lubricants provide a strong initial friction reduction, but only few products provide lubrication that lasts for four hours. The response of skin to friction is a complex interplay between the lubricating properties and durability of the film deposited on the surface and the response of skin to the lubricating substance, which include epidermal absorption, occlusion, and water retention. INTERPRETATION: Talcum powder, a petrolatum-lanolin mixture, and a coconut oil-cocoa butter-beeswax mixture showed excellent long-lasting low friction. Moisturising the skin results in excessive friction, and the use of products that are aimed at 'moisturising without leaving a non-greasy feel' should be prevented. Most investigated dressings also demonstrate excellent performance.


Assuntos
Infecções por Coronavirus/complicações , Lubrificantes/uso terapêutico , Equipamento de Proteção Individual/efeitos adversos , Pneumonia Viral/complicações , Pele/lesões , Adulto , Betacoronavirus , Fenômenos Biomecânicos , COVID-19 , Fricção , Humanos , Masculino , Corpo Clínico , Pandemias , SARS-CoV-2
10.
Phys Rev Lett ; 125(26): 262301, 2020 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-33449792

RESUMO

Flow coefficients v_{n} of the orders n=1-6 are measured with the High-Acceptance DiElectron Spectrometer (HADES) at GSI for protons, deuterons, and tritons as a function of centrality, transverse momentum, and rapidity in Au+Au collisions at sqrt[s_{NN}]=2.4 GeV. Combining the information from the flow coefficients of all orders allows us to construct for the first time, at collision energies of a few GeV, a multidifferential picture of the angular emission pattern of these particles. It reflects the complicated interplay between the effect of the central fireball pressure on the emission of particles and their subsequent interaction with spectator matter. The high precision information on higher order flow coefficients is a major step forward in constraining the equation of state of dense baryonic matter.

11.
Ann Thorac Surg ; 108(1): 292-303, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31084919

RESUMO

Intraoperative surgical prosthetic heart valve (SHV) choice is a key determinant of successful surgery and positive postoperative outcomes. Currently, many controversies exist around the sizing and labelling of SHVs rendering the comparison of different valves difficult. To explore solutions, an expert Valve Labelling Task Force was jointly initiated by the European Association for Cardio-Thoracic Surgery (EACTS), The Society of Thoracic Surgeons (STS) and the American Association for Thoracic Surgery (AATS). The EACTS-STS-AATS Valve Labelling Task Force, comprising cardiac surgeons, cardiologists, engineers, regulators and representatives from the International Organization for Standardization (ISO) and major valve manufacturers, held its first in-person meeting in February 2018 in Paris, France. This article was derived from the meeting's discussions. The Task Force identified the following areas for improvement and clarification: reporting of physical dimensions and characteristics of SHVs determining and labelling of SHV size, in vivo and in vitro testing and reporting of SHV hemodynamic performance and thrombogenicity. Furthermore, a thorough understanding of the regulatory background and the role of the applicable ISO standards, together with close cooperation between all stakeholders (including regulatory and standard-setting bodies), is necessary to improve the current situation. Cardiac surgeons should be provided with appropriate information to allow for optimal SHV choice. This first article from the EACTS-STS-AATS Valve Labelling Task Force summarizes the background of SHV sizing and labelling and identifies the most important elements where further standardization is necessary.


Assuntos
Regulamentação Governamental , Próteses Valvulares Cardíacas , Rotulagem de Produtos/legislação & jurisprudência , Comitês Consultivos , União Europeia , Próteses Valvulares Cardíacas/normas , Humanos , Desenho de Prótese , Sociedades Médicas , Cirurgia Torácica , Estados Unidos
12.
J Thorac Cardiovasc Surg ; 158(4): 1041-1054, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31084981

RESUMO

Intraoperative surgical prosthetic heart valve (SHV) choice is a key determinant of successful surgery and positive postoperative outcomes. Currently, many controversies exist around the sizing and labeling of SHVs rendering the comparison of different valves difficult. To explore solutions, an expert Valve Labelling Task Force was jointly initiated by the European Association for Cardio-Thoracic Surgery (EACTS), The Society of Thoracic Surgeons (STS) and the American Association for Thoracic Surgery (AATS). The EACTS-STS-AATS Valve Labelling Task Force, comprising cardiac surgeons, cardiologists, engineers, regulators and representatives from the International Organization for Standardization (ISO), and major valve manufacturers, held its first in-person meeting in February 2018 in Paris, France. This article was derived from the meeting's discussions. The Task Force identified the following areas for improvement and clarification: reporting of physical dimensions and characteristics of SHVs determining and labeling of SHV size, in vivo and in vitro testing, and reporting of SHV hemodynamic performance and thrombogenicity. Furthermore, a thorough understanding of the regulatory background and the role of the applicable ISO standards, together with close cooperation between all stakeholders (including regulatory and standard- setting bodies), is necessary to improve the current situation. Cardiac surgeons should be provided with appropriate information to allow for optimal SHV choice. This first article from the EACTS-STS-AATS Valve Labelling Task Force summarizes the background of SHV sizing and labeling and identifies the most important elements where further standardization is necessary.


Assuntos
Bioprótese/normas , Cardiologia/normas , Qualidade de Produtos para o Consumidor/normas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/normas , Próteses Valvulares Cardíacas/normas , Rotulagem de Produtos/normas , Desenho de Prótese/normas , Tomada de Decisão Clínica , Consenso , Análise de Falha de Equipamento/normas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Seleção de Pacientes , Falha de Prótese , Sociedades Médicas
13.
Eur J Cardiothorac Surg ; 55(6): 1025-1036, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31075173

RESUMO

Intraoperative surgical prosthetic heart valve (SHV) choice is a key determinant of successful surgery and positive postoperative outcomes. Currently, many controversies exist around the sizing and labelling of SHVs rendering the comparison of different valves difficult. To explore solutions, an expert Valve Labelling Task Force was jointly initiated by the European Association for Cardio-Thoracic Surgery (EACTS), The Society of Thoracic Surgeons (STS) and the American Association for Thoracic Surgery (AATS). The EACTS-STS-AATS Valve Labelling Task Force, comprising cardiac surgeons, cardiologists, engineers, regulators and representatives from the International Organization for Standardization (ISO) and major valve manufacturers, held its first in-person meeting in February 2018 in Paris, France. This article was derived from the meeting's discussions. The Task Force identified the following areas for improvement and clarification: reporting of physical dimensions and characteristics of SHVs determining and labelling of SHV size, in vivo and in vitro testing and reporting of SHV haemodynamic performance and thrombogenicity. Furthermore, a thorough understanding of the regulatory background and the role of the applicable ISO standards, together with close cooperation between all stakeholders (including regulatory and standard-setting bodies), is necessary to improve the current situation. Cardiac surgeons should be provided with appropriate information to allow for optimal SHV choice. This first article from the EACTS-STS-AATS Valve Labelling Task Force summarizes the background of SHV sizing and labelling and identifies the most important elements where further standardization is necessary.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Rotulagem de Produtos/métodos , Sociedades Médicas , Cirurgia Torácica , Europa (Continente) , Humanos , Desenho de Prótese , Estados Unidos
15.
Int J Cosmet Sci ; 38(6): 558-566, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26940853

RESUMO

OBJECTIVE: Evaluation of sensory attributes of cosmetic products is traditionally based on sensory panels. However, in some cases, a suitable candidate method that can reduce time and costs is the use of instrumental analysis that can detect relatively very small changes of entry ingredients. Such approach has been already applied for emollients, salt content, stabilizers, etc. The aim of this contribution is to apply the relations between sensory analysis and rheology to a series of body lotions differing in the contents of emulsifiers and viscosity regulators. METHODS: Sensory and rheological analyses are related. Rheological analysis can represent a good alternative to basic orientation in chosen customer's feelings. A rotational rheometer is the only instrumental device required for the measurements. RESULTS: An empirical rheological model was proposed by means of which the selected sensory attributes were evaluated using the numerical values of adjustable model parameters. This approach exhibited a very good agreement with the results obtained by the sensory panel. CONCLUSION: It was shown that a description of chosen sensory attributes can be responsibly carried out by rheological measurements, that is through the attained numerical values of the parameters appearing in a proposed empirical model characterizing shear viscosity of body lotions.


Assuntos
Emolientes , Reologia , Humanos
16.
J Neurosci Methods ; 253: 218-32, 2015 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-26162613

RESUMO

BACKGROUND: In some fields of fMRI data analysis, using correct methods for dealing with noise is crucial for achieving meaningful results. This paper provides a quantitative assessment of the effects of different preprocessing and noise filtering strategies on psychophysiological interactions (PPI) methods for analyzing fMRI data where noise management has not yet been established. METHODS: Both real and simulated fMRI data were used to assess these effects. Four regions of interest (ROIs) were chosen for the PPI analysis on the basis of their engagement during two tasks. PPI analysis was performed for 32 different preprocessing and analysis settings, which included data filtering with RETROICOR or no such filtering; different filtering of the ROI "seed" signal with a nuisance data-driven time series; and the involvement of these data-driven time series in the subsequent PPI GLM analysis. The extent of the statistically significant results was quantified at the group level using simple descriptive statistics. Simulated data were generated to assess statistical improvement of different filtering strategies. RESULTS: We observed that different approaches for dealing with noise in PPI analysis yield differing results in real data. In simulated data, we found RETROICOR, seed signal filtering and the addition of data-driven covariates to the PPI design matrix significantly improves results. CONCLUSIONS: We recommend the use of RETROICOR, and data-driven filtering of the whole data, or alternatively, seed signal filtering with data-driven signals and the addition of data-driven covariates to the PPI design matrix.


Assuntos
Algoritmos , Mapeamento Encefálico , Encéfalo/fisiologia , Ruído , Percepção Visual/fisiologia , Adulto , Encéfalo/irrigação sanguínea , Sinais (Psicologia) , Interpretação Estatística de Dados , Tomada de Decisões/fisiologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estimulação Luminosa , Semântica , Adulto Jovem
17.
J Heart Valve Dis ; 23(2): 161-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25076545

RESUMO

BACKGROUND AND AIM OF THE STUDY: The impact of a minimally invasive approach on patient-prosthesis mismatch (PPM) in patients undergoing aortic valve replacement (AVR) remains unknown. The study aim was to identify the impact of a minimally invasive approach for AVR on the incidence of PPM. METHODS: The results of a single-center experience in 506 patients who underwent isolated AVR through a minimally invasive or conventional sternotomy were analyzed. Postoperative PPM was defined as an effective orifice area index < 0.85 cm2/m2, and was correlated with surgical approach, mortality and cardiac events after surgery. RESULTS: Overall, postoperative PPM was present in 26.0% of the patients. The ratio of PPM was 24.1% in minimal access patients and 27.7% in conventional AVR patients (p = 0.35). Hospital mortality was similar in both groups (3.8% versus 3.4%, p = 0.62). The body mass index (BMI) was higher in patients with PPM (28.5 +/- 4.4 versus 25.3 +/- 3.6 kg/m2; p = 0.0001), but obesity was significantly associated with PPM (36.3% versus 9.4%; p = 0.0001). The PPM group included more patients with a left ventricular ejection fraction (LVEF) < 0.50 (12.8% versus 5.3%; p = 0.004). The independent risk factors for PPM were increased BMI (p = 0.0001), LVEF < 0.50 (p = 0.007) and preoperative aortic stenosis (p = 0.029). A LVEF < 0.50 increased the risk for PPM by 3.77-fold (95% CI: 1.4-9.9), while a high BMI increased the risk by 1.42-fold (95% CI: 1.3-1.5). Preoperative aortic insufficiency was associated with PPM, but did not significantly increase the risk. CONCLUSION: A minimally invasive approach for AVR did not lead to an increased incidence of PPM and associated adverse events following surgery.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Esternotomia/métodos , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Bélgica/epidemiologia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Esternotomia/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
18.
Interact Cardiovasc Thorac Surg ; 7(6): 1164-6, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18650490

RESUMO

We performed surgical repair of a giant left coronary ostial aneurysm after aortic root replacement using composite valve graft (modified Bentall procedure) in a patient with Marfan syndrome. Aneurysmal formation in the left main stem itself is very rare. In order to avoid mobilizing the coronary ostium from severe adhesions after previous surgery and to reduce the tension on the anastomosis, the left main trunk was reconstructed using an interposition Dacron graft. In aortic root surgeries in Marfan patients, the size of the side hole on the composite graft should be kept relatively small to fit the diameter of the native coronary arteries for prevention of coronary buttons from forming aneurysms at the level of the coronary button anastomosis. In addition, close observation to the coronary button anastomosis is indispensable in postoperative check-up.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular , Aneurisma Coronário/etiologia , Síndrome de Marfan/complicações , Aneurisma Aórtico/etiologia , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/cirurgia , Dilatação Patológica , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Síndrome de Marfan/cirurgia , Pessoa de Meia-Idade , Polietilenotereftalatos , Desenho de Prótese , Radiografia , Reoperação , Resultado do Tratamento
19.
J Biomed Mater Res A ; 84(4): 1061-7, 2008 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-17685406

RESUMO

Nanocomposite films of ZrN-Ag were produced by reactive unbalanced magnetron sputtering, and their structural, chemical, mechanical, tribological, haemocompatibility, and antibacterial properties were studied as a function of film composition. The films formed a dense and homogeneous microstructure whereby nanocrystals of Ag are distributed evenly throughout the ZrN matrix. For small additions of silver, the hardness was found to increase, whereas the elastic modulus was found to decrease drastically. In the process of optimizing the deposition conditions, three kinds of coatings were prepared on 316 L surgical steel and tested by accelerated electrochemical polarization tests in order to detect the influence of Ag and the value of the bias potential on the corrosion performance of the system. Films produced under the optimum deposition conditions were, subsequently, deposited on medical grade Ti-Al-V and worn against ball-bearing steel using a ball-on-disk tribotester in bovine serum and were found to have superior tribological properties compared with single-phase ZrN coatings. The haemocompatibility of the films was assessed by investigating the adsorption of human serum albumin and fibrinogen on samples with different phase compositions. Quantification of the protein adsorption was carried out using spectroscopic ellipsometry, which confirmed the haemocompatibility of the films. Antibiotic activity of the films was quantified by incubating the films in bacterial cultures, namely, Staphylococcus epidermis, Staphylococcus aureus, and Escherichia coli. Films with a silver content > 10% exhibited superior antibacterial activity compared with the uncoated samples.


Assuntos
Materiais Biocompatíveis/química , Nanocompostos/química , Nitrogênio/química , Prata/química , Zircônio/química , Adsorção , Anti-Infecciosos/química , Eletroquímica/métodos , Escherichia coli/metabolismo , Humanos , Teste de Materiais , Albumina Sérica/química , Prata/farmacologia , Staphylococcus aureus/metabolismo , Staphylococcus epidermidis/metabolismo , Propriedades de Superfície
20.
Circulation ; 116(11 Suppl): I270-5, 2007 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-17846316

RESUMO

BACKGROUND: The purpose of this study was to evaluate the feasibility and effectiveness of a right video-assisted approach for atrioventricular valve disease after previous cardiac surgery. METHODS AND RESULTS: Between December 1st 1997 and May 1st 2006, 80 adults (mean age 65+/-12 years; 56% female) underwent reoperative surgery using a video-assisted approach without rib spreading. Previous cardiac operations included mitral valve (39%), CABG (29%), congenital (10%), and other (23%). For 25% of patients, this was at least their third cardiac operation. Mean time to redo surgery was 15+/-12 years. Femoral vessel cannulation and endoaortic clamping were routinely used. Mean preoperative Euroscore was 9.0+/-2.7 (5 to 20) and predicted mortality was 16.0+/-14.2% (4 to 86). Median preoperative NYHA class was II and mean follow-up was 25+/-22 months. Lung adhesions necessitated sternotomy in 4 cases and cannulation problems in another patient. Total operative mortality was 3.8% (n=3), O/E for mortality being 0.24. Procedures were mitral valve repair (45%; n=36), replacement (50%; n=40) and tricuspid valve replacement (5%; n=4). Additional procedures were performed in 44% (n=35). Mean aortic crossclamp and procedure time were 92+/-37 and 267+/-64 minutes. Mean postoperative blood loss was 815+/-1083 mL. Postoperative morbidity included 2 strokes (2.5%). Mean hospital stay was 10.7+/-6.7 days. Survival at 1 and 4 years was 93.6+/-2.8% and 85.6+/-6.4%. There was 1 late reoperation at 5 years. Median NYHA class at follow-up was II. When comparing, all but 1 patient (98.8%) preferred their minimally invasive approach when considering perioperative pain, postoperative rehabilitation, and final esthetic result. CONCLUSIONS: Video-assisted minimal access correction of atrioventricular valve disease after previous cardiac surgery is not only feasible but had lower than predicted mortality and strong patient satisfaction. It should therefore be used more frequently in today's practice.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Endoscopia/métodos , Valva Mitral/cirurgia , Reoperação/métodos , Valva Tricúspide/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Cardíacos/tendências , Endoscopia/tendências , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/cirurgia , Estudos Prospectivos , Radiografia , Reoperação/instrumentação , Reoperação/tendências , Cirurgia Torácica Vídeoassistida/métodos , Cirurgia Torácica Vídeoassistida/tendências , Valva Tricúspide/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...