RESUMO
OBJECTIVES: Develop a sustainable bovine hydroxyapatite dental ceramic with the addition of titanium dioxide (TiO2) nanoparticles (5 % and 8 % by weight), analyzing the outcome of this addition to the microstructure, as well as its mechanical and chemical properties, in order to evaluate whether they satisfy the International Organization for Standardization (ISO) 6872:2015 for dental ceramics or not. METHODS: Disks were obtained through uniaxial followed by isostatic pressing from bovine hydroxyapatite powder and TiO2 nanoparticles and sintered at 1300ºC for 2 h. Three experimental groups were developed (HA, HA+5 %TiO2 and HA+8 %TiO2) and subjected to X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), indentation fracture (IF), biaxial flexural strength (BFS) and chemical solubility test. RESULTS: XRD revealed, for HA group, the appearance of a peak corresponding to b-tricalcium phosphate (ß-TCP). For HA+ 5 %TiO2 and HA+ 8 %TiO2, the entire composition was converted into ß-TCP and calcium titanate (CaTiO3). The SEM images showed a dense ceramic matrix and a uniform distribution of another phase in groups with TiO2 nanoparticles. HA+ 5 %TiO2 (1.40 ± 0.18 MPa.m1/2) and HA+ 8 %TiO2 (1.32 ± 0.18 MPa.m1/2) showed significantly higher fracture toughness values than HA (0.67 ± 0.09 MPa.m1/2). HA showed significantly higher characteristic stress (295.8 MPa) in comparison to groups with 5 % (235.1 MPa) and 8 % (214.4 MPa) TiO2 nanoparticles. Differences were not observed between the Weibull modulus values. The solubility results indicated that all experimental ceramics were above the 2000 ug/cm2 limit set by the ISO 6872:2015. SIGNIFICANCE: This study proposed the development and characterization of a new ceramic for dental prosthesis made from HA extracted from bovine bones, with the intention of reusing these solids waste and transforming them into a sustainable and low-cost material. Although the experimental calcium phosphate ceramic with additions of 5 % and 8 % of TiO2 achieved desirable mechanical properties, the chemical solubility values were very high.
RESUMO
This study aimed to produces and characterize bovine hydroxyapatite (HA) bioceramic with 3Y-TZP addition and analyze different sintering curves. HA was extracted from bovine bones and nanoparticulated. HA discs (0, 1, 5 and 10 wt% 3Y-TZP) were subjected to uniaxial and isostatic pressing. Dilatometry analysis was performed and the groups were sintered using 3 different firing curves (conventional, 1300 °C; 2-step, 1292 °C; 2-step, 1420 °C). The samples were analyzed by X-ray diffraction (XRD), biaxial flexural strength (BFS), Vickers microhardness (VH) and Field emission scanning electron microscopy (FE-SEM). The dilatometry results signaled the need for sintering optimization in groups added with 3Y-TZP. XRD demonstrated the characteristic crystallographic peaks of HA in the pure groups and with 1% 3Y-TZP, and decomposition of HA into ß-TCP and formation of calcium zirconate in the groups with 5 and 10% 3Y-TZP. Considering each composition, the groups of pure HA (131.3 ± 13.5 MPa; 401 ± 12.7 GPa) sintered by the conventional curve and HA+1%3Y-TZP (145 ± 8.6 MPa; 507 ± 47.9 GPa), HA+5%3Y-TZP (68.1 ± 14.2 MPa; 183 ± 9.8 GPa) and HA+10%3Y-TZP (55.6 ± 5.1 MPa; 96.1 ± 7.64 GPa) sintered by the 2-step curve at 1420 °C, combined the best BFS and VH results. The addition of 1 wt% 3Y-TZP and optimization in the sintering process improved the mechanical and microstructural properties of HA bioceramics and maintenance of its crystalline characteristics. Refinement in material processing is necessary for the future use of this bioceramic in dentistry.
Assuntos
Cerâmica , Durapatita , Teste de Materiais , Ítrio , Zircônio , Animais , Durapatita/química , Zircônio/química , Bovinos , Ítrio/química , Cerâmica/química , Dureza , Materiais Biocompatíveis/química , Fenômenos MecânicosRESUMO
Abutment components (i.e., fixtures associated with oral implants) are essentially made of titanium (Ti), which is continuously exposed to the hash oral environment, resulting in scratching. Thus, such components need to be protected, and surface treatments are viable methods for overcoming long-term damage. Diamond-like carbon (DLC), an excellent protective material, is an alternative surface-treatment material for Ti abutments. Here, we demonstrate that a silicon interlayer for DLC film growth and the pulsed-direct current plasma-enhanced chemical vapor deposition (DC-PECVD) method enables the deposition of an enhanced protective DLC film. As a result, the DLC film demonstrated a smooth topography with a compact surface. Furthermore, the DLC film enhanced the mechanical (load-displacement, hardness, and elastic modulus) and tribological properties of Ti as well as increased its corrosion resistance (16-fold), which surpassed that of a bare Ti substrate. The biofilm formed (Streptococcus sanguinis) after 24 h exhibited an equal bacterial load (â¼7 Log colony-forming units) for both the groups (Ti and DLC). In addition, the DLC film exhibited good cytocompatibility, owing to its noncytotoxicity toward human gingival fibroblast cells. Therefore, DLC deposition via DC-PECVD can be considered to be a promising protective and cytocompatible alternative for developing implant abutments with enhanced mechanical, tribological, and electrochemical properties.
Assuntos
Biofilmes , Carbono , Humanos , Carbono/química , Próteses e Implantes , Titânio/química , GasesRESUMO
The inorganic part of marine sponges, called Biosilica (BS), presents an osteogenic potential and the ability of consolidating fractures. Moreover, 3D printing technique is highly effective for manufacturing scaffolds for tissue engineering proposals. Thus, the aims of this study were to characterize the 3D rinted scaffolds, to evaluate the biological effects in vitro and to investigate the in vivo response using an experimental model of cranial defects in rats. The physicochemical characteristics of 3D printed BS scaffolds were analyzed by FTIR, EDS, calcium assay, evaluation of mass loss and pH measurement. For in vitro analysis, the MC3T3-E1 and L929 cells viability was evaluated. For the in vivo evaluation, histopathology, morphometrical and immunohistochemistry analyses were performed in a cranial defect in rats. After the incubation, the 3D printed BS scaffolds presented lower values in pH and mass loss over time. Furthermore, the calcium assay showed an increased Ca uptake. The FTIR analysis indicated the characteristic peaks for materials with silica and the EDS analysis demonstrated the main presence of silica. Moreover, 3D printed BS demonstrated an increase in MC3T3-E1 and L929 cell viability in all periods analyzed. In addition, the histological analysis demonstrated no inflammation in days 15 and 45 post-surgery, and regions of newly formed bone were also observed. The immunohistochemistry analysis demonstrated increased Runx-2 and OPG immunostaining. Those findings support that 3D printed BS scaffolds may improve the process of bone repair in a critical bone defect as a result of stimulation of the newly formed bone.
Assuntos
Poríferos , Alicerces Teciduais , Animais , Ratos , Alicerces Teciduais/química , Cálcio , Poríferos/química , Dióxido de Silício , Impressão TridimensionalRESUMO
OBJECTIVES: This study evaluated the effect of TiO2 nanoparticles + dense hydroxyapatite (HA) on human osteoblast cells (SAOS-2). METHODS: Particulate bovine HA powder with or without the addition of either 5 or 8 % TiO2 (HA, HA/TiO2Np5 % or HA/TiO2Np8 %) were pressed into disks (Ø = 12.5 mm; thickness = 1.3 mm) uniaxially (100 MPa) and isostatically (200 MPa/1 min) and sintered at 1300 °C. Y-TZP disks were used as control. The following tests were performed: Scanning Electron Microscopy and Dispersive Energy Spectroscopy (SEM/EDS), Atomic Force Microscopy (AFM), cell viability assay (Alamar Blue-AB) and mineralized matrix deposition (Alizarin Red-AR). AB and AR data were submitted to 2-way ANOVA/Tukey tests and ANOVA/Tukey tests, respectively. RESULTS: SEM revealed that the surface of HA/TiO2Np5% resembles DPBHA surface, but also contains smaller granules. HA/TiO2Np8% characteristics resembles HA/TiO2Np5% surface, but with irregular topography. Y-TZP showed a typical oxide ceramic surface pattern. EDS revealed Ca, O, and P in all samples. C, O, and Zr appeared in Y-TZP samples. AFM data corroborates SEM analysis. AB test revealed excellent cellular viability for HA/TiO2Np5% group. AR test showed that all groups containing TiO2np had more mineralized matrix deposition than all other groups, with statistically differences between HA/TiO2Np8% and HA cultivated in non-osteogenic medium. Culture in osteogenic medium exhibited much more mineralized matrix deposition by TiO2np groups. SIGNIFICANCE: In conclusion, the addition of TiO2np showed chemical, superficial, and biological changes in the reinforced materials. HA/TiO2Np5% showed the best results for cell viability and HA/TiO2Np8% for mineralized matrix deposition.
Assuntos
Durapatita , Nanopartículas , Animais , Bovinos , Durapatita/química , Durapatita/farmacologia , Humanos , Microscopia Eletrônica de Varredura , Osteoblastos , Óxidos/farmacologia , Pós , Propriedades de Superfície , Titânio/química , Titânio/farmacologiaRESUMO
PURPOSE: To analyze and compare the reactions at the interface between the composite, composed of fragmented heterologous mineralized bone matrix (MOMHF) and polymethylmethacrylate (PMMA), and the rabbit's tibias, through macroscopic evaluation and scanning electron microscopy (SEM) in different periods. METHODS: In this study, 12 New Zealand adult rabbits were used (E1: n = 3, E2: n = 3, E3: n = 3 and E4: n = 3). They had the right tibial defects filled with composite and were evaluated immediately after surgery and at 30, 60, 90, and 120 days. RESULTS: The composites were incorporated and integrated into the recipient beds in 100% of the cases, defined by the MOMHF osseointegration and the PMMA fibrointegration, with no sign of infection, migration, or rejection. CONCLUSIONS: The behavior of the composites in the recipient beds demonstrates that these biomaterials have the potential to be used in bone defect repairs, offering, thus, better quality of life to the orthopedic patient.
Assuntos
Matriz Óssea , Polimetil Metacrilato , Animais , Materiais Biocompatíveis , Humanos , Osseointegração , Qualidade de Vida , Coelhos , Tíbia/cirurgiaRESUMO
ABSTRACT Purpose To analyze and compare the reactions at the interface between the composite, composed of fragmented heterologous mineralized bone matrix (MOMHF) and polymethylmethacrylate (PMMA), and the rabbit's tibias, through macroscopic evaluation and scanning electron microscopy (SEM) in different periods. Methods In this study, 12 New Zealand adult rabbits were used (E1: n = 3, E2: n = 3, E3: n = 3 and E4: n = 3). They had the right tibial defects filled with composite and were evaluated immediately after surgery and at 30, 60, 90, and 120 days. Results The composites were incorporated and integrated into the recipient beds in 100% of the cases, defined by the MOMHF osseointegration and the PMMA fibrointegration, with no sign of infection, migration, or rejection. Conclusions The behavior of the composites in the recipient beds demonstrates that these biomaterials have the potential to be used in bone defect repairs, offering, thus, better quality of life to the orthopedic patient.
Assuntos
Matriz Óssea , Polimetil Metacrilato , Qualidade de Vida , Coelhos , Tíbia/cirurgia , Materiais Biocompatíveis , OsseointegraçãoRESUMO
Abstract This study characterized the morphological aspects of marine collagen - spongin (SPG) extract from marine sponges, as well as, evaluating its in vitro and in vivo biological performance. Aplysina fulva marine sponge was used for the SPG extraction. It was investigated the physicochemical and morphological properties of SPG by using scanning electron microscopy, Fourier transform infrared spectroscopy, X-ray diffraction and compared to PMMA and bovine collagen. Additionally, the SPG cytotoxicity and its influence on cell proliferation, through in vitro tests. Moreover, the in vivo biological response was investigated using an experimental model of tibial bone defect. The results demonstrated that SPG presented an irregular granular aspect, with a composition of OH, C=O, NH, CN and an amorphous profile. Also, in vitro viability results for the L929 and MC3T3 cell lines cultured with SPG extracts demonstrated normal growth in comparison to controls, except for MC3T3 viability at day 3. For in vivo analysis, using tibial bone defects in rats, SPG treated animals presented an increased rate of material resorption and higher granulation and bone formation deposition in the region of the defect, mainly after 45 days. As a conclusion, SPG was successfully extracted. The in vitro and in vivo studies pointed out that SPG samples produced an increase in L929 and MC3T3 viability and improved the performance in tibial bone defects. It can be concluded that SPG can be used as a bone graft for bone regeneration.
RESUMO
Biomaterials and bone grafts, with the ability of stimulating tissue growth and bone consolidation, have been emerging as very promising strategies to treat bone fractures. Despite its well-known positive effects of biosilicate (BS) on osteogenesis, its use as bone grafts in critical situations such as bone defects of high dimensions or in non-consolidated fractures may not be sufficient to stimulate tissue repair. Consequently, several approaches have been explored to improve the bioactivity of BS. A promising strategy to reach this aim is the inclusion of an organic part, such as collagen, in order to mimic bone structure. Thus, the present study investigated the biological effects of marine spongin (SPG)-enriched BS composites on the process of healing, using a critical experimental model of cranial bone defect in rats. Histopathological and immunohistochemistry analyzes were performed after two and six weeks of implantation to investigate the effects of the material on bone repair (supplemental material-graphical abstract). Histological analysis demonstrated that for both BS and BS/SPG, similar findings were observed, with signs of material degradation, the presence of granulation tissue along the defect area and newly formed bone into the area of the defect. Additionally, histomorphometry showed that the control group presented higher values for Ob.S/BS (%) and for N.Ob/T.Ar (mm2) (six weeks post-surgery) compared to BS/SPG and higher values of N.Ob/T.Ar (mm2) compared to BS (two weeks post-surgery). Moreover, BS showed higher values for OV/TV (%) compared to BS/SPG (six weeks post-surgery). Also, VEGF immunohistochemistry was increased for BS (two weeks post-surgery) and for BS/SPG (six weeks) compared to CG. TGFb immunostaining was higher for BS compared to CG. The results of this study demonstrated that the BS and BS/SPG scaffolds were biocompatible and able to support bone formation in a critical bone defect in rats. Moreover, an increased VEGF immunostaining was observed in BS/SPG.
Assuntos
Materiais Biocompatíveis/química , Vidro/química , Poríferos/química , Alicerces Teciduais/química , Animais , Materiais Biocompatíveis/uso terapêutico , Masculino , Ratos Wistar , Crânio/lesões , Crânio/patologia , Crânio/ultraestrutura , Engenharia Tecidual/métodosRESUMO
One of the most promising strategies to improve the biological performance of bone grafts is the combination of different biomaterials. In this context, the aim of this study was to evaluate the effects of the incorporation of marine spongin (SPG) into Hydroxyapatite (HA) for bone tissue engineering proposals. The hypothesis of the current study is that SPG into HA would improve the biocompatibility of material and would have a positive stimulus into bone formation. Thus, HA and HA/SPG materials were produced and scanning electron microscopy (SEM) analysis was performed to characterize the samples. Also, in order to evaluate the in vivo tissue response, samples were implanted into a tibial bone defect in rats. Histopathological, immunohistochemistry, and biomechanical analyses were performed after 2 and 6 weeks of implantation to investigate the effects of the material on bone repair. The histological analysis demonstrated that composite presented an accelerated material degradation and enhanced newly bone formation. Additionally, histomorphometry analysis showed higher values of %BV/TV and N.Ob/T.Ar for HA/SPG. Runx-2 immunolabeling was higher for the composite group and no difference was found for VEGF. Moreover, the biomechanical analysis demonstrated similar values for all groups. These results indicated the potential of SPG to be used as an additive to HA to improve the biological performance for bone regeneration applications. However, further long-term studies should be carried out to provide additional information regarding the material degradation and bone regeneration.
Assuntos
Osso e Ossos/efeitos dos fármacos , Colágeno/farmacologia , Durapatita/farmacologia , Poríferos/química , Cicatrização/efeitos dos fármacos , Animais , Materiais Biocompatíveis , Osso e Ossos/lesões , Masculino , Ratos Wistar , Tíbia/efeitos dos fármacos , Tíbia/lesões , Alicerces Teciduais/químicaRESUMO
This study aimed to produce a new SiO2+Y-TZP ceramic via uniaxial/isostatic compression that was structurally and chemically characterized relating to its translucency and flexural strength. SiO2 and Y-TZP were mixed using a ball mill, pressed and sintered at 1150 °C. The optical and mechanical properties of the specimens were compared to lithium disilicate (LD) and zirconia-reinforced lithium silicate (ZLS) (Kruskal-Wallis, α = 0.05). The Fourier Transform Infrared Spectroscopy bands suggested an interaction between Si, O and Zr. Contrast ratio and translucency parameter of the experimental ceramic were higher and lower, (p = 0.000001) respectively, than those of the LD and ZLS. The experimental ceramic presented similar flexural strength to ZLS, but lower than LD (p < 0.0001). It can be concluded that this processing method is efficient to obtain a SiO2+Y-TZP ceramic and 1150 °C crystallizes SiO2 without inducing t-m transformation. The SiO2+Y-TZP ceramic presented lower translucency and higher masking ability than the commercially available glass-ceramics, but similar flexural strength to one glass-ceramics.
Assuntos
Dióxido de Silício , Zircônio , Cerâmica , Porcelana Dentária , Teste de Materiais , Propriedades de Superfície , ÍtrioRESUMO
PURPOSE: To evaluate the shear bond strength (SBS) between Y-TZP and a resin luting agent, after 1 of 2 enhancing strategies with TiO2--nts was applied, either to the resin luting agent or the Y-TZP mass, in different concentrations. METHODS: In the Strategy TiO2-nts on ceramic, the resin luting agent Panavia F2.0™ (Kuraray) and an experimental Y-TZP with added concentrations of TiO2--nts (0%, 1%, 2%, and 5% vol/vol) and a commercial Y-TZP, comprised 5 different groups (n = 10). In the Strategy TiO2-nts on cement, the resin luting agent RelyX U200™ (3 M ESPE) was added with different concentrations of TiO2--nts (0%, 0.3%, 0.6%, 0.9% wt/wt) luted to a commercial Y-TZP, comprising 4 different groups (n = 10). The Y-TZP discs were included in acrylic bases, and a cylinder (3 × 3 mm) of the correspondent luting agent for each respective group was applied over them. After 24 h, specimens were subjected to SBS assessments in a universal testing machine. Field emission scanning electron microscopy and energy dispersive X-ray spectroscopy analyses were also performed on Y-TZP surfaces. Data were analyzed via analysis of variance and Tukey tests (α = 0.05). RESULTS: TiO2-nts on ceramic influenced the bond strength significantly, but not linearly; TiO2-nts on cement did not influence bond strength when analyzed separately, nor in comparison with the first. CONCLUSION: Y-TZP enhancements with TiO2-nts led to a higher SBS with Panavia F2.0, a 5% TiO2--nt concentration presented the highest bond strength. Modified Rely X U200 did not improve SBS.
Assuntos
Colagem Dentária , Nanotubos , Cimentos Dentários , Análise do Estresse Dentário , Teste de Materiais , Microscopia Eletrônica de Varredura , Cimentos de Resina , Resistência ao Cisalhamento , Propriedades de Superfície , Titânio , Ítrio , ZircônioAssuntos
Materiais Biocompatíveis/química , Substitutos Ósseos/química , Cerâmica/química , Colágeno/química , Magnésio/química , Alicerces Teciduais/química , Animais , Materiais Biocompatíveis/metabolismo , Regeneração Óssea , Substitutos Ósseos/metabolismo , Cerâmica/metabolismo , Colágeno/metabolismo , Reagentes de Ligações Cruzadas/química , Magnésio/metabolismo , Masculino , Fenômenos Mecânicos , Modelos Animais , Osteogênese , Polimetil Metacrilato/síntese química , Polimetil Metacrilato/metabolismo , Próteses e Implantes , Ratos Wistar , Fatores de Tempo , Engenharia TecidualRESUMO
This study evaluated physical-chemical characteristics of a vacuumed collagen-impregnated bioglass (BG) scaffolds and bone marrow stromal cells (BMSCs) behavior on those composites. scanning electron microscope and energy dispersive x-ray spectroscope demonstrated collagen (Col) was successfully introduced into BG. Vacuum impregnation system has showed efficiency for Col impregnation in BG scaffolds (approximately 20 wt %). Furthermore, mass weight decreasing and more stabilized pH were observed over time for BG/Col upon incubation in phosphate buffered saline compared to plain BG under same conditions. Calcium evaluation (Ca assay) demonstrated higher calcium uptake for BG/Col samples compared to BG. In addition, BG samples presented hydroxyapatite crystals formation on its surface after 14 days in simulated body fluid solution, and signs of initial degradation were observed for BG and BG/Col after 21 days. Fourier transform infrared spectroscopy spectra for both groups indicated peaks for hydroxyapatite formation. Finally, a significant increase of BMSCs viability for both composites was observed compared to control group, but no increase of osteogenic differentiation-related gene expressions were found. In summary, BG/Col scaffolds have improved degradation, pH equilibrium and Ca mineralization over time, accompanied by hydroxyapatite formation. Moreover, both BG and BG/Col scaffolds were biocompatible and noncytotoxic, promoting a higher cell viability compared to control. Future investigations should focus on additional molecular and in vivo studies in order to evaluate biomaterial performance for bone tissue engineering applications. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 107B: 211-222, 2019.
Assuntos
Células da Medula Óssea/metabolismo , Diferenciação Celular , Proliferação de Células , Cerâmica/química , Colágeno/química , Células-Tronco Mesenquimais/metabolismo , Alicerces Teciduais/química , Animais , Células da Medula Óssea/citologia , Teste de Materiais , Células-Tronco Mesenquimais/citologia , Ratos , Ratos WistarRESUMO
This study reports the development of a servo-controlled power-assisted wheelchair, designed to reduce the loads on the upper limbs while maintaining the drivability of a manual chair. It is presented the concept and implementation of an assisted propulsion system, focusing on the assistance controlling and the torque transmission.
Assuntos
Desenho de Equipamento , Cadeiras de Rodas , Fenômenos Biomecânicos , Humanos , Torque , Extremidade SuperiorRESUMO
Subluxação do ombro é a complicação musculoesquelética mais comum das afecções do Sistema Nervoso Central e Periférico, que leva a diminuição do movimento, da função e aumento de dor. Órtese é um dos recursos auxiliares utilizados no tratamento desta patologia e visa corrigir deformidade, diminuir dor e proporcionar função ao membro acometido. Objetivo: Este trabalho propõe uma nova metodologia para projetar e fabricar órteses customizadas estabilizadoras de ombro utilizando as tecnologias de aquisição 3D por escaneamento e de fabricação por Impressão 3D, e assegurar melhor adaptabilidade e maior conforto para o usuário. Método: A metodologia utilizada neste estudo foi dividida em cinco fases: estudo de caso, escaneamento, modelagem e impressão em 3D; e acabamento. O estudo de caso do usuário com lesão de plexo braquial motivou o projeto de desenho original de órtese híbrida, personalizada e manufaturada em 3D, usando estrutura rígida e faixas de tração, com objetivo de estabilizar o ombro, diminuir a dor e permitir função. Resultados: Após escaneamento em 3D utilizou-se softwares especializados para processar a imagem tridimensional STL. Realizaram-se otimizações do projeto com geração de modelos e peças prototipadas em FDM; avaliada pelo usuário. O conceito desenvolvido foi: órtese personalizada, fácil de higienizar e vestir, resistente, articulada, veste nos dois braços com faixas de tração em tecido rígido acoplado à cintura. Conclusão: O teste com usuário corroborou com o conceito projetado e mostrou um protótipo preliminar com bom acoplamento ao tronco, tração satisfatória e possibilidade de realizar um maior número de AVD´s com menos dor e/ou sensação de cansaço
Subluxation of the shoulder is the most common musculoskeletal complication of Central and Peripheral Nervous System disorders, which leads to decreased movement, function, and increased pain. Objective: Orthosis is one of the assistive devices used in the treatment of this pathology and it focuses in correcting deformity, decreasing pain and providing function to the affected member. This study proposes a new methodology for designing and manufacturing customized shoulder stabilization orthoses with 3D scan image acquisition and 3D printing technologies, for ensuring better adaptability and comfort for the user. Method: The methodology used in this study was divided into five phases: case study, scanning, modeling and 3D printing; and finishing. The case study included a user with brachial plexus injury that motivated the original design of hybrid orthosis, personalized and manufactured in 3D, with rigid structure and traction straps, for stabilizing the shoulder, reduce pain and allowing function. Results: After 3D scanning, we used specialized software to process the three-dimensional STL image. Optimization of the project with generation of models and prototyped parts in FDM based on the user evaluations was performed. The developed concept was: personalized orthosis, easy to clean and wear, resistant, articulated, for wearing in both arms with traction straps in rigid fabric coupled to the waist. Conclusion: The user test corroborated with the designed concept and showed a preliminary prototype with good trunk coupling, satisfactory traction and possibility of performing a greater number of ADLs with less pain and/or tiredness
Assuntos
Humanos , Aparelhos Ortopédicos/normas , Ombro/fisiopatologia , Desenvolvimento Tecnológico , Impressão Tridimensional/normas , Extremidade Superior/fisiopatologiaRESUMO
Abstract Introduction Biomechanical assessment of trabecular bone microarchitecture contributes to the evaluation of fractures risk associated with osteoporosis and plays a crucial role in planning preventive strategies. One of the most widely clinical technics used for osteoporosis diagnosis by health professionals is bone dual-energy X-ray absorptiometry (DEXA). However, doubts about its accuracy motivate the introduction of congruent technical analysis such as calcaneal ultrasonometry (Quantitative Ultrasonometry - QUS). Methods Correlations between Bone Quality Index (BQI), determined by calcaneal ultrasonometry of thirty (30) individuals classified as normal, osteopenic and osteoporotic, and elastic modulus (E) and ultimate compressive strength (UCS) from axial compression tests of ninety (90) proof bodies from human vertebrae trabecular bone, which were extracted from cadavers in the twelfth thoracic region (T12), first and fourth lumbar (L1 and L4). Results Analysis of variance (ANOVA) showed significant differences for E (p = 0.001), for UCS (p = 0.0001) and BQI. Spearman's rank correlation coefficient (rho) between BQI and E (r = 0.499) and BQI and UCS (r = 0.508) were moderate. Discussion Calcaneal ultrasonometry technique allowed a moderate estimate of bone mechanical strength and fracture risk associated with osteoporosis in human vertebrae.
RESUMO
Abstract Introduction Rheumatoid arthritis (RA) is a chronic, multisystem disease that involves synovial inflammation, leading to deformities, like finger ulnar deviation, pain and functional difficulties. The conservative treatment comprises orthoses, features added to the body that aims to correct deformity, reduce pain and improve functionality. In the market there are few kinetic/mobile orthosis models for correction of ulnar deviation in the fingers. However, users usually complain about increased palmar volume, presence of pressure points and functional loss, demonstrating the necessity to develop more effective orthoses. In this paper we introduce an innovative concept, of an original and articulate dynamic/kinetics orthosis, which aims to correct this finger deformity and encourage functionality. Methods Methodological procedures were divided into: Need Recognition; Specification Concept; Prototype and Validation. This paper deals with the last two stages of this research. Results A virtual orthosis prototype using CAD Solid Edge Insight™ was proposed. The orthosis developed consisted of 10 pieces, made of metal and resin with carbon fiber. Conclusion After virtual movement simulation, it was verified that the prototype allows for wrist and finger flexion/extension, the possibility of bilateral use, and provids ulnar deviation correction for the fingers. The final product is innovative and is easy to put on/off; volunteers claimed that the new prototype was satisfactory in terms of deformity correction.
RESUMO
This work introduces an alternative way to perform the T2 - T2 Exchange NMR experiment. Rather than varying the number of π pulses in the first CPMG cycle of the T2 - T2 Exchange NMR pulse sequence, as used to obtain the 2D correlation maps, it is fixed and small enough to act as a short T2-filter. By varying the storage time, a set of 1D measurements of T2 distributions can be obtained to reveal the effects of the migration dynamics combined with relaxation effects. This significantly reduces the required time to perform the experiment, allowing a more in-depth study of exchange dynamics and relaxation processes with improved signal-to-noise ratio. These aspects stand as basis of this novel experiment, T2-Filtered T2 - T2 Exchange NMR or simply T2 F-TREx.
RESUMO
Many aspects relating to equipment configuration affect users' actions in a manual wheelchair, determining the overall mobility performance. Since the equipment components and configuration determine both stability and mobility efficiency, configuring the wheelchair with the most appropriate set-up for individual users' needs is a difficult task. Several studies have shown the importance of seat/backrest assembly and the relative position of the rear wheels to the user in terms of the kinetics and kinematics of manual propulsion. More recently, new studies have brought to light evidence on the inertial properties of different wheelchair configurations. Further new studies have highlighted the handrim as a key component of wheelchair assembly, since it is the interface through which the user drives the chair. In light of the new evidence on wheelchair mechanics and propulsion kinetics and kinematics, this article presents a review of the most important aspects of wheelchair configuration that affect the users' actions and mobility.