Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur Radiol ; 24(7): 1529-36, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24792590

RESUMO

OBJECTIVE: To investigate the detectability of pulmonary nodules in chest tomosynthesis at reduced radiation dose levels. METHODS: Eighty-six patients were included in the study and were examined with tomosynthesis and computed tomography (CT). Artificial noise was added to simulate that the tomosynthesis images were acquired at dose levels corresponding to 12, 32, and 70% of the default setting effective dose (0.12 mSv). Three observers (with >20, >20 and three years of experience) read the tomosynthesis cases for presence of nodules in a free-response receiver operating characteristics (FROC) study. CT served as reference. Differences between dose levels were calculated using the jack-knife alternative FROC (JAFROC) figure of merit (FOM). RESULTS: The JAFROC FOM was 0.45, 0.54, 0.55, and 0.54 for the 12, 32, 70, and 100% dose levels, respectively. The differences in FOM between the 12% dose level and the 32, 70, and 100% dose levels were 0.087 (p = 0.006), 0.099 (p = 0.003), and 0.093 (p = 0.004), respectively. Between higher dose levels, no significant differences were found. CONCLUSIONS: A substantial reduction from the default setting dose in chest tomosynthesis may be possible. In the present study, no statistically significant difference in detectability of pulmonary nodules was found when reducing the radiation dose to 32%. KEY POINTS: • A substantial radiation dose reduction in chest tomosynthesis may be possible. • Pulmonary nodule detectability remained unchanged at 32% of the effective dose. • Tomosynthesis might be performed at the dose of a lateral chest radiograph.


Assuntos
Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Estudos Retrospectivos , Adulto Jovem
2.
Radiology ; 265(1): 273-82, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22993220

RESUMO

PURPOSE: To evaluate intra- and interobserver variability, as well as agreement for nodule size measurements on chest tomosynthesis and computed tomographic (CT) images. MATERIALS AND METHODS: The Regional Ethical Review Board approved this study, and all participants gave written informed consent. Thirty-six segmented nodules in 20 patients were included in the study. Eight observers measured the left-to-right, inferior-to-superior, and longest nodule diameters on chest tomosynthesis and CT images. Intra- and interobserver repeatability, as well as agreement between measurements on chest tomosynthesis and CT images, were assessed as recommended by Bland and Altman. RESULTS: The difference between the mean manual and the segmented diameter was -2.2 and -2.3 mm for left-to-right and -2.6 and -2.2 mm for the inferior-to-superior diameter for measurements on chest tomosynthesis and CT images, respectively. Intraobserver 95% limits of agreement (LOA) for the longest diameter ranged from a lower limit of -1.1 mm and an upper limit of 1.0 mm to -1.8 and 1.8 mm for chest tomosynthesis and from -0.6 and 0.9 mm to -3.1 and 2.2 mm for axial CT. Interobserver 95% LOA ranged from -1.3 and 1.5 mm to -2.0 and 2.1 mm for chest tomosynthesis and from -1.8 and 1.1 mm to -2.2 and 3.1 mm for axial CT. The 95% LOA concerning the mean of the observers' measurements of the longest diameter at chest tomosynthesis and axial CT were ±2.1 mm (mean measurement error, 0 mm). For the different observers, the 95% LOA between the modalities ranged from -2.2 and 1.6 mm to -3.2 and 2.8 mm. CONCLUSION: Measurements on chest tomosynthesis and CT images are comparable, because there is no evident bias between the modalities and the repeatability is similar. The LOA between measurements for the two modalities raise concern if measurements from chest tomosynthesis and CT were to be used interchangeably.


Assuntos
Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/secundário , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Torácica , Nódulo Pulmonar Solitário/secundário , Estatísticas não Paramétricas
3.
Acta Radiol ; 53(8): 874-84, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22850573

RESUMO

BACKGROUND: Simulated pathology is a valuable complement to clinical images in studies aiming at evaluating an imaging technique. In order for a study using simulated pathology to be valid, it is important that the simulated pathology in a realistic way reflect the characteristics of real pathology. PURPOSE: To perform a thorough evaluation of a nodule simulation method for chest tomosynthesis, comparing the detection rate and appearance of the artificial nodules with those of real nodules in an observer performance experiment. MATERIAL AND METHODS: A cohort consisting of 64 patients, 38 patients with a total of 129 identified pulmonary nodules and 26 patients without identified pulmonary nodules, was used in the study. Simulated nodules, matching the real clinically found pulmonary nodules by size, attenuation, and location, were created and randomly inserted into the tomosynthesis section images of the patients. Three thoracic radiologists and one radiology resident reviewed the images in an observer performance study divided into two parts. The first part included nodule detection and the second part included rating of the visual appearance of the nodules. The results were evaluated using a modified receiver-operating characteristic (ROC) analysis. RESULTS: The sensitivities for real and simulated nodules were comparable, as the area under the modified ROC curve (AUC) was close to 0.5 for all observers (range, 0.43-0.55). Even though the ratings of visual appearance for real and simulated nodules overlapped considerably, the statistical analysis revealed that the observers to were able to separate simulated nodules from real nodules (AUC values range 0.70-0.74). CONCLUSION: The simulation method can be used to create artificial lung nodules that have similar detectability as real nodules in chest tomosynthesis, although experienced thoracic radiologists may be able to distinguish them from real nodules.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Modelos Anatômicos , Intensificação de Imagem Radiográfica/métodos , Área Sob a Curva , Humanos , Tomografia Computadorizada Multidetectores , Curva ROC
4.
Acta Radiol ; 52(5): 503-12, 2011 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21498301

RESUMO

BACKGROUND: In chest tomosynthesis, low-dose projections collected over a limited angular range are used for reconstruction of an arbitrary number of section images of the chest, resulting in a moderately increased radiation dose compared to chest radiography. PURPOSE: To investigate the effects of learning with feedback on the detection of pulmonary nodules for observers with varying experience of chest tomosynthesis, to identify pitfalls regarding detection of pulmonary nodules, and present suggestions for how to avoid them, and to adapt the European quality criteria for chest radiography and computed tomography (CT) to chest tomosynthesis. MATERIAL AND METHODS: Six observers analyzed tomosynthesis cases for presence of nodules in a jackknife alternative free-response receiver-operating characteristics (JAFROC) study. CT was used as reference. The same tomosynthesis cases were analyzed before and after learning with feedback, which included a collective learning session. The difference in performance between the two readings was calculated using the JAFROC figure of merit as principal measure of detectability. RESULTS: Significant improvement in performance after learning with feedback was found only for observers inexperienced in tomosynthesis. At the collective learning session, localization of pleural and subpleural nodules or structures was identified as the main difficulty in analyzing tomosynthesis images. CONCLUSION: The results indicate that inexperienced observers can reach a high level of performance regarding nodule detection in tomosynthesis after learning with feedback and that the main problem with chest tomosynthesis is related to the limited depth resolution.


Assuntos
Competência Clínica , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Radiologia/educação , Tomografia Computadorizada por Raios X/normas , Retroalimentação , Humanos , Garantia da Qualidade dos Cuidados de Saúde , Curva ROC , Doses de Radiação , Radiografia Torácica
5.
Eur Radiol ; 20(3): 630-9, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19760236

RESUMO

AIMS: We compared the prevalence of noise-related artefacts and lesion perception on three-dimensional (3D) CT colonography (CTC) at standard and low radiation doses. METHODS: Forty-eight patients underwent CTC (64 x 0.625 mm collimation; tube rotation time 0.5 s; automatic tube current modulation: standard dose 40-160 mA, low dose 10-50 mA). Low- and standard-dose acquisitions were performed in the supine position, one after the other. The presence of artefacts (cobblestone and snow artefacts, irregularly delineated folds) and the presence of polyps were evaluated by five radiologists on 3D images at standard dose, the original low dose and a modified low dose, i.e. after manipulation of opacity on 3D. RESULTS: The mean effective dose was 3.9 +/- 1.3 mSv at standard dose and 1.03 +/- 0.4 mSv at low dose. The number of images showing cobblestone artefacts and irregularly delineated folds at original and modified low doses was significantly higher than at standard dose (P < 0.0001). Most of the artefacts on modified low-dose images were mild. No significant difference in sensitivity between the dose levels was found for polyps > or =6 mm. CONCLUSIONS: Reduction of the effective dose to 1 mSv significantly affects image quality on 3D CTC, but the perception of > or =6 mm lesions is not significantly impaired.


Assuntos
Neoplasias do Colo/diagnóstico por imagem , Colonografia Tomográfica Computadorizada/métodos , Imageamento Tridimensional/métodos , Doses de Radiação , Intensificação de Imagem Radiográfica/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Acta Radiol ; 51(1): 4-8, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19961399

RESUMO

BACKGROUND: Computed tomographic colonography (CTC) has gained increased acceptance in the last few years as a valid substitute for double-contrast barium enema (DCBE). However, implementation of new technologies is complex, since several factors may influence the process. PURPOSE: To evaluate the current situation in Sweden concerning implementation of CTC, as compared to a previous national survey in 2005. MATERIAL AND METHODS: In December 2008, a structured, self-assessed questionnaire regarding implementation and technical performance of CTC was mailed to all radiology departments in Sweden. In March 2009, departments who had not replied were contacted by e-mail or by telephone. All (100%, 119/119) departments answered the questionnaire. RESULTS: CTC is currently performed in 50/119 (42%) departments, i.e., 18 additional departments compared to 2005. Twenty-three out of 60 (38%) responding departments stated that they intend to start to perform CTC in the near future. DCBE is currently performed in 77/119 (65%) departments, 12 departments less compared to 2005. The most common reasons for non-implementation of CTC are non-availability of spiral CT scanner (41%, 26/64) and/or multidetector-row CT scanner (39%, 25/64), and lack of doctors' time (34%, 22/64). Only 3% (2/64) of departments are "awaiting further scientific documentation" on CTC, a significant reduction compared to 2005 (P=0.002). Until 2009, 59% (29/49) of CTC centers had performed more than 200 CTCs compared to 13% (4/32) of CTC centers in 2005. Intravenous contrast material is routinely administered in 86% (42/49), and carbon dioxide is used to distend the colon in 90% (44/49). Almost all radiology departments (93%, 93/100) currently believe that CTC will "absolutely" or "probably" replace barium enema in the future, while in 2005 only 56% (55/99) gave similar answers. CONCLUSION: The survey reflects a further transition process from DCBE to CTC, with attitudes of radiologists increasingly in favor of CTC, although DCBE is still performed by the majority of radiology departments. DCBE should be replaced by colonoscopy and CTC, but the transition requires both human and economic resources.


Assuntos
Colonografia Tomográfica Computadorizada/estatística & dados numéricos , Atitude do Pessoal de Saúde , Humanos , Padrões de Prática Médica/estatística & dados numéricos , Inquéritos e Questionários , Suécia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...