1.
Diagnostics (Basel) ; 14(15)2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-39125571

RESUMO

PURPOSE: This study assesses the efficacy and safety of self-expandable (SE) versus balloon-expandable (BE) stent grafts for managing visceral artery aneurysms (VAAs), focusing on procedural success and complication rates. MATERIALS AND METHODS: We conducted a retrospective analysis of VAA patients treated at our institution from April 2006 to September 2021. The study reviewed patient demographics, aneurysm characteristics, treatment details, and outcomes, including endoleaks. RESULTS: Among the 23 patients analyzed, splenic artery aneurysms represented 44% of cases. Fifteen patients were treated with balloon-expandable stent grafts (BE SGs), and eight patients were treated with self-expandable stent grafts (SE SGs). For saccular aneurysms, the average neck size was 10.10 ± 8.70 mm in the BE group versus 18.50 ± 3.40 mm in the SE group (p = 0.23), with an average sac size of 20.10 ± 18.9 mm in the BE group versus 15.60 ± 12.7 mm in the SE group (p = 0.16). The average sac-to-neck ratio was 1.69 ± 2.23 in the BE group versus 1.38 ± 0.33 in the SE group (p = 0.63). The BE group exhibited a significantly higher endoleak rate (60%) compared to the SE group (12.5%; p = 0.03). CONCLUSIONS: While further investigation is needed to fully assess the outcomes of stent graft treatment for VAAs, initial data show a significantly higher endoleak rate with BE SGs compared to SE SGs. The SE SGs may offer better outcomes due to their superior ability to conform to tortuous and mobile visceral arteries.

2.
JAMA Netw Open ; 5(12): e2248159, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36542378

RESUMO

Importance: Despite historically high rates of use, most inferior vena cava (IVC) filters are not retrieved. The US Food and Drug Administration safety communications recommended retrieval when the IVC filter is no longer indicated out of concern for filter-related complications. However, failure rates are high when using standard techniques for retrieval of long-dwelling filters, and until recently, there have been no devices approved for retrieval of embedded IVC filters. Objective: To evaluate the safety and success of excimer laser sheath-assisted retrieval of embedded IVC filters. Design, Setting, and Participants: A retrospective, multicenter, clinical cohort study of excimer laser sheath-assisted IVC filter retrievals from 7 US sites was conducted between March 1, 2012, and February 28, 2021, among 265 patients who underwent IVC filter retrieval using the laser. Patients were substratified between a high-volume single center and a multicenter data set. A blinded physician committee adjudicated reported complications and their association with use of the laser. Exposures: Retrieval of IVC filters using excimer laser sheath. Main Outcomes and Measures: The primary safety end point was device-related major complication rate (Society of Interventional Radiology categories C to F, which included any adverse event associated with morbidity or disability that increases the level of care, results in hospital admission, or substantially lengthens the hospital stay). The primary success end point was technical success of IVC filter retrieval. The primary end points were compared with literature-derived, meta-analysis-suggested target performance goals. Results: The single-center experience included 139 participants (mean [SD] age, 52 [16] years; 78 female participants [56.1%]), and the multicenter experience included 126 participants (mean [SD] age, 52 [16] years; 75 female participants [59.5%]). The device-related major complication rate was 2.9% (4 of 139; 95% CI, 0.8%-7.2%; P = .001) for the single-center experience and 4.0% (5 of 126; 95% CI, 1.3%-9.0%; P = .01) for the multicenter experience, both of which were significantly lower than the primary safety performance goal (10%). No major complications were considered to be definitively associated with use of the laser. The technical success rate was 95.7% (133 of 139; 95% CI, 90.8%-98.4%; P = .007) for the single-center experience and 95.2% (120 of 126; 95% CI, 89.9%-98.2%; P = .02) for the multicenter experience, both of which were significantly higher than the primary performance goal (89.4%). Conclusions and Relevance: This cohort study demonstrated high technical success and low complication rates of excimer laser sheath-assisted retrieval of embedded IVC filters in centers with variable case volume and experience, which suggests a wide applicability of the technique with proper training. The excimer laser sheath offers physicians a valuable tool for retrieval of challenging embedded IVC filters.


Assuntos
Lasers de Excimer , Filtros de Veia Cava , Humanos , Feminino , Pessoa de Meia-Idade , Lasers de Excimer/uso terapêutico , Estudos de Coortes , Estudos Retrospectivos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Estudos Multicêntricos como Assunto
4.
Pediatr Radiol ; 46(2): 246-54, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26589304

RESUMO

OBJECTIVE: To assess the value and complementary roles of fetal MRI and US for characterization and diagnosis of suprarenal masses. MATERIALS AND METHODS: We conducted a multi-institutional retrospective database search for prenatally diagnosed suprarenal masses between 1999 and 2012 and evaluated the roles of prenatal US and fetal MRI for characterization and diagnosis, using postnatal diagnosis or surgical pathology as the reference standard. Prenatal US and fetal MRI were assessed for unique findings of each modality. RESULTS: The database yielded 25 fetuses (gestational age 20-37 weeks) with suprarenal masses. Twenty-one fetuses had prenatal US, 22 had MRI, 17 had both. Postnatal diagnoses included nine subdiaphragmatic extralobar sequestrations, seven adrenal hemorrhages, five neuroblastomas (four metastatic), two lymphatic malformations, one duplex kidney with upper pole cystic dysplasia, and one adrenal hyperplasia. Ultrasound was concordant with MRI for diagnoses in 12/17 (70.6%) cases. Discordant diagnoses between US and MRI included three neuroblastomas and two adrenal hemorrhages. In the three neuroblastomas US was equivocal and MRI was definitive for neuroblastoma, demonstrating heterogeneous, intermediate-signal solid masses and liver metastases. In the two cases of adrenal hemorrhage US was equivocal and MRI was definitive with signal characteristics of hemorrhage. In 2/4 neuroblastomas, Doppler US demonstrated a systemic artery suggesting extralobar sequestration; however MRI signal characteristics correctly diagnosed neuroblastoma. All cases of extralobar sequestration were correctly diagnosed by US and MRI. CONCLUSION: US and MRI both accurately detect suprarenal masses. MRI complements US in equivocal diagnoses and detects additional findings such as liver metastases in neuroblastoma.


Assuntos
Doenças das Glândulas Suprarrenais/diagnóstico , Glândulas Suprarrenais/anormalidades , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Ultrassonografia Pré-Natal/métodos , Doenças das Glândulas Suprarrenais/embriologia , Glândulas Suprarrenais/diagnóstico por imagem , Glândulas Suprarrenais/patologia , California , Feminino , Humanos , Masculino , Pennsylvania , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS