Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 56
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 50(9): 2692-2698, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37058168

RESUMO

AIM: We performed a systematic survey to assess the existing gaps in Europe in multidisciplinary education for integration of radioligand therapy (RLT) into cancer care and to obtain detailed information on the current limitations and key contents relevant. METHODS: A high-quality questionnaire, with emphasis on survey scales, formulation, and validity of the different items, was designed. An expert validation process was undertaken. The survey was circulated among medical specialties involved in cancer treatment, universities, and nursing organizations. Questionnaires (156) were distributed, and 95 responses received. RESULTS: Sevety-eight percent of medical societies indicated that training in RLT was very important and 12% important. Eighty-eight percent indicated that their specialty training program included RLT. Twenty-six percent were satisfied with the existing structure of training in RLTs. Ninety-four percent indicated that the existing training is based on theory and hands-on experience. Main identified limitations were lack of centers ready to train and of personnel available for teaching. Sixty-five percent indicated that national programs could be expanded. Fifty percent of consulted universities indicated partial or scarce presence of RLT contents in their teaching programs. In 26% of the cases, the students do not have the chance to visit a RLT facility. A large majority of the universities are interested in further expansion of RLT contents in their curriculums. Nursing organizations almost never (44.4%) or occasionally (33.3%) include RLT contents in the education of nurses and technologists. Hands-on experience is almost never (38%) and sometimes (38%) offered. However, 67% of centers indicated high interest in expanding RLT contents. CONCLUSION: Centers involved recognize the importance of the training and indicate a need for inclusion of additional clinical content, imaging analysis, and interpretation as well as extended hands-on training. A concerted effort to adapt current programs and a shift towards multidisciplinary training programs is necessary for proper education in RLT in Europe.


Assuntos
Neoplasias , Humanos , Europa (Continente) , Inquéritos e Questionários , Neoplasias/radioterapia
2.
J Nucl Cardiol ; 30(2): 528-539, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-35799039

RESUMO

BACKGROUND: Cadmium-zinc-telluride (CZT)-based detectors exhibit higher diagnostic sensitivity in myocardial perfusion imaging (MPI) than conventional Anger-MPI for detection of coronary artery disease (CAD); however, reduced specificity and diagnostic accuracy of CZT-MPI were observed. This study aims to compare these different camera systems and to examine the degree of inter-rater reproducibility among readers with varying experience in MPI. METHODS: 83 patients who underwent double stress/rest examinations using both a CZT and conventional SPECT cameras within one visit were included. Anonymized and randomized MPI-images were distributed to 15 international readers using a standardized questionnaire. Subsequent coronary angiography findings of ten patients served as a reference for analysis of sensitivity and specificity. RESULTS: Image quality was significantly better in CZT-MPI with significantly lower breast attenuation (P < 0.05). CZT-MPI exhibited higher sensitivity than Anger-MPI (87.5% vs. 62.5%) and significantly reduced specificity (40% vs. 100%). Readers experienced with both camera systems had the highest inter-rater agreement indicating higher reproducibility (CZT 0.54 vs. conv. 0.49, P < 0.05). CONCLUSIONS: Higher diagnostic sensitivity of CZT-MPI offers advantages in detection of CAD yet potentially of at the cost of reduced specificity, therefore it requires special training and a differentiated evaluation approach, especially for non-experienced readers with such camera systems.


Assuntos
Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Reprodutibilidade dos Testes , Imagem de Perfusão do Miocárdio/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso
3.
Nuklearmedizin ; 61(4): 301-307, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35931063

RESUMO

AIM: to assess if the use of an audiovisual intervention in the uptake room and/or in the scanning room, could help to reduce anxiety during [18F]FDG PET/CT imaging. METHODS: We prospectively studied 120 patients referred for [18F]FDG PET/CT imaging. Patients were allocated in 4 groups of 30 patients depending on the use of the audiovisual intervention: (1) no audiovisual intervention; (2) audiovisual intervention only in the uptake room; (3) audiovisual intervention only in the scanning room; (4) audiovisual intervention in the uptake and the scanning rooms. In order to measure the anxiety levels of the patients before and after the scan, all patients answered the State-Trait Anxiety Inventory (STAI). RESULTS: The anxiety status across typical situations on a daily basis (STAI-T) of the 4 groups of patients was comparable with no significant differences. The mean State Anxiety (STAI-S) sum-score at prescan and postscan among groups was: (1) 17.5±8.7 vs. 17.3±8.6, p=0.834; (2) 17.4±10.5 vs. 15.8±9.6, p=0.110; (3) 17.5±11.7 vs. 15.1±9.8, p= 0.013; (4) 17.4±9.7 vs. 14.9±8.1, p= 0.009. The percentage of patients with reduction of the STAI-S score among groups 1-4 was 17%, 47%, 50%, and 66%, respectively. The variation of the percentage of patients with lower scores after intervention among groups was statistically significant (p<0.001). CONCLUSION: Audiovisual intervention decreases anxiety levels of patients referred for PET/CT imaging. The results of our study support a beneficial effect of the audiovisual intervention and its potential to alleviate the anxiety of oncological patients who undergo a PET/CT scan.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Ansiedade/diagnóstico por imagem , Humanos , Tomografia por Emissão de Pósitrons
4.
Melanoma Res ; 32(5): 334-342, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35703175

RESUMO

Although there is evidence that chemotherapy can have side effects on metabolism and brain function, there are few studies on the occurrence of these side effects with immunotherapy. The present study was conducted to assess whether brain metabolic changes occur in patients with malignant melanoma under immunotherapy. Thirty-nine patients after surgical intervention and with a diagnosis of malignant melanoma were retrospectively included and were divided into two groups: one group under the first-line therapy with anti-programmed cell death-1 ± anti-cytotoxic T lymphocyte antigen-4 monoclonal antibodies and the other group without any treatment after surgery, which served as a control. Basal and follow-up whole body and brain 2-[ 18 F]fluoro-2-deoxy-D-glucose ( 18 F]FDG) PET/computed tomography (CT) studies were performed. Changes in brain glucose metabolism after treatment initiation of the immunotherapy group were compared with the findings in the control group. In addition, longitudinal regression analysis to investigate whether the time under immunotherapy influenced the changes of brain metabolism was performed. None of the patients presented cognitive impairment or other neurological alterations between basal and follow-up brain [ 18 F]FDG PET/CT examinations. The statistical analysis revealed a significant relative SUV (SUVr)-loss in the left frontal region in patients of the immunotherapy group compared with the control group, with radjusted = -0.62 and P = 0.008. Severity of SUVr-loss was correlated with duration of treatment. Patients with disseminated malignant melanoma receiving immunotherapy may present a decrease of brain metabolism in the left frontal region, which is related with time-under-treatment, without any clinical evidence of neurological disorder.


Assuntos
Melanoma , Neoplasias Cutâneas , Encéfalo/patologia , Fluordesoxiglucose F18/uso terapêutico , Humanos , Imunoterapia/métodos , Melanoma/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/uso terapêutico , Estudos Retrospectivos , Neoplasias Cutâneas/tratamento farmacológico , Melanoma Maligno Cutâneo
5.
Semin Nucl Med ; 52(3): 302-311, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34836617

RESUMO

Positron emission tomography (PET) is a functional imaging technique introduced in 1970s. Over the years, PET was used alone but is in 2000 when the first hybrid PET/CT device was clinically introduced. Since then, PET has continuously been marked by technological developments, being the most recent one the introduction of silicon photomultipliers (SiPMs) as an alternative to standard photomultiplier tubes used in analog PET/CT systems. SiPMs, the basis for the so called digital PET/CT systems, are smaller than standard photomultiplier tubes (enabling higher spatial resolution) and provide up to 100% coverage of the crystal area, as well as high sensitivity, low noise, and fast timing resolution. SiPMs in combination with optimized acquisition and reconstruction parameters improve the localization of the annihilation events, provide high definition PET images, and offer higher sensitivity and higher diagnostic performance. This article summarizes the evidence about the superior performance of the state of the art digital PET and highlights its potential clinical implications. Digital PET opens new perspectives in the quantification and characterization of small lesions, which are mostly undetectable using analog PET systems, potentially changing patient management and improving outcomes in oncological and non-oncological diseases. Moreover, digital PET offers the possibility to reduce radiation dose and scan times which may facilitate the implementation of PET to address unmet clinical needs.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons/métodos
6.
JACC Cardiovasc Imaging ; 14(9): 1819-1828, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33454257

RESUMO

OBJECTIVES: This study sought to describe worldwide variations in the use of myocardial perfusion imaging hardware, software, and imaging protocols and their impact on radiation effective dose (ED). BACKGROUND: Concerns about long-term effects of ionizing radiation have prompted efforts to identify strategies for dose optimization in myocardial perfusion scintigraphy. Studies have increasingly shown opportunities for dose reduction using newer technologies and optimized protocols. METHODS: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study) registry, a multinational, cross-sectional study comprising 7,911 imaging studies from 308 labs in 65 countries. The study compared regional use of camera technologies, advanced post-processing software, and protocol characteristics and analyzed the influence of each factor on ED. RESULTS: Cadmium-zinc-telluride and positron emission tomography (PET) cameras were used in 10% (regional range 0% to 26%) and 6% (regional range 0% to 17%) of studies worldwide. Attenuation correction was used in 26% of cases (range 10% to 57%), and advanced post-processing software was used in 38% of cases (range 26% to 64%). Stress-first single-photon emission computed tomography (SPECT) imaging comprised nearly 20% of cases from all world regions, except North America, where it was used in just 7% of cases. Factors associated with lower ED and odds ratio for achieving radiation dose ≤9 mSv included use of cadmium-zinc-telluride, PET, advanced post-processing software, and stress- or rest-only imaging. Overall, 39% of all studies (97% PET and 35% SPECT) were ≤9 mSv, while just 6% of all studies (32% PET and 4% SPECT) achieved a dose ≤3 mSv. CONCLUSIONS: Newer-technology cameras, advanced software, and stress-only protocols were associated with reduced ED, but worldwide adoption of these practices was generally low and varied significantly between regions. The implementation of dose-optimizing technologies and protocols offers an opportunity to reduce patient radiation exposure across all world regions.


Assuntos
Cardiologia , Imagem de Perfusão do Miocárdio , Estudos Transversais , Humanos , Valor Preditivo dos Testes , Doses de Radiação , Software , Tecnologia , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X
7.
JACC Cardiovasc Imaging ; 14(3): 657-665, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32828783

RESUMO

OBJECTIVES: This study sought to establish worldwide and regional diagnostic reference levels (DRLs) and achievable administered activities (AAAs) for single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI). BACKGROUND: Reference levels serve as radiation dose benchmarks to compare individual laboratories against aggregated data, helping to identify sites in greatest need of dose reduction interventions. DRLs for SPECT MPI have previously been derived from national or regional registries. To date there have been no multiregional reports of DRLs for SPECT MPI from a single standardized dataset. METHODS: Data were submitted voluntarily to the INCAPS (International Atomic Energy Agency Nuclear Cardiology Protocols Study), a cross-sectional, multinational registry of MPI protocols. A total of 7,103 studies were included. DRLs and AAAs were calculated by protocol for each world region and for aggregated worldwide data. RESULTS: The aggregated worldwide DRLs for rest-stress or stress-rest studies employing technetium Tc 99m-labeled radiopharmaceuticals were 11.2 mCi (first dose) and 32.0 mCi (second dose) for 1-day protocols, and 23.0 mCi (first dose) and 24.0 mCi (second dose) for multiday protocols. Corresponding AAAs were 10.1 mCi (first dose) and 28.0 mCi (second dose) for 1-day protocols, and 17.8 mCi (first dose) and 18.7 mCi (second dose) for multiday protocols. For stress-only technetium Tc 99m studies, the worldwide DRL and AAA were 18.0 mCi and 12.5 mCi, respectively. Stress-first imaging was used in 26% to 92% of regional studies except in North America where it was used in just 7% of cases. Significant differences in DRLs and AAAs were observed between regions. CONCLUSIONS: This study reports reference levels for SPECT MPI for each major world region from one of the largest international registries of clinical MPI studies. Regional DRLs may be useful in establishing or revising guidelines or simply comparing individual laboratory protocols to regional trends. Organizations should continue to focus on establishing standardized reporting methods to improve the validity and comparability of regional DRLs.


Assuntos
Níveis de Referência de Diagnóstico , Tomografia Computadorizada de Emissão de Fóton Único , Estudos Transversais , Humanos , Perfusão , Valor Preditivo dos Testes , Doses de Radiação
8.
Nucl Med Commun ; 42(4): 421-428, 2021 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-33306635

RESUMO

AIM: To assess if digital PET/CT improves liver lesion detectability compared to analog PET/CT in patients with known or suspected liver metastases. MATERIALS AND METHODS: We prospectively included 83 cancer patients, with one or more of these conditions: history of liver metastases, clinical risk of having liver metastases or presence of suspected liver metastases on the first of the two PET/CTs. All patients were consecutively scanned on each PET/CT on the same day after a single [18F]fluorodeoxyglucose dose injection. The order of acquisition was randomly assigned. Three nuclear medicine physicians assessed both PET/CTs by counting the foci of high uptake suspicious of liver metastases. Findings were correlated with appropriate reference standards; 19 patients were excluded from the analysis due to insufficient lesion nature confirmation. The final sample consisted of 64 patients (34 women, mean age 68 ± 12 years). RESULTS: As per-patient analysis, the mean number of liver lesions detected by the digital PET/CT (3.84 ± 4.25) was significantly higher than that detected by the analog PET/CT (2.91 ± 3.31); P < 0.001. Fifty-five patients had a positive PET/CT study for liver lesions. In 26/55 patients (47%), the digital PET/CT detected more lesions; 7/26 patients (27%) had detectable lesions only by the digital system and had <10 mm of diameter. Twenty-nine patients had the same number of liver lesions detected by both systems. In nine patients both PET/CT systems were negative for liver lesions. CONCLUSION: Digital PET/CT offers improved detectability of liver lesions over the analog PET/CT in patients with known or suspected liver metastases.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Adulto , Idoso , Idoso de 80 Anos ou mais , Computadores , Computadores Analógicos , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Prospectivos , Compostos Radiofarmacêuticos
11.
Eur J Nucl Med Mol Imaging ; 47(3): 572-578, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31919634

RESUMO

OBJECTIVE: To compare detectability of hyperfunctioning parathyroid tissue (HPT) by digital and analog 18F-fluorocholine PET/CT in patients with primary hyperparathyroidism and negative/inconclusive 99mTc-MIBI scintigraphy-SPECT/CT. MATERIALS AND METHODS: Thirty-three patients with primary hyperparathyroidism and negative/inconclusive 99mTc-MIBI scintigraphy-SPECT/CT were prospectively included. All patients accepted to be scanned by digital and analog PET/CT in the same imaging session after a single injection of 18F-fluorocholine. Three nuclear medicine physicians evaluated the digital and analog PET/CT datasets to assess the detection rate of HPT. Maximum standard uptake values (SUVmax) of HPT and locoregional lymph nodes were measured in both systems. RESULTS: HPT was detected in 30/33 patients by the digital system, whereas it was detected in 22/33 patients by the analog system (p < 0.01). Moreover, in 21 of these 33 patients, both systems detected one focal 18F-fluorocholine uptake, and in one patient the digital system detected two foci. Histopathology demonstrated HPT in 32 patients and it was inconclusive in one patient. The digital PET/CT detected HPT in 29 of the 32 patients, and the analog system in 22 of the 32 (p < 0.01). All HPT suspected lesions resected and detected only by the digital system (n = 8) were < 10 mm (7.5 ± 1.3 mm), while those detected by both systems (n = 22) were > 10 mm (13 ± 3.8 mm). SUVmax of HPT lesions was significantly higher than SUVmax of locoregional lymph node independently of the PET/CT system used (4.5 ± 1.9 vs. 2.9 ± 1.3, p < 0.0001). CONCLUSIONS: Digital PET/CT offers superior performance over analog system in patients with suspected HPT and previous negative/inconclusive imaging examinations, particularly in sub-centimeter lesions. SUVmax can help in the differentiation between HTP and locoregional lymph nodes.


Assuntos
Hiperparatireoidismo Primário , Neoplasias das Paratireoides , Colina/análogos & derivados , Humanos , Glândulas Paratireoides , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tecnécio Tc 99m Sestamibi
13.
Eur J Nucl Med Mol Imaging ; 46(5): 1204, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30739142

RESUMO

The article Digital vs. analog PET/CT: intra-subject comparison of the SUVmax in target lesions and reference regions, written by Francisco Fuentes-Ocampo, Diego Alfonso López-Mora, Albert Flotats, Gabriela Paillahueque.

14.
Eur J Nucl Med Mol Imaging ; 46(8): 1745-1750, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30617960

RESUMO

PURPOSE: The purpose of this study was to assess whether digital photon counting technology in digital PET/CT influences the quantification of SUVmax in target lesions and regions of reference compared to analog PET/CT before an interchangeable use of either system in follow up studies. METHODS: From January to June of 2018, 100 oncological patients underwent successive PET/CT imaging with digital and analog systems in the same day. Fifty-eight patients underwent analog imaging first and digital imaging thereafter, and 42 patients the other way round. SUVmax was measured in reference regions (liver and mediastinal blood pool) and in the most metabolically active target lesion in each patient. According to the sequence order of PET/CT acquisition, two groups of SUVmax values were obtained, i.e. group 1: analog PET/CT performed first; group 2: digital PET/CT performed first. RESULTS: Mean SUVmax in the total sample (regardless of the order of PET/CT acquisition) in the target lesions with the analog PET/CT was 8.14 ± 6.39 and the digital 9.97 ± 6.14 (P = 0.000). Total mean SUVmax in the liver with the analog was 4.39 ± 2.59 and the digital 4.46 ± 3.18 (P = 0.477). Total mean SUVmax in the mediastinal blood pool with the analog was 2.30 ± 0.67 and the digital 2.54 ± 0.74 (P = 0.000). Group 1: mean SUVmax in the target lesions with the analog system was 6.64 ± 4.71 and the digital 9.48 ± 5.60 (P = 0.000). Mean liver SUVmax with the analog was 4.70 ± 2.90 and the digital 4.80 ± 3.72 (P = 0.088). Mediastinal blood pool SUVmax with the analog was 2.33 ± 0.66 and the digital 2.45 ± 0.73 (P = 0.041). Group 2: mean SUVmax in target lesions with the digital system was 10.63 ± 6.88 and the analog 10.16 ± 7.76 (P = 0.046). Mean liver SUVmax with the digital was 3.99 ± 2.20 and the analog 3.96 ± 2.04 (P = 0.218). Mediastinal blood pool SUVmax with the digital was 2.66 ± 0.75 and the analog 2.27 ± 0.68 (P = 0.000). No significant differences between both time delays were found. CONCLUSIONS: Improved photon counting technology in the digital PET/CT, and the effect of delayed increased uptake and retention significantly increases SUVmax values. This has to be taken into account before interchangeable use of either system in follow up studies.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Idoso , Interpretação Estatística de Dados , Feminino , Humanos , Processamento de Imagem Assistida por Computador/normas , Fígado/diagnóstico por imagem , Masculino , Mediastino/diagnóstico por imagem , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Compostos Radiofarmacêuticos/farmacocinética , Padrões de Referência , Reprodutibilidade dos Testes
15.
Eur J Nucl Med Mol Imaging ; 46(6): 1383-1390, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30631910

RESUMO

OBJECTIVE: The purpose of this study was to compare image quality and lesion detection capability between a digital and an analog PET/CT system in oncological patients. MATERIALS AND METHODS: One hundred oncological patients (62 men, 38 women; mean age of 65 ± 12 years) were prospectively included from January-June 2018. All patients, who accepted to be scanned by two systems, consecutively underwent a single day, dual imaging protocol (digital and analog PET/CT). Three nuclear medicine physicians evaluated image quality using a 4-point scale (-1, poor; 0, fair; 1, good; 2, excellent) and detection capability by counting the number of lesions with increased radiotracer uptake. Differences were considered significant for a p value <0.05. RESULTS: Improved image quality in the digital over the analog system was observed in 54% of the patients (p = 0.05, 95% CI, 44.2-63.5). The percentage of interrater concordance in lesion detection capability between the digital and analog systems was 97%, with an interrater measure agreement of κ = 0.901 (p < 0.0001). Although there was no significant difference in the total number of lesions detected by the two systems (digital: 5.03 ± 10.6 vs. analog: 4.53 ± 10.29; p = 0.7), the digital system detected more lesions in 22 of 83 of PET+ patients (26.5%) (p = 0.05, 95% CI, 17.9-36.7). In these 22 patients, all lesions detected by the digital PET/CT (and not by the analog PET/CT) were < 10 mm. CONCLUSION: Digital PET/CT offers improved image quality and lesion detection capability over the analog PET/CT in oncological patients, and even better for sub-centimeter lesions.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Idoso de 80 Anos ou mais , Diagnóstico por Computador , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Compostos Radiofarmacêuticos
16.
Clin Nucl Med ; 44(1): e1-e5, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30325816

RESUMO

OBJECTIVE: Normalization to an appropriate reference region in F-FDG PET imaging may enhance diagnostic performance in Huntington disease (HD). We aimed to identify stable brain areas that could be used to model neurometabolic degeneration in HD correlating imaging (SUVrvalues at the basal ganglia [BBGG]) and clinical parameters (disease burden score [DBS]). MATERIALS AND METHODS: We performed brain F-FDG PET/CT in 38 manifest HD patients (meanage ± SD, 54 ± 14.3 years; CAGrepeats ± SD, 44.2 ± 3.1), 20 premanifest HD patients (meanage ± SD, 42.7 ± 11.7 years; CAGrepeats ± SD, 40 ± 3.8), and 18 healthy controls (NC; meanage ± SD, 45 ± 13.2 years). For quantitative analysis, we selected (a) defined reference regions from the Montreal Neurological Institute space atlas (pons, whole cerebellum, cerebral white matter, thalamus, and a pons-cerebellar vermis region of interest), and (b) reference clusters obtained by voxelwise statistical comparison across groups (P < 0.05 FWE; extent voxel threshold k = 200). Each candidate reference region and reference cluster was quantitatively assessed using imaging and clinical parameters. RESULTS: Comparing HD and NC groups, we obtained a reference cluster in the cerebellum, and in temporal and frontal lobes. Comparing manifest HD and premanifest HD patients, we observed reference clusters in the cerebellum, pons, thalamus, parietal lobe, and cuneus. The set of reference regions showed a significant correlation between SUVrvalues at the BBGG and DBS in all HD patients. In premanifest HD patients, the correlation between SUVrvalues at the BBGG and DBS was significant using the pons-cerebellar vermis region of interest, the thalamus as defined reference regions, and the pons and thalamus as reference clusters. In manifest HD patients, the correlation was significant using the temporal and white matter frontal lobe clusters. Variance between SUVrvalues in the set of reference regions and reference clusters was minimal within NC. CONCLUSIONS: The pons may be a stable and reliable region to calculate SUVrvalues to model the neurometabolic degeneration in quantitative F-FDG PET imaging in HD.


Assuntos
Doença de Huntington/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Feminino , Fluordesoxiglucose F18 , Humanos , Doença de Huntington/patologia , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Padrões de Referência
19.
Heart Lung Circ ; 26(1): 25-34, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27425184

RESUMO

BACKGROUND: There is concern about radiation exposure with radionuclide myocardial perfusion imaging (MPI). This sub-study of the International Atomic Energy Agency (IAEA) Nuclear Cardiology Protocols Study reports radiation doses from MPI, and use of dose-optimisation protocols in Australia and New Zealand (ANZ), and compares them with data from the rest of the world. METHODS: Data were collected from 7911 MPI studies performed in 308 laboratories worldwide in one week in 2013, including 439 MPI studies from 34 ANZ laboratories. For each laboratory, effective radiation dose (ED) and a quality index (QI) score (out of 8) based on pre-specified "best practices" was determined. RESULTS: In ANZ patients, ED ranged from 0.9-17.9 milliSievert (mSv). Median ED was similar in ANZ compared with the rest of the world (10.0 (IQR: 6.5-11.7) vs. 10.0 (IQR 6.4-12.6, P=0.15), as were mean QI scores (5.5±0.7 vs. 5.4±1.3, P=0.84). Use of stress-only imaging (17.6% vs. 31.8% of labs, P=0.09) and weight-based dosing of technetium-99m (14.7% vs. 30.3%, P=0.07) was lower in ANZ compared with the rest of the world but this difference was not statistically significant. Median ED was significantly lower in metropolitan versus non-metropolitan laboratories (10.1 mSv vs. 11.6 mSv, P<0.01), although mean QI scores were similar (5.4±0.8 vs. 5.5±0.7, P=0.75). CONCLUSION: Across ANZ, there is variability in ED from MPI, and use of radiation safety practices, particularly between metropolitan and non-metropolitan laboratories. Overall, ANZ laboratories have a similar median ED to laboratories in the rest of the world.


Assuntos
Imagem de Perfusão do Miocárdio/efeitos adversos , Doses de Radiação , Exposição à Radiação , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oceania
20.
Eur J Nucl Med Mol Imaging ; 43(4): 718-28, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26686336

RESUMO

PURPOSE: Nuclear cardiology is widely used to diagnose coronary artery disease and to guide patient management, but data on current practices, radiation dose-related best practices, and radiation doses are scarce. To address these issues, the IAEA conducted a worldwide study of nuclear cardiology practice. We present the European subanalysis. METHODS: In March 2013, the IAEA invited laboratories across the world to document all SPECT and PET studies performed in one week. The data included age, gender, weight, radiopharmaceuticals, injected activities, camera type, positioning, hardware and software. Radiation effective dose was calculated for each patient. A quality score was defined for each laboratory as the number followed of eight predefined best practices with a bearing on radiation exposure (range of quality score 0 - 8). The participating European countries were assigned to regions (North, East, South, and West). Comparisons were performed between the four European regions and between Europe and the rest-of-the-world (RoW). RESULTS: Data on 2,381 European patients undergoing nuclear cardiology procedures in 102 laboratories in 27 countries were collected. A cardiac SPECT study was performed in 97.9 % of the patients, and a PET study in 2.1 %. The average effective dose of SPECT was 8.0 ± 3.4 mSv (RoW 11.4 ± 4.3 mSv; P < 0.001) and of PET was 2.6 ± 1.5 mSv (RoW 3.8 ± 2.5 mSv; P < 0.001). The mean effective doses of SPECT and PET differed between European regions (P < 0.001 and P = 0.002, respectively). The mean quality score was 6.2 ± 1.2, which was higher than the RoW score (5.0 ± 1.1; P < 0.001). Adherence to best practices did not differ significantly among the European regions (range 6 to 6.4; P = 0.73). Of the best practices, stress-only imaging and weight-adjusted dosing were the least commonly used. CONCLUSION: In Europe, the mean effective dose from nuclear cardiology is lower and the average quality score is higher than in the RoW. There is regional variation in effective dose in relation to the best practice quality score. A possible reason for the differences between Europe and the RoW could be the safety culture fostered by actions under the Euratom directives and the implementation of diagnostic reference levels. Stress-only imaging and weight-adjusted activity might be targets for optimization of European nuclear cardiology practice.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Tomografia por Emissão de Pósitrons/métodos , Guias de Prática Clínica como Assunto , Doses de Radiação , Técnicas de Imagem Cardíaca/efeitos adversos , Técnicas de Imagem Cardíaca/instrumentação , Técnicas de Imagem Cardíaca/normas , Cardiologia/organização & administração , União Europeia , Medicina Nuclear/organização & administração , Tomografia por Emissão de Pósitrons/efeitos adversos , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/normas , Sociedades Científicas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...