Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Am J Transplant ; 23(8): 1227-1240, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37156300

RESUMO

Intracardiac thrombosis and/or pulmonary thromboembolism (ICT/PE) is a rare but devastating complication during liver transplantation. Its pathophysiology remains poorly understood, and successful treatment remains a challenge. This systematic review summarizes the available published clinical data regarding ICT/PE during liver transplantation. Databases were searched for all publications reporting on ICT/PE during liver transplantation. Data collected included its incidence, patient characteristics, the timing of diagnosis, treatment strategies, and patient outcomes. This review included 59 full-text citations. The point prevalence of ICT/PE was 1.42%. Thrombi were most often diagnosed during the neohepatic phase, particularly at allograft reperfusion. Intravenous heparin was effective in preventing early-stage thrombus from progressing further and restoring hemodynamics in 76.32% of patients it was utilized for; however, the addition of tissue plasminogen activator or sole use of tissue plasminogen activator offered diminishing returns. Despite all resuscitation efforts, the in-hospital mortality rate of an intraoperative ICT/PE was 40.42%, with nearly half of these patients dying intraoperatively. The results of our systematic review are an initial step for providing clinicians with data that can help identify higher-risk patients. The clinical implications of our results warrant the development of identification and management strategies for the timely and effective treatment of these tragic occurrences during liver transplantation.


Assuntos
Cardiopatias , Transplante de Fígado , Embolia Pulmonar , Trombose , Humanos , Ativador de Plasminogênio Tecidual , Transplante de Fígado/efeitos adversos , Transplante de Fígado/métodos , Trombose/etiologia , Trombose/diagnóstico , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/tratamento farmacológico , Embolia Pulmonar/etiologia
2.
Liver Transpl ; 29(11): 1216-1225, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-36976255

RESUMO

Blood loss and transfusion of blood products are key concerns during liver transplantation. Whole-blood viscoelastic testing devices have been used to monitor hemostatic function and guide the transfusion of blood products in this patient population. The Quantra System with the QStat Cartridge is a new point-of-care, closed-system viscoelastic testing device that measures changes in clot stiffness during coagulation and fibrinolysis using ultrasound detection of resonance. The aim of this multicenter prospective observational study was to evaluate the Quantra System against the ROTEM delta device in monitoring coagulation and fibrinolysis in patients undergoing liver transplantation. One hundred twenty-five (125) adult subjects (above 18 y old) were enrolled across 5 medical centers in the US. Blood samples were collected at a minimum of 3-time points: preincision (baseline), during the anhepatic phase, and after the start of reperfusion. Performance was assessed as the correlation of equivalent measurements from the QStat Cartridge and ROTEM delta INTEM, EXTEM, and FIBTEM assays. In addition, a clinical concordance analysis was performed to assess the agreement between the 2 devices related to the detection of fibrinolysis. The correlation between the 2 viscoelastic testing devices was strong, with r -values ranging between 0.88 and 0.95, and the overall agreement with respect to detecting fibrinolysis was 90.3% (CI, 86.9%-93.2%). The results indicate that the Quantra with the QStat Cartridge provides comparable information as the ROTEM delta in the assessment of hemostatic function during a liver transplant. Quantra's simplicity of use and availability of rapid results may provide clinicians with a faster, more convenient means to assess coagulation and fibrinolysis status in the operating room and critical care setting.


Assuntos
Hemostáticos , Transplante de Fígado , Humanos , Adulto , Tromboelastografia/métodos , Transplante de Fígado/efeitos adversos , Estudos Prospectivos , Coagulação Sanguínea , Testes de Coagulação Sanguínea/métodos
4.
Cureus ; 14(4): e24119, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35573521

RESUMO

A 38-year-old male presented for orthotopic liver transplantation complicated by new-onset torrential tricuspid regurgitation before incision. Subclinical volume overload and functional tricuspid regurgitation created a challenging scenario in which the benefits of expeditious transplant were weighed against the risks of allograft congestion and failure. Intraoperative transesophageal echocardiography proved critical in diagnosing severe tricuspid regurgitation and guided clinical decision making. In this article, we describe the intraoperative presentation of acutely elevated right heart pressures and the subsequent management of this patient prior to ultimately successful liver transplantation.

5.
J Cardiothorac Vasc Anesth ; 36(8 Pt A): 2606-2615, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34099375

RESUMO

Liver transplantation is associated with significant blood loss, often requiring massive blood product transfusion. Transfusion-related acute lung injury (TRALI) is a devastating cause of transfusion-related deaths. While reports have investigated the general incidence of TRALI, the incidence of TRALI specifically following transfusion during liver transplant remains unclear. This scoping review summarizes existing literature regarding TRALI during the liver transplantation perioperative period. Databases were searched for all articles and abstracts reporting on TRALI after liver transplantation. Data collected included number of patients studied, patient characteristics, incidences of TRALI, TRALI characteristics, and patient outcomes. The primary outcome investigated was the incidence of TRALI in the setting of liver transplantation. Thirteen full-text citations were included in this review. The incidence of TRALI post-liver transplant was 0.68% (65 of 9,554). Based on reported transfusion data, patients diagnosed with TRALI received an average of 10.92 ± 10.81 units of packed red blood cells (pRBC), 20.05 ± 15.72 units of fresh frozen plasma, and 5.75 ± 10.00 units of platelets. Common interventions following TRALI diagnosis included mechanical ventilation with positive end-expiratory pressure, inhaled high-flow oxygen, inhaled pulmonary vasodilator, and pharmacologic treatment using pressors or inotropes, corticosteroids, or diuretics. Based on reported mortality data, 26.67% of patients (12 of 45) diagnosed with TRALI died during the postoperative period. This scoping review underscores the importance of better understanding the incidence and presentation of TRALI after liver transplant surgery. The clinical implications of these results warrant the development of identification and management strategies for liver transplant patients at increased risk for developing TRALI.


Assuntos
Lesão Pulmonar Aguda , Transplante de Fígado , Reação Transfusional , Lesão Pulmonar Aguda Relacionada à Transfusão , Lesão Pulmonar Aguda/diagnóstico , Lesão Pulmonar Aguda/epidemiologia , Lesão Pulmonar Aguda/etiologia , Transfusão de Sangue/métodos , Humanos , Transplante de Fígado/efeitos adversos , Reação Transfusional/epidemiologia , Reação Transfusional/etiologia , Lesão Pulmonar Aguda Relacionada à Transfusão/diagnóstico , Lesão Pulmonar Aguda Relacionada à Transfusão/epidemiologia , Lesão Pulmonar Aguda Relacionada à Transfusão/etiologia
6.
Semin Cardiothorac Vasc Anesth ; 25(3): 191-195, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33853445

RESUMO

In this article, we describe a case of a 33-year-old female with Alagille syndrome complicated by bilateral branch pulmonary artery stenosis resulting in moderate pulmonary hypertension, end-stage liver disease complicated by portal hypertension, and chronic renal disease who presented for combined liver-kidney transplant. Alagille syndrome is an autosomal dominant disease affecting the liver, heart, and kidneys. Multidisciplinary preoperative evaluation was performed with a team consisting of a congenital heart disease cardiologist, a cardiac anesthesiologist, a nephrologist, and a transplant surgeon. We describe Alagille syndrome and our intraoperative management. To our knowledge, this is the first description of a combined liver-kidney transplant in an adult patient with Alagille syndrome.


Assuntos
Síndrome de Alagille , Hipertensão Pulmonar , Transplante de Rim , Adulto , Síndrome de Alagille/complicações , Síndrome de Alagille/cirurgia , Feminino , Humanos , Hipertensão Pulmonar/complicações , Rim
8.
Semin Cardiothorac Vasc Anesth ; 25(3): 173-184, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33356967

RESUMO

BACKGROUND: New or worsened mitral regurgitation (MR) is an uncommon yet serious complication after surgical aortic valve replacement (SAVR). While there have been numerous reports of its occurrence, there is little consensus regarding its presentation and management. This systematic review summarizes the evidence in the current literature surrounding new or worsened MR after SAVR and analyzes its potential implications. METHODS: Databases were examined for all articles and abstracts reporting on new or worsened MR after SAVR. Data collected included number of patients studied; patient characteristics; incidences of new or worsened MR; timing of diagnosis; and treatment. RESULTS: Thirty-six full-text citations were included in this review. The prevalence of new or worsened MR after SAVR was 8.4%. Sixteen percent of new MR occurrences were from an organic etiology, and 83% of new MR occurrences were that of a functional etiology. Most diagnoses were made in the late or unspecified postoperative period using echocardiography (range: 0 minutes to 18 years postoperatively). While no patients died from this complication, 7.7% of patients (16 out of 207) required emergent procedural re-intervention. CONCLUSIONS: This systematic review underscores the importance of identifying new or worsened MR following SAVR and accurate scoring of MR severity to guide treatment. It also outlines the associated clinical measures commonly documented following this complication, and the usefulness of transesophageal echocardiography for the detection of significant MR. These results reflect the current, limited state of the literature on this topic and warrant further investigation into MR detection and management strategies in SAVR patients.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/etiologia , Índice de Gravidade de Doença , Resultado do Tratamento
9.
Front Pharmacol ; 11: 566433, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33013404

RESUMO

Suggested treatment for active bleeding or invasive procedure prophylaxis has been described in the setting of end-stage liver disease (ESLD) in patients not receiving anticoagulation, and has included fresh frozen plasma (FFP), prothrombin complex concentrates (PCC), platelets, and cryoprecipitate. Today, the therapy for pharmacologically anticoagulated patients with ESLD presenting for liver transplant surgery remains controversial, poorly studied, and physician-dependent. We observed a variety of treatments administered at initiation of liver transplantation to correct acquired coagulopathy at our leading transplant center and present these cases. Three patients receiving preoperative therapeutic anticoagulation with warfarin for acute deep venous thrombosis and/or atrial fibrillation were transfused PCC, FFP, and/or cryoprecipitate for liver or liver-kidney transplant surgery. No thrombotic complications occurred, and one patient required reoperation for hemorrhage. We report data from these cases including estimated blood loss, presence of complications, duration of ICU stay, and length of hospitalization. Perioperative orthotopic liver transplant hematologic management and a review of relevant literature is presented.

10.
Pacing Clin Electrophysiol ; 42(12): 1552-1557, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31702059

RESUMO

BACKGROUND: The perioperative anesthesia care during subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is still evolving. OBJECTIVE: To assess the feasibility and safety of S-ICD implantation with monitored anesthesia care (MAC) versus general anesthesia (GA) in a tertiary care center. METHODS: This is a single-center retrospective study of patients undergoing S-ICD implantation between October 2012 and May 2019. Patients were categorized into MAC and GA group based on the mode of anesthesia. Procedural success without escalation to GA was the primary endpoint of the study, whereas intraprocedural hemodynamics, need of pharmacological support for hypotension and bradycardia, length of the procedure, stay in the post-anesthesia care unit, and postoperative pain were assessed as secondary endpoints. RESULTS: The study comprises 287 patients with MAC in 111 and GA in 176 patients. Compared to MAC, patients in GA group were younger and had a higher body mass index. All patients had successful S-ICD implantation. Only one patient (0.9%) in the MAC group was converted to GA. Despite a similar baseline heart rate (HR) and mean arterial blood pressure (MAP) in both groups, patients with GA had significantly lower HR and MAP during the procedure and more frequently required pharmacological hemodynamic support. Length of the procedure, stay in the postanesthesia care unit, and postoperative pain was similar in both groups. CONCLUSION: This retrospective experience suggests that implantation of S-ICD is feasible and safe with MAC. Use of GA is associated with more frequent administration of hemodynamic drugs during S-ICD implantation.


Assuntos
Anestesia/métodos , Desfibriladores Implantáveis , Implantação de Prótese/métodos , Anestesia Geral , Anestesia Local , Bradicardia/tratamento farmacológico , Estudos de Viabilidade , Feminino , Hemodinâmica , Humanos , Hipotensão/tratamento farmacológico , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/prevenção & controle , Estudos Retrospectivos
11.
Semin Cardiothorac Vasc Anesth ; 21(3): 245-251, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27837084

RESUMO

Anesthesia for orthotopic liver transplantation (OLT) is challenging for any anesthesiologist as the patients undergoing this procedure are among the most critically ill. Adding to the underlying complexity of OLT management is the rare complication of an intracardiac thrombus (ICT). Intracardiac thrombi can present following liver allograft reperfusion resulting in high morbidity and mortality. Currently there is no consensus treatment for ICT, and the gold standard for diagnosis is intraoperative transesophageal echocardiography (TEE); these 2 factors lead to a dangerous amalgam of the difficulty in diagnosing and treating the disease. We describe 2 separate cases in detail of ICT formation during OLT that were recognized and diagnosed with intraoperative TEE. These 2 cases highlight the important role of TEE in the management of ICT. A thorough literature review that follows analyzes our current understanding of ICT during OLT and the vital function of TEE by every anesthesiologists regardless of formal TEE training. Broader use of TEE during all OLTs can help narrow the anesthesiologist's differential diagnosis during the acute phases of transplantation and should be considered in all liver transplant surgeries.


Assuntos
Cardiopatias/diagnóstico por imagem , Transplante de Fígado/efeitos adversos , Trombose/diagnóstico por imagem , Adulto , Anestesia/métodos , Diagnóstico Diferencial , Ecocardiografia Transesofagiana/métodos , Feminino , Cardiopatias/patologia , Humanos , Complicações Intraoperatórias/diagnóstico por imagem , Transplante de Fígado/métodos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Trombose/patologia
13.
J Clin Anesth ; 31: 53-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27185678

RESUMO

BACKGROUND: The recently approved subcutaneous implantable cardioverter/defibrillator (S-ICD) uses a single extrathoracic subcutaneous lead to treat life-threatening ventricular arrhythmias, such as ventricular tachycardia and ventricular fibrillation. This is different from conventional transvenous ICDs, which are typically implanted under sedation. Currently, there are no reports regarding the anesthetic management of patients undergoing S-ICD implantation. STUDY OBJECTIVES: This study describes the anesthetic management and outcomes in patients undergoing S-ICD implantation and defibrillation threshold (DFT) testing. METHODS: The study population consists of 73 patients who underwent S-ICD implantation. General anesthesia (n = 69, 95%) or conscious/deep sedation (n = 4, 5%) was used for device implantation. MEASUREMENTS: Systolic blood pressure (SBP) and heart rate were recorded periprocedurally for S-ICD implantation and DFTs. Major adverse events were SBP <90 mm Hg refractory to vasopressor agents, significant bradycardia (heart rate <45 beats per minute) requiring pharmacologic intervention and, "severe" pain at the lead tunneling site and the S-ICD generator insertion site based on patient perception. INTERVENTIONS: Of the 73 patients, 39 had SBP <90 mm Hg (53%), and intermittent boluses of vasopressors and inotropes were administered with recovery of SBP. In 2 patients, SBP did not respond, and the patients required vasopressor infusion in the intensive care unit. MAIN RESULTS: Although the S-ICD procedure involved extensive tunneling and a mean of 2.5 ± 1.7 DFTs per patient, refractory hypotension was a major adverse event in only 2 patients. The mean baseline SBP was 132.5 ± 22.0 mm Hg, and the mean minimum SBP during the procedure was 97.3 ± 9.2 mm Hg (P < .01). There was also a mean 13-beats per minute decrease in heart rate (P < .01), but no pharmacologic intervention was required. Eight patients developed "severe" pain at the lead tunneling and generator insertion sites and were adequately managed with intravenous morphine. CONCLUSIONS: Among a heterogeneous population, anesthesiologists can safely manage patients undergoing S-ICD implantation and repeated DFTs without wide swings in SBP and with minimal intermittent pharmacologic support.


Assuntos
Anestesia Geral/métodos , Arritmias Cardíacas/terapia , Sedação Consciente/métodos , Desfibriladores Implantáveis , Implantação de Prótese/métodos , Adulto , Idoso , Arritmias Cardíacas/fisiopatologia , Pressão Sanguínea/fisiologia , Bradicardia/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/métodos , Feminino , Frequência Cardíaca/fisiologia , Humanos , Hipotensão/etiologia , Masculino , Pessoa de Meia-Idade , Dor/etiologia , Implantação de Prótese/efeitos adversos , Estudos Retrospectivos
14.
J Thorac Dis ; 7(12): 2139-50, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26793334

RESUMO

While many factors depend on successful implantation and outcome of left ventricular assist devices (LVAD), echocardiography remains an integral part and is vital to the success of this process. Transesophageal echocardiography (TEE) allows interrogation of all the cardiac structures and great vessels. The pre-implantation TEE exam establishes a baseline and may identify potential problems that need palliation. Among these, most significant are aortic insufficiency (AI), intracardiac thrombi, poor right ventricular (RV) function, and intracardiac shunts. The post-implantation exam allows for adequate de-airing of the heart and successful LVAD initiation. The position and flow profiles of the inflow and outflow cannulas of the LVAD may be assessed. Finally, it assists in the astute management and vigilant identification and correction of a number of complications in the immediate post-implantation period. TEE will continue to remain vital to the successful outcomes LVAD patients.

16.
J Clin Anesth ; 22(3): 201-4, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20400007

RESUMO

The McGRATH Video Laryngoscope Series 5 is an example of indirect laryngoscopic equipment. Experience using this device to safely intubate the trachea of awake and asleep patients with known or anticipated difficult airways is presented.


Assuntos
Neoplasias Ósseas/cirurgia , Queimaduras/cirurgia , Traumatismos Faciais/cirurgia , Laringoscópios , Adulto , Idoso de 80 Anos ou mais , Vértebras Cervicais/cirurgia , Criança , Clavícula , Desenho de Equipamento , Feminino , Humanos , Micrognatismo/etiologia , Pessoa de Meia-Idade , Neoplasias da Coluna Vertebral/secundário , Neoplasias da Coluna Vertebral/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...