Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Metrologia ; 54(5): 730-737, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29056763

RESUMO

A value for the Boltzmann constant was measured electronically using an improved version of the Johnson Noise Thermometry (JNT) system at the National Institute of Standards and Technology (NIST), USA. This system is different from prior ones, including those from the 2011 determination at NIST and both 2015 and 2017 determinations at the National Institute of Metrology (NIM), China. As in all three previous determinations, the main contribution to the combined uncertainty is the statistical uncertainty in the noise measurement, which is mitigated by accumulating and integrating many weeks of cross-correlated measured data. The second major uncertainty contribution also still results from variations in the frequency response of the ratio of the measured spectral noise of the two noise sources, the sense resistor at the triple-point of water and the superconducting quantum voltage noise source. In this paper, we briefly describe the major differences between our JNT system and previous systems, in particular the input circuit and approach we used to match the frequency responses of the two noise sources. After analyzing and integrating 49 days of accumulated data, we determined a value: k = 1.380 642 9(69)×10-23 J/K with a relative standard uncertainty of 5.0×10-6 and relative offset -4.05×10-6 from the CODATA 2014 recommended value.

2.
Phys Rev Lett ; 112(1): 013602, 2014 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-24483898

RESUMO

In this Letter we study a system consisting of two nearly degenerate mechanical modes that couple to a single mode of an optical cavity. We show that this coupling leads to nearly complete (99.5%) hybridization of the two mechanical modes into a bright mode that experiences strong optomechanical interactions and a dark mode that experiences almost no optomechanical interactions. We use this hybridization to transfer energy between the mechanical modes with 40% efficiency.

3.
Phys Rev Lett ; 98(9): 096804, 2007 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-17359186

RESUMO

We measure the noise added by an atomic point contact operated as a displacement detector. With a microwave technique, we increase the measurement speed of atomic point contacts by a factor of 500. The measurement is then fast enough to detect the resonant motion of a nanomechanical beam at frequencies up to 60 MHz and sensitive enough to observe the random thermal motion of the beam at 250 mK. We demonstrate a shot-noise limited imprecision of 2.3 fm/square root[Hz] and observe a 78 aN/square root[Hz] backaction force, yielding a total uncertainty in the beam's displacement that is 42 times the standard-quantum limit.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA