Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Phys Rev Lett ; 130(17): 173201, 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37172237

RESUMO

We demonstrate that x-ray fluorescence emission, which cannot maintain a stationary interference pattern, can be used to obtain images of structures by recording photon-photon correlations in the manner of the stellar intensity interferometry of Hanbury Brown and Twiss. This is achieved utilizing femtosecond-duration pulses of a hard x-ray free-electron laser to generate the emission in exposures comparable to the coherence time of the fluorescence. Iterative phasing of the photon correlation map generated a model-free real-space image of the structure of the emitters. Since fluorescence can dominate coherent scattering, this may enable imaging uncrystallised macromolecules.

2.
Light Sci Appl ; 12(1): 130, 2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37248250

RESUMO

The highest resolution of images of soft matter and biological materials is ultimately limited by modification of the structure, induced by the necessarily high energy of short-wavelength radiation. Imaging the inelastically scattered X-rays at a photon energy of 60 keV (0.02 nm wavelength) offers greater signal per energy transferred to the sample than coherent-scattering techniques such as phase-contrast microscopy and projection holography. We present images of dried, unstained, and unfixed biological objects obtained by scanning Compton X-ray microscopy, at a resolution of about 70 nm. This microscope was realised using novel wedged multilayer Laue lenses that were fabricated to sub-ångström precision, a new wavefront measurement scheme for hard X rays, and efficient pixel-array detectors. The doses required to form these images were as little as 0.02% of the tolerable dose and 0.05% of that needed for phase-contrast imaging at similar resolution using 17 keV photon energy. The images obtained provide a quantitative map of the projected mass density in the sample, as confirmed by imaging a silicon wedge. Based on these results, we find that it should be possible to obtain radiation damage-free images of biological samples at a resolution below 10 nm.

3.
IUCrJ ; 9(Pt 6): 778-791, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36381150

RESUMO

Serial crystallography at conventional synchrotron light sources (SSX) offers the possibility to routinely collect data at room temperature using micrometre-sized crystals of biological macromolecules. However, SSX data collection is not yet as routine and currently takes significantly longer than the standard rotation series cryo-crystallography. Thus, its use for high-throughput approaches, such as fragment-based drug screening, where the possibility to measure at physio-logical temperatures would be a great benefit, is impaired. On the way to high-throughput SSX using a conveyor belt based sample delivery system - the CFEL TapeDrive - with three different proteins of biological relevance (Klebsiella pneumoniae CTX-M-14 ß-lactamase, Nectria haematococca xylanase GH11 and Aspergillus flavus urate oxidase), it is shown here that complete datasets can be collected in less than a minute and only minimal amounts of sample are required.

4.
Opt Express ; 30(14): 25450-25473, 2022 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-36237075

RESUMO

In recent years, X-ray speckle tracking techniques have emerged as viable tools for wavefront metrology and sample imaging applications, and have been actively developed for use at synchrotron light sources. Speckle techniques can recover an image free of aberrations and can be used to measure wavefronts with a high angular sensitivity. Since they are compatible with low-coherence sources they can be also used with laboratory X-ray sources. A new implementation of the ptychographic X-ray speckle tracking method, suitable for the metrology of highly divergent wavefields, such as those created by multilayer Laue lenses, is presented here. This new program incorporates machine learning techniques such as Huber and non-parametric regression and enables robust and quick wavefield measurements and data evaluation even for low brilliance X-ray beams, and the imaging of low-contrast samples. To realize this, a software suite was written in Python 3, with a C back-end capable of concurrent calculations for high performance. It is accessible as a Python module and is available as source code under Version 3 or later of the GNU General Public License.

5.
Rev Sci Instrum ; 93(7): 073704, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35922318

RESUMO

Improvements in x-ray optics critically depend on the measurement of their optical performance. The knowledge of wavefront aberrations, for example, can be used to improve the fabrication of optical elements or to design phase correctors to compensate for these errors. At present, the characterization of such optics is made using intense x-ray sources, such as synchrotrons. However, the limited access to these facilities can substantially slow down the development process. Improvements in the brightness of lab-based x-ray micro-sources in combination with the development of new metrology methods, particularly ptychographic x-ray speckle tracking, enable characterization of x-ray optics in the lab with a precision and sensitivity not possible before. Here, we present a laboratory setup that utilizes a commercially available x-ray source and can be used to characterize different types of x-ray optics. The setup is used in our laboratory on a routine basis to characterize multilayer Laue lenses of high numerical aperture and other optical elements. This typically includes measurements of the wavefront distortions, optimum operating photon energy, and focal length of the lens. To check the sensitivity and accuracy of this laboratory setup, we compared the results to those obtained at the synchrotron and saw no significant difference. To illustrate the feedback of measurements on performance, we demonstrated the correction of the phase errors of a particular multilayer Laue lens using a 3D printed compound refractive phase plate.

6.
Science ; 372(6542): 642-646, 2021 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-33811162

RESUMO

The coronavirus disease (COVID-19) caused by SARS-CoV-2 is creating tremendous human suffering. To date, no effective drug is available to directly treat the disease. In a search for a drug against COVID-19, we have performed a high-throughput x-ray crystallographic screen of two repurposing drug libraries against the SARS-CoV-2 main protease (Mpro), which is essential for viral replication. In contrast to commonly applied x-ray fragment screening experiments with molecules of low complexity, our screen tested already-approved drugs and drugs in clinical trials. From the three-dimensional protein structures, we identified 37 compounds that bind to Mpro In subsequent cell-based viral reduction assays, one peptidomimetic and six nonpeptidic compounds showed antiviral activity at nontoxic concentrations. We identified two allosteric binding sites representing attractive targets for drug development against SARS-CoV-2.


Assuntos
Sítio Alostérico , Antivirais/química , Domínio Catalítico , Proteases 3C de Coronavírus/antagonistas & inibidores , Proteases 3C de Coronavírus/química , Desenvolvimento de Medicamentos , Inibidores de Proteases/química , SARS-CoV-2/enzimologia , Animais , Antivirais/farmacologia , Chlorocebus aethiops , Cristalografia por Raios X , Avaliação Pré-Clínica de Medicamentos , Inibidores de Proteases/farmacologia , SARS-CoV-2/efeitos dos fármacos , Células Vero , Replicação Viral/efeitos dos fármacos
7.
Nat Commun ; 11(1): 4511, 2020 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-32908128

RESUMO

Serial femtosecond crystallography (SFX) with X-ray free electron lasers (XFELs) allows structure determination of membrane proteins and time-resolved crystallography. Common liquid sample delivery continuously jets the protein crystal suspension into the path of the XFEL, wasting a vast amount of sample due to the pulsed nature of all current XFEL sources. The European XFEL (EuXFEL) delivers femtosecond (fs) X-ray pulses in trains spaced 100 ms apart whereas pulses within trains are currently separated by 889 ns. Therefore, continuous sample delivery via fast jets wastes >99% of sample. Here, we introduce a microfluidic device delivering crystal laden droplets segmented with an immiscible oil reducing sample waste and demonstrate droplet injection at the EuXFEL compatible with high pressure liquid delivery of an SFX experiment. While achieving ~60% reduction in sample waste, we determine the structure of the enzyme 3-deoxy-D-manno-octulosonate-8-phosphate synthase from microcrystals delivered in droplets revealing distinct structural features not previously reported.


Assuntos
Cristalografia/instrumentação , Elétrons , Dispositivos Lab-On-A-Chip , Lasers , Aldeído Liases/ultraestrutura , Proteínas de Escherichia coli/ultraestrutura , Hidrodinâmica
8.
J Appl Crystallogr ; 53(Pt 4): 927-936, 2020 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-32788900

RESUMO

The ever-increasing brightness of synchrotron radiation sources demands improved X-ray optics to utilize their capability for imaging and probing biological cells, nano-devices and functional matter on the nanometre scale with chemical sensitivity. Hard X-rays are ideal for high-resolution imaging and spectroscopic applications owing to their short wavelength, high penetrating power and chemical sensitivity. The penetrating power that makes X-rays useful for imaging also makes focusing them technologically challenging. Recent developments in layer deposition techniques have enabled the fabrication of a series of highly focusing X-ray lenses, known as wedged multi-layer Laue lenses. Improvements to the lens design and fabrication technique demand an accurate, robust, in situ and at-wavelength characterization method. To this end, a modified form of the speckle tracking wavefront metrology method has been developed. The ptychographic X-ray speckle tracking method is capable of operating with highly divergent wavefields. A useful by-product of this method is that it also provides high-resolution and aberration-free projection images of extended specimens. Three separate experiments using this method are reported, where the ray path angles have been resolved to within 4 nrad with an imaging resolution of 45 nm (full period). This method does not require a high degree of coherence, making it suitable for laboratory-based X-ray sources. Likewise, it is robust to errors in the registered sample positions, making it suitable for X-ray free-electron laser facilities, where beam-pointing fluctuations can be problematic for wavefront metrology.

10.
Nat Commun ; 10(1): 2589, 2019 06 13.
Artigo em Inglês | MEDLINE | ID: mdl-31197138

RESUMO

X-ray free electron lasers (XFELs) create new possibilities for structural studies of biological objects that extend beyond what is possible with synchrotron radiation. Serial femtosecond crystallography has allowed high-resolution structures to be determined from micro-meter sized crystals, whereas single particle coherent X-ray imaging requires development to extend the resolution beyond a few tens of nanometers. Here we describe an intermediate approach: the XFEL imaging of biological assemblies with helical symmetry. We collected X-ray scattering images from samples of microtubules injected across an XFEL beam using a liquid microjet, sorted these images into class averages, merged these data into a diffraction pattern extending to 2 nm resolution, and reconstructed these data into a projection image of the microtubule. Details such as the 4 nm tubulin monomer became visible in this reconstruction. These results illustrate the potential of single-molecule X-ray imaging of biological assembles with helical symmetry at room temperature.


Assuntos
Elétrons , Lasers , Microtúbulos/ultraestrutura , Imagem Molecular/métodos , Tubulina (Proteína)/ultraestrutura , Algoritmos , Cristalografia por Raios X/instrumentação , Cristalografia por Raios X/métodos , Processamento de Imagem Assistida por Computador , Imagem Molecular/instrumentação , Espalhamento de Radiação , Síncrotrons , Raios X
11.
Nat Commun ; 9(1): 4025, 2018 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-30279492

RESUMO

The new European X-ray Free-Electron Laser is the first X-ray free-electron laser capable of delivering X-ray pulses with a megahertz inter-pulse spacing, more than four orders of magnitude higher than previously possible. However, to date, it has been unclear whether it would indeed be possible to measure high-quality diffraction data at megahertz pulse repetition rates. Here, we show that high-quality structures can indeed be obtained using currently available operating conditions at the European XFEL. We present two complete data sets, one from the well-known model system lysozyme and the other from a so far unknown complex of a ß-lactamase from K. pneumoniae involved in antibiotic resistance. This result opens up megahertz serial femtosecond crystallography (SFX) as a tool for reliable structure determination, substrate screening and the efficient measurement of the evolution and dynamics of molecular structures using megahertz repetition rate pulses available at this new class of X-ray laser source.

12.
IUCrJ ; 5(Pt 5): 574-584, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30224961

RESUMO

Liquid microjets are a common means of delivering protein crystals to the focus of X-ray free-electron lasers (FELs) for serial femtosecond crystallography measurements. The high X-ray intensity in the focus initiates an explosion of the microjet and sample. With the advent of X-ray FELs with megahertz rates, the typical velocities of these jets must be increased significantly in order to replenish the damaged material in time for the subsequent measurement with the next X-ray pulse. This work reports the results of a megahertz serial diffraction experiment at the FLASH FEL facility using 4.3 nm radiation. The operation of gas-dynamic nozzles that produce liquid microjets with velocities greater than 80 m s-1 was demonstrated. Furthermore, this article provides optical images of X-ray-induced explosions together with Bragg diffraction from protein microcrystals exposed to trains of X-ray pulses repeating at rates of up to 4.5 MHz. The results indicate the feasibility for megahertz serial crystallography measurements with hard X-rays and give guidance for the design of such experiments.

13.
Light Sci Appl ; 7: 17162, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30839543

RESUMO

Multilayer Laue lenses are volume diffraction elements for the efficient focusing of X-rays. With a new manufacturing technique that we introduced, it is possible to fabricate lenses of sufficiently high numerical aperture (NA) to achieve focal spot sizes below 10 nm. The alternating layers of the materials that form the lens must span a broad range of thicknesses on the nanometer scale to achieve the necessary range of X-ray deflection angles required to achieve a high NA. This poses a challenge to both the accuracy of the deposition process and the control of the materials properties, which often vary with layer thickness. We introduced a new pair of materials-tungsten carbide and silicon carbide-to prepare layered structures with smooth and sharp interfaces and with no material phase transitions that hampered the manufacture of previous lenses. Using a pair of multilayer Laue lenses (MLLs) fabricated from this system, we achieved a two-dimensional focus of 8.4 × 6.8 nm2 at a photon energy of 16.3 keV with high diffraction efficiency and demonstrated scanning-based imaging of samples with a resolution well below 10 nm. The high NA also allowed projection holographic imaging with strong phase contrast over a large range of magnifications. An error analysis indicates the possibility of achieving 1 nm focusing.

14.
J Synchrotron Radiat ; 24(Pt 6): 1296-1298, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29091073

RESUMO

The success of diffraction experiments from weakly scattering samples strongly depends on achieving an optimal signal-to-noise ratio. This is particularly important in single-particle imaging experiments where diffraction signals are typically very weak and the experiments are often accompanied by significant background scattering. A simple way to tremendously reduce background scattering by placing an aperture downstream of the sample has been developed and its application in a single-particle X-ray imaging experiment at FLASH is demonstrated. Using the concept of a post-sample aperture it was possible to reduce the background scattering levels by two orders of magnitude.

15.
IUCrJ ; 4(Pt 6): 795-811, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29123682

RESUMO

Serial diffraction data collected at the Linac Coherent Light Source from crystalline amyloid fibrils delivered in a liquid jet show that the fibrils are well oriented in the jet. At low fibril concentrations, diffraction patterns are recorded from single fibrils; these patterns are weak and contain only a few reflections. Methods are developed for determining the orientation of patterns in reciprocal space and merging them in three dimensions. This allows the individual structure amplitudes to be calculated, thus overcoming the limitations of orientation and cylindrical averaging in conventional fibre diffraction analysis. The advantages of this technique should allow structural studies of fibrous systems in biology that are inaccessible using existing techniques.

16.
Cytoskeleton (Hoboken) ; 74(12): 472-481, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28574190

RESUMO

A major goal for X-ray free-electron laser (XFEL) based science is to elucidate structures of biological molecules without the need for crystals. Filament systems may provide some of the first single macromolecular structures elucidated by XFEL radiation, since they contain one-dimensional translational symmetry and thereby occupy the diffraction intensity region between the extremes of crystals and single molecules. Here, we demonstrate flow alignment of as few as 100 filaments (Escherichia coli pili, F-actin, and amyloid fibrils), which when intersected by femtosecond X-ray pulses result in diffraction patterns similar to those obtained from classical fiber diffraction studies. We also determine that F-actin can be flow-aligned to a disorientation of approximately 5 degrees. Using this XFEL-based technique, we determine that gelsolin amyloids are comprised of stacked ß-strands running perpendicular to the filament axis, and that a range of order from fibrillar to crystalline is discernable for individual α-synuclein amyloids.


Assuntos
Actinas/química , Amiloide/química , Escherichia coli/química , Fímbrias Bacterianas/química , Lasers , Raios X , Amiloide/ultraestrutura , Fímbrias Bacterianas/ultraestrutura
17.
Sci Data ; 3: 160060, 2016 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-27479754

RESUMO

Free-electron lasers (FEL) hold the potential to revolutionize structural biology by producing X-ray pules short enough to outrun radiation damage, thus allowing imaging of biological samples without the limitation from radiation damage. Thus, a major part of the scientific case for the first FELs was three-dimensional (3D) reconstruction of non-crystalline biological objects. In a recent publication we demonstrated the first 3D reconstruction of a biological object from an X-ray FEL using this technique. The sample was the giant Mimivirus, which is one of the largest known viruses with a diameter of 450 nm. Here we present the dataset used for this successful reconstruction. Data-analysis methods for single-particle imaging at FELs are undergoing heavy development but data collection relies on very limited time available through a highly competitive proposal process. This dataset provides experimental data to the entire community and could boost algorithm development and provide a benchmark dataset for new algorithms.


Assuntos
Mimiviridae , Difração de Raios X , Algoritmos , Simulação por Computador , Cristalografia por Raios X , Coleta de Dados , Elétrons , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Lasers , Modelos Teóricos , Tamanho da Partícula , Espalhamento de Radiação , Raios X
18.
Faraday Discuss ; 171: 357-71, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25415133

RESUMO

X-Ray absorption spectromicroscopy provides rich information on the chemical organization of materials down to the nanoscale. However, interpretation of this information in studies of "natural" materials such as biological or environmental science specimens can be complicated by the complex mixtures of spectroscopically complicated materials present. We describe here the shortcomings that sometimes arise in previously-employed approaches such as cluster analysis, and we present a new approach based on non-negative matrix approximation (NNMA) analysis with both sparseness and cluster-similarity regularizations. In a preliminary study of the large-scale biochemical organization of human spermatozoa, NNMA analysis delivers results that nicely show the major features of spermatozoa with no physically erroneous negative weightings or thicknesses in the calculated image.


Assuntos
Análise Espectral/métodos , Espermatozoides/química , Análise por Conglomerados , Humanos , Masculino , Microscopia , Raios X
19.
Opt Express ; 22(23): 28914-25, 2014 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-25402130

RESUMO

We use a Mach-Zehnder type autocorrelator to split and delay XUV pulses from the FLASH soft X-ray laser for triggering and subsequently probing the explosion of aerosolised sugar balls. FLASH was running at 182 eV photon energy with pulses of 70 fs duration. The delay between the pump-probe pulses was varied between zero and 5 ps, and the pulses were focused to reach peak intensities above 10¹6W/cm² with an off-axis parabola. The direct pulse triggered the explosion of single aerosolised sucrose nano-particles, while the delayed pulse probed the exploding structure. The ejected ions were measured by ion time of flight spectrometry, and the particle sizes were measured by coherent diffractive imaging. The results show that sucrose particles of 560-1000 nm diameter retain their size for about 500 fs following the first exposure. Significant sample expansion happens between 500 fs and 1 ps. We present simulations to support these observations.


Assuntos
Elétrons , Imageamento Tridimensional/métodos , Lasers , Nanosferas/química , Análise Espectral/métodos , Sacarose/química , Simulação por Computador , Hidrogênio/química , Íons , Termodinâmica , Raios X
20.
Nature ; 513(7517): 261-5, 2014 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-25043005

RESUMO

Photosynthesis, a process catalysed by plants, algae and cyanobacteria converts sunlight to energy thus sustaining all higher life on Earth. Two large membrane protein complexes, photosystem I and II (PSI and PSII), act in series to catalyse the light-driven reactions in photosynthesis. PSII catalyses the light-driven water splitting process, which maintains the Earth's oxygenic atmosphere. In this process, the oxygen-evolving complex (OEC) of PSII cycles through five states, S0 to S4, in which four electrons are sequentially extracted from the OEC in four light-driven charge-separation events. Here we describe time resolved experiments on PSII nano/microcrystals from Thermosynechococcus elongatus performed with the recently developed technique of serial femtosecond crystallography. Structures have been determined from PSII in the dark S1 state and after double laser excitation (putative S3 state) at 5 and 5.5 Å resolution, respectively. The results provide evidence that PSII undergoes significant conformational changes at the electron acceptor side and at the Mn4CaO5 core of the OEC. These include an elongation of the metal cluster, accompanied by changes in the protein environment, which could allow for binding of the second substrate water molecule between the more distant protruding Mn (referred to as the 'dangler' Mn) and the Mn3CaOx cubane in the S2 to S3 transition, as predicted by spectroscopic and computational studies. This work shows the great potential for time-resolved serial femtosecond crystallography for investigation of catalytic processes in biomolecules.


Assuntos
Cristalografia por Raios X , Cianobactérias/química , Modelos Moleculares , Complexo de Proteína do Fotossistema II/química , Estrutura Terciária de Proteína
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...