Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Br J Radiol ; 97(1153): 150-158, 2024 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-38263830

RESUMO

OBJECTIVES: Dynamic contrast-enhanced (DCE) MRI is not available in all imaging centres to investigate adnexal masses. We proposed modified magnetic resonance (MR) scoring system based on an assessment of the enhancement of the solid tissue on early phase postcontrast series and diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) map and investigated the validity of this protocols in the current study. MATERIALS AND METHODS: In this cross-sectional retrospective study, pelvic MRI of a total of 245 patients with 340 adnexal masses were studied based on the proposed modified scoring system and ADNEX MR scoring system. RESULTS: Modified scoring system with the sensitivity of 87.3% and specificity of 94.6% has an accuracy of 92.1%. Sensitivity, specificity, and accuracy of ADNEX MR scoring system is 96.6%, 91%, and 92.9%, respectively. The area under the receiver operating characteristic curve for the modified scoring system and ADNEX MR scoring system is 0.909 (with 0.870-0.938 95% confidence interval [CI]) and 0.938 (with 0.907-0.961 95% CI), respectively. Pairwise comparison of these area under the curves showed no significant difference (P = .053). CONCLUSIONS: Modified scoring system is less sensitive than the ADNEX MR scoring system and more specific but the accuracy is not significantly different. ADVANCES IN KNOWLEDGE: According to our study, MR scoring system based on subjective assessment of the enhancement of the solid tissue on early phase postcontrast series and DWI with ADC map could be applicable in imaging centres that DCE is not available.


Assuntos
Imageamento por Ressonância Magnética , Ovário , Humanos , Feminino , Estudos Transversais , Estudos Retrospectivos , Espectroscopia de Ressonância Magnética
2.
J Vasc Interv Radiol ; 34(7): 1184-1191.e2, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36972845

RESUMO

PURPOSE: To systematically review published studies on the pregnancy rate and outcomes after uterine artery embolization (UAE) for uterine arteriovenous malformations (UAVMs). MATERIALS AND METHODS: International medical databases were searched for all English-language studies published between 2000 and 2022 on patients with UAVMs who had undergone embolization and had a subsequent pregnancy. Data on the pregnancy rate, pregnancy complications, and physiologic status of newborns were extracted from the articles. Ten case series were included in the meta-analysis, and 18 case reports on pregnancy following UAE were reviewed. RESULTS: In the case series, 44 pregnancies were reported in 189 patients. The pooled estimate of pregnancy rate was 23.3% (95% confidence interval [CI], 17.3%-29.3%). The pregnancy rate was higher in studies of women with a mean age of ≤30 years (50.6% vs 22.2%; P < .05). The pooled estimate of live birth rate was 88.6% (95% CI, 78.6%-98.7%). CONCLUSIONS: All published series report preservation of fertility and successful pregnancies after embolization of UAVMs. The live birth rate in these series does not differ substantially from that of the general population.


Assuntos
Malformações Arteriovenosas , Embolização da Artéria Uterina , Gravidez , Humanos , Recém-Nascido , Feminino , Adulto , Embolização da Artéria Uterina/efeitos adversos , Taxa de Gravidez , Fertilidade , Malformações Arteriovenosas/diagnóstico por imagem , Malformações Arteriovenosas/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...