Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Biomed Anal ; 146: 420-425, 2017 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-28934694

RESUMO

A simple, fast, sensitive and effective pass/fail field-friendly method has been developed for detecting sildenafil in suspect Viagra and unapproved tablets using handheld Raman spectrometers and silver colloids. The method involves dissolving a portion of a tablet in water followed by filtration and addition of silver colloids, resulting in a solution that can be measured directly through a glass vial. Over one hundred counterfeit Viagra and unapproved tablets were examined on three different devices during the method development phase of the study. While the pass/fail approach was found to be 92.6% effective on average, the efficacy increased to 97.4% on average when coupled with the software's "Discover Mode" feature that allows the user to compare a suspect spectrum to that of a stored sildenafil spectrum. The lowest concentration of sildenafil in a water/colloid solution that yielded a "Pass" was found to be 7.6µg/mL or 7.6 parts per million (ppm). For the analysis of suspect tablets, this value was found to be as low as 10µg/mL and as high as 625µg/mL. This variability was likely related to the tablet formulation, e.g., concentration of sildenafil, presence and concentration of water-soluble and/or water-insoluble ingredients. However, since most counterfeit Viagra and unapproved tablets contain >50mg sildenafil per tablet, such low concentrations will not be encountered often. Limited in-lab and in-field validation studies were conducted in which analysts/field agents followed the procedure outlined in this study for small sample sets. These individuals were provided with written instructions, a ∼20min demonstration regarding how to perform the procedure and use the instrument, and a kit with field-friendly supplies (purified bottled water from a local grocery store, disposable plastic pipettes, eye-dropper with a silver colloid solution, etc.). The method proved to be 98.3% and 91.7% effective for the in-lab and in-field validation studies, respectively, which demonstrated the ruggedness, simplicity and practicality of the method.


Assuntos
Citrato de Sildenafila/química , Prata/química , Comprimidos/análise , Comprimidos/química , Química Farmacêutica/métodos , Solubilidade , Análise Espectral Raman/métodos
2.
J Chromatogr Sci ; 53(1): 38-46, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24668043

RESUMO

A considerable number of erectile dysfunction products, and dietary supplements suspected of containing phosphodiesterase-5 (PDE-5) inhibitors, have been analyzed by the US Food and Drug Administration. Often these samples are found to contain the approved active pharmaceutical ingredients (APIs) such as sildenafil, tadalafil or vardenafil. However, analogs of these APIs have also been identified in many samples and products containing multiple PDE-5 inhibitors have also been found. A single high-performance liquid chromatography with ultraviolet detection method has been developed for the determination of sildenafil, tadalafil, vardenafil and a number of commonly encountered analogs in pharmaceutical dosage forms and dietary supplement products, including tablets, capsules, bulk powders, troches and liquids. This method was designed as an alternative to methods developed for the determination of a single PDE-5 inhibitor. Using this protocol, 14 PDE-5 inhibitor compounds can be separated and determined in a single analysis.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Preparações Farmacêuticas/química , Inibidores da Fosfodiesterase 5/química , Cromatografia Líquida de Alta Pressão/instrumentação , Estrutura Molecular
3.
J Forensic Sci ; 57(5): 1313-7, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22564183

RESUMO

Consumer complaints received by the U.S. Food and Drug Administration in August 2010 about raw organic almonds tasting "bitter" opened an investigation into the presence of bitter almonds in the imported product. Bitter almonds (Prunus amygdalus) contain the cyanogenic glucoside amygdalin, which hydrolyzes to produce cyanide. Ultraviolet-visible spectrophotometry was used to detect and quantitate cyanide, and liquid chromatography-mass spectrometry was utilized to detect amygdalin in the submitted samples. Control bitter almonds were found to contain 1.4 mg cyanide/g and an estimated level of 20-25 mg amygdalin/g. The questioned samples contained between 14 and 42 µg cyanide/g and were positive for the presence of amygdalin. Sweet almonds were found to be negative for both compounds, at levels of detection of 4 µg cyanide/g and 200 µg amygdalin/g.

4.
J Pharm Biomed Anal ; 59: 50-7, 2012 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-22055930

RESUMO

During routine screenings of two "libido enhancer" dietary supplements using LC-MS(n), two compounds were detected that displayed structural similarities to tadalafil. These compounds were isolated from the supplements using high-performance liquid chromatography with fraction collection, and were characterized further using accurate mass determination and NMR. "Compound 1" had an m/z of 434 for the [M+H]⁺ ion, with a corresponding chemical formula of C24H24N3O5. "Compound 2" had an m/z of 432 for the [M+H]⁺ ion, with a corresponding chemical formula of C25H26N3O4. Although mass spectrometry indicated that these modifications occurred in place of the -CH3 found on the pyrazinopyridoindole-1,4-dione of tadalafil, NMR was required to elucidate the correct configurations of these substitutions. The data obtained using NMR indicated that the structure of the -C3H7O moiety found in Compound 1 was 2-hydroxypropyl, and the -C4H9 in Compound 2 was n-butyl. These new analogs were given the names 2-hydroxypropylnortadalafil and n-butylnortadalafil, respectively.


Assuntos
Benzodioxóis/isolamento & purificação , Carbolinas/isolamento & purificação , Suplementos Nutricionais/análise , Suplementos Nutricionais/normas , Contaminação de Medicamentos , Inibidores da Fosfodiesterase 5/isolamento & purificação , Benzodioxóis/química , Carbolinas/química , Cromatografia Líquida de Alta Pressão , Contaminação de Medicamentos/legislação & jurisprudência , Espectroscopia de Ressonância Magnética , Espectrometria de Massas , Estrutura Molecular , Inibidores da Fosfodiesterase 5/química , Tadalafila
5.
J Pharm Biomed Anal ; 50(2): 228-31, 2009 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-19427155

RESUMO

Phosphodiesterase type 5 (PDE-5) inhibitors represent a class of drugs used primarily in the treatment of erectile dysfunction. Currently, three PDE-5 inhibitors have been approved by the U.S. Food and Drug Administration (FDA) for use in the United States: sildenafil citrate, tadalafil, and vardenafil hydrochloride trihydrate. A bulk material, labeled as an ingredient for a dietary supplement, was analyzed for the presence of PDE-5 inhibitors. The compound that was detected displayed structural similarities to sildenafil, and was characterized further using LC-MS(n), FTICRMS, X-ray crystallography and NMR. The compound was given the name sulfoaildenafil. When compared to sildenafil, sulfoaildenafil contains a sulfur atom substitution for the oxygen atom in the pyrazolopyrimidine portion of the molecule, and a 3,5-dimethyl substitution on the piperazine ring, rather than the 4-methyl moiety. The X-ray crystallographic data indicate that the material in this sample is comprised of two polymorphs, which may affect the chemical and/or biological properties of any product formulated with this compound.


Assuntos
Inibidores de Fosfodiesterase/química , Piperazinas/química , Sulfonas/química , Cromatografia Líquida , Cristalografia por Raios X , Espectroscopia de Ressonância Magnética , Espectrometria de Massas , Modelos Moleculares , Estrutura Molecular , Purinas/química , Citrato de Sildenafila
6.
J Pharm Biomed Anal ; 36(3): 525-33, 2004 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-15522526

RESUMO

A liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method was developed to screen for the presence of synthetic phosphodiesterase type 5 (PDE-5) inhibitors including sildenafil, tadalafil and vardenafil. The method was applied to the analysis of dietary supplements and bulk herbal materials. Bulk powders or composites of tablets, capsules or liquids were prepared and an extraction of PDE-5 inhibitors was performed using a mixture of acetonitrile and water with sonication. Identification of sildenafil, vardenafil or tadalafil was accomplished using a single quadrupole mass spectrometer coupled to a liquid chromatograph with an electrospray interface. Positive ion detection in the full scan mode was used while in-source collision induced dissociation (CID) provided several structurally significant fragment ions to aid in the mass spectral identification. Approximately half of the 40 botanical products analyzed were found to contain undeclared synthetic PDE-5 inhibitors. For products found to contain one of these three compounds by LC-MS, HPLC with UV detection was used for quantitation.


Assuntos
Suplementos Nutricionais/análise , Inibidores de Fosfodiesterase/análise , Diester Fosfórico Hidrolases , Preparações de Plantas/análise , Espectrometria de Massas por Ionização por Electrospray/métodos , 3',5'-GMP Cíclico Fosfodiesterases , Cromatografia Líquida/métodos , Nucleotídeo Cíclico Fosfodiesterase do Tipo 5 , Espectrometria de Massas/métodos , Inibidores de Fosfodiesterase/síntese química , Diester Fosfórico Hidrolases/metabolismo , Preparações de Plantas/química , Espectrofotometria Ultravioleta/métodos
7.
Electrophoresis ; 24(22-23): 4116-27, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14661238

RESUMO

Recent developments in the characterization of antibiotics are reviewed. Many capillary electrophoretic techniques have been utilized in their analyses, addressing various aspects of quantifying, profiling, and monitoring. Laser-induced fluorescence detection systems demonstrated their usefulness in clinical settings and in the monitoring of residue levels in food matrices. Different sample introduction methods have been explored, enhancing detection sensitivity, or reducing or eliminating sample manipulation prior to injection.


Assuntos
Aminoglicosídeos/farmacocinética , Antraciclinas/farmacocinética , Antibacterianos/farmacocinética , Sulfonamidas/farmacocinética , Aminoglicosídeos/sangue , Aminoglicosídeos/urina , Animais , Antraciclinas/sangue , Antraciclinas/urina , Antibacterianos/sangue , Antibacterianos/urina , Eletroforese Capilar , Humanos , Pomadas/análise , Sulfonamidas/sangue , Sulfonamidas/urina , Comprimidos/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...