Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 163
Filtrar
1.
Clin Res Cardiol ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38695900

RESUMO

BACKGROUND: Permanent pacemaker implantation (PMI) is associated with increased morbidity after transcatheter aortic valve replacement (TAVR). Cardiac resynchronization-therapy (CRT) is recommended for patients if left ventricular ejection fraction (LVEF) is ≤ 40% and ventricular pacing is expected in favor to sole right ventricular (RV) pacing. Meanwhile, LVEF may recover after TAVR in patients with aortic valve disease and the benefit of CRT is unknown. OBJECTIVE: To analyze the impact of CRT implantation as compared to RV pacing after TAVR. METHODS AND RESULTS: Between 2012 and 2022, 4385 patients (53.1% female, mean age 81 ± 6 years) without prior PMI undergoing TAVR were retrospectively identified in our institutional registry. After stratification of patients in LVEF ≤ 40%, 41-49% and ≥ 50%, Kaplan-Meier analysis revealed significantly different survival rates in each subgroup at 5 years (37.0% vs. 43.5% vs. 55.1%; P ≤ 0.021). At multivariate regression, LVEF and new PMI after TAVR were not relevant for survival. A total of 105 patients with LVEF ≤ 40% received PMI after TAVR (86 patients with RV pacing and 19 with CRT). At 5 years, all-cause mortality was significantly lower in patients with CRT-device as compared to patients without CRT-device (Kaplan Meier estimate of 21.1% vs. 48.8%; HR 0.48, CI 0.204 - 1.128; log rank p = 0.045). In multivariate analysis CRT remained a significant factor for 5-year survival in these patients (HR 0.3, CI 0.095-0.951, p = 0.041). CONCLUSION: In patients undergoing TAVR, PMI did not influence 5-year survival. In patients with LVEF ≤ 40%, CRT-device implantation was associated with improved survival compared to non-CRT-device implantation.

3.
Artigo em Inglês | MEDLINE | ID: mdl-38632135

RESUMO

BACKGROUND: Pulmonary vein (PV) occlusion is crucial for adequate lesion formation during cryoballoon-guided pulmonary vein isolation (CB-PVI). PV occlusion is usually confirmed by angiographies over the inflated balloon device. The aim of our study was to analyze the safety and efficacy of pressure waveform-based PV occlusion assessment during CB-PVI utilizing a novel fully integrated pressure analysis tool. METHODS: Consecutive patients with symptomatic atrial fibrillation (AF) scheduled for CB-PVI were prospectively enrolled for pressure waveform-based PV occlusion assessment. A patient cohort receiving conventional angiographies served as control group. Patients with common PV ostia were excluded. RESULTS: The study group consisted of 40 patients (16 females, mean age was 64.5 ± 9.7, 45% persistent AF). The control group consisted of 40 matched patients. All 160 PVs in the study group were successfully isolated without the use of additional venograms confirming PV occlusion. The mean procedure duration was 69 ± 12 min in the study group with a mean fluoroscopy duration of 11.5 ± 4.4 min. The mean contrast medium volume was 22 ± 9 ml in the study group and 36 ± 12 ml in the control group (p = 0.0001). Mean procedure duration, mean balloon temperatures, and mean ablation application durations did not differ significantly between the study and the control group. No periprocedural complications occurred. CONCLUSION: CB-PVI utilizing a fully integrated pressure waveform analysis tool to assess PV occlusion is feasible and safe and significantly reduces the amount of contrast medium without impact on procedural parameters and freedom from arrhythmia recurrence.

5.
Heart Rhythm ; 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38604590

RESUMO

BACKGROUND: The CASTLE-HTx trial demonstrated the benefit of atrial fibrillation (AF) ablation compared with medical therapy in decreasing mortality, need for left ventricular assist device implantation, or heart transplantation (HTx) in patients with end-stage heart failure (HF). OBJECTIVE: This analysis aimed to identify risk factors related to adverse outcomes in patients with end-stage HF and to assess the impact of ablation. METHODS: The CASTLE-HTx protocol randomized 194 patients with end-stage HF and AF to ablation vs medical therapy. We identified left ventricular ejection fraction <30%, New York Heart Association class ≥III, and AF burden >50% as predictors for the primary end point. The CASTLE-HTx risk score assigned weights to these risk factors. Patients with a risk score ≥3 were identified as high risk. RESULTS: The patients were assigned to low-risk (89 [45.9%]) and high-risk (105 [54.1%]) groups. After a median follow-up of 18 months, a primary end point event occurred in 6 and 31 patients of the low- and high-risk groups (hazard ratio, 4.98; 95% confidence interval, 2.08-11.9). The incidence rate (IR) difference between ablation and medical therapy was much larger in high-risk patients (8/49 [IR, 11.4] vs 23/56 [IR, 36.1]) compared with low-risk patients (2/48 [IR, 2.6] vs 4/41 [IR, 6.3]). The IR difference for ablation was significantly higher in high-risk patients (24.69) compared with low-risk patients (3.70). CONCLUSION: The absolute benefit of ablation is more pronounced in high-risk patients, but low-risk patients may also benefit. The CASTLE-HTx risk score identifies patients with end-stage HF who will particularly benefit from ablation.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38430087

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.

7.
Europace ; 26(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38516791

RESUMO

AIMS: Pulmonary vein isolation (PVI) for catheter ablation of atrial fibrillation (AF) is a time-demanding procedure. High-power short-duration (HPSD) ablation protocols and high-density mapping catheters have recently been introduced to clinical practice. We investigated the impact of high-density mapping and HPSD ablation protocols on procedural timing, efficacy, and safety by comparing different standardized set-ups. METHODS AND RESULTS: Three electrophysiology (EP) laboratory set-ups were analysed: (i) circular catheter for mapping and HPSD ablation with 30/35 W guided by an ablation index (AI); (ii) pentaspline catheter for mapping an HPSD ablation with 50 W guided by an AI; and (iii) pentaspline catheter for mapping and HPSD ablation with 90 W over 4 s using a novel ablation catheter. All patients underwent PVI without additional left atrial ablation strategies. Procedural data and operating intervals in the EP laboratory were systematically analysed. Three hundred seven patients were analysed (30/35 W AI: n = 102, 50 W AI: n = 102, 90 W/4 s: n = 103). Skin-to-skin times [105.3 ± 22.7 (30/35 W AI) vs. 81.4 ± 21.3 (50 W AI) vs. 69.5 ± 12.2 (90 W/4 s) min, P ≤ 0.001] and total laboratory times (132.8 ± 42.1 vs. 107.4 ± 25.7 vs. 95.2 ± 14.0 min, P < 0.001) significantly differed among the study groups. Laboratory interval analysis revealed significant shortening of mapping and ablation times. Arrhythmia-free survival after 12 months was not different among the study groups (log-rank P = 0.96). CONCLUSION: The integration of high-density mapping and HPSD protocols into an institutional AF ablation process resulted in reduced procedure times without compromising safety or efficacy.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fluxo de Trabalho , Átrios do Coração , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Recidiva
9.
Arch Gynecol Obstet ; 309(1): 329-337, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37597024

RESUMO

OBJECTIVE: International guidelines recommend vaginal pessaries as a first-choice treatment of symptomatic pelvic organ prolapse (POP). Gynecologists rarely receive systematic training or just do not take the time to communicate with their patients. We hypothesized that we could identify key deficits and limitations of counseling before or during pessary therapy from questions directed to manufacturers with the aim to improve and promote health literacy of women with POP. METHODS: We approached five manufacturers to provide anonymized inquiries related to pessary use. After exclusion of duplicates and questions about obstetric pessaries, 174 data sets from 145 patients remained. RESULTS: In 19/145 patients (13.1%), a 2nd degree, and in 94/145 (64.8%), a 3rd-4th degree of POP was identified. Four patients had additional urinary incontinence. In 32/145 (22.1%), the severity of POP could not be identified. The age of patients ranged from 27 to 98 (mean = 63.7) years. Most inquiries were related to the selected pessary models or sizes (40/174; 22.9%), self-management (20/174; 11.5%), and technical aspects such as shelf life or appropriate cleaning (26/174; 14.9%). Pain or voiding dysfunction was present in 17/174 remarks (9.7%). Lifestyle questions related to the use of pessaries during sport, menstruation, or mechanical anticonception. The cube pessary was in the focus of interest followed by the sieve bowl, urethra, ring, and Gellhorn device. The list of questions was summarized as a checklist stratified according to priorities. CONCLUSION: The checklist should help improve counseling and self-management of patients to optimize the benefit/risk ratio of conservative treatment of pelvic floor diseases.


Assuntos
Prolapso de Órgão Pélvico , Médicos , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Pessários , Lista de Checagem , Promoção da Saúde , Prolapso de Órgão Pélvico/terapia , Resultado do Tratamento
10.
PeerJ ; 11: e16248, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38077425

RESUMO

The threespine stickleback (Gasterosteus aculeatus) is an important model for studying the evolution of nuptial coloration, but histological analyses of color are largely lacking. Previous analyses of one nuptial coloration trait, orange-red coloration along the body, have indicated carotenoids are the main pigment producing this color. In addition, recent gene expression studies found variation in the correlates of throat coloration between the sexes and between populations, raising the possibility of variation in the mechanisms underlying superficially similar coloration. We used transmission electron microscopy (TEM) to investigate the histological correlates of color in the throat dermal tissue of threespine stickleback from Western North America, within and between sexes, populations, and ecotypes. Ultrastructural analysis revealed carotenoid-containing erythrophores to be the main chromatophore component associated with orange-red coloration in both males and females across populations. In individuals where some darkening of the throat tissue was present, with no obvious orange-red coloration, erythrophores were not detected. Melanophore presence was more population-specific in expression, including being the only chromatophore component detected in a population of darker fish. We found no dermal chromatophore units within colorless throat tissue. This work confirms the importance of carotenoids and the erythrophore in producing orange-red coloration across sexes, as well as melanin within the melanophore in producing darkened coloration, but does not reveal broad histological differences among populations with similar coloration.


Assuntos
Cromatóforos , Smegmamorpha , Feminino , Masculino , Animais , Faringe , Smegmamorpha/genética , Peixes , Carotenoides
11.
Pacing Clin Electrophysiol ; 46(12): 1586-1594, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37943015

RESUMO

Pulsed field ablation (PFA) is a promising technology for the treatment of atrial fibrillation (AF). Due to its unique tissue selectivity, PFA potentially bears superior characteristics as compared to established thermal energy sources in AF ablation procedures. Cardiovascular magnetic resonance imaging (CMR) using late gadolinium enhancement (LGE) is an established tool in the analysis of myocardial fibrosis representing atrial cardiomyopathy as well as ablation-induced atrial scar formation following catheter ablation with thermal energy. Mechanisms of atrial lesion formation differ between thermal ablation and electroporation and its impact on results of CMR imaging are not fully understood until now. In this review article, the potential of CMR imaging for PFA lesion assessment and available data are discussed. Further, additional needs to adopt imaging approaches to the cellular mechanisms of electroporation are considered.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Meios de Contraste , Gadolínio , Imageamento por Ressonância Magnética/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Átrios do Coração/patologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/cirurgia , Ablação por Cateter/métodos
12.
JAMA Cardiol ; 8(12): 1142-1151, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37910101

RESUMO

Importance: Previous studies evaluating the association of patient sex with clinical outcomes using conventional thermal ablative modalities for atrial fibrillation (AF) such as radiofrequency or cryoablation are controversial due to mixed results. Pulsed field ablation (PFA) is a novel AF ablation energy modality that has demonstrated preferential myocardial tissue ablation with a unique safety profile. Objective: To compare sex differences in patients undergoing PFA for AF in the Multinational Survey on the Methods, Efficacy, and Safety on the Postapproval Clinical Use of Pulsed Field Ablation (MANIFEST-PF) registry. Design, Setting, and Participants: This was a retrospective cohort study of MANIFEST-PF registry data, which included consecutive patients undergoing postregulatory approval treatment with PFA to treat AF between March 2021 and May 2022 with a median follow-up of 1 year. MANIFEST-PF is a multinational, retrospectively analyzed, prospectively enrolled patient-level registry including 24 European centers. The study included all consecutive registry patients (age ≥18 years) who underwent first-ever PFA for paroxysmal or persistent AF. Exposure: PFA was performed on patients with AF. All patients underwent pulmonary vein isolation and additional ablation, which was performed at the discretion of the operator. Main Outcomes and Measures: The primary effectiveness outcome was freedom from clinically documented atrial arrhythmia for 30 seconds or longer after a 3-month blanking period. The primary safety outcome was the composite of acute (<7 days postprocedure) and chronic (>7 days) major adverse events (MAEs). Results: Of 1568 patients (mean [SD] age, 64.5 [11.5] years; 1015 male [64.7%]) with AF who underwent PFA, female patients, as compared with male patients, were older (mean [SD] age, 68 [10] years vs 62 [12] years; P < .001), had more paroxysmal AF (70.2% [388 of 553] vs 62.4% [633 of 1015]; P = .002) but had fewer comorbidities such as coronary disease (9% [38 of 553] vs 15.9% [129 of 1015]; P < .001), heart failure (10.5% [58 of 553] vs 16.6% [168 of 1015]; P = .001), and sleep apnea (4.7% [18 of 553] vs 11.7% [84 of 1015]; P < .001). Pulmonary vein isolation was performed in 99.8% of female (552 of 553) and 98.9% of male (1004 of 1015; P = .90) patients. Additional ablation was performed in 22.4% of female (124 of 553) and 23.1% of male (235 of 1015; P = .79) patients. The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was similar in male and female patients (79.0%; 95% CI, 76.3%-81.5% vs 76.3%; 95% CI, 72.5%-79.8%; P = .28). There was also no significant difference in acute major AEs between groups (male, 1.5% [16 of 1015] vs female, 2.5% [14 of 553]; P = .19). Conclusion and Relevance: Results of this cohort study suggest that after PFA for AF, there were no significant sex differences in clinical effectiveness or safety events.


Assuntos
Fibrilação Atrial , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Adolescente , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Estudos de Coortes , Fatores Sexuais , Resultado do Tratamento
13.
Herzschrittmacherther Elektrophysiol ; 34(4): 298-304, 2023 Dec.
Artigo em Alemão | MEDLINE | ID: mdl-37855890

RESUMO

Catheter ablation of ventricular tachycardia (VTs) has emerged as an effective treatment modality. Ablation procedures for idiopathic VTs depends on the anatomical origin of the arrhythmias, is highly effective in certain cases, and has been implemented as a first-line therapy in recent European guidelines. In contrast, catheter ablation of VTs in patients with structural heart disease has a significant risk of arrhythmia recurrence. Interventional treatment for patients with ischemic cardiomyopathy was studied in multiple randomized multicenter trials and it was shown that catheter ablation was more effective in arrhythmia suppression compared to conservative treatment modalities. Catheter ablation of nonischemic cardiomyopathy suffers from far higher rates of arrhythmia recurrences as documented in several long-term studies and often needs complex procedures with or without epicardial mapping and ablation. There is still no clear proof of a mortality benefit from catheter ablation of VTs in patients with or without structural heart disease. Nevertheless, recent guidelines recommend catheter ablation as an alternative to implantation of cardioverter-defibrillators (ICD) in selected cases.


Assuntos
Cardiomiopatias , Ablação por Cateter , Desfibriladores Implantáveis , Cardiopatias , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/cirurgia , Resultado do Tratamento , Cardiomiopatias/cirurgia , Ablação por Cateter/métodos
14.
Pacing Clin Electrophysiol ; 46(12): 1553-1564, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37885302

RESUMO

BACKGROUND: Targeting individual sources identified during atrial fibrillation (AF) has been used as an ablation strategy with varying results. OBJECTIVE: Aim of this study was to evaluate the relationship between regions of interest (ROIs) from CARTOFINDER (CF) mapping and atrial cardiomyopathy from late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR). METHODS: Twenty consecutive patients underwent index catheter ablation for persistent AF (PERS AF). Pre-processed LGE CMR images were merged with the results from CF mapping to visualize harboring regions for focal and rotational activities. Atrial cardiomyopathy was classified based on the four Utah stages. RESULTS: Procedural success was achieved in all patients (n = 20, 100%). LGE CMR revealed an intermediate amount of 21.41% ± 6.32% for LA fibrosis. ROIs were identified in all patients (mean no ROIs per patient n = 416.45 ± 204.57). A tendency towards a positive correlation between the total amount of atrial cardiomyopathy and the total number of ROIs per patient (regression coefficient, ß = 10.86, p = .15) was observed. The degree of fibrosis and the presence of ROIs per segment showed no consistent spatial correlation (posterior: ß = 0.36, p-value (p) = .24; anterior: ß = -0.08, p = .54; lateral: ß = 0.31, p = 39; septal: ß = -0.12; p = .66; right PVs: ß = 0.34, p = .27; left PVs: ß = 0.07, p = .79; LAA: ß = -0.91, p = .12). 12 months AF-free survival was 70% (n = 14) after ablation. CONCLUSION: The presence of ROIs from CF mapping was not directly associated with the extent and location of fibrosis. Further studies evaluating the relationship between focal and rotational activity and atrial cardiomyopathy are mandatory.


Assuntos
Fibrilação Atrial , Cardiomiopatias , Ablação por Cateter , Humanos , Ablação por Cateter/métodos , Meios de Contraste , Fibrose , Gadolínio , Átrios do Coração , Imageamento por Ressonância Magnética/métodos
15.
Balkan Med J ; 40(6): 386-394, 2023 10 20.
Artigo em Inglês | MEDLINE | ID: mdl-37817408

RESUMO

Catheter ablation has emerged as an effective treatment for atrial arrhythmias, and pulmonary vein isolation (PVI) is the cornerstone of ablation strategies. Significant technological evolution and widespread increase in operator experience have facilitated the effectiveness of catheter ablation to achieve durable PVIs in single or multiple ablation procedures. Nevertheless, arrhythmia recurrence is a common problem even after establishing PVI. Data on catheter ablation in these patients are sparse and repeat ablation in this population is highly challenging. In this review we have summarized the available data as well as potential strategies of catheter ablation following the initial PVI.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Ablação por Cateter/métodos , Recidiva
16.
N Engl J Med ; 389(15): 1380-1389, 2023 Oct 12.
Artigo em Inglês | MEDLINE | ID: mdl-37634135

RESUMO

BACKGROUND: The role of catheter ablation in patients with symptomatic atrial fibrillation and end-stage heart failure is unknown. METHODS: We conducted a single-center, open-label trial in Germany that involved patients with symptomatic atrial fibrillation and end-stage heart failure who were referred for heart transplantation evaluation. Patients were assigned to receive catheter ablation and guideline-directed medical therapy or medical therapy alone. The primary end point was a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation. RESULTS: A total of 97 patients were assigned to the ablation group and 97 to the medical-therapy group. The trial was stopped for efficacy by the data and safety monitoring board 1 year after randomization was completed. Catheter ablation was performed in 81 of 97 patients (84%) in the ablation group and in 16 of 97 patients (16%) in the medical-therapy group. After a median follow-up of 18.0 months (interquartile range, 14.6 to 22.6), a primary end-point event had occurred in 8 patients (8%) in the ablation group and in 29 patients (30%) in the medical-therapy group (hazard ratio, 0.24; 95% confidence interval [CI], 0.11 to 0.52; P<0.001). Death from any cause occurred in 6 patients (6%) in the ablation group and in 19 patients (20%) in the medical-therapy group (hazard ratio, 0.29; 95% CI, 0.12 to 0.72). Procedure-related complications occurred in 3 patients in the ablation group and in 1 patient in the medical-therapy group. CONCLUSIONS: Among patients with atrial fibrillation and end-stage heart failure, the combination of catheter ablation and guideline-directed medical therapy was associated with a lower likelihood of a composite of death from any cause, implantation of a left ventricular assist device, or urgent heart transplantation than medical therapy alone. (Funded by Else Kröner-Fresenius-Stiftung; CASTLE-HTx ClinicalTrials.gov number, NCT04649801.).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Humanos , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Alemanha , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Encaminhamento e Consulta , Resultado do Tratamento
17.
J Interv Card Electrophysiol ; 66(9): 2125-2133, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37145294

RESUMO

BACKGROUND: Cryoballoon (CB)-guided pulmonary vein isolation (PVI) is an established treatment for atrial fibrillation (AF). This observational study aimed to assess the role of individual anatomical characteristics to predict long-term freedom from arrhythmia recurrence after CB-guided PVI for paroxysmal AF (PAF). METHODS: Three hundred fifty three consecutive patients (58 ± 11 years, 56% males), undergoing PVI between 2012 and 2018 were analysed. Individual pulmonary vein (PV) anatomy was assessed using preprocedural cardiac magnetic resonance imaging (MRI). For each PV, the cross-sectional area (CSA) was calculated. The impact of PV characteristics and CSA on long-term AF-free survival was evaluated. RESULTS: Acute PVI was achieved in all patients. Two hundred twenty-three patients (63%) had a normal PV anatomy (2 left- and 2 right-sided PV). Variant PV anatomy was present in 130 patients (37%). During the observation period of 48 months, AF-recurrence was documented in 167 patients (47 %). Patients with AF-recurrence presented with significantly enlarged right-sided PVs and left superior PVs (LSPVs) (p < 0.001). The presence of left common PVs (LCPVs) (n = 75, Log-rank p < 0.001) as well as right variant PVs (n = 35, Log rank p < 0.001) was associated with a significantly impaired long-term AF-free survival rate as compared to patients with normal PV characteristics. CONCLUSION: Variant PV anatomy is a good predictor for AF-recurrence. A correlation between an enlarged CSA of right-sided PVs as well as LSPVs and AF-recurrence was documented.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Imageamento por Ressonância Magnética , Resultado do Tratamento , Ablação por Cateter/métodos , Recidiva
18.
Circulation ; 148(1): 35-46, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37199171

RESUMO

BACKGROUND: Pulsed field ablation is a novel nonthermal cardiac ablation modality using ultra-rapid electrical pulses to cause cell death by a mechanism of irreversible electroporation. Unlike the traditional ablation energy sources, pulsed field ablation has demonstrated significant preferentiality to myocardial tissue ablation, and thus avoids certain thermally mediated complications. However, its safety and effectiveness remain unknown in usual clinical care. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a retrospective, multinational, patient-level registry wherein patients at each center were prospectively included in their respective center registries. The registry included all patients undergoing postapproval treatment with a multielectrode 5-spline pulsed field ablation catheter to treat atrial fibrillation (AF) between March 1, 2021, and May 30, 2022. The primary effectiveness outcome was freedom from clinical documented atrial arrhythmia (AF/atrial flutter/atrial tachycardia) of ≥30 seconds on the basis of electrocardiographic data after a 3-month blanking period (on or off antiarrhythmic drugs). Safety outcomes included the composite of acute (<7 days postprocedure) and latent (>7 days) major adverse events. RESULTS: At 24 European centers (77 operators) pulsed field ablation was performed in 1568 patients with AF: age 64.5±11.5 years, female 35%, paroxysmal/persistent AF 65%/32%, CHA2DS2-VASc 2.2±1.6, median left ventricular ejection fraction 60%, and left atrial diameter 42 mm. Pulmonary vein isolation was achieved in 99.2% of patients. After a median (interquartile range) follow-up of 367 (289-421) days, the 1-year Kaplan-Meier estimate for freedom from atrial arrhythmia was 78.1% (95% CI, 76.0%-80.0%); clinical effectiveness was more common in patients with paroxysmal AF versus persistent AF (81.6% versus 71.5%; P=0.001). Acute major adverse events occurred in 1.9% of patients. CONCLUSIONS: In this large observational registry of the postapproval clinical use of pulsed field technology to treat AF, catheter ablation using pulsed field energy was clinically effective in 78% of patients with AF.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda , Resultado do Tratamento , Flutter Atrial/etiologia , Sistema de Registros , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
20.
Pacing Clin Electrophysiol ; 46(7): 714-716, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37247251

RESUMO

BACKGROUND: Pulsed field ablation (PFA) results in unique lesion formation, but there is lack of in-vivo validation in terms of scar formation following atrial fibrillation (AF) ablation. OBJECTIVE: We aimed to access atrial lesion formation based on late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR) following PFA for pulmonary vein (PV) and posterior wall isolation (PWI). METHODS: AF ablation was performed in 10 patients using a 31 mm pentaspline PFA catheter. After pulmonary vein isolation (PVI; n = 8 PFA-applications/ PV; n = 4 in basket and n = 4 in flower configuration), another eight applications in flower configuration were conducted for concomitant PWI. Patients underwent LGE CMR 3 months after ablation aiming for quantification of left atrial (LA) scar. RESULTS: Acute procedural success was achieved in all patients. Mean procedure duration was 62 ± 7 min. and mean LA dwell time of the PFA catheter was 13 ± 2 min. Mean post ablation total LA scar burden was 8.1 ± 2.1% and mean scar width was 12.8 ± 2.1 mm. At the posterior LA, 22.6 ± 2.2% of the anatomical segment resulted in chronic scar tissue, concentrated at the PW. Postablation CMR found no evidence for PV stenosis or collateral damage of adjacent structures. At 7 months of follow-up, 9/10 patients (90%) were free from arrhythmia recurrence. CONCLUSION: PFA for AF resulted in durable and transmural atrial scar tissue at the PVs and PW. LGE CMR found a very homogeneous and contiguous lesion pattern with no signs for collateral damage.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Cicatriz/cirurgia , Meios de Contraste , Veias Pulmonares/cirurgia , Gadolínio , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Átrios do Coração/patologia , Ablação por Cateter/métodos , Resultado do Tratamento , Recidiva
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...