J Cardiovasc Magn Reson ; 18(1): 86, 2016 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-27846914

RESUMO

There were 116 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2015, which is a 14 % increase on the 102 articles published in 2014. The quality of the submissions continues to increase. The 2015 JCMR Impact Factor (which is published in June 2016) rose to 5.75 from 4.72 for 2014 (as published in June 2015), which is the highest impact factor ever recorded for JCMR. The 2015 impact factor means that the JCMR papers that were published in 2013 and 2014 were cited on average 5.75 times in 2015. The impact factor undergoes natural variation according to citation rates of papers in the 2 years following publication, and is significantly influenced by highly cited papers such as official reports. However, the progress of the journal's impact over the last 5 years has been impressive. Our acceptance rate is <25 % and has been falling because the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. For this reason, the Editors have felt that it is useful once per calendar year to summarize the papers for the readership into broad areas of interest or theme, so that areas of interest can be reviewed in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality papers to JCMR for publication.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Imageamento por Ressonância Magnética , Publicações Periódicas como Assunto , Animais , Bibliometria , Doenças Cardiovasculares/patologia , Doenças Cardiovasculares/fisiopatologia , Doenças Cardiovasculares/terapia , Políticas Editoriais , Humanos , Fator de Impacto de Revistas , Valor Preditivo dos Testes , Prognóstico
2.
J Cardiovasc Magn Reson ; 18: 2, 2016 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-26738482

RESUMO

BACKGROUND: In vivo cardiac diffusion tensor imaging (cDTI) is uniquely capable of interrogating laminar myocardial dynamics non-invasively. A comprehensive dataset of quantative parameters and comparison with subject anthropometrics is required. METHODS: cDTI was performed at 3T with a diffusion weighted STEAM sequence. Data was acquired from the mid left ventricle in 43 subjects during the systolic and diastolic pauses. Global and regional values were determined for fractional anisotropy (FA), mean diffusivity (MD), helix angle gradient (HAg, degrees/%depth) and the secondary eigenvector angulation (E2A). Regression analysis was performed between global values and subject anthropometrics. RESULTS: All cDTI parameters displayed regional heterogeneity. The RR interval had a significant, but clinically small effect on systolic values for FA, HAg and E2A. Male sex and increasing left ventricular end diastolic volume were associated with increased systolic HAg. Diastolic HAg and systolic E2A were both directly related to left ventricular mass and body surface area. There was an inverse relationship between E2A mobility and both age and ejection fraction. CONCLUSIONS: Future interpretations of quantitative cDTI data should take into account anthropometric variations observed with patient age, body surface area and left ventricular measurements. Further work determining the impact of technical factors such as strain and SNR is required.


Assuntos
Antropometria , Imagem de Tensor de Difusão , Coração/anatomia & histologia , Coração/fisiologia , Função Ventricular Esquerda , Adulto , Fatores Etários , Idoso , Análise de Variância , Anisotropia , Superfície Corporal , Diástole , Feminino , Voluntários Saudáveis , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Fatores Sexuais , Volume Sistólico , Sístole , Adulto Jovem
3.
J Cardiovasc Magn Reson ; 17: 99, 2015 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-26589839

RESUMO

There were 102 articles published in the Journal of Cardiovascular Magnetic Resonance (JCMR) in 2014, which is a 6% decrease on the 109 articles published in 2013. The quality of the submissions continues to increase. The 2013 JCMR Impact Factor (which is published in June 2014) fell to 4.72 from 5.11 for 2012 (as published in June 2013). The 2013 impact factor means that the JCMR papers that were published in 2011 and 2012 were cited on average 4.72 times in 2013. The impact factor undergoes natural variation according to citation rates of papers in the 2 years following publication, and is significantly influenced by highly cited papers such as official reports. However, the progress of the journal's impact over the last 5 years has been impressive. Our acceptance rate is <25% and has been falling because the number of articles being submitted has been increasing. In accordance with Open-Access publishing, the JCMR articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. For this reason, the Editors have felt that it is useful once per calendar year to summarize the papers for the readership into broad areas of interest or theme, so that areas of interest can be reviewed in a single article in relation to each other and other recent JCMR articles. The papers are presented in broad themes and set in context with related literature and previously published JCMR papers to guide continuity of thought in the journal. We hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality papers to JCMR for publication.


Assuntos
Pesquisa Biomédica , Cardiologia , Doenças Cardiovasculares/diagnóstico , Imageamento por Ressonância Magnética , Publicações Periódicas como Assunto , Animais , Bibliometria , Pesquisa Biomédica/estatística & dados numéricos , Cardiologia/estatística & dados numéricos , Doenças Cardiovasculares/patologia , Doenças Cardiovasculares/fisiopatologia , Políticas Editoriais , Humanos , Fator de Impacto de Revistas , Imageamento por Ressonância Magnética/estatística & dados numéricos , Publicações Periódicas como Assunto/estatística & dados numéricos , Valor Preditivo dos Testes , Prognóstico , Índice de Gravidade de Doença , Fatores de Tempo
4.
Phlebology ; 27(7): 352-9, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22156366

RESUMO

OBJECTIVE: Assessment and optimization of intermittent pneumatic compression (IPC) devices for prophylaxis of deep vein thrombosis has previously used duplex ultrasound. The aim was to investigate novel magnetic resonance (MR) venous velocity mapping (VM) for IPC research and development. METHODS: Twelve normal subjects were scanned in the supine position using realtime MR VM with sequential foot and calf IPC (120 mmHg) at 1.5 T. Measurements were taken in the popliteal vein at baseline using both cuffs and each cuff individually recording 60 seconds continuously. Temporal resolution was 310 ms per independent image, at 1 × 1 mm spatial resolution. RESULTS: Peak velocity (V(p)) measurements: baseline, V(p) = 2.1 cm/second (range = 1.1-3.5); using both compression cuffs, V(p) = 41.5 cm/second (18.0-58.1); calf cuff alone, V(p) = 40.6 cm/second (18.1-62.2); foot cuff alone, V(p) = 7.9 cm/second (4.2-15.3). Flow volume measurements per compression cycle (F): baseline, F = 2.3 cm³ (0.5-11.4); both compression cuffs, F = 7.1 cm³ (2.5-24.6); calf cuff only, F = 7.1 cm³ (2.4-24.5); foot cuff only, F = 2.6 cm³ (0.9-10.7). The foot cuff contribution was insignificant when combined with the calf cuff (P < 0.01). The MR venous VM results were similar to those reported elsewhere using ultrasound. CONCLUSION: This novel technique for MR venous VM can measure the realtime variations in venous blood flow during IPC.


Assuntos
Dispositivos de Compressão Pneumática Intermitente , Imageamento por Ressonância Magnética/métodos , Flebografia/métodos , Veias/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Bandagens Compressivas , Feminino , Pé/irrigação sanguínea , Pé/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Perna (Membro)/irrigação sanguínea , Perna (Membro)/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Veia Poplítea/diagnóstico por imagem , Pressão , Decúbito Dorsal , Fatores de Tempo , Ultrassonografia Doppler Dupla , Trombose Venosa/patologia
5.
Magn Reson Med ; 64(4): 1015-26, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20593372

RESUMO

A fully automatic and highly efficient free-breathing navigator gated technique, continuously adaptive windowing strategy (CLAWS), is presented. Using a novel and dynamic acquisition strategy that ensures all potential navigator acceptance windows are possible, CLAWS acquires an image with the highest possible efficiency regardless of variations in the respiratory pattern. Unnecessary prolongation of scan durations due to respiratory drift or navigator acceptance window adjustments are avoided. As CLAWS requires no setting of the acceptance window, nor monitoring of the navigator traces during the scan, operator dependence is minimized and ease of use improved. CLAWS was compared against a standard accept/reject algorithm (ARA) and an end-expiratory following ARA (EE-ARA) in 20 healthy subjects and 10 patients (ARA only). The respiratory efficiency was compared against the retrospectively determined best possible respiratory efficiency for each acquisition. On average, the difference between CLAWS scan times and best possible scan times was 0.6% (± 1.3%). For the ARA and EE-ARA techniques, mean differences were 14.4% (± 20.9%) and 32.6 ± 10.9%, respectively. Had the CLAWS algorithm been used with the ARA and EE-ARA traces, mean differences would have been 0.2% (± 1.1%) and 0.5% (± 1.7%), respectively. Image quality was the same for all techniques: respiratory gating, motion artifacts, navigator, and coronary artery imaging.


Assuntos
Algoritmos , Vasos Coronários/patologia , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Mecânica Respiratória , Técnicas de Imagem de Sincronização Respiratória/métodos , Adolescente , Adulto , Idoso , Inteligência Artificial , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
6.
J Cardiovasc Magn Reson ; 12: 15, 2010 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-20302618

RESUMO

There were 56 articles published in the Journal of Cardiovascular Magnetic Resonance in 2009. The editors were impressed with the high quality of the submissions, of which our acceptance rate was about 40%. In accordance with open-access publishing, the articles go on-line as they are accepted with no collating of the articles into sections or special thematic issues. We have therefore chosen to briefly summarise the papers in this article for quick reference for our readers in broad areas of interest, which we feel will be useful to practitioners of cardiovascular magnetic resonance (CMR). In some cases where it is considered useful, the articles are also put into the wider context with a short narrative and recent CMR references. It has been a privilege to serve as the Editor of the JCMR this past year. I hope that you find the open-access system increases wider reading and citation of your papers, and that you will continue to send your quality manuscripts to JCMR for publication.


Assuntos
Doenças Cardiovasculares/diagnóstico , Imageamento por Ressonância Magnética , Doenças Cardiovasculares/fisiopatologia , Doenças Cardiovasculares/terapia , Humanos , Publicações Periódicas como Assunto , Valor Preditivo dos Testes , Prognóstico
7.
Br J Radiol ; 82 Spec No 1: S24-32, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20348532

RESUMO

Human right coronary artery (RCA) haemodynamics is investigated using computational fluid dynamics (CFD) based on subject-specific information from magnetic resonance (MR) acquisitions. The dynamically varying vascular geometry is reconstructed from MR images, incorporated in CFD in conjunction with pulsatile flow conditions obtained from MR velocity mapping performed on the same subject. The effects of dynamic vessel motion on instantaneous and cycle-averaged haemodynamic parameters, such as wall shear stress (WSS), time-averaged WSS (TAWSS) and oscillatory shear index (OSI), are examined by comparing an RCA model with a time-varying geometry and those with a static geometry, corresponding to nine different time-points in the cardiac cycle. The results show that the TAWSS is similar for the dynamic and static wall models, both qualitatively and quantitatively (correlation coefficient 0.89-0.95). Conversely, the OSI shows much poorer correlations (correlation coefficient 0.38-0.60), with the best correspondence being observed with the static models constructed from images acquired in late diastole (at t = 0 and 800 ms, the cardiac cycle is 900 ms). These findings suggest that neglecting dynamic motion of the RCA is acceptable if TAWSS is the primary focus but may result in underestimation of haemodynamic parameters related to the oscillatory nature of the blood flow.


Assuntos
Vasos Coronários/fisiologia , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Vasos Coronários/anatomia & histologia , Hemodinâmica , Hemorreologia/fisiologia , Humanos , Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Masculino , Modelos Cardiovasculares , Movimento (Física) , Fluxo Pulsátil/fisiologia , Estresse Mecânico
8.
Proc Inst Mech Eng H ; 222(4): 475-85, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18595359

RESUMO

A detailed investigation of left ventricle (LV) flow patterns could improve our understanding of the function of the heart and provide further insight into the mechanisms of heart failure. This study presents patient-specific modelling with magnetic resonance imaging (MRI) to investigate LV blood flow patterns in normal subjects. In the study, the prescribed LV wall movements based on the MRI measurements drove the blood flow in and out of the LV in computational fluid dynamics simulation. For the six subjects studied, the simulated LV flow swirls towards the aortic valve and is ejected into the ascending aorta with a vertical flow pattern that follows the left-hand rule. In diastole, the inflow adopts a reasonably straight route (with no significant secondary flow) towards the apex in the rapid filling phase with slight variations in the jet direction between different cases. When the jet reaches about two thirds of the distance from the inflow plane to the apex, the blood flow starts to change direction and swirls towards the apex. In the more slowly filling phase, a centrally located jet is evident with vortices located on both sides of the jet on an anterior-posterior plane that passes through the mitral and aortic valves. In the inferior-superior plane, a main vortex appears for most of the cases in which an anticlockwise vortex appears for three cases and a clockwise vortex occurs for one case. The simulated flow patterns agree well qualitatively with MRI-measured flow fields.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Cardiovasculares , Volume Sistólico/fisiologia , Função Ventricular , Simulação por Computador , Ventrículos do Coração/anatomia & histologia , Humanos
9.
Med Phys ; 33(7): 2621-31, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16898466

RESUMO

Combined in vitro experiments and numerical simulations were performed to study flow artifacts in phase contrast (PC) velocity mapping of steady flow through an anatomically realistic aortocoronary bypass graft model. The geometry was obtained through imaging and computational reconstruction of a left anterior descending (LAD) coronary artery of a porcine heart. Simulated images of through-plane velocity were obtained at selected slices of the geometry. These were then compared and contrasted with velocity images of corresponding sites that were obtained from in vitro experiments. The shift and distortion of the measured velocity profile was well predicted by the simulation, while trajectories obtained from particle tracking were shown to be useful in understanding the origins of the flow artifacts that were observed.


Assuntos
Ponte de Artéria Coronária , Vasos Coronários/patologia , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Algoritmos , Animais , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Circulação Coronária , Interpretação de Imagem Assistida por Computador , Processamento de Imagem Assistida por Computador , Modelos Cardiovasculares , Modelos Teóricos , Radiografia , Software , Suínos
10.
Atherosclerosis ; 183(2): 361-6, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16285999

RESUMO

PURPOSE: To determine, in asymptomatic subjects, the inter-study reproducibility of a three-dimensional (3D) volume selective fast spin echo (FSE) cardiovascular magnetic resonance sequence for the assessment of carotid artery wall volume as a measure of atheroma burden. METHODS: Inter-study reproducibility was evaluated in 16 asymptomatic volunteers (10 male, 6 female). Both carotid arteries were scanned twice with a median inter-scan time of 5 days. The images were acquired in cross-section, and the total carotid arterial wall volume (TWV) was calculated by subtraction of the total carotid lumen volume from the total outer carotid vessel volume. RESULTS: The mean carotid T1-weighted TWV for the first and second scans was 828 and 821 mm(3), respectively (mean difference 7 mm(3), p=0.45). The standard deviation (S.D.) of the differences between the measurements was 38 mm(3) yielding an inter-study coefficient of variation of 4.6%. The time for each study was approximately 30 min. For the longitudinal evaluation of carotid atheroma burden with pharmacological intervention versus placebo, 32 subjects would enable a difference of 38 mm(3) to be detected with a significance level of 5% with 80% power. CONCLUSION: Volumetric analysis with carotid CMR in asymptomatic subjects using a 3D volume-selective FSE is time-efficient with good inter-study reproducibility, and is well suited for longitudinal studies of carotid atheroma with reasonable sample sizes.


Assuntos
Artéria Carótida Primitiva/anatomia & histologia , Artéria Carótida Interna/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Aterosclerose/diagnóstico , Doenças das Artérias Carótidas/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco
11.
J Cardiovasc Magn Reson ; 6(2): 517-25, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15137336

RESUMO

BACKGROUND: Aortic atherosclerosis and coronary artery disease (CAD) are closely linked. Early detection of aortic atherosclerosis with the adoption of appropriate preventive measures may therefore help to reduce mortality and morbidity related to CAD. Arterial remodeling, by which the wall adapts to physiological or pathological insults by a change in vessel size, is being increasingly recognized as an important aspect of atherosclerosis. In this prospective longitudinal study we used cardiovascular magnetic resonance (CMR) to detect aortic plaque and to study aortic wall remodeling in asymptomatic subjects. METHODS: We recruited 175 healthy volunteers (49 years, 110 men) and documented their cardiovascular risk profile. Each subject underwent echocardiogram (ECG)-gated T1-weighted spin-echo imaging of the infrarenal abdominal aorta at baseline and after 2 years. FINDINGS: Of the 175 subjects who volunteered at baseline, CMR was successful in 174 (99%), with one (0.6%) failure due to claustrophobia. At 2 years, follow-up scanning was performed in 169 subjects (97%). Infrarenal aortic plaque was identified at baseline in nine (5.2%) subjects. This was reconfirmed in all nine (100%) cases at 2-year follow-up. No new cases of infrarenal plaque were identified at follow-up. The signal characteristics of the plaque on the subtracted images of the Dixon method indicate that all plaques were fibrous. In the nine subjects with infrarenal plaque, the total plaque burden increased as assessed by the total wall volume (561 to 677 mm3, p = 0.0063). The total vessel volume also increased (1737 to 1835 mm3, p = 0.031) but there was no change in the total luminal volume (1175 to 1157 mm3, p = 0.29). CONCLUSIONS: Cardiovascular magnetic resonance detects subclinical aortic atherosclerosis, can follow plaque burden over time, and confirms the presence of Glagov remodeling with preservation of the lumen despite progression of plaque. Cardiovascular magnetic resonance is well suited for the longitudinal follow-up of the general population with atherosclerosis, may help in the understanding of the natural history of atherosclerosis, and in particular may help determine factors to retard disease progression at an early stage.


Assuntos
Aorta Abdominal/patologia , Doenças da Aorta/patologia , Arteriosclerose/patologia , Imageamento por Ressonância Magnética/métodos , Estudos de Viabilidade , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
12.
Conf Proc IEEE Eng Med Biol Soc ; 2004: 1415-8, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-17271959

RESUMO

The link between atherosclerosis and wall shear stress (WSS) has lead to considerable interest in the in vivo estimation of WSS. Both magnetic resonance imaging (MRI) and three-dimensional ultrasound (3DUS) are capable of providing the anatomical and flow data required for subject-specific computational fluid dynamics (CFD) simulations. This study compares, for the first time, predicted 3D flow patterns based on black blood MRI and 3DUS. Velocity fields in the carotid arteries of nine subjects have been reconstructed, and the haemodynamic wall parameters WSS, oscillatory shear index (OSI), WSS gradients (WSSG) and angle gradients (WSSAG) were computed and compared. There was a good qualitative agreement between results derived from MRI and 3DUS, embodied by a strong linear correlation between the patched representations of the haemodynamic wall parameters. The root-mean-square error between haemodynamic wall parameters was comparable to the range of the expected variability of each imaging technique (WSS: 0.411 N/m; OSI: 0.048; temporal WSSG: 2.29 N/(s.m/sup 2/); spatial WSSG: 150 N/m/sup 3/; WSSAG: 87.6 rad/m). In conclusion, MRI and 3DUS are comparable techniques for combining with CFD in the carotid artery. The relatively high cost of MRI favour 3DUS to MRI for future haemodynamic studies of superficial arteries.

13.
Physiol Meas ; 25(6): 1495-509, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15712727

RESUMO

Atherosclerosis is a major cause of morbidity and mortality. Its apparent link with wall shear stress (WSS) has led to considerable interest in the in vivo estimation of WSS. Determining WSS by combining medical images with computational fluid dynamics (CFD) simulations can be performed both with magnetic resonance imaging (MRI) and three-dimensional ultrasound (3DUS). This study compares predicted 3D flow patterns based on black blood MRI and 3DUS. Velocity fields in the carotid arteries of nine subjects have been reconstructed, and the haemodynamic wall parameters WSS, oscillatory shear index (OSI), WSS gradients (WSSG) and angle gradients (WSSAG) were compared between the two imaging techniques. There was a good qualitative agreement between results derived from MRI and 3DUS (average correlation strength above 0.60). The root mean square error between haemodynamic wall parameters was comparable to the range of the expected variability of each imaging technique (WSS: 0.411 N m(-2); OSI: 0.048; temporal WSSG: 150 N s(-1) m(-2); spatial WSSG: 2.29 N m(-3); WSSAG: 87.6 rad m(-1)). In conclusion, MRI and 3DUS are capable of providing haemodynamic parameters when combined with CFD, and the predictions are in most cases qualitatively and quantitatively similar. The relatively high cost of MRI and continuing improvement in ultrasound favour US to MRI for future haemodynamic studies of superficial arteries.


Assuntos
Algoritmos , Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/fisiologia , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Cardiovasculares , Adulto , Artérias Carótidas/anatomia & histologia , Simulação por Computador , Ecocardiografia Tridimensional/métodos , Feminino , Humanos , Armazenamento e Recuperação da Informação/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Biomech Eng ; 125(6): 922-7, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14986421

RESUMO

The combination of computational fluid dynamics (CFD) and magnetic resonance imaging (MRI) offers a promising tool that enables the prediction of blood flow patterns in subject-specific cardiovascular models. The influence of the model geometry on the accuracy of the simulation is well recognized. This paper addresses the impact of different boundary conditions on subject-specific simulations of left ventricular (LV) flow. A novel hybrid method for prescribing effective inflow boundary conditions in the mitral valve plane has been developed. The detailed quantitative results highlight the strengths as well as the potential pitfalls of the approach.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Cardiovasculares , Função Ventricular Esquerda/fisiologia , Função Ventricular , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea , Simulação por Computador , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Med Phys ; 30(12): 3251-61, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14713092

RESUMO

Image-based Computational Fluid Dynamics (CFD) has become a popular tool for the prediction of in vivo flow profiles and hemodynamic wall parameters. Currently, Magnetic Resonance Imaging (MRI) is most widely used for in vivo geometry acquisition. For superficial arteries such as the carotids and the femoral artery, three-dimensional (3-D) extravascular ultrasound (3-DUS) could be a cost-effective alternative to MRI. In this study, nine healthy subjects were scanned both with MRI and 3-DUS. The reconstructed carotid artery geometries for each subject were compared by evaluating cross-sectional areas, centerlines, and carotid nonplanarity. Lumen areas agreed very well between the two different acquisition techniques, whereas centerlines and nonplanarity parameters showed measurable disagreement, possibly due to the different neck and head positions adopted for 3-DUS versus MRI. With the current level of agreement achieved, 3-DUS has the potential to become an inexpensive and fast alternative to MRI for image-based CFD modeling of superficial arteries.


Assuntos
Anatomia Transversal/métodos , Artérias Carótidas/anatomia & histologia , Artérias Carótidas/diagnóstico por imagem , Ecocardiografia Tridimensional/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração
16.
MAGMA ; 14(1): 39-44, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11796251

RESUMO

This paper presents an automatic method of correcting non-uniform RF coil response for the classification of body composition using MR imaging. By linear mosaic modelling, the smoothly but non-linearly varying bias field, which modulates tissue intensities within the image, was corrected. The overlapping between adjacent mosaics ensured consistent segmentation of body fat content and the effectiveness of the technique was validated by both phantom and in vivo experiments. Ten whole body composition data sets, each with 39 trans-axial slices, were acquired. Automatic segmentation results using the proposed technique were compared with those from manual delineations. The automatic segmentation method was found to be highly accurate and the mean percentage error between the two methods was less than 1.5%.


Assuntos
Tecido Adiposo/patologia , Imageamento por Ressonância Magnética/métodos , Humanos , Processamento de Imagem Assistida por Computador , Modelos Estatísticos , Músculos/patologia , Imagens de Fantasmas , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
17.
J Magn Reson Imaging ; 14(6): 677-84, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11747023

RESUMO

We evaluated free-breathing, prospective navigator-gated, three-dimensional (3D) magnetic resonance coronary angiography (MRCA) with hybrid ordered phase-encoding (HOPE), in the detection of proximal coronary artery stenosis. The coronary arteries were imaged in 46 patients undergoing cardiac catheterization. The mean scan time was 48 minutes. The mean arterial length (mm) visualized was left main stem (LMS) 11.7 (SD 4.5), left anterior descending (LAD) 30.1 (SD 11.1), circumflex (LCx) 15.5 (SD 8.6), and right (RCA) 56.2 (SD 20.8). Twenty-three patients had coronary artery disease with 47 significant stenoses on cardiac catheterization. All LMS were normal on both catheterization and MRCA. MRCA sensitivity was highest for the LAD (89% CI 65%-99%) and RCA (76% CI 50%-93%), but lower for the LCx (50% CI 21%-79%). Specificity ranged from 72%-100%. Improvements in image quality, length of vessel seen, and specific imaging of the LCx are required for MRCA to become an alternative to cardiac catheterization.


Assuntos
Estenose Coronária/diagnóstico , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
18.
Magn Reson Med ; 46(5): 1031-6, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11675659

RESUMO

Aiming for robust high-resolution free respiration coronary artery imaging, localized tracking volume selective 3D-EPI at spatial resolution 1.25 x 1.25 x 3 mm and temporal resolution 65 ms was evaluated in 14 normal subjects. Subject-specific motion tracking factors were measured between diaphragm navigator and coronary artery in S-I and A-P directions. Imaging was repeated with and without tracking, accepting 128 cardiac cycles over a 20-mm range from free breathing. Reference images with minimal respiratory motion (5-mm range) used LED-guided multiple breathholds. Depending on accurate motion measurement, coronary arteries were imaged with tracking, in a 20-mm range of free breathing, with increased scan efficiency but without significant loss of image quality compared to multiple breathhold imaging.


Assuntos
Vasos Coronários/anatomia & histologia , Imagem Ecoplanar , Imageamento Tridimensional , Humanos , Movimento (Física)
19.
Ann Biomed Eng ; 29(4): 275-83, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11339325

RESUMO

A combined computational fluid dynamics (CFD) and magnetic resonance imaging (MRI) methodology has been developed to simulate blood flow in heart chambers, with specific application in the present study to the human left ventricle. The proposed framework employs MRI scans of a human heart to obtain geometric data, which are then used for the CFD simulations. These latter are accomplished by geometrical modeling of the ventricle using time-resolved anatomical slices of the ventricular geometry and imposition of inflow/outflow conditions at orifices notionally representing the mitral and aortic valves. The predicted flow structure evolution and physiologically relevant flow characteristics were examined and compared to existing information. The CFD model convincingly captures the three-dimensional contraction and expansion phases of endocardial motion in the left ventricle, allowing simulation of dominant flow features, such as the vortices and swirling structures. These results were qualitatively consistent with previous physiological and clinical experiments on in vivo ventricular chambers, but the accuracy of the simulated velocities was limited largely by the anatomical shortcomings in the valve region. The study also indicated areas in which the methodology requires improvement and extension.


Assuntos
Circulação Coronária/fisiologia , Modelos Cardiovasculares , Adulto , Engenharia Biomédica , Simulação por Computador , Interpretação Estatística de Dados , Feminino , Ventrículos do Coração/anatomia & histologia , Hemorreologia , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Modelos Anatômicos , Função Ventricular
20.
J Magn Reson Imaging ; 13(5): 699-713, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11329191

RESUMO

A combined MR and computational fluid dynamics (CFD) study is made of flow in the upper descending thoracic aorta. The aim was to investigate further the potential of CFD simulations linked to in vivo MRI scans. The three-dimensional (3D) geometrical images of the aorta and the 3D time-resolved velocity images at the entry to the domain studied were used as boundary conditions for the CFD simulations of the flow. Despite some measurement uncertainties, comparisons between simulated and measured flow structures at the exit from the domain demonstrated encouraging levels of agreement. Moreover, the CFD simulation allowed the flow structure throughout the domain to be examined in more detail, in particular the flow separation region in the distal aortic arch and its influence on the downstream flow during late systole. Additional information such as relative pressure and wall shear stress, which could not be measured via MRI, were also extracted from the simulation. The results have encouraged further applications of the methods described. J. Magn. Reson. Imaging 2001;13:699-713.


Assuntos
Aorta Torácica/anatomia & histologia , Simulação por Computador , Hemodinâmica/fisiologia , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Gráficos por Computador , Humanos , Masculino , Análise Numérica Assistida por Computador , Valores de Referência