Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
3.
J Thorac Cardiovasc Surg ; 149(2 Suppl): S37-45, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25240525

RESUMO

OBJECTIVE: The study objective was to compare the 30-day outcomes of a standardized aortic valve repair technique (REPAIR group) associating root remodeling with an expansible aortic ring annuloplasty versus mechanical composite valve and graft (CVG group) replacement in treating aortic root aneurysms. METHODS: A total of 261 consecutive patients with aortic root aneurysm were enrolled in this multicentric prospective cohort (131 in the CVG group, 130 in the REPAIR group) in 20 centers. The main end point is a composite criterion including mortality; reoperation; thromboembolic, hemorrhagic, or infectious events; and heart failure. Secondary end points were major adverse valve-related events. Crude and propensity score adjusted estimates are provided. RESULTS: The mean age was 56.1 years, and the valve was bicuspid in 115 patients (44.7%). The median (interquartile range) preoperative aortic insufficiency grade was 2.0 (1.0-3.0) in the REPAIR group and 3.0 (2.0-3.0) in the CVG group (P = .0002). Thirty-day mortality was 3.8% (n = 5) in both groups (P = 1.00). Despite a learning curve and longer crossclamp times for valve repair (147.7 vs 99.8 minutes, P < .0001), the 2 groups did not differ significantly for the main criterion (odds ratio, 1.31; 95% confidence interval, 0.72-2.40; P = .38) or 30-day mortality (odds ratio, 0.99; 95% confidence interval, 0.28-3053; P = .99), with a trend toward more frequent major adverse valve-related events in the CVG group (odds ratio, 2.52; 95% confidence interval, 0.86-7.40; P = .09). At discharge, 121 patients (96.8%) in the REPAIR group had grade 0 or 1 aortic insufficiency. CONCLUSIONS: A new standardized approach to valve repair, combining an expansible aortic annuloplasty ring with the remodeling technique, presented similar 30-day results to mechanical CVG with a trend toward reducing major adverse valve-related events. Analysis of late outcomes is in process for 3- and 10-year follow-ups.


Assuntos
Aneurisma Aórtico/cirurgia , Valva Aórtica/anormalidades , Implante de Prótese Vascular , Anuloplastia da Valva Cardíaca , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico , Aneurisma Aórtico/mortalidade , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Anuloplastia da Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Cardíaca/mortalidade , Distribuição de Qui-Quadrado , Intervalo Livre de Doença , Feminino , França , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Preferência do Paciente , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Pontuação de Propensão , Estudos Prospectivos , Desenho de Prótese , Reoperação , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...