RESUMO
BACKGROUND: Stentless aortic valves were designed to provide a more physiological flow pattern and lower transvalvular gradient, which may have an important bearing on postoperative left ventricular function and remodeling. In this study, we prospectively analyzed the 5-year clinical results with the Freestyle valve (Medtronic, Inc) and its hemodynamic performance by serial echocardiography. METHODS AND RESULTS: Between January 1993 and August 1997, 95 patients with a mean age of 75 years underwent aortic valve replacement with the Freestyle prosthesis. Sixty-four percent of patients received valves =23 mm, and 37% had concomitant coronary artery bypass grafting. Average follow-up was 44+/-18 months (mean+/-SD), and echocardiography was performed preoperatively, at discharge, at 3 to 6 months, and annually thereafter. The 30-day operative mortality rate was 3%, with an overall actuarial survival rate of 80+/-6% (mean+/-SEM) at 5 years. Of the 10 late deaths, only 2 were cardiac related, thereby yielding a freedom from cardiac mortality of 94+/-3% after 5 years. No patient required reoperation on the aortic valve for any reason, including structural degeneration, nonstructural dysfunction, or prosthetic valve endocarditis. There were 9 thromboembolic and 3 anticoagulant-related bleeding events, none of which was fatal. The actuarial freedom from valve-related morbidity and mortality was 79+/-4% at 5 years. Hemodynamically, the mean transvalvular gradient significantly decreased after valve replacement and was reduced further by 41% by 6 months with a corresponding increase in effective orifice area. Left ventricular mass index fell to 75% of the preoperative value by 2 years. CONCLUSIONS: The Freestyle stentless valve can be implanted safely in the elderly with excellent midterm clinical results. It has superb hemodynamics in terms of residual transvalvular gradient, effective orifice area, and regression of left ventricular hypertrophy.
Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Ecocardiografia , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Estudos Prospectivos , Stents , Análise de SobrevidaRESUMO
BACKGROUND: The merits of retaining the subvalvular apparatus during mitral valve replacement for chronic mitral regurgitation have been demonstrated in numerous clinical and laboratory investigations. In this preliminary report, we analyzed the early effects of complete versus partial chordal preservation on left ventricular mechanics. METHODS AND RESULTS: Fifty patients undergoing isolated surgical correction of mitral insufficiency were prospectively randomized to either total or partial chordal-sparing mitral valve replacement. Of the first 19 patients studied, 8 had preservation of the posterior leaflet only, and 11 had complete preservation of all chordal structures. A comparison group consisted of 6 patients who had primary mitral valve repair. Echocardiography was performed preoperatively and at discharge from the hospital to determine dimensions, wall stress, and ejection fraction. Preservation of the posterior leaflet only resulted in a reduction in end-diastolic volume, an increase in end-systolic volume (P=0.058), a rising trend in end-systolic stress, a decrease in long-axis fractional shortening, and a fall in ejection fraction from 0.68+/-0.16 to 0. 46+/-0.19 (P=0.001). Although patients who had preservation of all chordal structures also had decreased end-diastolic volume, long-axis fractional shortening, and ejection fraction (0.60+/-0.13 to 0.52+/-0.07, P=0.01), end-systolic stress fell and end-systolic volume decreased instead of increased. Compared with the posterior leaflet preservation group, those in the group with completely preserved chordal structures had a larger decline in end-diastolic volume and smaller decreases in long-axis fractional shortening and ejection fraction. Changes in end-systolic volume and stress were also statistically different between the 2 cohorts. No differences were detected between the group with total preserved chordal structures and the mitral repair group in any of the measured parameters. CONCLUSIONS: Compared with posterior chordal preservation only, complete retention of the subvalvular apparatus during mitral valve replacement resulted in improved ejection performance and smaller chamber volumes due to reduced systolic wall stress. These hemodynamic advantages are comparable to those observed with primary mitral reconstruction.
Assuntos
Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do TratamentoRESUMO
BACKGROUND: Due to improved operative techniques, myocardial preservation, and perioperative care, open heart procedures are now being performed in older and sicker patients. As a result, the quality of life has become an important issue in the decision making process. METHODS: Between January 1993 and October 1994, 604 patients above 65 years of age who underwent non-emergent open heart operations were followed prospectively over a 2-year period. The Health Status Questionnaire forms were distributed to all patients preoperatively and to hospital survivors at 3, 12, and 24 months. The questionnaire contains 36 questions and is divided into eight categories. Follow-up was 100% complete with 99.6% of questionnaires returned. RESULTS: Significant quality of life improvements were noted in all categories after surgery. After reaching a peak at 12 months, there were small, but significant declines in scores relating to physical health and health perception at 24 months. In contrast, measurements for mental attributes continued to increase with time. By multivariate analysis, diabetes, older age, and female gender had a relatively adverse influence on quality of life despite improvement after operation. Similarly, patients with chronic obstructive pulmonary disease or having redo operations had lower health perception with some physical limitations. While procedure type (coronary artery bypass grafting) was associated with preoperative bodily pain, congestive heart failure symptoms were not an independent factor affecting quality of life. CONCLUSIONS: Quality of life improves with cardiac surgical interventions in this studied age group and should not be denied even in the elderly population.
Assuntos
Ponte de Artéria Coronária , Implante de Prótese de Valva Cardíaca , Complicações Pós-Operatórias/etiologia , Qualidade de Vida , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , ReoperaçãoRESUMO
BACKGROUND: Many studies have demonstrated the superior hemodynamics of stentless porcine aortic valves compared to stented valves. This article describes the operative techniques and reviews our 5-year experience with the Medtronic Freestyle stentless valve. METHODS: Between January 1993 and November 1997, 95 patients underwent implantation of the Medtronic Freestyle valve at a mean age of 76 years. All patients were seen at 6 months, 1 year, and annually thereafter for clinical assessment and Doppler echocardiography. RESULTS: There were three operative and ten late deaths (two cardiac and eight noncardiac). Three strokes and four transient ischemic attacks occurred in the follow-up period. Four patients had bacteremia that was treated successfully with antibiotics. No patient required reoperation for valve-related problems. Serial echocardiograms revealed a decrease in mean systolic gradients across the valve during the first year and an increase in effective orifice areas. Ninety-one percent of patients had no, or trace, aortic insufficiency at the time of discharge and this has not increased over time. CONCLUSION: The Medtronic Freestyle valve has excellent hemodynamics and good clinical results. In our experience, no patient has required reoperation in a 5-year follow-up.
Assuntos
Bioprótese , Materiais Revestidos Biocompatíveis , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia Doppler , Feminino , Seguimentos , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Ácidos Oleicos , Polietilenotereftalatos , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do TratamentoRESUMO
BACKGROUND AND AIMS OF THE STUDY: Aortic root enlargement in the elderly patient prolongs aortic valve replacement procedures and may be problematic if the root is calcified. Mechanical valves have superior hemodynamics compared to tissue valves in the smaller sizes but are often contraindicated in the older patient. MATERIALS AND METHODS: Between January 1993 and November 1995, we implanted 80 Freestyle (Medtronic, Irvine, CA) stentless porcine valves using the freehand subcoronary technique. Twenty-seven of the patients had small aortic roots with an average age of 76.3 years (69-84). Seven patients received size 19 valves and 20 patients had size 21 valves. RESULTS: The average echocardiographic gradient at hospital discharge was 17.9 mmHg (12.1-23.0) for size 19 valves and 15.3 mmHg (5.7-27.9) for size 21. At one year postoperative follow up the average gradient had decreased to 12.9 mmHg (9.3-17.5) for size 19 and 8.0 mmHg (2.2-19.3) for size 21 valves. Effective orifice areas increased from 1.09 cm2 at the time of discharge to 1.29 cm2 at one year follow up for size 19 valves, and from 1.30 cm2 to 1.56 cm2 for size 21. No patient had more than mild aortic insufficiency at most recent follow up. CONCLUSION: This stentless porcine prosthesis has excellent hemodynamics in the smaller valve sizes which improve at least during the first year following surgery. We feel that it is the valve of choice in older patients with small aortic roots.
Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese/instrumentação , Próteses Valvulares Cardíacas/instrumentação , Complicações Pós-Operatórias/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Estenose da Valva Aórtica/patologia , Feminino , Próteses Valvulares Cardíacas/métodos , Hemodinâmica/fisiologia , Humanos , Masculino , Prognóstico , Stents , Taxa de SobrevidaRESUMO
The Medtronic Freestyle bioprosthesis is a stentless porcine aortic root cross-linked in dilute glutaraldehyde solution with stress-free fixation for the valve leaflets. It has been treated by a process in which amino oleic acid is used to reduce the potential for calcification. As a complete aortic root, it has the same versatility as the aortic homograft but has the advantage that it is readily available in all sizes to the implanting surgeon. Between January 1993 and May 1994, we implanted 64 Freestyle bioprostheses as aortic valve replacements using a freehand technique; 5 size 19 mm, 15 size 21 mm, 16 size 23 mm, 13 size 25 mm, and 15 size 27 mm valves were used. There were 35 men and the mean age was 75.7 years (64 to 84 years). The operative mortality was 3.1% (2/64). Echocardiograms at the time of discharge revealed mean aortic valve gradients ranging from 18.2 mm Hg for 19 mm to 10.3 mm Hg for 27 mm valves. Effective orifice areas ranged from 1.0 cm2 for 19 mm to 2.0 cm2 for 27 mm valves. No patient had more than trace aortic insufficiency. Our early experience with this new stentless bioprosthesis shows it to have excellent hemodynamics especially in the smaller valve sizes. Using this valve in patients who have a small aortic root and require a tissue valve avoids the need for aortic root enlargement procedures.