Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Environ Int ; 59: 1-11, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23708563

RESUMO

The expected widespread use of carbon nanotube (CNT)-composites in consumer products calls for an assessment of the possible release and exposure to workers, consumers and the environment. Release of CNTs may occur at all steps in the life cycle of products, but to date only limited information is available about release of CNTs from actual products and articles. As a starting point for exposure assessment, exploring sources and pathways of release helps to identify relevant applications and situations where the environment and especially humans may encounter releases of CNTs. It is the aim of this review to identify various potential release scenarios for CNTs used in polymers and identify the greatest likelihood of release at the various stages throughout the life-cycle of the product. The available information on release of CNTs from products and articles is reviewed in a first part. In a second part nine relevant release scenarios are described in detail: injection molding, manufacturing, sports equipment, electronics, windmill blades, fuel system components, tires, textiles, incineration, and landfills. Release from products can potentially occur by two pathways; (a) where free CNTs are released directly, or more frequently (b) where the initial release is a particle with CNTs embedded in the matrix, potentially followed by the subsequent release of CNTs from the matrix. The potential for release during manufacturing exists for all scenarios, however, this is also the situation when exposure can be best controlled. For most of the other life cycle stages and their corresponding release scenarios, potential release of CNTs can be considered to be low, but it cannot be excluded totally. Direct release to the environment is also considered to be very low for most scenarios except for the use of CNTs in tires where significant abrasion during use and release into the environment would occur. Also the possible future use of CNTs in textiles could result in consumer exposure. A possibility for significant release also exists during recycling operations when the polymers containing CNTs are handled together with other polymers and mainly occupational users would be exposed. It can be concluded that in general, significant release of CNTs from products and articles is unlikely except in manufacturing and subsequent processing, tires, recycling, and potentially in textiles. However except for high energy machining processes, most likely the resulting exposure for these scenarios will be low and to a non-pristine form of CNTs. Actual exposure studies, which quantify the amount of material released should be conducted to provide further evidence for this conclusion.


Assuntos
Vazamento de Resíduos Químicos , Exposição Ambiental , Nanotubos de Carbono/efeitos adversos , Exposição Ocupacional , Equipamentos e Provisões Elétricas/efeitos adversos , Humanos , Incineração , Nanotubos de Carbono/toxicidade , Equipamentos Esportivos/efeitos adversos , Têxteis , Instalações de Eliminação de Resíduos
2.
Part Fibre Toxicol ; 8: 22, 2011 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-21794132

RESUMO

Risk, associated with nanomaterial use, is determined by exposure and hazard potential of these materials. Both topics cannot be evaluated absolutely independently. Realistic dose concentrations should be tested based on stringent exposure assessments for the corresponding nanomaterial taking into account also the environmental and product matrix. This review focuses on current available information from peer reviewed publications related to airborne nanomaterial exposure. Two approaches to derive realistic exposure values are differentiated and independently presented; those based on workplace measurements and the others based on simulations in laboratories. An assessment of the current available workplace measurement data using a matrix, which is related to nanomaterials and work processes, shows, that data are available on the likelihood of release and possible exposure. Laboratory studies are seen as an important complementary source of information on particle release processes and hence for possible exposure. In both cases, whether workplace measurements or laboratories studies, the issue of background particles is a major problem. From this review, major areas for future activities and focal points are identified.


Assuntos
Poluentes Ocupacionais do Ar/análise , Nanopartículas/análise , Exposição Ocupacional , Poluentes Ocupacionais do Ar/toxicidade , Humanos , Nanopartículas/toxicidade , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/análise , Tamanho da Partícula , Fatores de Tempo , Local de Trabalho/normas
3.
Part Fibre Toxicol ; 3: 11, 2006 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-16907977

RESUMO

During the last few years, research on toxicologically relevant properties of engineered nanoparticles has increased tremendously. A number of international research projects and additional activities are ongoing in the EU and the US, nourishing the expectation that more relevant technical and toxicological data will be published. Their widespread use allows for potential exposure to engineered nanoparticles during the whole lifecycle of a variety of products. When looking at possible exposure routes for manufactured Nanoparticles, inhalation, dermal and oral exposure are the most obvious, depending on the type of product in which Nanoparticles are used. This review shows that (1) Nanoparticles can deposit in the respiratory tract after inhalation. For a number of nanoparticles, oxidative stress-related inflammatory reactions have been observed. Tumour-related effects have only been observed in rats, and might be related to overload conditions. There are also a few reports that indicate uptake of nanoparticles in the brain via the olfactory epithelium. Nanoparticle translocation into the systemic circulation may occur after inhalation but conflicting evidence is present on the extent of translocation. These findings urge the need for additional studies to further elucidate these findings and to characterize the physiological impact. (2) There is currently little evidence from skin penetration studies that dermal applications of metal oxide nanoparticles used in sunscreens lead to systemic exposure. However, the question has been raised whether the usual testing with healthy, intact skin will be sufficient. (3) Uptake of nanoparticles in the gastrointestinal tract after oral uptake is a known phenomenon, of which use is intentionally made in the design of food and pharmacological components. Finally, this review indicates that only few specific nanoparticles have been investigated in a limited number of test systems and extrapolation of this data to other materials is not possible. Air pollution studies have generated indirect evidence for the role of combustion derived nanoparticles (CDNP) in driving adverse health effects in susceptible groups. Experimental studies with some bulk nanoparticles (carbon black, titanium dioxide, iron oxides) that have been used for decades suggest various adverse effects. However, engineered nanomaterials with new chemical and physical properties are being produced constantly and the toxicity of these is unknown. Therefore, despite the existing database on nanoparticles, no blanket statements about human toxicity can be given at this time. In addition, limited ecotoxicological data for nanomaterials precludes a systematic assessment of the impact of Nanoparticles on ecosystems.

4.
J Environ Monit ; 7(9): 877-82, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16121267

RESUMO

A Gas Particle Partitioner (GPP) that allows highly efficient separation of gas and particles with no effect on the thermodynamic conditions and substantially no change of the gas composition has been developed. The GPP is a coaxial arrangement with inner and outer electrodes and utilizes a corona discharge to electrically charge the particles and a strong electric field to remove them from the sample flow. Several measures were taken to avoid an influence of the corona discharge on the gas composition. The GPP can be applied for various applications. This paper focuses on the use of the GPP as a pre-filter for gas analyzers, where zero pressure drop and a minimization of the influence of the corona discharge on the gas composition are the main objective. Due to its design, the GPP introduces no changes to the thermodynamic conditions. However, corona discharge is known to produce significant amounts of ozone and oxides of nitrogen. The effect of the corona on the gas composition of the sample flow was determined under various conditions. The gas concentrations strongly depended on several aspects, such as material and diameter of the corona wire and polarity of the corona voltage. Due to the measures taken to minimize an effect on the gas composition, the concentrations of these gases could effectively be reduced. Along with the maximum gas-particle separation efficiency of near 100%, the additional O3 concentration was 42 ppbV and the additional NO2 concentration 15 ppbV. If an efficiency of 95% is acceptable, the added concentrations can be as low as 2.5 ppbV (O3) and 0.5 ppbV (NO2), respectively.


Assuntos
Poluentes Atmosféricos/análise , Monitoramento Ambiental/métodos , Gases/química , Eletroquímica , Monitoramento Ambiental/instrumentação , Filtração , Dióxido de Nitrogênio/análise , Dióxido de Nitrogênio/química , Ozônio/análise , Ozônio/química , Tamanho da Partícula , Termodinâmica
5.
J Colloid Interface Sci ; 255(2): 332-40, 2002 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-12505081

RESUMO

A new method has been developed which allows determination of the coagulation coefficient of two oppositely charged particles experimentally. For this purpose, quasi-monodisperse particles of different sizes and morphology were used to study the influence of different parameters on the coagulation coefficient. A good agreement between experimental results and the classic Fuchs' theory was obtained when including a method accounting for particle nonsphericity. In experiments with polydisperse bipolarly charged aerosols, no principal differences to uncharged aerosols were found when a dimensionless representation was used. Changes in particle number concentration and geometric mean diameter can be described by simple empirical expressions.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA