Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Int J Clin Pharm ; 45(5): 1286-1292, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37755642

RESUMO

A large proportion of the world's disease burden is attributable to mental illnesses. Although effective interventions are available, many patients still have limited access to evidence-based treatments. Aside from access, treatment gaps, including inappropriate medication selection and monitoring, are also routinely recognised. Mental health clinical pharmacists can help address these gaps and enable patients to receive optimised pharmaceutical care, particularly appropriate medication selection and monitoring. The European Society of Clinical Pharmacy (ESCP) Special Interest Group on Mental Health was established to improve standardised service provision in mental health settings across Europe. The Special Interest Group identified significant barriers (predominantly associated with reimbursement and position within the multidisciplinary team) to effective pharmaceutical care amongst those with mental illnesses. This commentary presents recommendations to address these gaps through improved mental health clinical pharmacy service provision.


Assuntos
Serviço de Farmácia Hospitalar , Farmácia , Humanos , Saúde Mental , Opinião Pública , Europa (Continente)/epidemiologia , Farmacêuticos/psicologia
2.
Rev Sci Instrum ; 93(11): 113549, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461471

RESUMO

A new Doppler backscattering (DBS) system has been installed and tested on the MAST-U spherical tokamak. It utilizes eight simultaneous fixed frequency probe beams (32.5, 35, 37.5, 40, 42.5, 45, 47.5, and 50 GHz). These frequencies provide a range of radial positions from the edge plasma to the core depending on plasma conditions. The system utilizes a combination of novel features to provide remote control of the probed density wavenumber, the launched polarization (X vs O-mode), and the angle of the launched DBS to match the magnetic field pitch angle. The range of accessible density turbulence wavenumbers (kθ) is reasonably large with normalized wavenumbers kθρs ranging from ≤0.5 to 9 (ion sound gyroradius ρs = 1 cm). This wavenumber range is relevant to a variety of instabilities believed to be important in establishing plasma transport (e.g., ion temperature gradient, trapped electron, electron temperature gradient, micro-tearing, kinetic ballooning modes). The system is specifically designed to address the requirement of density fluctuation wavevector alignment which can significantly reduce the SNR if not accounted for.

3.
Rev Sci Instrum ; 89(10): 10I110, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399869

RESUMO

The Neutron Camera Upgrade (NCU) is a neutron flux monitor consisting of six lines of sight (LoSs) under installation on Mega Ampere Spherical Tokamak (MAST) Upgrade. The NCU is expected to contribute to the study of the confinement of fast ions and on the efficiency of non-inductive current drive in the presence of on-axis and off-axis neutral beam injection by measuring the neutron emissivity profile along the equatorial plane. This paper discusses the NCU main design criteria, the engineering and interfacing issues, and the solutions adopted. In addition, the results from the characterization and performance studies of the neutron detectors using standard γ-rays sources and a 252Cf source are discussed. The proposed design has a time resolution of 1 ms with a statistical uncertainty of less than 10% for all MAST Upgrade scenarios with a spatial resolution of 10 cm: higher spatial resolution is possible by moving the LoSs in-between plasma discharges. The energy resolution of the neutron detector is better than 10% for a light output of 0.8 MeVee, and the measured pulse shape discrimination is satisfactory.

4.
Phys Rev Lett ; 115(21): 215004, 2015 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-26636857

RESUMO

Electron and ion heating characteristics during merging reconnection start-up on the MAST spherical tokamak have been revealed in detail using a 130 channel yttrium aluminum garnet (YAG) and a 300 channel Ruby-Thomson scattering system and a new 32 chord ion Doppler tomography diagnostic. Detailed 2D profile measurements of electron and ion temperature together with electron density have been achieved for the first time and it is found that electron temperature forms a highly localized hot spot at the X point and ion temperature globally increases downstream. For the push merging experiment when the guide field is more than 3 times the reconnecting field, a thick layer of a closed flux surface form by the reconnected field sustains the temperature profile for longer than the electron and ion energy relaxation time ~4-10 ms, both characteristic profiles finally forming a triple peak structure at the X point and downstream. An increase in the toroidal guide field results in a more peaked electron temperature profile at the X point, and also produces higher ion temperatures at this point, but the ion temperature profile in the downstream region is unaffected.

5.
Rev Sci Instrum ; 81(10): 10D315, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21033841

RESUMO

A prototype neutron camera has been developed and installed at MAST as part of a feasibility study for a multichord neutron camera system with the aim to measure the spatial and time resolved 2.45 MeV neutron emissivity profile. Liquid scintillators coupled to a fast digitizer are used for neutron/gamma ray digital pulse shape discrimination. The preliminary results obtained clearly show the capability of this diagnostic to measure neutron emissivity profiles with sufficient time resolution to study the effect of fast ion loss and redistribution due to magnetohydrodynamic activity. A minimum time resolution of 2 ms has been achieved with a modest 1.5 MW of neutral beam injection heating with a measured neutron count rate of a few 100 kHz.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...