Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Proc Natl Acad Sci U S A ; 120(6): e2217828120, 2023 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-36716364

RESUMO

Thermal sensations contribute to our ability to perceive and explore the physical world. Reproducing these sensations in a spatiotemporally programmable manner through wireless computer control could enhance virtual experiences beyond those supported by video, audio and, increasingly, haptic inputs. Flexible, lightweight and thin devices that deliver patterns of thermal stimulation across large areas of the skin at any location of the body are of great interest in this context. Applications range from those in gaming and remote socioemotional communications, to medical therapies and physical rehabilitation. Here, we present a set of ideas that form the foundations of a skin-integrated technology for power-efficient generation of thermal sensations across the skin, with real-time, closed-loop control. The systems exploit passive cooling mechanisms, actively switchable thermal barrier interfaces, thin resistive heaters and flexible electronics configured in a pixelated layout with wireless interfaces to portable devices, the internet and cloud data infrastructure. Systematic experimental studies and simulation results explore the essential mechanisms and guide the selection of optimized choices in design. Demonstration examples with human subjects feature active thermoregulation, virtual social interactions, and sensory expansion.


Assuntos
Pele , Realidade Virtual , Humanos , Eletrônica , Sensação Térmica , Comunicação
2.
Proc Natl Acad Sci U S A ; 119(23): e2117764119, 2022 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-35653567

RESUMO

Electrical nerve stimulation serves an expanding list of clinical applications, but it faces persistent challenges in selectively activating bundled nerve fibers. In this study, we investigated electrochemical modulation with an ion-selective membrane (ISM) and whether it, used together with electrical stimulation, may provide an approach for selective control of peripheral nerves. Guided by theoretical transport modeling and direct concentration measurements, we developed an implantable, multimodal ISM cuff capable of simultaneous electrical stimulation and focused Ca2+ depletion. Acutely implanting it on the sciatic nerve of a rat in vivo, we demonstrated that Ca2+ depletion could increase the sensitivity of the nerve to electrical stimulation. Furthermore, we found evidence that the effect of ion modulation would selectively influence functional components of the nerve, allowing selective activation by electrical current. Our results raise possibilities for improving functional selectivity of new and existing bioelectronic therapies, such as vagus nerve stimulation.


Assuntos
Terapia por Estimulação Elétrica , Tecido Nervoso , Nervo Isquiático , Animais , Estimulação Elétrica , Fibras Nervosas , Ratos , Nervo Isquiático/fisiologia
3.
Water Res ; 201: 117351, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-34161873

RESUMO

In electromembrane processes such as electrodialysis (ED) and ion concentration polarization (ICP), the diffusion layers on both diluate and concentrate sides influence permselectivity of the ion-exchange membrane and current utilization. The diffusion layer in the diluate stream, due to lower salinity and higher resistivity, has been regarded as the primary source of energy loss. In contrast, very few studies have focused on the diffusion layer in the concentrate stream. In this paper, we evaluate the influence of hydrodynamic convective flow on the development of diffusion layers on both concentrate and diluate sides, specifically in the ICP desalination process. Interestingly, the higher convective flow in the concentrate side was shown to drastically improve the current utilization drop in high operating current, which has been a recurring challenge in electromembrane processes. We attribute this to the prevention of co-ion leakage into the membrane, confirmed by both experimentation and numerical modeling. This new insight has a clear design implication for optimizing electromembrane processes for higher energy efficiency.


Assuntos
Salinidade , Troca Iônica
4.
Front Neurosci ; 15: 628778, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33664647

RESUMO

For many peripheral neuro-modulation applications, the cuff electrode has become a preferred technology for delivering electrical current into targeted volumes of tissue. While basic cuffs with low spatial selectivity, having longitudinally arranged contacts, can be produced from relatively straightforward processes, the fabrication of more complex electrode configurations typically requires iterative design and clean-room fabrication with skilled technicians. Although facile methods for fabricating cuff electrodes exist, their inconsistent products have limited their adoption for rapid manufacturing. In this article, we report a fast, low-cost fabrication process for patterning of electrode contacts in an implantable peripheral nerve cuff. Using a laser cutter as we have prescribed, the designer can render precise contact geometries that are consistent between batches. This method is enabled by the use of silicone/carbon black (CB) composite electrodes, which integrate with the patterned surface of its substrate-tubular silicone insulation. The size and features of its products can be adapted to fit a wide range of nerve diameters and applications. In this study, we specifically documented the manufacturing and evaluation of circumpolar cuffs with radial arrays of three contacts for acute implantation on the rat sciatic nerve. As part of this method, we also detail protocols for verification-electrochemical characterization-and validation-electrophysiological evaluation-of implantable cuff electrodes. Applied to our circumpolar cuff electrode, we report favorable electrical characteristics. In addition, we report that it reproduces expected electrophysiological behaviors described in prior literature. No specialized equipment or fabrication experience was required in our production, and we encountered negligible costs relative to commercially available solutions. Since, as we demonstrate, this process generates consistent and precise electrode geometries, we propose that it has strong merits for use in rapid manufacturing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...