Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Front Med (Lausanne) ; 9: 900073, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35814751

RESUMO

Background and Aims: Monitoring of acute or chronic response to beta-blockers in patients with liver cirrhosis is based on the measurement of the HVPG. Our aim was to evaluate the response to beta-blockers with non-invasive techniques. Patients and Methods: This is a prospective observational study. Consecutive patients with an indication of primary or secondary prophylaxis of variceal bleeding who did not meet exclusion criteria were included. Acute response and chronic response were evaluated. Baseline and after acute and chronic response hepatosplenic measurements of TE and ARFI were obtained. Contrast-enhanced Doppler ultrasound was performed before and after acute and chronic responses. Results: From June 2015 to May 2018, 55 patients (14 with exclusion criteria) were included. We analyzed 41 patients, mean age 57 (SD: 8), 82.9% men, alcohol 43.9%, children A/B/C 78%/17.1%/4.9%, and 87.8% on primary prophylaxis. In all, the acute response was performed and was positive in 68.3% (CI 95: 55-85%). The chronic response was performed in 30 (73.2%) and was positive in 36.7% (CI 95: 18-55%). Basal measurements significantly related to acute response were spleen TE [responders 58.4 (SD: 23.0) KPa vs. non-responders 75 (SD: 0) KPa; p = 0.02] and damping index [non-responders 0.96 (0.8) vs. responders 0.44 (0.4), p = 0.01], and with chronic response, the spleen TE [responders 58.1 (SD: 21.4) KPa vs. non-responders 73.2 (SD: 5.5) KPa; p = 0.02], and damping index [non-chronic responders 0.8 (0.7) vs. chronic responders 0.4 (0.4), p = 0.04]. A spleen TE ≥ 74 KPa had a high sensitivity of 100% and specificity of 60% and a high NPV100% for predicting poor acute response to beta-blockers. The damping index > 0.6 showed moderate sensitivity of 67% and specificity of 69% with a high NPV of 82% for predicting poor acute response to beta-blockers. The combination of both measurements for predicting poor acute response to beta-blockers had an AUC of 0.8 (CI 95: 0.5-0.9). A spleen TE ≥ 74 KPa had a high sensitivity of 87% and specificity of 71% with a high NPV of 71% for predicting poor chronic response to beta-blockers. A damping index > 0.6 had moderate sensitivity of 60%, specificity of 82%, and NPV of 56% for predicting poor chronic response to beta-blockers. The combination of both measurements for predicting poor chronic response to beta-blockers had an AUC of 0.8 (CI 95: 0.7-0.9). Conclusion: Spleen TE and damping index can identify a subgroup of patients with poor acute or chronic response to beta-blockers.

2.
Ultrasound J ; 12(1): 54, 2020 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-33369713

RESUMO

BACKGROUND: COVID-19 infection has been associated with a high rate of thrombotic events, such as deep vein thrombosis (DVT) and acute pulmonary embolism (APE). METHODS: The purpose of our retrospective study was to evaluate the prevalence of asymptomatic DVT in lower limbs in critically ill COVID-19 patients (n = 23) with severe respiratory failure and high levels of D-dimer by bedside Doppler ultrasound (DU). RESULTS: DVT was diagnosed in 14 cases (60.87%), 5 in proximal venous territory and 9 in infrapopliteal veins. Computed Tomography Pulmonary Angiography (CTPA) was performed in six patients and all of them showed acute pulmonary embolism (APE) at segmental or subsegmental branches of pulmonary arteries. These patients (APE or DVT confirmed) were treated with therapeutic doses of anticoagulant therapy. CONCLUSION: In critically COVID-19 ill ICU patients with severe respiratory failure and elevated D-dimer, the incidence of asymptomatic DVT is high. We propose that DU allows detection of DVT in asymptomatic patients, adding a factor that may balance the decision to fully anticoagulate these patients.

3.
Ultrasound Med Biol ; 44(11): 2171-2182, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30076031

RESUMO

Sinusoidal obstruction syndrome, also known as veno-occlusive disease (SOS/VOD), is a potentially life-threatening complication that can develop after hematopoietic cell transplantation. Clinically, SOS/VOD is characterized by hepatomegaly, right upper quadrant pain, jaundice and ascites, most often occurring within the first 3 wk after hematopoietic cell transplantation. Early therapeutic intervention is pivotal for survival in SOS/VOD. Thus, a rapid and reliable diagnosis has to be made. Diagnosis of SOS/VOD is based on clinical criteria, such as the Seattle, Baltimore or recently issued European Society for Blood and Marrow Transplantation criteria, to which hemodynamic and/or ultrasound evidence of SOS were added for the first time. However, to rule out major differential diagnoses and to verify the diagnosis, a reliable imaging method is needed. Ultrasound techniques have been proposed in SOS/VOD. Nevertheless, the sensitivity and specificity of transabdominal ultrasound and Doppler techniques need to be improved. Innovative ultrasound methods such as a combination of Doppler ultrasound with shear wave elastography and contrast-enhanced ultrasound techniques should be evaluated for diagnosis and follow-up of SOS/VOD. The goals of this review are to discuss currently available ultrasound techniques and to identify areas for future studies in SOS/VOD.


Assuntos
Hepatopatia Veno-Oclusiva/diagnóstico por imagem , Fígado/diagnóstico por imagem , Humanos , Ultrassonografia/métodos
4.
Ultrasound Int Open ; 4(1): E2-E15, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29423461

RESUMO

"How to perform contrast-enhanced ultrasound (CEUS)" provides general advice on the use of ultrasound contrast agents (UCAs) for clinical decision-making and reviews technical parameters for optimal CEUS performance. CEUS techniques vary between centers, therefore, experts from EFSUMB, WFUMB and from the CEUS LI-RADS working group created a discussion forum to standardize the CEUS examination technique according to published evidence and best personal experience. The goal is to standardise the use and administration of UCAs to facilitate correct diagnoses and ultimately to improve the management and outcomes of patients.

5.
BJR Case Rep ; 3(1): 20150342, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-30363305

RESUMO

We report a case of torsion of a wandering spleen in an 18-year-old male patient who presented with acute abdominal pain and left lower quadrant mass. The patient was initially misdiagnosed at another institution. The patient came to our hospital for further investigation. Contrast-enhanced ultrasound was performed and showed a solid hypoechoic avascular mass, which was all that remained of the spleen, located under the left kidney. Based on the ultrasound findings, CT scan and MRI of the abdomen were performed to confirm the suspicion of torsion of a wandering spleen. To the best of our knowledge, there are no case reports describing the use of contrast-enhanced ultrasound for diagnosing torsion of a wandering spleen.

6.
Biomed Res Int ; 2015: 517369, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26609528

RESUMO

BACKGROUND: Liver disease associated with cystic fibrosis (CFLD) is the second cause of mortality in these patients. The diagnosis is difficult because none of the available tests are specific enough. Noninvasive elastographic techniques have been proven to be useful to diagnose hepatic fibrosis. Acoustic radiation force impulse (ARFI) imaging is an elastography imaging system. The purpose of the work was to study the utility of liver and spleen ARFI Imaging in the detection of CFLD. Method. 72 patients with cystic fibrosis (CF) were studied and received ARFI imaging in the liver and in the spleen. SWV values were compared with the values of 60 healthy controls. Results. Comparing the SWV values of CFLD with the control healthy group, values in the right lobe were higher in patients with CFLD. We found a SWV RHL cut-off value to detect CFLD of 1.27 m/s with a sensitivity of 56.5% and a specificity of 90.5%. CF patients were found to have higher SWC spleen values than the control group. Conclusions. ARFI shear wave elastography in the right hepatic lobe is a noninvasive technique useful to detect CFLD in our sample of patients. Splenic SWV values are higher in CF patients, without any clinical consequence.


Assuntos
Fibrose Cística/patologia , Técnicas de Imagem por Elasticidade/métodos , Hepatopatias/patologia , Fígado/patologia , Baço/patologia , Adolescente , Criança , Pré-Escolar , Fibrose Cística/diagnóstico por imagem , Feminino , Humanos , Lactente , Fígado/diagnóstico por imagem , Hepatopatias/diagnóstico por imagem , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Baço/diagnóstico por imagem
7.
Pediatr Radiol ; 45(9): 1316-22, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25796383

RESUMO

BACKGROUND: Portal hypertension, a major complication of hepatic fibrosis, can affect the stiffness of the spleen. OBJECTIVE: To suggest normal values of spleen stiffness determined by acoustic radiation force impulse imaging in healthy children and to compare measurements using two different US probes. MATERIALS AND METHODS: In a prospective study, 60 healthy children between 1 day and 14 years of age were assigned to four age groups with 15 children in each. Measurements were performed using two transducers (convex 4C1 and linear 9L4), and 10 measurements were obtained in each child, 5 with each probe. RESULTS: The mean splenic shear wave velocities were 2.17 m/s (SD 0.35, 95% CI 2.08-2.26) with the 4C1 probe and 2.15 m/s (SD 0.23, 95% CI 2.09-2.21) with the 9L4 probe (not significant). CONCLUSION: We found normal values for spleen stiffness with no difference in the mean values obtained using two types of US transducers, but with higher variability using a convex compared to a linear transducer.


Assuntos
Envelhecimento/fisiologia , Módulo de Elasticidade/fisiologia , Técnicas de Imagem por Elasticidade/instrumentação , Baço/diagnóstico por imagem , Baço/fisiologia , Transdutores , Adolescente , Criança , Pré-Escolar , Técnicas de Imagem por Elasticidade/normas , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência ao Cisalhamento/fisiologia , Espanha , Estresse Mecânico
8.
Ultrasound Med Biol ; 40(3): 470-7, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24361222

RESUMO

Acoustic radiation force impulse (ARFI) is an image-guided ultrasound elastography method that allows quantification of liver stiffness by measurement of shear wave velocity. One purpose of the work described in this article was to determine the normal liver stiffness values of healthy children using ARFI with two different probes, 4 C1 and 9 L4. Another purpose was to evaluate the effects of site of measurement, age, gender and body mass index on liver stiffness values. This prospective study included 60 healthy children (newborn to 14 y) divided into four age groups. One thousand two hundred ARFI measurements were performed, that is, 20 measurements per patient (5 measurements in each lobe, with each probe). Means, standard deviations (SD) and confidence intervals for velocity were calculated for each hepatic lobe and each probe in each age group and for the whole group. Mean shear wave velocity measured in the right lobe was 1.19 ± 0.04 m/s (SD = 0.13) with the 4 C1 transducer and 1.15 ± 0.04 m/s (SD = 0.15) with the 9 L4 transducer. Age had a small effect on shear wave measurements. Body mass index and sex had no significant effects on ARFI values, whereas site of measurement had a significant effect, with lower ARFI values in the right hepatic lobe. ARFI is a non-invasive technique that is feasible to perform in children with both the 4 C1 and 9 L4 probes. The aforementioned velocity values obtained in the right lobe may be used as reference values for normal liver stiffness in children.


Assuntos
Envelhecimento/fisiologia , Técnicas de Imagem por Elasticidade/instrumentação , Técnicas de Imagem por Elasticidade/métodos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Fígado/diagnóstico por imagem , Fígado/fisiologia , Adolescente , Criança , Pré-Escolar , Módulo de Elasticidade/fisiologia , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores Sexuais , Estresse Mecânico
9.
J Clin Ultrasound ; 41(8): 493-500, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23744551

RESUMO

PURPOSE: To describe the contrast-enhanced ultrasound (CEUS) features of liver and biliary lesions related to hepatic artery thrombosis in adult patients with orthotopic liver transplantation. METHODS: Gray-scale ultrasound (US), Doppler US, and CEUS using a hexafluoride-based US contrast media were performed on a series of eight patients with liver transplantation and hepatic artery thrombosis. RESULTS: Six of the cases presented infarctions, seen as parenchymal geographic areas of lack of enhancement. Biliary necrosis, seen as nonenhancing periportal cuff, was seen in one case. Infected biloma, seen as a nonenhancing hilar collection, was present in two cases. Infarction and biloma coexisted in one patient. Two abscesses were seen as a late complication in one case. One of them was seen as a typical necrotic abscess with a central nonenhancing area and peripheral rim enhancement higher than the surrounding liver. The other one was seen as a partially liquefied abscess. CONCLUSION: CEUS was useful to diagnose lesions related to hepatic artery thrombosis in liver transplantation. It enabled distinguishing between them and to define their size and extension better than conventional gray-scale US.


Assuntos
Meios de Contraste , Hepatopatias/diagnóstico por imagem , Transplante de Fígado , Trombose/diagnóstico por imagem , Abscesso/diagnóstico por imagem , Adulto , Feminino , Artéria Hepática/diagnóstico por imagem , Humanos , Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Infarto/diagnóstico por imagem , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Necrose/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Retrospectivos , Ultrassonografia Doppler em Cores/métodos
10.
Abdom Imaging ; 37(4): 639-46, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21792579

RESUMO

Imaging is required if complication is suspected in acute pyelonephritis to assess the nature and extent of the lesions, and to detect underlying causes. The current imaging modality of choice in clinical practice is computed tomography. Because of associated radiation and potential nephrotoxicity, CEUS is an alternative that has been proven to be equally accurate in the detection of acute pyelonephritis renal lesions. The aims of this study of 48 patients are to describe in detail the CEUS findings in acute pyelonephritis, and to determine if abscess and focal pyelonephritis may be distinguished. Very characteristic morphologic and temporal patterns of enhancement are described. These allow differentiation of focal pyelonephritis from renal abscess, and detection of tiny suppurative foci within focal pyelonephritis. The detection of abscesses is important because follow-up in 25 patients revealed a longer clinical course. Typical pyelonephritis CEUS features permit distinction from other renal lesions. As a whole, CEUS is an excellent tool in the work-up of complicated acute pyelonephritis, so it may be considered as the imaging technique of choice in the evaluation and follow-up of these patients who frequently are very young, so as to minimise radiation exposure.


Assuntos
Aumento da Imagem , Pielonefrite/diagnóstico por imagem , Abscesso/diagnóstico por imagem , Doença Aguda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Nefropatias/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Ultrassonografia , Adulto Jovem
11.
J Ultrasound Med ; 30(11): 1593-8, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22039033

RESUMO

We report quantitative liver acoustic radiation force impulse (ARFI) elastographic findings in 2 cases of sinusoidal obstructive syndrome and liver contrast-enhanced sonographic features in one of these cases. To our knowledge, findings in this condition from these techniques have not been reported previously. Acoustic radiation force impulse elastography showed median high shear wave velocities (case 1, 2.75 m/s; case 2, 2.58 m/s) that normalized after specific treatment for sinusoidal obstructive syndrome; therefore, ARFI elastography provided quantitative information that helped diagnose this condition as well as monitor the response to treatment. Contrast-enhanced sonographic findings in one of the cases showed patchy liver enhancement that correlated with the high-velocity patchy distribution on ARFI elastography in that case and enhanced multidetector row computed tomographic findings in the other case. This contrast-enhanced sonographic pattern progressively normalized during follow-up after specific treatment. The elastographic features in both cases and contrast-enhanced sonographic features in one of them contributed to early diagnosis and follow-up of sinusoidal obstructive syndrome in both patients. Further prospective studies are necessary to define the role of ARFI elastography and contrast-enhanced sonography in the early diagnosis and clinical follow-up of this condition.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Hepatopatia Veno-Oclusiva/diagnóstico por imagem , Acústica , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade
12.
Rev Esp Cardiol ; 58(10): 1233-5, 2005 Oct.
Artigo em Espanhol | MEDLINE | ID: mdl-16238993

RESUMO

Use of the radial artery for cardiac catheterization has significantly reduced the incidence and severity of complications at the access site. Nevertheless, occasionally unusual complications or atypical responses to treatment are observed. We describe two cases: a radial artery pseudoaneurysm that was unresponsive to compression treatment and a foreign-body inflammatory reaction at the radial artery access site. The characteristics, development and treatment of the 2 cases are described, and the pathogenic mechanisms are discussed.


Assuntos
Falso Aneurisma/etiologia , Cateterismo Cardíaco/efeitos adversos , Reação a Corpo Estranho/etiologia , Artéria Radial , Cateterismo Cardíaco/métodos , Humanos , Masculino , Pessoa de Meia-Idade
13.
Rev. esp. cardiol. (Ed. impr.) ; 58(10): 1233-1235, oct. 2005. ilus
Artigo em Es | IBECS | ID: ibc-041255

RESUMO

El uso de la vía transradial para el cateterismo cardíaco ha reducido drásticamente la incidencia y la gravedad de las complicaciones relacionadas con el acceso. No obstante, en ocasiones se producen complicaciones inusuales o cuya respuesta al tratamiento es atípica. Describimos 2 casos: un seudoaneurisma radial refractario al tratamiento compresivo y una reacción inflamatoria a cuerpo extraño en el lugar de la punción arterial. Se ilustran ambos casos, se detallan su evolución y tratamiento y se discute su mecanismo patogénico


Use of the radial artery for cardiac catheterization has significantly reduced the incidence and severity of complications at the access site. Nevertheless, occasionally unusual complications or atypical responses to treatment are observed. We describe two cases: a radial artery pseudoaneurysm that was unresponsive to compression treatment and a foreign-body inflammatory reaction at the radial artery access site. The characteristics, development and treatment of the 2 cases are described, and the pathogenic mechanisms are discussed


Assuntos
Masculino , Pessoa de Meia-Idade , Humanos , Cateterismo Cardíaco/efeitos adversos , Artéria Radial/fisiopatologia , Reação a Corpo Estranho/fisiopatologia , Infarto do Miocárdio/complicações
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...