Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Semin Thorac Cardiovasc Surg ; 34(1): 226-235, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33242612

RESUMO

This study aims to assess the differences in pressure, fractional flow reserve (FFR) and coronary flow (with increasing pressure) of the proximal coronary artery in patients with anomalous aortic origin of a coronary artery with a confirmed ischemic event, without ischemic events, and before and after unroofing surgery, and compare to a patient with normal coronary arteries. Patient-specific flow models were 3D printed for 3 subjects with anomalous right coronary arteries with intramural course, 2 of them had documented ischemia, and compared with a patient with normal coronaries. The models were placed in the aortic position of a pulse duplicator and precise measurements to quantify FFR and coronary flow rate were performed from the aortic to the mediastinal segment of the anomalous right coronary artery. In an ischemic model, a gradual FFR drop (emulating that of pressure) was shown from the ostium location (∼1.0) to the distal intramural course (0.48). In nonischemic and normal patient models, FFR for all locations did not drop below 0.9. In a second ischemic model prior to repair, a drop to 0.44 was encountered at the intramural and mediastinal intersection, improving to 0.86 postrepair. There is a difference in instantaneous coronary flow rate with increasing aortic pressure in the ischemic models (slope 0.2846), compared to the postrepair and normal models (slope >0.53). These observations on patient models support a biomechanical basis for ischemia and potentially sudden cardiac death in aortic origin of a coronary artery, with a drop in pressure and FFR in the intramural segment, and a decrease in coronary flow rate with increasing aortic pressure, with both improving after corrective surgery.


Assuntos
Anomalias dos Vasos Coronários , Reserva Fracionada de Fluxo Miocárdico , Aorta/diagnóstico por imagem , Aorta/cirurgia , Criança , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Resultado do Tratamento
2.
Comput Methods Programs Biomed ; 201: 105947, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33535084

RESUMO

BACKGROUND AND OBJECTIVE: This study aims to determine the accuracy of patient specific 3D printed models in capturing pathological anatomical characteristics derived from CT angiography (CTA) in children with anomalous aortic origin of a coronary artery (AAOCA). METHODS & MATERIALS: Following institutional regulatory approval, a standardized protocol for CTA of AAOCA was utilized for imaging. Blood volume of the aorta and coronaries were segmented from the DICOM images. A total of 10 models from 8 AAOCA patients were created, including 2 post-operative models. Mechanical properties of Agilus30 a flexible photopolymer coated with a thin layer of parylene, polyurethane (PU) and silicone and native aortic tissue from a postmortem specimen were compared. AAOCA models with wall thicknesses of 2mm aorta and 1.5mm coronaries were 3D printed in Agilus30 and coated with PU. CT of the printed models was performed, and 3D virtual models were generated. Transfer of anatomical characteristics and geometric accuracy were compared between the patient model virtual models. RESULTS: Dynamic modulus of Agilus30 at 2mm thickness was found to be close to native aortic tissue. Structured reporting of anatomical characteristics by imaging experts showed good concordance between patient and model CTA Comparative patient and virtual model measurements showed Pearson's correlation (r) of 0.9959 for aorta (n=70) and 0.9538 for coronaries (n=60) linear, and 0.9949 for aorta (n=30) and 0.9538 for coronaries (n=30) cross-sectional, dimensions. Surface contour map mean difference was 0.08 ± 0.29mm. CONCLUSIONS: Geometrically accurate AAOCA models preserving morphological characteristics, essential for risk stratification and decision-making, can be 3D printed from a patient's CTA.


Assuntos
Anomalias dos Vasos Coronários , Aorta/diagnóstico por imagem , Criança , Estudos Transversais , Estudos de Viabilidade , Humanos , Impressão Tridimensional
3.
Ann Biomed Eng ; 48(12): 2796-2808, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33145675

RESUMO

Coronary flow induces hemodynamic alterations in the aortic sinus region. The objectives of this study are to: (1) investigate the differences among sinus hemodynamics and leaflet wall shear stresses engendered by the left versus right versus non-coronary flow and (2) correlate respective wall shear stresses with leaflet calcification in patients. A left heart simulator flow loop with a tunable coronary circuit provided physiological coronary flow waveforms corresponding to the left coronary cusp case (LCC), right coronary cusp case (RCC), and non-coronary cusp case (NCC). High spatio-temporal resolution particle image velocimetry was conducted to quantify leaflet wall shear stress and sinus vorticity fields and to measure aortic leaflet tip kinematics. Thirty-one patients with severe calcific aortic valve disease were segmented from CT data for the calcific volumes in their respective left, right, and non-coronary cusps. Leaflet tip position during systole shows the RCC has a wider leaflet opening compared to LCC and NCC. Velocity and vorticity fields combined with leaflet position data show that sinus vorticity is diminished (peak ~ 43 s-1) in the LCC while RCC and NCC maintain high vorticity (~ 1200 and ~ 950 s-1 respectively). WSS magnitudes greater than 0.3 Pa show 20 and 81% greater occurrences in the LCC and RCC respectively compared to NCC. Significant differences [X2 (2, n = 31) = 7.31, p = 0.0258] between the calcification levels in each cusp of the patient population. Coronary flow differences between LCC, RCC, and NCC show significant impact on leaflet kinematics and sinus flow hemodynamics. Clinical data correlations of the coronary flow cases indicate the left coronary cusp has a higher likelihood of calcification compared to the right.


Assuntos
Estenose da Valva Aórtica/fisiopatologia , Valva Aórtica/patologia , Calcinose/fisiopatologia , Circulação Coronária , Seio Aórtico/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Angiografia por Tomografia Computadorizada , Feminino , Hemodinâmica , Humanos , Masculino , Modelos Cardiovasculares , Seio Aórtico/diagnóstico por imagem , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...