Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Breast Imaging ; 6(5): 493-501, 2024 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-39036960

RESUMO

OBJECTIVE: We compared the performance of 2 breast cancer screening approaches, automated breast US (ABUS) with same-day mammography (ABUS/MG) and handheld US (HHUS) with same-day mammography (HHUS/MG), in women with dense breasts to better understand the relative usefulness of ABUS and HHUS in a real-world clinical setting. METHODS: In this institutional review board-approved, retrospective observational study, we evaluated all ABUS/MG and HHUS/MG screening examinations performed at our institution from May 2013 to September 2021. BI-RADS categories, biopsy pathology results, and diagnostic test characteristics (eg, sensitivity, specificity) were compared between the 2 screening approaches using Fisher's exact test. RESULTS: A total of 1120 women with dense breasts were included in this study, with 852 undergoing ABUS/MG and 268 undergoing HHUS/MG. The sensitivities of ABUS/MG and HHUS/MG were 100% (5/5) and 75.0% (3/4), respectively, which was not a statistically significant difference (P = .444). The ABUS/MG approach demonstrated a slightly higher specificity (97.4% [825/847] vs 94.3% [249/264]; P = .028), higher accuracy (97.4% [830/852] vs 94.0% [252/268]; P = .011), and lower biopsy recommendation rate (3.2% [27/852] vs 6.7% [18/268]; P = .019) than the HHUS/MG approach in our patient population. CONCLUSION: Our findings suggest that ABUS/MG performs comparably with HHUS/MG as a breast cancer screening approach in women with dense breasts in a real-world clinical setting, with the ABUS/MG approach demonstrating a similar sensitivity and slightly higher specificity than the HHUS/MG approach. Additional variables, such as patient experience and physician time, may help determine which imaging approach to employ in specific clinical settings.


Assuntos
Densidade da Mama , Neoplasias da Mama , Detecção Precoce de Câncer , Mamografia , Sensibilidade e Especificidade , Ultrassonografia Mamária , Humanos , Feminino , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico , Mamografia/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade , Ultrassonografia Mamária/métodos , Detecção Precoce de Câncer/métodos , Idoso , Adulto , Mama/diagnóstico por imagem , Mama/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA