1.
Radiologie (Heidelb) ; 62(11): 960-970, 2022 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-36301318

RESUMO

CLINICAL/METHODOLOGICAL ISSUE: Myocardial ischemia as a reduction in perfusion with therefore oxygen deficiency of vital cardiomyocytes. Thus primary and secondary prophylaxis of myocardial infarction and it's complications. STANDARD RADIOLOGICAL METHODS: Adenosine-regadenoson stress magnetic resonance imaging (AR-stress MRI), computed tomography coronary angiography (CTCA). METHODOLOGICAL INNOVATIONS: Non-invasive stress testing using AR-stress MRI to exclude relevant obstructive coronary artery disease (CAD). PERFORMANCE: Meta-analysis: The diagnosis of obstructive CAD at the coronary artery level has a pooled sensitivity of 87.7% and a specificity of 88.6%. Diagnostic accuracy is better than single photon emission computed tomography (SPECT; AUC 0.89 vs. 0.74). ACHIEVEMENTS: AR-stress MRI can be used to assess myocardial ischemia in the setting of obstructive CAD. Current clinical guidelines for myocardial revascularization have strengthened the use of stress MRI in patients with intermediate risk of CAD and stable symptoms. Cardiac MR imaging using late gadolinium enhancement (LGE) is considered gold standard for myocardial viability assessment in vivo. Both viability and ischemia are considered prognostic factors for major adverse cardiac events. PRACTICAL RECOMMENDATIONS: AR-stress MRI is used to diagnose myocardial ischemia in combination with viability imaging (LGE). Dobutamine-atropine (DoA) stress MRI is an alternative in the setting of contraindications for AR or specific clinical questions.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Isquemia Miocárdica , Humanos , Meios de Contraste , Gadolínio , Isquemia Miocárdica/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Adenosina
2.
Rofo ; 194(2): 181-191, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34384112

RESUMO

PURPOSE: In the light of the increasing importance of cardiovascular cross-sectional imaging in current guidelines, the goal of this study is to provide a comprehensive overview of cardiovascular imaging (CVI) offered by radiological institutions across Germany. MATERIALS AND METHODS: Data were extracted from the national certification program database of the German Roentgen Society (DRG) from 2015-2021. A nationwide online survey among radiology institutes (university hospitals, non-university hospitals, and private practices) was conducted for 2019, and data was extracted from the European Society of Cardiovascular Radiology (ESCR) registry. The data collection's key points included the number of centers and individuals certified for CVI, the number of cardiac CT and MRI examinations performed, the reporting habits, and the participation in the ESCR registry. RESULTS: 71 centers and 1278 persons, both with a substantial increase since 2015, were registered and certified by the DRG to perform CVI. According to the survey, a total of 69,286 CT and 64,281 MRI examinations were performed annually. Data from the survey and the ESCR registry indicated that reporting was mostly done solely by radiologists or, to a lesser degree, in joint consensus meetings with non-radiologists. The overall participation rate in the ESCR registry was 48 % among the survey's participants. CONCLUSION: This comprehensive analysis demonstrates that high-quality CVI by radiologists is available nationwide. The current challenges are to provide the best medical and technical quality of CVI by radiology for patient care and to ensure economic sustainability in the German health care system to accommodate the predicted substantial need for CVI in the future. KEY POINTS: · High-quality advanced CVI service by radiologists is available nationwide.. · Highly qualified specialist knowledge is widely represented from university to private practices.. · Certification programs successfully contribute to the dissemination & deepening of CVI expertise.. · The ESCR registry is an established international tool for the documentation of CVI.. CITATION FORMAT: · Sieren M, Maintz D, Gutberlet M et al. Current Status of Cardiovascular Imaging in Germany: Structured Data from the National Certification Program, ESCR Registry, and Survey among Radiologists. Fortschr Röntgenstr 2022; 194: 181 - 191.


Assuntos
Radiologia , Certificação , Alemanha , Humanos , Imageamento por Ressonância Magnética/métodos , Radiologistas , Sistema de Registros
3.
ESC Heart Fail ; 8(4): 2968-2981, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33934536

RESUMO

AIMS: Failure of right ventricular (RV) function worsens outcome in pulmonary hypertension (PH). The adaptation of RV contractility to afterload, the RV-pulmonary artery (PA) coupling, is defined by the ratio of RV end-systolic to PA elastances (Ees/Ea). Using pressure-volume loop (PV-L) technique we aimed to identify an Ees/Ea cut-off predictive for overall survival and to assess hemodynamic and morphologic conditions for adapted RV function in secondary PH due to heart failure with reduced ejection fraction (HFREF). METHODS AND RESULTS: This post hoc analysis is based on 112 patients of the prospective Magdeburger Resynchronization Responder Trial. All patients underwent right and left heart echocardiography and a baseline PV-L and RV catheter measurement. A subgroup of patients (n = 50) without a pre-implanted cardiac device underwent magnetic resonance imaging at baseline. The analysis revealed that 0.68 is an optimal Ees/Ea cut-off (area under the curve: 0.697, P < 0.001) predictive for overall survival (median follow up = 4.7 years, Ees/Ea ≥ 0.68 vs. <0.68, log-rank 8.9, P = 0.003). In patients with PH (n = 76, 68%) multivariate Cox regression demonstrated the independent prognostic value of RV-Ees/Ea in PH patients (hazard ratio 0.2, P < 0.038). Patients without PH (n = 36, 32%) and those with PH but RV-Ees/Ea ≥ 0.68 showed comparable RV-Ees/Ea ratios (0.88 vs. 0.9, P = 0.39), RV size/function, and survival. In contrast, secondary PH with RV-PA coupling ratio Ees/Ea < 0.68 corresponded extremely close to cut-off values that define RV dilatation/remodelling (RV end-diastolic volume >160 mL, RV-mass/volume-ratio ≤0.37 g/mL) and dysfunction (right ventricular ejection fraction <38%, tricuspid annular plane systolic excursion <16 mm, fractional area change <42%, and stroke-volume/end-systolic volume ratio <0.59) and is associated with a dramatically increased short and medium-term all-cause mortality. Independent predictors of prognostically unfavourable RV-PA coupling (Ees/Ea < 0.68) in secondary PH were a pre-existent dilated RV [end-diastolic volume >171 mL, odds ratio (OR) 0.96, P = 0.021], high pulsatile load (PA compliance <2.3 mL/mmHg, OR 8.6, P = 0.003), and advanced systolic left heart failure (left ventricular ejection fraction <30%, OR 1.23, P = 0.028). CONCLUSIONS: The RV-PA coupling ratio Ees/Ea predicts overall survival in PH due to HFREF and is mainly affected by pulsatile load, RV remodelling, and left ventricular dysfunction. Prognostically favourable coupling (RV-Ees/Ea ≥ 0.68) in PH was associated with preserved RV size/function and mid-term survival, comparable with HFREF without PH.


Assuntos
Insuficiência Cardíaca , Hipertensão Pulmonar , Disfunção Ventricular Direita , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Prognóstico , Estudos Prospectivos , Volume Sistólico , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/etiologia , Função Ventricular Esquerda , Função Ventricular Direita
4.
Liver Cancer ; 10(1): 10-24, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33708636

RESUMO

BACKGROUND: To date, there are inconsistent data about relationships between diffusion-weighted imaging (DWI) and tumor grading/microvascular invasion (MVI) in hepatocellular carcinoma (HCC). Our purpose was to systematize the reported results regarding the role of DWI in prediction of tumor grading/MVI in HCC. METHOD: MEDLINE library, Scopus, and Embase data bases were screened up to December 2019. Overall, 29 studies with 2,715 tumors were included into the analysis. There were 20 studies regarding DWI and tumor grading, 8 studies about DWI and MVI, and 1 study investigated DWI, tumor grading, and MVI in HCC. RESULTS: In 21 studies (1,799 tumors), mean apparent diffusion coefficient (ADC) values (ADCmean) were used for distinguishing HCCs. ADCmean of G1-3 lesions overlapped significantly. In 4 studies (461 lesions), minimum ADC (ADCmin) was used. ADCmin values in G1/2 lesions were over 0.80 × 10-3 mm2/s and in G3 tumors below 0.80 × 10-3 mm2/s. In 4 studies (241 tumors), true diffusion (D) was reported. A significant overlapping of D values between G1, G2, and G3 groups was found. ADCmean and MVI were analyzed in 9 studies (1,059 HCCs). ADCmean values of MIV+/MVI- lesions overlapped significantly. ADCmin was used in 4 studies (672 lesions). ADCmin values of MVI+ tumors were in the area under 1.00 × 10-3 mm2/s. In 3 studies (227 tumors), D was used. Also, D values of MVI+ lesions were predominantly in the area under 1.00 × 10-3 mm2/s. CONCLUSION: ADCmin reflects tumor grading, and ADCmin and D predict MVI in HCC. Therefore, these DWI parameters should be estimated for every HCC lesion for pretreatment tumor stratification. ADCmean cannot predict tumor grading/MVI in HCC.

5.
PLoS One ; 15(3): e0230024, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32196535

RESUMO

OBJECTIVE: The objective of this study is to evaluate if intensified pre-scan patient preparation (IPPP) that comprises custom-made educational material on dynamic phase imaging and supervised pre-imaging breath-hold training in addition to standard informative conversation with verbal explanation of breath-hold commands (standard pre-scan patient preparation-SPPP) might reduce the incidence of gadoxetate disodium (Gd-EOB-DTPA)-related transient severe respiratory motion (TSM) and severity of respiratory motion (RM) during dynamic phase liver MRI. MATERIAL AND METHODS: In this bi-institutional study 100 and 110 patients who received Gd-EOB-DTPA for dynamic phase liver MRI were allocated to either IPPP or SPPP at site A and B. The control group comprised 202 patients who received gadoterate meglumine (Gd-DOTA) of which each 101 patients were allocated to IPPP or SPPP at site B. RM artefacts were scored retrospectively in dynamic phase images (1: none- 5: extensive) by five and two blinded readers at site A and B, respectively, and in the hepatobiliary phase of the Gd-EOB-DTPA-enhanced scans by two blinded readers at either site. RESULTS: The incidence of TSM was 15% at site A and 22.7% at site B (p = 0.157). IPPP did not reduce the incidence of TSM in comparison to SPPP: 16.7% vs. 21.6% (p = 0.366). This finding was consistent at site A: 12% vs. 18% (p = 0.401) and site B: 20.6% vs. 25% (p = 0.590). The TSM incidence in patients with IPPP and SPPP did not differ significantly between both sites (p = 0.227; p = 0.390). IPPP did not significantly mitigate RM in comparison to SPPP in any of the Gd-EOB-DTPA-enhanced dynamic phases and the hepatobiliary phase in patients without TSM (all p≥0.072). In the Gd-DOTA control group on the other hand, IPPP significantly mitigated RM in all dynamic phases in comparison to SPPP (all p≤0.031). CONCLUSIONS: We conclude that Gd-EOB-DTPA-related TSM cannot be mitigated by education and training and that Gd-EOB-DTPA-related breath-hold difficulty does not only affect the subgroup of patients with TSM or exclusively the arterial phase as previously proposed.


Assuntos
Artefatos , Gadolínio DTPA , Compostos Heterocíclicos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Movimento , Compostos Organometálicos , Respiração , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
6.
Eur Radiol ; 30(4): 2072-2081, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31828412

RESUMO

OBJECTIVES: The aim of the study was to establish the setup and workflow for delivering focal MRI-guided high-dose-rate (HDR) brachytherapy for prostate cancer (PCA) and to assess patient comfort and safety aspects of MRI-guided single-fraction HDR. METHODS: Patients with histologically proven focal low- to intermediate-risk PCA with a single PIRADS 4/5 lesion were treated with percutaneous interstitial HDR brachytherapy in a single fraction with a minimum dose for the gross tumor volume of 20 Gy while sparing the organ at risk (OAR). Using a 3T-MRI, brachytherapy catheters were placed transgluteal in freehand technique. No antibiotic therapy or general analgesics were administered. Patient data, procedure time, patient discomfort, and complications were recorded. Quarterly PSA controls, biannual follow-up imaging, and annual re-biopsy were planned. RESULTS: So far, 9 patients were successfully treated and followed for 6 months. Mean intervention time was 34 min. Using the VAS scale, the pain reported for the intervention ranged from 2 to 3. Short-term follow-up showed no acute genitourinary or gastrointestinal toxicity so far. None of the patients displayed signs of infection. PSA levels in all patients decreased significantly. On follow up no residual PCA was detected treated region so far. PSA levels in all patients decreased significantly. On follow-up, no residual PCA was detected so far. CONCLUSIONS: MR-guided single-fraction focal HDR brachytherapy for localized PCA is feasible as well as safe for the individual patient. Catheters can be placed accurately and maximum therapeutic dose distribution can be restricted to the tumor. Countersigning the minimally invasive character of the procedure, no general anesthesia or antibiosis is necessary. KEY POINTS: • MR-guided focal HDR brachytherapy allows an accurate placement of catheters with maximum therapeutic dose distribution restricted to the tumor. • No major anesthesia or antibiosis is necessary emphasizing the minimal invasive character of the procedure. • Patients with low- and intermediate-risk prostate carcinoma in particular may benefit to halt disease progression whereas treatment-related morbidity is reduced compared with radical therapy.


Assuntos
Braquiterapia/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/radioterapia , Idoso , Biomarcadores Tumorais/metabolismo , Biópsia , Estudos de Viabilidade , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Antígeno Prostático Específico/metabolismo , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica
7.
J Contemp Brachytherapy ; 10(5): 439-445, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30479621

RESUMO

PURPOSE: To evaluate the efficacy of computed tomography (CT)- and magnetic resonance imaging (MRI)-guided interstitial high-dose-rate brachytherapy (HDR IBT = IBT) in patients with metastatic esophageal squamous cell carcinoma. MATERIAL AND METHODS: Eleven patients with 21 unresectable metastases of histologically proven esophageal squamous cell carcinoma were included in this retrospective study. Fourteen visceral and 7 lung metastases were treated with image-guided (CT or open MRI guidance) IBT using a 192Iridium source (single fraction irradiation). Clinical and imaging follow-up were performed every 3 months after treatment. Primary endpoint was local tumor control (LTC) and safety. Furthermore, we analyzed safety, progression-free survival (PFS), and overall survival (OS). RESULTS: The median diameter of the target lesions was 2.2 cm (range: 0.7-6.8 cm), treated with a median D100 of 20.1 Gy (range: 10-25 Gy). During a median follow-up of 6.3 months (range: 3-21.8 months), three patients displayed local recurrences, resulting in LTC of 85.7%. Median PFS was 3.4 months and median OS after IBT was 13.7 months. No severe adverse events (grade 3+) requiring hospitalization or invasive intervention were recorded. CONCLUSIONS: Image-guided IBT is a safe and effective treatment in patients with metastasized esophageal squamous cell carcinoma.

8.
Int J Cardiol ; 268: 156-161, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29548538

RESUMO

BACKGROUND: Right ventricular (RV) dysfunction is recognized as a cardinal prognostic marker in systolic heart failure patients. Conflicting data exist on the interaction of RV function and left ventricular (LV) reverse remodeling after cardiac resynchronization therapy (CRT). This prospective monocentric trial was set up to assess the predictive value of baseline RV function and corresponding RV-pulmonary artery (PA) coupling on LV reverse remodeling after CRT. METHODS: 110 patients with a CRT indication were prospectively enrolled. RV function and RV-PA interaction were analyzed at baseline using echocardiographic and invasive pressure-volume loop catheter approach. The primary endpoint was reverse LV remodeling (CRT-responder) defined as a reduction in LV end-systolic volume of ≥15% at 6 months. RESULTS: Responders had higher RV-PA coupling ratios (single-beat end-systolic elastance/PA elastance: Ees/Ea) at baseline, which corresponded to smaller RVs with better ejection fraction and lower afterload. After multivariate adjustment, the baseline Ees/Ea remained an independent predictor for LV response (OR 14.0 [1.5-130.8], p = 0.021). Normal coupling (Ees/Ea ≥ 1) was associated with higher responder rates (RR) (86%). Progressive uncoupling was associated with lower LV-RR (Ees/Ea ≤ 1-0.5: 57%, and Ees/Ea < 0.5: 32%, p < 0.001), corresponded with higher degrees of LV impairment and severity of mitral regurgitation, and was independently associated with an adverse outcome. CONCLUSIONS: A higher baseline RV-PA coupling, reflecting a lower degree of LV-induced pulmonary hypertension and secondary RV-dysfunction, is associated with an improved LV-reverse remodeling and is independently associated with better prognosis. The value of RV-PA ratio as potential guide for CRT patient selection warrants further investigation. Clinical Trial Registration - URL: http://www.drks.de. Unique Identifier: DRKS00011133.


Assuntos
Cateterismo Cardíaco/tendências , Terapia de Ressincronização Cardíaca/tendências , Insuficiência Cardíaca/terapia , Volume Sistólico/fisiologia , Função Ventricular Direita/fisiologia , Remodelação Ventricular/fisiologia , Idoso , Ecocardiografia/tendências , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiologia
9.
Eur Radiol ; 28(6): 2690-2699, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29344699

RESUMO

OBJECTIVE: The aim of our study was (1) to establish an in-bore targeted biopsy of suspicious prostate lesions, avoiding bowel penetration using a transgluteal approach and (2) to assess operator setup, patient comfort and safety aspects in the clinical setting for freehand real-time MR-guidance established for percutaneous procedures in an open MR-scanner. MATERIAL AND METHODS: 30 patients with suspect prostate lesions were biopsied in a cylindrical 3T-MRI system using a transgluteal approach in freehand technique. One to three biopsies were sampled using continuous dynamic imaging. Size, location and visibility of the lesion, intervention time, needle artefact size, interventional complications and histopathological diagnosis were recorded. RESULTS: All biopsies were technically successful. Nineteen patients showed evidence of prostate carcinoma. Cancer detection rate was 50 % in patients with previously negative TRUS-biopsy. The average intervention time was 26 min including a learning curve as the time was 13 min by the end of the study. No antibiotic prophylaxis was performed as none of the patients showed signs of infection. CONCLUSIONS: MR-guided targeted freehand biopsies of prostate lesions using a transgluteal approach are both technically feasible and time efficient in a standard closed-bore 3T-MR scanner as well as safe for the individual patient. KEY POINTS: • Open-bore freehand interventional principles were adapted to closed-bore systems. • Prostate MR-guided freehand biopsies were feasible in a clinical setting. • A transgluteal approach provides a short and simplified work flow. • An inoculation of the prostate with bowel flora is avoided. • The intervention time is comparable to the stereotactic approach.


Assuntos
Próstata/patologia , Neoplasias da Próstata/patologia , Idoso , Artefatos , Estudos de Viabilidade , Humanos , Biópsia Guiada por Imagem/efeitos adversos , Biópsia Guiada por Imagem/métodos , Imagem por Ressonância Magnética Intervencionista/efeitos adversos , Imagem por Ressonância Magnética Intervencionista/métodos , Masculino , Pessoa de Meia-Idade
10.
Rofo ; 189(3): 204-217, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28201839

RESUMO

This joint consensus paper of the German Roentgen Society and the German Cardiac Society provides physical and electrophysiological background information and specific recommendations for the procedural management of patients with cardiac pacemakers (PM) and implantable cardioverter defibrillators (ICD) undergoing magnetic resonance (MR) imaging. The paper outlines the responsibilities of radiologists and cardiologists regarding patient education, indications, and monitoring with modification of MR sequences and PM/ICD reprogramming strategies being discussed in particular. The aim is to optimize patient safety and to improve legal clarity in order to facilitate the access of SM/ICD patients to MR imaging. Key Points: · Conventional PM and ICD systems are no longer an absolute but rather a relative contraindication for performing an MR examination. Procedural management includes the assessment of the individual risk/benefit ratio, comprehensive patient informed consent about specific risks and "off label" use, extensive PM/ICD-related and MR-related safety precautions to reduce these risks to the greatest extent possible, as well as adequate monitoring techniques.. · MR conditional pacemaker and ICD systems have been tested and approved for MR examination under specific conditions ("in-label" use). Precise understanding of and compliance with the terms of use for the specific pacemaker system are essential for patient safety.. · The risk for an ICD patient during MR examinations is to be considered significantly higher compared to PM patients due to the higher vulnerability of the structurally damaged myocardium and the higher risk of irreversible damage to conventional ICD systems. The indication for a MR examination of an ICD patient should therefore be determined on a stricter basis and the expected risk/benefit ratio should be critically reviewed.. · This complex subject requires close collaboration between radiology and cardiology.. Citation Format · Sommer T, Bauer W, Fischbach K et al. MR Imaging in Patients with Cardiac Pacemakers and Implantable Cardioverter Defibrillators. Fortschr Röntgenstr 2017; 189: 204 - 217.


Assuntos
Desfibriladores Implantáveis/normas , Consentimento Livre e Esclarecido/normas , Imageamento por Ressonância Magnética/normas , Marca-Passo Artificial/normas , Educação de Pacientes como Assunto/normas , Guias de Prática Clínica como Assunto , Cardiologia/normas , Contraindicações , Alemanha , Humanos
11.
Cardiovasc Intervent Radiol ; 40(6): 884-893, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28160096

RESUMO

OBJECTIVE: To assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture. METHODS: A total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded. RESULTS: Visualization even of third-order non-dilated BD and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16-11:07) min. and 3:58 ± 2:35 (1:11-9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications. CONCLUSION: A hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.


Assuntos
Ductos Biliares/diagnóstico por imagem , Colestase/terapia , Drenagem/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Punções/métodos , Idoso , Idoso de 80 Anos ou mais , Cateterismo , Colestase/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
12.
Pol J Radiol ; 82: 498-505, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29662579

RESUMO

BACKGROUND: Cardiac magnetic resonance imaging (cMRI) has become the non-invasive reference standard for the evaluation of cardiac function and viability. The introduction of open, high-field, 1.0T (HFO) MR scanners offers advantages for examinations of obese, claustrophobic and paediatric patients.The aim of our study was to compare standard cMRI sequences from an HFO scanner and those from a cylindrical, 1.5T MR system. MATERIAL/METHOD: Fifteen volunteers underwent cMRI both in an open HFO and in a cylindrical MR system. The protocol consisted of cine and unenhanced tissue sequences. The signal-to-noise ratio (SNR) for each sequence and blood-myocardium contrast for the cine sequences were assessed. Image quality and artefacts were rated. The location and number of non-diagnostic segments was determined. Volunteers' tolerance to examinations in both scanners was investigated. RESULTS: SNR was significantly lower in the HFO scanner (all p<0.001). However, the contrast of the cine sequence was significantly higher in the HFO platform compared to the 1.5T MR scanner (0.685±0.41 vs. 0.611±0.54; p<0.001). Image quality was comparable for all sequences (all p>0.05). Overall, only few non-diagnostic myocardial segments were recorded: 6/960 (0.6%) by the HFO and 17/960 (1.8%) segments by the cylindrical system. The volunteers expressed a preference for the open MR system (p<0.01). CONCLUSIONS: Standard cardiac MRI sequences in an HFO platform offer a high image quality that is comparable to the quality of images acquired in a cylindrical 1.5T MR scanner. An open scanner design may potentially improve tolerance of cardiac MRI and therefore allow to examine an even broader patient spectrum.

13.
Skeletal Radiol ; 46(1): 51-58, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27771753

RESUMO

OBJECTIVE: To assess the technical success and duration of magnetic resonance imaging (MRI)-guided freehand direct shoulder arthrography (FDSA) with near real-time imaging implemented in a routine shoulder MRI examination on an open 1.0-T MRI scanner, and to assess the learning curve of residents new to this technique. METHODS: An experienced MRI interventionalist (the expert) performed 125 MRI-guided FDSA procedures, and 75 patients were treated by one of three residents without previous experience in MRI-guided FDSA. Technical success rate and duration of MRI-guided FDSA of the expert and the residents were compared. The residents' learning curves were assessed. The occurrence of extra-articular deposition and leakage of contrast media from the puncture site and the subsequent impairment of image interpretation were retrospectively analyzed. RESULTS: Overall technical success was 97.5 %. The expert needed overall fewer puncture needle readjustments and was faster at puncture needle positioning (p < 0.01). The learning curve of the residents, however, was steep. They leveled with the performance of the expert after ≈ 15 interventions. With a minimal amount of training all steps of MRI-guided FDSA can be performed in ≤10 min. CONCLUSION: Magnetic resonance-guided FDSA in an open 1.0-T MRI scanner can be performed with high technical success in a reasonably short amount of time. Only a short learning curve is necessary to achieve expert level.


Assuntos
Educação de Pós-Graduação em Medicina , Imagem por Ressonância Magnética Intervencionista/métodos , Ortopedia/educação , Radiologia/educação , Lesões do Ombro/diagnóstico por imagem , Articulação do Ombro/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Internato e Residência , Curva de Aprendizado , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
Cardiovasc Intervent Radiol ; 39(12): 1716-1721, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27435581

RESUMO

AIM: The aim of this study was to assess the rates of haemorrhagic and thrombotic complications in patients undergoing interventional tumour ablation with and without peri-interventional low-molecular-weight heparin (LMWH) thrombosis prophylaxis. METHODS: Patients presented with primary and secondary neoplastic lesions in the liver, lung, kidney, lymph nodes and other locations. A total of 781 tumour ablations (radiofrequency ablation, n = 112; interstitial brachytherapy, n = 669) were performed in 446 patients over 22 months; 260 were conducted under peri-interventional thrombosis prophylaxis with LMWH (H-group;) and 521 without this (NH-group, in 143 of these, LMWH was given post-interventionally). RESULTS: Sixty-three bleeding events occurred. There were significantly more bleedings in the H-group than in the NH-group (all interventions, 11.66 and 6.26 %, p = 0.0127; liver ablations, 12.73 and 7.1 %, p = 0.0416). The rate of bleeding events Grade ≥ III in all procedures was greater by a factor of >2.6 in the H-group than in the NH-group (4.64 and 1.73 %, p = 0.0243). In liver tumour ablations, the corresponding factor was about 3.3 (5.23 and 1.54 %, p = 0.028). In uni- and multivariate analyses including covariates, the only factor constantly and significantly associated with the rate of haemorrhage events was peri-interventional LMWH prophylaxis. Only one symptomatic lung embolism occurred in the entire cohort (NH-group). The 30- and 90-day mortalities were significantly greater in the H-group than in the NH-group. CONCLUSIONS: Peri-interventional LMWH thrombosis prophylaxis should be considered with caution. The rate of clinically relevant thrombotic events was extremely low.


Assuntos
Ablação por Cateter/efeitos adversos , Hemorragia/prevenção & controle , Heparina de Baixo Peso Molecular/uso terapêutico , Neoplasias/cirurgia , Complicações Pós-Operatórias/prevenção & controle , Tromboembolia Venosa/prevenção & controle , Idoso , Anticoagulantes/uso terapêutico , Feminino , Hemorragia/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Tromboembolia Venosa/etiologia
15.
Pol J Radiol ; 81: 54-64, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26966472

RESUMO

BACKGROUND: Irreversible electroporation (IRE) as newer ablation modality has been introduced and its clinical niche is under investigation. At present just one IRE system has been approved for clinical use and is currently commercially available (NanoKnife® system). In 2014, the International Working Group on Image-Guided Tumor Ablation updated the recommendation about standardization of terms and reporting criteria for image-guided tumor ablation. The IRE method is not covered in detail. But the non-thermal IRE method and the NanoKnife System differ fundamentally from established ablations techniques, especially thermal approaches, e.g. radio frequency ablation (RFA). MATERIAL/METHODS: As numerous publications on IRE with varying terminology exist so far - with numbers continuously increasing - standardized terms and reporting criteria of IRE are needed urgently. The use of standardized terminology may then allow for a better inter-study comparison of the methodology applied as well as results achieved. RESULTS: Thus, the main objective of this document is to supplement the updated recommendation for image-guided tumor ablation by outlining a standardized set of terminology for the IRE procedure with the NanoKnife Sytem as well as address essential clinical and technical informations that should be provided when reporting on IRE tumor ablation. CONCLUSIONS: We emphasize that the usage of all above recommended reporting criteria and terms can make IRE ablation reports comparable and provide treatment transparency to assess the current value of IRE and provide further development.

16.
Int J Comput Assist Radiol Surg ; 11(2): 169-79, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26183147

RESUMO

PURPOSE: 4D PC-MRI enables the noninvasive measurement of time-resolved, three-dimensional blood flow data that allow quantification of the hemodynamics. Stroke volumes are essential to assess the cardiac function and evolution of different cardiovascular diseases. The calculation depends on the wall position and vessel orientation, which both change during the cardiac cycle due to the heart muscle contraction and the pumped blood. However, current systems for the quantitative 4D PC-MRI data analysis neglect the dynamic character and instead employ a static 3D vessel approximation. We quantify differences between stroke volumes in the aorta obtained with and without consideration of its dynamics. METHODS: We describe a method that uses the approximating 3D segmentation to automatically initialize segmentation algorithms that require regions inside and outside the vessel for each temporal position. This enables the use of graph cuts to obtain 4D segmentations, extract vessel surfaces including centerlines for each temporal position and derive motion information. The stroke volume quantification is compared using measuring planes in static (3D) vessels, planes with fixed angulation inside dynamic vessels (this corresponds to the common 2D PC-MRI) and moving planes inside dynamic vessels. RESULTS: Seven datasets with different pathologies such as aneurysms and coarctations were evaluated in close collaboration with radiologists. Compared to the experts' manual stroke volume estimations, motion-aware quantification performs, on average, 1.57% better than calculations without motion consideration. The mean difference between stroke volumes obtained with the different methods is 7.82%. Automatically obtained 4D segmentations overlap by 85.75% with manually generated ones. CONCLUSION: Incorporating motion information in the stroke volume quantification yields slight but not statistically significant improvements. The presented method is feasible for the clinical routine, since computation times are low and essential parts run fully automatically. The 4D segmentations can be used for other algorithms as well. The simultaneous visualization and quantification may support the understanding and interpretation of cardiac blood flow.


Assuntos
Algoritmos , Aorta Torácica/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Volume Sistólico/fisiologia , Humanos , Movimento (Física)
17.
Radiother Oncol ; 115(1): 72-7, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25779722

RESUMO

BACKGROUND AND PURPOSE: To evaluate the reconstruction accuracy of brachytherapy (BT) applicators tips in vitro and in vivo in MRI-guided (192)Ir-high-dose-rate (HDR)-BT of inoperable liver tumors. MATERIALS AND METHODS: Reconstruction accuracy of plastic BT applicators, visualized by nitinol inserts, was assessed in MRI phantom measurements and in MRI (192)Ir-HDR-BT treatment planning datasets of 45 patients employing CT co-registration and vector decomposition. Conspicuity, short-term dislocation, and reconstruction errors were assessed in the clinical data. The clinical effect of applicator reconstruction accuracy was determined in follow-up MRI data. RESULTS: Applicator reconstruction accuracy was 1.6±0.5 mm in the phantom measurements. In the clinical MRI datasets applicator conspicuity was rated good/optimal in ⩾72% of cases. 16/129 applicators showed not time dependent deviation in between MRI/CT acquisition (p>0.1). Reconstruction accuracy was 5.5±2.8 mm, and the average image co-registration error was 3.1±0.9 mm. Vector decomposition revealed no preferred direction of reconstruction errors. In the follow-up data deviation of planned dose distribution and irradiation effect was 6.9±3.3 mm matching the mean co-registration error (6.5±2.5 mm; p>0.1). CONCLUSION: Applicator reconstruction accuracy in vitro conforms to AAPM TG 56 standard. Nitinol-inserts are feasible for applicator visualization and yield good conspicuity in MRI treatment planning data. No preferred direction of reconstruction errors were found in vivo.


Assuntos
Braquiterapia/métodos , Neoplasias Hepáticas/radioterapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Radioisótopos de Irídio/uso terapêutico , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos
18.
J Magn Reson Imaging ; 41(6): 1675-81, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25236353

RESUMO

PURPOSE: To determine the subjective experience of subjects undergoing 7T magnetic resonance imaging (MRI) compared to a mock scanner with no magnetic field. METHODS AND MATERIALS: In all, 44 healthy subjects were exposed to both the B0 field of a 7T whole-body MRI and a realistic mock scanner with no magnetic field. Subjects were blinded to the actual field strength and no scanning was performed. After exposure, subjects rated their experience of potential sensory perceptions. RESULTS: The most frequently observed side effect was vertigo while entering the gantry, which was reported by 38.6% (n = 17). Other frequent side effects were the appearance of phosphenes (18.2%, n = 8), thermal heat sensation (15.9%), unsteady gait after exposure (13.6%, n = 6), and dizziness (13.6%). All side effects were reported significantly more often after 7T exposure. Nine subjects (20.5%) did not report any sensory perceptions at all, ie, neither in the 7T scanner nor in the mock scanner. CONCLUSION: Light, acute, and transient sensory perceptions can occur in subjects undergoing ultrahighfield MRI, of which vertigo seems to be the most frequently reported. Possible psychological effects might contribute to the emergence of such sensory perceptions, as some subjects also reported them to appear in a realistic mock scanner with no magnetic field.


Assuntos
Campos Eletromagnéticos , Imageamento por Ressonância Magnética , Sensação/fisiologia , Vertigem/fisiopatologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...