Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
JFMS Open Rep ; 7(1): 2055116921994516, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34104462

RESUMO

CASE SUMMARY: A 7-month-old intact female Maine Coon cat was presented with a 2-month history of regurgitations. Contrast radiographic and endoscopic examinations revealed a diffuse megaoesophagus secondary to a severe lower oesophageal stricture. An epiphrenic diverticulum was noted. Endoscopic balloon dilation was unsuccessful. Gastrotomy was thus performed in order to incise the oesophageal wall radially along the stricture site, and then to dilate the stricture. A diameter of 20 mm was reached. With the aim of preventing stricture recurrence, submucosal injections of triamcinolone acetonide were performed. An 18 Fr oesophagogastric feeding tube was placed and a left gastropexy was performed in order to exert some traction on the gastroesophageal junction, with the aim of reducing the oesophageal diverticulum. Twelve months postoperatively, clinical signs had completely resolved and follow-up radiographs revealed marked improvement of the oesophageal dilatation. RELEVANCE AND NOVEL INFORMATION: Lower oesophageal strictures should be considered when evaluating regurgitations or megaoesophagus in a kitten. Surgical mucosal radial incision is a therapeutic option in cases of lower oesophageal stricture refractory to balloon dilation, and can lead to a marked improvement of clinical signs and of the oesophagus diameter leading to clinical success.

2.
Open Vet J ; 9(2): 109-113, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31360648

RESUMO

A 15-year-old neutered female domestic shorthair cat was presented for weight loss, polydipsia/polyuria, and lethargy. A large fluctuant mass was palpated in the ventral right cervical region. Biochemistry results were consistent with primary hyperparathyroidism. Parathyroid hormone level in the fluid was higher to that observed in the plasma, consistent with a cystic parathyroid lesion. Right parathyroidectomy and thyroidectomy were performed without complications. Ionized calcium normalized within a few hours. Histopathology yielded a diagnosis of cystic parathyroid adenoma. Follow-up showed complete recovery of clinical signs and normalization of ionized calcium. This case shows an uncommon presentation of feline primary hyperparathyroidism secondary to a cystic parathyroid adenoma and is, to our knowledge, the first case presented with a large palpable mass in which parathyroid hormone concentration was measured. This report highlights the value of selective hormonal analyses of the cystic fluid to confirm the origin of the cystic lesion pre-operatively.


Assuntos
Adenoma/veterinária , Doenças do Gato/cirurgia , Hiperparatireoidismo Primário/veterinária , Neoplasias das Paratireoides/veterinária , Adenoma/diagnóstico , Adenoma/patologia , Adenoma/cirurgia , Animais , Doenças do Gato/diagnóstico , Doenças do Gato/patologia , Gatos , Feminino , Hiperparatireoidismo Primário/diagnóstico , Hiperparatireoidismo Primário/patologia , Hiperparatireoidismo Primário/cirurgia , Pescoço/patologia , Neoplasias das Paratireoides/diagnóstico , Neoplasias das Paratireoides/patologia , Neoplasias das Paratireoides/cirurgia , Paratireoidectomia/veterinária , Tireoidectomia/veterinária , Resultado do Tratamento
3.
Vet Comp Orthop Traumatol ; 31(6): 422-430, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30300914

RESUMO

OBJECTIVES: The main purpose of this study was to determine the reproducibility and accuracy of a three-dimensional (3D) bone model printed on a desktop 3D-printer based on fused deposition modelling (FDM) technology with polylactic acid (PLA) and the effect of autoclave sterilization on the printed models. METHODS: Computed tomographic images of the tibia were obtained from 10 feline cadavers, used to create a bone surface-rendering file and sent to the 3D printing software. Right and left tibias were each printed five times with the FDM desktop 3D printer using PLA plastic material. Plastic models and cadaveric bones were measured with a profile projector device at six predetermined landmarks. Plastic bones were then sterilized using an autoclave before being re-measured applying the same method. Analyses of printed model size reliability were conducted using intra-class correlation coefficients (ICC) and Bland-Altman plots. RESULTS: The ICC always showed an almost perfect agreement when comparing 3D-printed models issued from the same cadaveric bone. The ICC showed moderate agreement for one measurement and strong/perfect agreement for others when comparing a cadaveric bone with the corresponding 3D model. Concerning the comparison of the same 3D-printed model, before and after sterilization, ICC showed either strong or perfect agreement. CLINICAL SIGNIFICANCE: Rapid-prototyping with our FDM desktop 3D-printer using PLA was an accurate, a reproducible and a sterilization-compliant way to obtain 3D plastic models.


Assuntos
Impressão Tridimensional , Animais , Gatos , Impressão Tridimensional/instrumentação , Reprodutibilidade dos Testes , Esterilização/métodos , Tíbia/diagnóstico por imagem , Tomografia Computadorizada por Raios X
4.
Vet Radiol Ultrasound ; 59(6): 749-757, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30058090

RESUMO

During minimally invasive spinal surgery, correct identification of the affected intervertebral disc space is critical. Percutaneous palpation is commonly used, but results may be unreliable. Fluoroscopy is the gold standard but can be cumbersome and exposes operators to ionizing radiation. Spinal ultrasound has been described in veterinary medicine and could be a feasible alternative. This prospective, methods comparison study mimicked a minimally invasive spinal surgery in 10 canine cadavers and compared the accuracy of ultrasound and percutaneous palpation for thoracolumbar intervertebral disc space identification, using fluoroscopy as the reference standard. For each experiment, a disc space was randomly chosen. Identification was then attempted using both percutaneous palpation and ultrasound. For ultrasound, a linear probe was used to guide the operator to the correct location. The time necessary to perform each method was recorded. Accuracies for each method were calculated and statistically compared. Effects of body condition score, location of the targeted thoracolumbar intervertebral disc space and learning curve for each method were also evaluated. Ultrasonographic identification was more accurate (96.7% vs. 76.7%; P < 0.03) but took longer (147 s vs. 29 s; P < 0.0001) than percutaneous palpation. Findings from this cadaver study indicated that percutaneous palpation alone had low accuracy for correctly identifying a targeted thoracolumbar intervertebral disc space and supported the use of ultrasound as a method for improving the accuracy. Future studies are needed to assess the method in clinical cases, especially in obese dogs and/or those in which the targeted site is distant from palpable anatomical landmarks.


Assuntos
Cães/anatomia & histologia , Disco Intervertebral/diagnóstico por imagem , Vértebras Lombares/fisiologia , Palpação/veterinária , Vértebras Torácicas/fisiologia , Ultrassonografia/veterinária , Animais , Cadáver , Feminino , Vértebras Lombares/diagnóstico por imagem , Masculino , Palpação/métodos , Estudos Prospectivos , Vértebras Torácicas/diagnóstico por imagem , Ultrassonografia/métodos
5.
Vet Comp Orthop Traumatol ; 31(1): 53-61, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29325193

RESUMO

OBJECTIVES: This article aimed to describe olecranon fracture in dogs and cats and their stabilization with tension band wiring or plate osteosynthesis, and to evaluate complications associated with each technique. METHODS: Medical records of cats and dogs that had been surgically treated for olecranon fractures with either tension band wiring or plate osteosynthesis were retrospectively reviewed. The surgical technique, complications and long-term outcomes were assessed. RESULTS: Forty-one olecranon fractures were included. Fractures were articular, comminuted and open in 90, 31 and 27% of cases, respectively. Tension band wiring and plate osteosynthesis were performed in 22 and 19 fractures, respectively. Complications occurred more commonly after tension band wiring (74%) compared with plate osteosynthesis (27%) (p = 0.002) and these were probably related to it being used in comminuted fractures (p = 0.01) or to errors in technique. Minor complications included Kirschner wires migration (n = 5), pain (n = 3), osteomyelitis (n = 3), skin breakdown (n = 3) and seroma (n = 1). Implant failure requiring further fixation (n = 4) was observed only in the tension band wiring group. Other major complications included skin wound debridement and closure (n = 1) and chronic lameness requiring implant removal (n = 7). Long-term functional outcomes were excellent regardless of the technique used. CLINICAL SIGNIFICANCE: Plate osteosynthesis should be performed for olecranon fracture repair if technically feasible.


Assuntos
Placas Ósseas/veterinária , Fios Ortopédicos/veterinária , Gatos/lesões , Cães/lesões , Fixação Interna de Fraturas/veterinária , Olécrano/lesões , Animais , Gatos/cirurgia , Cães/cirurgia , Feminino , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Masculino , Olécrano/diagnóstico por imagem , Olécrano/cirurgia , Radiografia/veterinária , Estudos Retrospectivos
6.
J Orthop Res ; 35(12): 2637-2645, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-28401593

RESUMO

Tissue-engineered constructs (TECs) combining resorbable calcium-based scaffolds and mesenchymal stem cells (MSCs) have the capability to regenerate large bone defects. Inconsistent results have, however, been observed, with a lack of osteoinductivity as a possible cause of failure. This study aimed to evaluate the impact of the addition of low-dose bone morphogenetic protein-2 (BMP-2) to MSC-coral-TECs on the healing of clinically relevant segmental bone defects in sheep. Coral granules were either seeded with autologous MSCs (bone marrow-derived) or loaded with BMP-2. A 25-mm-long metatarsal bone defect was created and stabilized with a plate in 18 sheep. Defects were filled with one of the following TECs: (i) BMP (n = 5); (ii) MSC (n = 7); or (iii) MSC-BMP (n = 6). Radiographic follow-up was performed until animal sacrifice at 4 months. Bone formation and scaffold resorption were assessed by micro-CT and histological analysis. Bone union with nearly complete scaffold resorption was observed in 1/5, 2/7, and 3/6 animals, when BMP-, MSC-, and MSC-BMP-TECs were implanted, respectively. The amount of newly formed bone was not statistically different between groups: 1074 mm3 [970-2478 mm3 ], 1155 mm3 [970-2595 mm3 ], and 2343 mm3 [931-3276 mm3 ] for BMP-, MSC-, and MSC-BMP-TECs, respectively. Increased scaffold resorption rate using BMP-TECs was the only potential side effect observed. In conclusion, although the dual delivery of MSCs and BMP-2 onto a coral scaffold further increased bone formation and bone union when compared to single treatment, results were non-significant. Only 50% of the defects healed, demonstrating the need for further refinement of this strategy before clinical use. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2637-2645, 2017.


Assuntos
Proteína Morfogenética Óssea 2/administração & dosagem , Regeneração Óssea/efeitos dos fármacos , Transplante de Células-Tronco Mesenquimais , Alicerces Teciduais , Animais , Antozoários , Avaliação Pré-Clínica de Medicamentos , Feminino , Regeneração Tecidual Guiada , Ossos do Metatarso , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...