Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
EJVES Vasc Forum ; 59: 24-30, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37389371

RESUMO

Objective: Fiber Optic RealShape (FORS) is a new technology that visualises the full three dimensional (3D) shape of guidewires using an optical fibre embedded in the device. Co-registering FORS guidewires with anatomical images, such as a digital subtraction angiography (DSA), provides anatomical context for navigating these devices during endovascular procedures. The objective of this study was to demonstrate the feasibility and usability of visualising compatible conventional navigation catheters, together with the FORS guidewire, in phantom with a new 3D Hub technology and to understand potential clinical benefits. Methods: The accuracy of localising the 3D Hub and catheter in relation to the FORS guidewire, was evaluated using a translation stage test setup and a retrospective analysis of prior clinical data. Catheter visualisation accuracy and navigation success was assessed in a phantom study where 15 interventionists navigated devices to three pre-defined targets in an abdominal aortic phantom using an Xray or computed tomography angiography (CTA) roadmap. Additionally, the interventionists were surveyed about the usability and potential benefits of the 3D Hub. Results: The location of the 3D Hub and catheter along the FORS guidewire was detected correctly 96.59% of the time. During the phantom study, all 15 interventionists successfully reached the target locations 100% of the time and the error in catheter visualisation was 0.69 mm. The interventionists agreed or strongly agreed that the 3D Hub was easy to use and the greatest potential clinical benefit over FORS is in offering interventionists choice over which catheter they used. Conclusion: This set of studies has shown that FORS guided catheter visualisation, enabled by a 3D Hub, is accurate and easy to use in a phantom setting. Further evaluation is needed to understand the benefits and limitations of the 3D Hub technology during endovascular procedures.

2.
J Biomed Opt ; 18(9): 096012, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24048367

RESUMO

Diffuse optical tomography (DOT) is a noninvasive, nonionizing imaging modality that uses near-infrared light to visualize optically relevant chromophores. A recently developed dynamic DOT imaging system enables the study of hemodynamic effects in the breast during a breath-hold. Dynamic DOT imaging was performed in a total of 21 subjects (age 54±10 years) including 3 healthy subjects and 18 subjects with benign (n=8) and malignant (n=14) masses. Three-dimensional time-series images of the percentage change in oxygenated and deoxygenated hemoglobin concentrations ([HbO2] and [Hb]) from baseline are obtained over the course of a breath-hold. At a time point of 15 s following the end of the breath-hold, [Hb] in healthy breasts has returned to near-baseline values (1.6%±0.5%), while tumor-bearing breasts have increased levels of [Hb] (6.8%±3.6%, p<0.01). Further, healthy subjects have a higher correlation between the breasts over the course of the breath-hold as compared with the subjects with breast cancer (healthy: 0.96±0.02; benign: 0.89±0.02; malignant: 0.78±0.23, p<0.05). Therefore this study shows that dynamic features extracted from DOT measurements can differentiate healthy and diseased breast tissues. These features provide a physiologic method for identifying breast cancer without the need for ionizing radiation.


Assuntos
Biomarcadores Tumorais/química , Neoplasias da Mama/química , Imageamento Tridimensional/métodos , Tomografia Óptica/métodos , Adulto , Biomarcadores Tumorais/sangue , Neoplasias da Mama/irrigação sanguínea , Neoplasias da Mama/fisiopatologia , Suspensão da Respiração , Feminino , Hemodinâmica/fisiologia , Hemoglobinas/análise , Humanos , Pessoa de Meia-Idade , Oxiemoglobinas/análise
3.
Ultrasound Med Biol ; 38(6): 1019-29, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22425376

RESUMO

Agents targeting vascular endothelial growth factor (VEGF) have been validated as cancer therapeutics, yet efficacy can differ widely between tumor types and individual patients. In addition, such agents are costly and can have significant toxicities. Rapid noninvasive determination of response could provide significant benefits. We tested if response to the anti-VEGF antibody bevacizumab (BV) could be detected using contrast-enhanced ultrasound imaging (CEUS). We used two xenograft model systems with previously well-characterized responses to VEGF inhibition, a responder (SK-NEP-1) and a non-responder (NGP), and examined perfusion-related parameters. CEUS demonstrated that BV treatment arrested the increase in blood volume in the SK-NEP-1 tumor group only. Molecular imaging of α(V)ß(3) with targeted microbubbles was a more sensitive prognostic indicator of BV efficacy. CEUS using RGD-labeled microbubbles showed a robust decrease in α(V)ß(3) vasculature following BV treatment in SK-NEP-1 tumors. Paralleling these findings, lectin perfusion assays detected a disproportionate pruning of smaller, branch vessels. Therefore, we conclude that the response to BV can be identified soon after initiation of treatment, often within 3 days, by use of CEUS molecular imaging techniques. The use of a noninvasive ultrasound approach may allow for earlier and more effective determination of efficacy of antiangiogenic therapy.


Assuntos
Inibidores da Angiogênese/farmacologia , Anticorpos Monoclonais Humanizados/farmacologia , Neovascularização Patológica/diagnóstico por imagem , Neovascularização Patológica/tratamento farmacológico , Neuroblastoma/diagnóstico por imagem , Neuroblastoma/tratamento farmacológico , Sarcoma de Ewing/diagnóstico por imagem , Sarcoma de Ewing/tratamento farmacológico , Animais , Bevacizumab , Volume Sanguíneo , Meios de Contraste , Progressão da Doença , Camundongos , Camundongos Nus , Microbolhas , Prognóstico , Análise de Regressão , Ultrassonografia , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores
4.
J Biomed Opt ; 17(1): 016014, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22352664

RESUMO

Although anti-angiogenic agents have shown promise as cancer therapeutics, their efficacy varies between tumor types and individual patients. Providing patient-specific metrics through rapid noninvasive imaging can help tailor drug treatment by optimizing dosages, timing of drug cycles, and duration of therapy-thereby reducing toxicity and cost and improving patient outcome. Diffuse optical tomography (DOT) is a noninvasive three-dimensional imaging modality that has been shown to capture physiologic changes in tumors through visualization of oxygenated, deoxygenated, and total hemoglobin concentrations, using non-ionizing radiation with near-infrared light. We employed a small animal model to ascertain if tumor response to bevacizumab (BV), an anti-angiogenic agent that targets vascular endothelial growth factor (VEGF), could be detected at early time points using DOT. We detected a significant decrease in total hemoglobin levels as soon as one day after BV treatment in responder xenograft tumors (SK-NEP-1), but not in SK-NEP-1 control tumors or in non-responder control or BV-treated NGP tumors. These results are confirmed by magnetic resonance imaging T2 relaxometry and lectin perfusion studies. Noninvasive DOT imaging may allow for earlier and more effective control of anti-angiogenic therapy.


Assuntos
Monitoramento de Medicamentos/métodos , Neoplasias Experimentais/irrigação sanguínea , Neoplasias Experimentais/tratamento farmacológico , Tomografia Óptica/métodos , Ensaios Antitumorais Modelo de Xenoenxerto/métodos , Análise de Variância , Inibidores da Angiogênese/farmacologia , Animais , Anticorpos Monoclonais Humanizados/farmacologia , Bevacizumab , Feminino , Corantes Fluorescentes , Hemoglobinas/metabolismo , Imageamento por Ressonância Magnética/métodos , Camundongos , Camundongos Nus , Neoplasias Experimentais/metabolismo , Neovascularização Patológica/tratamento farmacológico , Oxiemoglobinas/metabolismo , Imagem de Perfusão , Lectinas de Plantas
5.
J Biomed Opt ; 16(7): 076014, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21806275

RESUMO

Diffuse optical tomography has shown promising results as a tool for breast cancer screening and monitoring response to chemotherapy. Dynamic imaging of the transient response of the breast to an external stimulus, such as pressure or a respiratory maneuver, can provide additional information that can be used to detect tumors. We present a new digital continuous-wave optical tomography system designed to simultaneously image both breasts at fast frame rates and with a large number of sources and detectors. The system uses a master-slave digital signal processor-based detection architecture to achieve a dynamic range of 160 dB and a frame rate of 1.7 Hz with 32 sources, 64 detectors, and 4 wavelengths per breast. Included is a preliminary study of one healthy patient and two breast cancer patients showing the ability to identify an invasive carcinoma based on the hemodynamic response to a breath hold.


Assuntos
Neoplasias da Mama/diagnóstico , Diagnóstico por Imagem/métodos , Tomografia Óptica/métodos , Adulto , Mama/patologia , Neoplasias da Mama/irrigação sanguínea , Neoplasias da Mama/fisiopatologia , Carcinoma Ductal de Mama/irrigação sanguínea , Carcinoma Ductal de Mama/diagnóstico , Carcinoma Ductal de Mama/fisiopatologia , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/estatística & dados numéricos , Desenho de Equipamento , Feminino , Hemodinâmica , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Pessoa de Meia-Idade , Fibras Ópticas , Mecânica Respiratória , Processamento de Sinais Assistido por Computador , Tomografia Óptica/instrumentação , Tomografia Óptica/estatística & dados numéricos , Interface Usuário-Computador
6.
Artigo em Inglês | MEDLINE | ID: mdl-19163523

RESUMO

Optical imaging has the potential to play a major role in breast cancer screening and diagnosis due to its ability to image cancer characteristics such as angiogenesis and hypoxia. A promising approach to evaluate and quantify these characteristics is to perform dynamic imaging studies in which one monitors the hemodynamic response to an external stimulus, such as a valsalva maneuver. It has been shown that the response to such stimuli shows MARKED differences between cancerous and healthy tissues. The fast imaging rates and large dynamic range of digital devices makes them ideal for this type of imaging studies. Here we present a digital optical tomography system designed specifically for dynamic breast imaging. The instrument uses laser diodes at 4 different near-infrared wavelengths with 32 sources and 128 silicon photodiode detectors.


Assuntos
Neoplasias da Mama/diagnóstico , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Espectrofotometria Infravermelho/instrumentação , Tomografia Óptica/instrumentação , Algoritmos , Neoplasias da Mama/diagnóstico por imagem , Computadores , Desenho de Equipamento , Humanos , Óptica e Fotônica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Infravermelho/métodos , Técnica de Subtração , Tomografia Óptica/métodos , Ultrassonografia
7.
Magn Reson Med ; 53(4): 954-9, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15799048

RESUMO

Imaging of the coronary arteries at diagnostic resolutions is made difficult due to cardiac and respiratory motion during data acquisition. Cardiac gating and respiratory gating or breath holding are effective ways to reduce the effects of motion. The optimal cardiac and respiratory timings vary widely across individuals. This work presents a real-time magnetic resonance imaging approach with physiologic monitoring that can be used to predict the optimal timings on a subject-by-subject basis during a brief real-time prescan. The feasibility of this approach at determining the optimal cardiac trigger delay and respiratory phase is demonstrated.


Assuntos
Circulação Coronária/fisiologia , Angiografia por Ressonância Magnética/métodos , Monitorização Fisiológica/métodos , Interface Usuário-Computador , Adulto , Feminino , Humanos , Masculino , Respiração
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...