1.
Artigo em Inglês | MEDLINE | ID: mdl-31114677

RESUMO

Background: Education is a cornerstone strategy to prevent health-associated infections. Trainings benefit from being interactive, simulation-based, team-orientated, and early in professional socialization. We conceived an innovative inter-professional peer-teaching module with operating room technician trainees (ORTT) teaching infection prevention behavior in the operating room (OR) to medical students (MDS). Methods: ORTT delivered a 2-h teaching module to small groups of MDS in a simulated OR setting with 4 posts: 'entering OR'; 'surgical hand disinfection'; 'dressing up for surgery and preparing a surgical field', 'debriefing'. MDS and ORTT evaluated module features and teaching quality through 2 specific questionnaires. Structured field notes by education specialist observers were analyzed thematically. Results: On Likert scales from - 2 to + 2, mean overall satisfaction was + 1.91 (±0.3) for MDS and + 1.66 (±0.6 SD) for ORTT while teaching quality was rated + 1.89 (±0.3) by MDS and self-rated with + 1.34 (±0.5) by ORTT. Students and observers highlighted that the training fostered mutual understanding and provided insight into the corresponding profession. Conclusions: Undergraduate inter-professional teaching among ORTT and MDS in infection prevention and control proved feasible with high educational quality. Inducing early mutual understanding between professional groups might improve professional collaboration and patient safety.


Assuntos
Currículo , Educação Médica/métodos , Controle de Infecções/métodos , Auxiliares de Cirurgia , Treinamento por Simulação , Estudantes de Medicina , Adulto , Feminino , Humanos , Infecções , Masculino
2.
Int J Comput Assist Radiol Surg ; 12(8): 1307-1317, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28634788

RESUMO

PURPOSE: 4D ultrasound imaging of the fetal heart relies on reconstructions from B-mode images. In the presence of fetal motion, current approaches suffer from artifacts, which are unrecoverable for single sweeps. METHODS: We propose to use many sweeps and exploit the resulting redundancy to automatically recover from motion by reconstructing a 4D image which is consistent in phase, space, and time. An interactive visualization framework to view animated ultrasound slices from 4D reconstructions on arbitrary planes was developed using a magnetically tracked mock probe. RESULTS: We first quantified the performance of 10 4D reconstruction formulations on simulated data. Reconstructions of 14 in vivo sequences by a baseline, the current state-of-the-art, and the proposed approach were then visually ranked with respect to temporal quality on orthogonal views. Rankings from 5 observers showed that the proposed 4D reconstruction approach significantly improves temporal image quality in comparison with the baseline. The 4D reconstructions of the baseline and the proposed methods were then inspected interactively for accessibility to clinically important views and rated for their clinical usefulness by an ultrasound specialist in obstetrics and gynecology. The reconstructions by the proposed method were rated as 'very useful' in 71% and were statistically significantly more useful than the baseline reconstructions. CONCLUSIONS: Multi-sweep fetal heart ultrasound acquisitions in combination with consistent 4D image reconstruction improves quality as well as clinical usefulness of the resulting 4D images in the presence of fetal motion.


Assuntos
Ecocardiografia/métodos , Coração Fetal/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Feminino , Coração Fetal/fisiologia , Humanos , Processamento de Imagem Assistida por Computador , Movimento (Física) , Imagens de Fantasmas , Gravidez
3.
Phys Med Biol ; 59(24): 7865-87, 2014 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-25426660

RESUMO

Many applications in medical imaging include image registration for matching of images from the same or different modalities. In the case of full data sampling, the respective reconstructed images are usually of such a good image quality that standard deformable volume-to-volume (3D-3D) registration approaches can be applied. But research in temporal-correlated image reconstruction and dose reductions increases the number of cases where rawdata are available from only few projection angles. Here, deteriorated image quality leads to non-acceptable deformable volume-to-volume registration results. Therefore a registration approach is required that is robust against a decreasing number of projections defining the target position. We propose a deformable volume-to-rawdata (3D-2D) registration method that aims at finding a displacement vector field maximizing the alignment of a CT volume and the acquired rawdata based on the sum of squared differences in rawdata domain. The registration is constrained by a regularization term in accordance with a fluid-based diffusion. Both cost function components, the rawdata fidelity and the regularization term, are optimized in an alternating manner. The matching criterion is optimized by a conjugate gradient descent for nonlinear functions, while the regularization is realized by convolution of the vector fields with Gaussian kernels. We validate the proposed method and compare it to the demons algorithm, a well-known 3D-3D registration method. The comparison is done for a range of 4-60 target projections using datasets from low dose tomographic fluoroscopy as an application example. The results show a high correlation to the ground truth target position without introducing artifacts even in the case of very few projections. In particular the matching in the rawdata domain is improved compared to the 3D-3D registration for the investigated range. The proposed volume-to-rawdata registration increases the robustness regarding sparse rawdata and provides more stable results than volume-to-volume approaches. By applying the proposed registration approach to low dose tomographic fluoroscopy it is possible to improve the temporal resolution and thus to increase the robustness of low dose tomographic fluoroscopy.


Assuntos
Algoritmos , Fluoroscopia/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Animais , Artefatos , Suínos
4.
Med Phys ; 40(10): 101909, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24089911

RESUMO

PURPOSE: Today's standard imaging technique in interventional radiology is the single- or biplane x-ray fluoroscopy which delivers 2D projection images as a function of time (2D+T). This state-of-the-art technology, however, suffers from its projective nature and is limited by the superposition of the patient's anatomy. Temporally resolved tomographic volumes (3D+T) would significantly improve the visualization of complex structures. A continuous tomographic data acquisition, if carried out with today's technology, would yield an excessive patient dose. Recently the authors proposed a method that enables tomographic fluoroscopy at the same dose level as projective fluoroscopy which means that if scanning time of an intervention guided by projective fluoroscopy is the same as that of an intervention guided by tomographic fluoroscopy, almost the same dose is administered to the patient. The purpose of this work is to extend authors' previous work and allow for patient motion during the intervention. METHODS: The authors propose the running prior technique for adaptation of a prior image. This adaptation is realized by a combination of registration and projection replacement. In a first step the prior is deformed to the current position via affine and deformable registration. Then the information from outdated projections is replaced by newly acquired projections using forward and backprojection steps. The thus adapted volume is the running prior. The proposed method is validated by simulated as well as measured data. To investigate motion during intervention a moving head phantom was simulated. Real in vivo data of a pig are acquired by a prototype CT system consisting of a flat detector and a continuously rotating clinical gantry. RESULTS: With the running prior technique it is possible to correct for motion without additional dose. For an application in intervention guidance both steps of the running prior technique, registration and replacement, are necessary. Reconstructed volumes based on the running prior show high image quality without introducing new artifacts and the interventional materials are displayed at the correct position. CONCLUSIONS: The running prior improves the robustness of low dose 3D+T intervention guidance toward intended or unintended patient motion.


Assuntos
Fluoroscopia/métodos , Imageamento Tridimensional/métodos , Doses de Radiação , Radiologia/métodos , Tomografia/métodos , Animais , Artérias Carótidas/diagnóstico por imagem , Movimento , Imagens de Fantasmas , Suínos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...