Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
Nefrologia (Engl Ed) ; 2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38679516

RESUMO

INTRODUCTION: New generation helixone dialyzers has recently been developed as part of the ongoing effort to improve dialyzer hemocompatibility and avoid adverse reactions to synthetic dialyzers. This study aimed to assess the performance and albumin loss of this new dialyzer series in hemodiafiltration and compare it with the previous generation helixone series. MATERIAL AND METHODS: A prospective study was conducted in 19 patients. Each patient underwent eight dialysis sessions with the same routine dialysis parameters; only the dialyzer varied: FX60 CorDiax, FX CorAL 60, FX600 CorDiax, FX CorAL 600, FX80 CorDiax, FX CorAL 80, FX800 CorDiax, and FX CorAL 800. The reduction ratios (RR) of urea, creatinine, ß2-microglobulin, myoglobin, kappa-free immunoglobulin light chains (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda immunoglobulin light chains (λFLC), and albumin were compared intra-individually. Dialysate albumin loss was also measured. RESULTS: All treatments were well tolerated. The mean amount of replacement fluid ranged from 31 to 34 L. Comparison of dialysis treatments showed no differences between small molecules and even up to those the size of ß2-microglobulins. Little differences were found between myoglobin, κFLC, prolactin, α1-microglobulin, and λFLC RRs, and only FX80 CorDiax was slightly superior to the others. Mean dialysate albumin losses were similar, with less than 2.5 g lost in each dialyzer. The FX80 CorDiax showed slightly higher global removal scores than the other dialyzers evaluated, except for FX CorAL 800. CONCLUSION: The new generation helixone dialyzers series has been updated to minimise the risk of adverse reactions, while maintaining the effectiveness and albumin loss achieved by the previous most advanced helixone generation.

3.
Artif Organs ; 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38404240

RESUMO

BACKGROUND: New versions of the polyester polymer alloy (PEPA) membrane have appeared over the years, with increases in both the pore size and the amount of polyvinylpyrrolidone (PVP) to optimize hydrophilicity performance. This study aimed to assess the efficacy of the most recently developed PEPA dialyzer, the FDY series, in hemodialysis (HD) modality in terms of uremic toxin removal and albumin loss and to compare it with that of several high-flux dialyzers currently used in HD and post-dilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out in 21 patients. All patients underwent six dialysis sessions with the same routine dialysis parameters; only the dialyzer and/or the dialysis modality varied: FX80 in HD, FDY 180 in HD, Clearum HS17 in HDF, Elisio 19H in HDF, Vitapes 180 in HDF, and FX80 in post-dilution HDF. The reduction ratios (RR) of urea, creatinine, ß2 -microglobulin, myoglobin, κFLC, prolactin, α1 -microglobulin, α1 -acid glycoprotein, λFLC, and albumin were compared intraindividually. Dialysate albumin loss was also measured. RESULTS: Both membranes FDY and FX80 are high-flux dialyzers and are applied here in high-flux HD. The average RR of ß2 -microglobulin was slightly lower in the two HD treatments than in the HDF treatments. Comparison of dialysis treatments revealed that the PEPA FDY dialyzer in the HD modality was more effective than the FX80 dialyzer in high-flux HD and was as effective as post-dilution HDF, especially in terms of myoglobin, κFLC, prolactin, α1 -microglobulin, and λFLC RRs. The FDY treatments obtained similar albumin RR in blood and slightly higher dialysate albumin loss, although the values were clinically acceptable. CONCLUSIONS: The most recently developed PEPA dialyzers in the HD modality were as effective as all treatments in the HDF modality and were clearly superior to high-flux helixone HD treatment. These results confirm that this dialyzer should be categorized within the medium cut-off (MCO) membrane classification.

5.
J Vasc Access ; : 11297298231204552, 2023 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-37936372

RESUMO

BACKGROUND: Autologous arteriovenous fistula is usually the vascular access of choice for hemodialysis in patients with chronic kidney disease. Autologous forearm loops with cephalic or basilic vein are an alternative in those cases with a suitable forearm vein but with an unsuitable radial artery; however they are rarely used and there is little reported evidence of their usefulness. Our objective is to report our results on the creation of autogenous forearm loops as vascular access for hemodialysis. METHODS: We present a prospective cohort study of autogenous forearm loop arteriovenous fistula created between 2010 and 2022, in patients with stage 4-5 chronic kidney disease. Demographic data, surgical details, vein used, follow up to 24 months, maturation, utilization, primary, assisted, and secondary patency estimations with Kaplan-Meier curves, as well as complications during follow-up, were recorded. RESULTS: During the study period, 22 autologous forearm loops were created, 14 of them with cephalic, and 8 with basilic vein. Most (59%) of the patients were men, 19 were already on dialysis and the rest started during follow-up. Sixteen patients had previous vascular accesses. One patient was lost during follow-up. Six-week maturation rate was 61.9% and utilization rate was 57.1%. 6, 12, and 24 months primary and secondary patencies were 75.4%, 59.2%, 41.5% and 85.0%, 69.5%, 56.9% respectively. In five patients an access-induced distal ischemia was diagnosed, four successfully treated and only one patient lost the access. No cases of infection or other major complications were reported. CONCLUSION: Autologous forearm loops have acceptable maturation (61.9%) and patency rates at follow-up (56.9% 2-years secondary patency). Although rarely used, they are a vascular access alternative that should be considered to preserve the proximal vasculature of the arm for future accesses.

6.
Nefrología (Madrid) ; 43(6): 750-756, nov.- dec. 2023. graf, tab
Artigo em Espanhol | IBECS | ID: ibc-228013

RESUMO

Introducción El gradiente de sodio durante las sesiones es uno de los factores clave en el balance de este ion en los pacientes en hemodiálisis; sin embargo, hasta la aparición de los nuevos monitores con módulos de sodio, las diferencias entre el sodio prescrito y el medido han sido poco estudiadas. El objetivo del presente estudio fue comparar el impacto del cambio del monitor 5008 Cordiax al nuevo monitor 6008 Cordiax sobre los resultados de la conductividad real medida, del sodio plasmático inicial y final. Material y métodos Se incluyeron 106 pacientes en hemodiálisis. Cada paciente recibió dos sesiones de diálisis en las que solo se varió el monitor. Las variables recogidas fueron: el concentrado, sodio y bicarbonato prescritos, conductividad real, sodio plasmático inicial y final medidos por dialisancia iónica y se calculó el cambio de la concentración de sodio plasmático durante el tratamiento o delta de sodio (ΔPNa). Resultados El cambio de monitor de diálisis mostró pequeñas diferencias, aunque significativas, en el sodio plasmático inicial (138,14 mmol/L con 5008 vs. 138,81 mmol/L con 6008) y final (139,58 mmol/L vs. 140,97 mmol/L), así como en la conductividad real obtenida (13,97 vs. 14,10 mS/cm). El ΔPNa también aumento significativamente. Conclusión El cambio de monitor 5008 a 6008 se asocia a un aumento en la conductividad, un sodio plasmático más elevado y un incremento en el ΔPNa. El conocer y confirmar este cambio permitirá individualizar la prescripción de sodio, evitar posibles efectos indeseables y podría ser el estudio preliminar para explorar el nuevo biosensor de control de sodio incorporado en la nueva generación de monitores (AU)


Introduction The sodium gradient during hemodialysis sessions is one of the key factors in sodium balance in patients with dialysis-dependent chronic kidney disease; however, until the appearance of the new monitors with sodium modules, the differences between prescribed and measured sodium have been understudied. The present study aimed to compare the impact on the measured conductivity and the initial and final plasma sodium after changing the 5008 Cordiax to the new 6008 Cordiax monitor. Material and methods 106 patients on hemodialysis were included. Each patient underwent 2 dialysis sessions in which only the monitor was varied. The variables collected were dialysate, sodium and bicarbonate prescribed, real conductivity, initial and final plasma sodium measured, and the calculated sodium gradient (ΔPNa). Results The change of dialysis monitor showed small but statistically significant differences in the initial (138.14 mmol/L with 5008 vs. 138.81 mmol/L with 6008) and final plasma sodium (139.58 mmol/L vs. 140.97 mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1 mS/cm). The ΔPNa also increased significantly. Conclusión The change from 5008 to 6008 monitor is associated with increased conductivity, leading the patient to end the sessions with higher plasma sodium and ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription and avoid possible undesirable effects. It could be the preliminary study to explore the new sodium biosensor incorporated into the new generation of monitors (AU)


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Soluções para Hemodiálise/química , Insuficiência Renal Crônica/terapia , Sódio/sangue , Sódio/metabolismo , Técnicas Biossensoriais
7.
Eur J Vasc Endovasc Surg ; 66(6): 849-854, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37659740

RESUMO

OBJECTIVE: Inflow arterial aneurysms are a rare but serious complication after long term arteriovenous fistulae (AVF), probably due to arterial wall remodelling after an increase in flow and shear stress, and kidney transplantation with immunosuppressive therapy. This study aimed to describe the outcomes of surgical treatment and long term follow up in a large cohort. METHODS: This prospective cohort study collected data from patients with a true inflow artery aneurysm after AVF creation that was surgically repaired between 2010 and 2022. Anastomotic and infected aneurysms or post-puncture pseudoaneurysms were excluded. Demographic data, access characteristics, symptoms, treatment strategies, and long term follow up were recorded; patency was estimated using Kaplan-Meier survival analysis. RESULTS: During the study period, 28 patients (64% men, mean age 60.1 years) were treated surgically for aneurysmal degeneration of the axillary or brachial (n = 23) or radial (n = 5) artery after an AVF (10 distal, 18 proximal) performed a mean of 18.3 ± SD 7.9 years previously. Most AVFs were ligated or thrombosed, while all patients except one had previously received kidney transplants. Most of the cases (n = 18) were symptomatic: 13 with pain or swelling, four with distal embolisation, and one rupture. They were repaired by aneurysm partial excision and graft interposition (11 great saphenous vein, six ipsilateral basilic vein, three cephalic vein, and two PTFE graft), ligation (n = 3), or direct end to end anastomosis (n = 3). No major complications occurred before discharge, after a mean hospital stay of 2.4 days. After a mean follow up of 4.8 ± 3.3 years, three cases presented complications: two recurrent proximal brachial aneurysms were repaired with an additional proximal interposition graft (one with further late infected pseudoaneurysm) and an asymptomatic post-traumatic graft thrombosis. Five year primary and secondary patency was 84% and 96%, respectively. CONCLUSION: Aneurysmal degeneration of the inflow artery is an unusual complication during long term follow up of AVFs. Aneurysm excision and, in general, autogenous graft interposition using the saphenous or ipsilateral arm vein is a safe and effective strategy.


Assuntos
Aneurisma , Fístula Arteriovenosa , Derivação Arteriovenosa Cirúrgica , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Diálise Renal/efeitos adversos , Aneurisma/diagnóstico por imagem , Aneurisma/etiologia , Aneurisma/cirurgia , Artérias/cirurgia , Veia Safena/cirurgia , Grau de Desobstrução Vascular , Estudos Retrospectivos , Artéria Braquial/cirurgia
8.
Am J Nephrol ; 54(7-8): 291-298, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37311444

RESUMO

INTRODUCTION: Adherence to a low-sodium (Na) diet is crucial in patients under hemodialysis, as it improves cardiovascular outcomes and reduces thirst and interdialytic weight gain. Recommended salt intake is lower than 5 g/day. The new 6008 CAREsystem monitors incorporate a Na module that offers the advantage of estimating patients' salt intake. The objective of this study was to evaluate the effect of dietary Na restriction for 1 week, monitored with the Na biosensor. METHODS: A prospective study was conducted in 48 patients who maintained their usual dialysis parameters and were dialyzed with a 6008 CAREsystem monitor with activation of the Na module. Total Na balance, pre-/post-dialysis weight, serum Na (sNa), changes in pre- to post-dialysis sNa (ΔsNa), diffusive balance, and systolic and diastolic blood pressure were compared twice, once after 1 week of patients' usual Na diet and again after another week with more restricted Na intake. RESULTS: Restricted Na intake increased the percentage of patients on a low-Na diet (<85 Na mmol/day) from 8% to 44%. Average daily Na intake decreased from 149 ± 54 to 95 ± 49 mmol, and interdialytic weight gain was reduced by 460 ± 484 g per session. More restricted Na intake also decreased pre-dialysis sNa and increased both intradialytic diffusive balance and ΔsNa. In hypertensive patients, reducing daily Na by more than 3 g Na/day lowered their systolic blood pressure. CONCLUSIONS: The new Na module allowed objective monitoring of Na intake, which in turn could permit more precise personalized dietary recommendations in patients under hemodialysis.


Assuntos
Cloreto de Sódio na Dieta , Sódio , Humanos , Estudos Prospectivos , Diálise Renal/métodos , Dieta Hipossódica , Pressão Sanguínea , Aumento de Peso
9.
Clin Kidney J ; 16(5): 859-867, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37151418

RESUMO

Background: A key feature of dialysis treatment is the prescription of dialysate sodium (Na). This study aimed to describe the practical implementation of a new automated dialysate Na control biosensor and to assess its tolerance and the beneficial clinical effects of isonatraemic dialysis. Methods: A prospective study was carried out in 86 patients who, along with their usual parameters, received the following five consecutive phases of treatment for 3 weeks each: phase 0: baseline 5008 machine; phases 1 and 2: 6008 machine without activation of the Na control biosensor and the same fixed individualized Na dialysate prescription or adjusted to obtain similar conductivity to phase 0; phases 3 and 4: activated Na control to isonatraemic dialysis (Na dialysate margins 135-141 or 134-142 mmol/L). Results: When the Na control was activated, the few episodes of cramps or hypotension disappeared when the lower dialysate Na margin was increased by 1 or 2 mmol/L. The activated Na control module showed significant differences compared with baseline and the non-activated Na module in final serum Na values, diffusive Na balance, and changes in pre- to postdialysis plasma Na values. The mean predialysis systolic blood pressure value was significantly lower in phase 4 than in phase 1. There were no significant differences in total Na balance in the four 6008 phases evaluated. Conclusions: The implementation of the automated dialysate Na control module is a useful new tool, which reduced the diffusive load of Na with good tolerance. The module had the advantages of reducing thirst, interdialytic weight gain and intradialytic plasma Na changes.

10.
J Vasc Access ; 24(1): 155-157, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34121498

RESUMO

The following paper reports the case of a woman on in-center hemodialysis through an arteriovenous graft, who attended with an acute vascular access thrombosis. Post percutaneous thrombectomy, the patient presented a rare case of self-limited acute hepatitis secondary to the revascularization procedure. We explain the probable trigger for this complication, its pathophysiology, management, and evolution.


Assuntos
Derivação Arteriovenosa Cirúrgica , Hepatite , Trombose , Feminino , Humanos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/cirurgia , Grau de Desobstrução Vascular , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Trombectomia/efeitos adversos , Trombose/diagnóstico por imagem , Trombose/etiologia , Trombose/cirurgia , Diálise Renal/efeitos adversos , Hepatite/complicações , Resultado do Tratamento , Estudos Retrospectivos
11.
Blood Purif ; 52(1): 68-74, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35551384

RESUMO

INTRODUCTION: The medium cut-off Elisio HX dialyzer by Nipro became commercially available in Europe in 2021, but there are still no reports of in vivo data. This study aimed to evaluate the safety and efficacy of it compared with previously evaluated hemodialysis (HD), expanded HD (HDx), and postdilution hemodiafiltration (HDF) treatments. METHODS: A prospective study was carried out on 18 patients who underwent 5 dialysis sessions: FX80 Cordiax in HD, Elisio H19 in HD, Elisio HX19 in HDx, Theranova 400 in HDx, and FX80 Cordiax in HDF. The reduction ratios of urea, creatinine, ß2-microglobulin, myoglobin, kappa FLC, prolactin, α1-microglobulin, α1-acid glycoprotein, lambda FLC, and albumin were compared. Dialysate albumin loss was measured. RESULTS: The comparison between the different dialysis modalities revealed no difference for small molecules, but HDx and HDF were significantly more efficient than HD for medium and large molecule removal. The efficacy of Elisio HX19 dialyzer in HDx was similar to the Theranova 400, superior to both dialyzers in HD, and slightly lower than HDF. Albumin losses in dialysate with HD dialyzers were less than 1 g, but between 1.5 and 2.5 g in HDx and HDF. The global removal score (GRS) values with HDx treatments were statistically significantly higher than those with HD. The highest GRS was obtained with the helixone dialyzer in HDF. CONCLUSIONS: The new MCO dialyzer, Elisio HX, performs with excellent behavior and tolerance. It represents an upgrade compared to their predecessor and is very close to the removal capacity of HDF treatment.


Assuntos
Hemodiafiltração , Diálise Renal , Humanos , Estudos Prospectivos , Hemodiafiltração/efeitos adversos , Albuminas , Soluções para Diálise
13.
Nefrologia (Engl Ed) ; 43(6): 750-756, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38242765

RESUMO

INTRODUCTION: The sodium gradient during hemodialysis sessions is one of the key factors in sodium balance in patients with dialysis-dependent chronic kidney disease; however, until the appearance of the new monitors with sodium modules, the differences between prescribed and measured sodium have been understudied. The present study aimed to compare the impact on the measured conductivity and the initial and final plasma sodium after changing the 5008 Cordiax to the new 6008 Cordiax monitor. MATERIAL AND METHODS: 106 patients on hemodialysis were included. Each patient underwent 2 dialysis sessions in which only the monitor was varied. The variables collected were dialysate, sodium and bicarbonate prescribed, real conductivity, initial and final plasma sodium measured, and the calculated sodium gradient (ΔPNa). RESULTS: The change of dialysis monitor showed small but statistically significant differences in the initial (138.14mmol/L with 5008 vs. 138.81mmol/L with 6008) and final plasma sodium (139.58mmol/L vs. 140.97mmol/L), as well as in the actual conductivity obtained (13.97 vs. 14.1mS/cm). The ΔPNa also increased significantly. CONCLUSION: The change from 5008 to 6008 monitor is associated with increased conductivity, leading the patient to end the sessions with higher plasma sodium and ΔPNa. Knowing and confirming this change will allow us to individualize the sodium prescription and avoid possible undesirable effects. It could be the preliminary study to explore the new sodium biosensor incorporated into the new generation of monitors.


Assuntos
Diálise Renal , Sódio , Humanos , Diálise Renal/efeitos adversos , Soluções para Diálise
14.
Clin Kidney J ; 15(12): 2292-2299, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36381368

RESUMO

Background: Recently, several pharmaceutical companies have developed new medium cut-off (MCO) dialyzers for expanded hemodialysis (HDx). This study aimed to compare the safety and efficacy of four MCO dialyzers, against each other and versus high-flux hemodialysis (HD) and post-dilution hemodiafiltration (HDF). Methods: A prospective study was carried out on 23 patients who underwent six dialysis sessions: two sessions with the FX80 Cordiax in HD and HDF, and four HDx sessions with the Phylther 17-SD, Vie-18X, Elisio HX19 and Theranova 400 dialyzers. The reduction ratios (RRs) of urea, creatinine, ß2-microglobulin, myoglobin, kappa free immunoglobulin light chain (κFLC), prolactin, α1-microglobulin, α1-acid glycoprotein, lambda (λFLC) and albumin were compared. Dialysate albumin loss was also measured. Results: The differences in efficacy between the evaluated dialyzers were minimal in small molecules and even up to the size of ß2-microglobulin. The main differences were found between myoglobin, κFLC, prolactin, α1-microglobulin and λFLC RRs, in which all four MCO dialyzers, with similar efficacy, were clearly superior to HD and slightly inferior to HDF treatment. Albumin losses in the dialysate with HD dialyzers were <1 g and between 1.5 and 2.5 g in HDx and HDF. The global removal score values were similar in all four HDx treatments, and again significantly higher than those with HD. Conclusions: The results of the four MCO dialyzers evaluated in this study showed good efficiency, with no significant performance differences between them while being completely safe in terms of albumin loss. Likewise, the study confirms the superiority of HDx over high-flux HD with an efficacy close to that of post-dilution HDF.

15.
Clin Kidney J ; 15(10): 1946-1951, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36158145

RESUMO

Background: Both metabolic acidosis and alkalosis increase hospitalizations, haemodynamic instability and mortality in haemodialysis patients. Unfortunately, current practices opt for a one-size-fits-all approach, leaving many patients either acidotic before or alkalotic after dialysis sessions. Therefore an individualized adjustment of these patients' dialysate bicarbonate prescriptions could reduce these acid-base imbalances. Methods: This is a prospective single-cohort study of patients on a chronic haemodiafiltration programme. The dialysate bicarbonate prescription was modified according to the pre- and post-dialysis total carbon dioxide (TCO2) values of 19-25 mEq/L and ≤29 mEq/L, respectively, with an adjustment formula calculated with the data obtained from previously published work by our group. In addition, we analysed this adjustment's effect on plasma sodium, potassium, phosphorus, parathyroid hormone (PTH) and calcium. Results: At baseline, only 67.9% of patients were within the desired pre- and post-dialysis TCO2 target range. As of the first month, every followed patient met the TCO2 target range objective in pre-dialysis measurements and ˃95% met the post-dialysis TCO2 target. At the end of the study, 75% of the patients were on dialysate bicarbonate of 32-34 mEq/L. There were no clinically significant changes in calcium, phosphate, PTH, sodium or potassium levels. Also, we did not notice any increase in intradialytic adverse events. Conclusions: We suggest an individualized adjustment of the dialysate bicarbonate concentration according to the pre- and post-dialysis TCO2 values. With it, nearly every patient in our cohort reached the established range, potentially reducing their mortality risk.

17.
Blood Purif ; 51(1): 38-46, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-33789268

RESUMO

INTRODUCTION: Haemodialysis (HD) allow depuration of uraemic toxins by diffusion, convection, and adsorption. Online haemodiafiltration (HDF) treatments add high convection to enhance removal. There are no prior studies on the relationship between convection and adsorption in HD membranes. The possible benefits conferred by intrinsic adsorption on protein-bound uraemic toxins (PBUTs) removal are unknown. METHODS: Twenty-two patients underwent their second 3-days per week HD sessions with randomly selected haemodialysers (polysulfone, polymethylmethacrylate, cellulose triacetate, and polyamide copolymer) in high-flux HD and HDF. Blood samples were taken at the beginning and at the end of the treatment to assess the reduction ratio (RR) in a wide range of molecular weight uraemic toxins. A mid-range removal score (GRS) was also calculated. An elution protocol was implemented to quantify the amount of adsorbed mass (Mads) for each molecule in every dialyser. RESULTS: All synthetic membranes achieved higher RR for all toxins when used in HDF, specially the polysulfone haemodialyser, resulting in a GRS = 0.66 ± 0.06 (p < 0.001 vs. cellulose triacetate and polyamide membranes). Adsorption was slightly enhanced by convection for all membranes. The polymethylmethacrylate membrane showed expected substantial adsorption of ß2-microglobulin (MadsHDF = 3.5 ± 2.1 mg vs. MadsHD = 2.1 ± 0.9 mg, p = 0.511), whereas total protein adsorption was pronounced in the cellulose triacetate membrane (MadsHDF = 427.2 ± 207.9 mg vs. MadsHD = 274.7 ± 138.3 mg, p = 0.586) without enhanced PBUT removal. DISCUSSION/CONCLUSION: Convection improves removal and slightly increases adsorption. Adsorbed proteins do not lead to enhanced PBUTs depuration and limit membrane efficiency due to fouling. Selection of the correct membrane for convective therapies is mandatory to optimize removal efficiency.


Assuntos
Hemodiafiltração/instrumentação , Membranas Artificiais , Toxinas Urêmicas/isolamento & purificação , Adsorção , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Uremia/terapia , Toxinas Urêmicas/sangue
19.
Nefrología (Madrid) ; 41(5): 556-565, sep.-oct. 2021. tab, ilus
Artigo em Espanhol | IBECS | ID: ibc-227935

RESUMO

Introducción: Los pacientes en hemodiálisis (HD) suelen tener una condición física mermada y elevado sedentarismo. La consolidación de programas de ejercicio físico en las unidades de diálisis está limitada por barreras como la seguridad inherente a estos programas y la falta de recursos. Objetivos: Evaluar la eficacia y seguridad en la implantación de un programa de ejercicio físico intradiálisis (EFI) sobre la condición física de los pacientes con un equipo multidisciplinar (fisioterapeuta y auxiliares de enfermería). Material y métodos: Estudio cuasiexperimental pre-post unicéntrico prospectivo de 6 meses en 34 pacientes. Intervención con EFI combinado 2 días a la semana, evaluándose de forma basal y final la capacidad cardiorrespiratoria (6MWT), fuerza muscular (HG, dinamometría de cuádriceps y 10STS), la composición corporal (bioimpedanciometría) y la capacidad coordinativa (Timed Up and Go test). La seguridad se valoró registrando las incidencias relacionadas con el acceso vascular, la estabilidad hemodinámica y el perfil de rellenado vascular (RBV) durante las sesiones. También se registró la adherencia al programa así como parámetros analíticos habituales. Resultados: La adherencia al programa de EFI fue elevada (70,8%). Se constató una mejora significativa de 47m (p<0,001) en el 6MWT; un incremento medio de 1,6kg (p=0,007) en el HG para la fuerza de extremidades superiores y en las extremidades inferiores (10STS p=0,003; dinamometría p<0,05). Respecto a la seguridad, no se detectaron incidencias ni diferencias significativas en el RBV. Conclusiones: Un programa de EFI combinado favorece la mejora de la condición física de los pacientes en HD sin comprometer la seguridad del tratamiento. Es aconsejable un equipo multidisciplinar para implantar y dar continuidad eficazmente a un programa de EFI. (AU)


Introduction: Patients undergoing hemodialysis (HD) are characterized by a poor physical condition and a substantial sedentary profile. The implementation of physical exercise programs in the hemodialysis units is usually limited by the inherent safeness and the lack of appropriate resources. Objectives: We aimed to evaluate the impact and safety outcomes of the implementation of an intradialytic physical exercise program (IPE) by a multidisciplinary team (physiotherapist and nursing assistant) in the physical condition of the patients. Material and methods: This six months single-centre and experimental pre-post prospective study was carried out in 34 patients. A two day-week combined IPE intervention was implemented. The cardiopulmonary capacity (6MWT), muscular strength (HG, leg dynamometry and 10STS), body composition (bioimpedance) and coordination capacity (Timed Up and Go test) was assessed at the beginning and at the end of the study. Safety was evaluated by means of the number of issues regarding the vascular access, the hemodynamic stability as well as the vascular refilling profile (RBV) in each session. The adhesion to the program was also registered. Additionally, analytical parameters were recorded. Results: The adhesion to an IPE program was high (70.8%). A significant improvement of the cardiopulmonary capacity (6MWT average increase 47m; p<0.001), superior limbs (HG average increase of 1.6kg; p=0.007) as well as the lower extremities (10STS; p=0.003; dynamometry p<0.05). Regarding safeness, there were no incidences neither significant difference in the RBV. Conclusions: A combined IPE may contribute to the improvement of the physical condition of the patients as well as ensures a safe development of the HD treatment. We suggest a multidisciplinary team in order to efficiently establish an IPE program. (AU)


Assuntos
Humanos , Exercício Físico , Diálise Renal , Eficácia , Estudos Prospectivos , Segurança , Força Muscular
20.
Clin Kidney J ; 14(3): 1004-1013, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34141409

RESUMO

BACKGROUND: Metabolic acidosis is a common problem in haemodialysis patients, but acidosis overcorrection has been associated with higher mortality. There is no clear definition of the optimal serum bicarbonate target or dialysate bicarbonate. This study analysed the impact of reducing dialysate bicarbonate from 35 to 32 mEq/L on plasma bicarbonate levels in a cohort of patients treated with online haemodiafiltration (OL-HDF). METHODS: We performed a prospective cohort study with patients in a stable chronic OL-HDF programme for at least 12 months in the Hospital Clinic of Barcelona. We analysed pre- and post-dialysis total carbon dioxide(TCO2) before and after dialysate bicarbonate reduction from 35 to 32 mEq/L, as well as the number of patients with a pre- and post-dialysis TCO2 within 19-25 and ≤29 mEq/L, respectively, after the bicarbonate modification. Changes in serum sodium, potassium, calcium, phosphorous and parathyroid hormone (PTH) were also assessed. RESULTS: We included 84 patients with a 6-month follow-up. At 6 months, pre- and post-dialysis TCO2 significantly decreased (26.78 ± 1.26 at baseline to 23.69 ± 1.92 mEq/L and 31.91 ± 0.91 to 27.58 ± 1.36 mEq/L, respectively). The number of patients with a pre-dialysis TCO2 >25 mEq/L was significantly reduced from 80 (90.5%) to 17 (20.2%) and for post-dialysis TCO2 >29 mEq/L this number was reduced from 83 (98.8%) to 9 (10.7%). PTH significantly decreased from 226.09 (range 172-296) to 182.50 (125-239) pg/mL at 6 months (P < 0.05) and post-dialysis potassium decreased from 3.16 ± 0.30 to 2.95 ± 0.48 mEq/L at 6 months (P < 0.05). Sodium, pre-dialysis potassium, calcium and phosphorous did not change significantly. CONCLUSIONS: Reducing dialysate bicarbonate concentration by 3 mEq/L significantly and safely decreased pre- and post-dialysis TCO2, avoiding acidosis overcorrection and improving secondary hyperparathyroidism control. An individualized bicarbonate prescription (a key factor in the adequate control of acidosis) according to pre-dialysis TCO2 is suggested based on these results.

SELEÇÃO DE REFERÊNCIAS