1.
Mater Sci Eng C Mater Biol Appl ; 130: 112467, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34702542

RESUMO

Titanium-based implants are the leading material for orthopaedic surgery, due to their strength, versatility, fabrication via additive manufacturing and invoked biological response. However, the interface between the implant and the host tissue requires improvement to better integrate the implant material and mitigate foreign body response. The interface can be manipulated by changing the surface energy, chemistry, and topography of the Titanium-based implant. Recently, polycrystalline diamond (PCD) has emerged as an exciting coating material for 3D printed titanium scaffolds showing enhanced mammalian cell functions while inhibiting bacterial attachment in vitro. In this study, we performed in-depth characterisation of PCD coatings investigating the surface topography, thickness, surface energy, and compared its foreign body response in vivo with uncoated titanium scaffold. Coating PCD onto titanium scaffolds resulted in a similar microscale surface roughness (RMS(PCD-coated) = 24 µm; RMS(SLM-Ti) = 28 µm), increased nanoscale roughness (RMS(PCD-coated) = 35 nm; RMS(SLM-Ti) = 66 nm) and a considerable decrease in surface free energy (E(PCD-coated) = 4 mN m-1; E(SLM-Ti) = 16 mN m-1). These surface property changes were supported by X-ray photoelectron spectroscopy (XPS) and Raman spectroscopy as corresponding to observed surface chemistry changes induced by the coating. The underlying mechanism of how the diamond coatings chemical and physical properties changes the wettability of implants was examined. In vivo, the coated scaffolds induced similar level of fibrous encapsulation with uncoated scaffolds. This study thus provides further insight into the physicochemical characteristics of PCD coatings, adding evidence to the promising potential of PCD-coatings of medical implants.


Assuntos
Corpos Estranhos , Titânio , Animais , Materiais Revestidos Biocompatíveis/farmacologia , Diamante , Impressão Tridimensional , Propriedades de Superfície
2.
Nanomaterials (Basel) ; 10(11)2020 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-33203046

RESUMO

Bacterial biofilms are involved in most device-associated infections and remain a challenge for modern medicine. One major approach to addressing this problem is to prevent the formation of biofilms using novel antimicrobial materials, device surface modification or local drug delivery; however, successful preventive measures are still extremely limited. The other approach is concerned with treating biofilms that have already formed on the devices; this approach is the focus of our manuscript. Treating biofilms associated with medical devices has unique challenges due to the biofilm's extracellular polymer substance (EPS) and the biofilm bacteria's resistance to most conventional antimicrobial agents. The treatment is further complicated by the fact that the treatment must be suitable for applying on devices surrounded by host tissue in many cases. Nanomaterials have been extensively investigated for preventing biofilm formation on medical devices, yet their applications in treating bacterial biofilm remains to be further investigated due to the fact that treating the biofilm bacteria and destroying the EPS are much more challenging than preventing adhesion of planktonic bacteria or inhibiting their surface colonization. In this highly focused review, we examined only studies that demonstrated successful EPS destruction and biofilm bacteria killing and provided in-depth description of the nanomaterials and the biofilm eradication efficacy, followed by discussion of key issues in this topic and suggestion for future development.

3.
J Neural Eng ; 17(4): 045014, 2020 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-32659750

RESUMO

OBJECTIVE: Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing Nitrogen incorporated ultrananocrystalline (N-UNCD) diamond electrodes. APPROACH: A prototype implant containing up to twenty-five 120 × 120 µm N-UNCD electrodes was implanted into 16 anaesthetised cats and attached to the retina either using a single tack or via magnetic coupling with a suprachoroidally placed magnet. Multiunit responses to retinal stimulation using charge-balanced biphasic current pulses were recorded acutely in the visual cortex using a multichannel planar array. Several stimulus parameters were varied including; the stimulating electrode, stimulus polarity, phase duration, return configuration and the number of electrodes stimulated simultaneously. MAIN RESULTS: The rigid nature of the device and its form factor necessitated complex surgical procedures. Surgeries were considered successful in 10/16 animals and cortical responses to single electrode stimulation obtained in eight animals. Clinical imaging and histological outcomes showed severe retinal trauma caused by the device in situ in many instances. Cortical measures were found to significantly depend on the surgical outcomes of individual experiments, phase duration, return configuration and the number of electrodes stimulated simultaneously, but not stimulus polarity. Cortical thresholds were also found to increase over time within an experiment. SIGNIFICANCE: The study successfully demonstrated that an epiretinal prosthesis containing diamond electrodes could produce cortical activity with high precision, albeit only in a small number of cases. Both surgical approaches were highly challenging in terms of reliable and consistent attachment to and stabilisation against the retina, and often resulted in severe retinal trauma. There are key challenges (device form factor and attachment technique) to be resolved for such a device to progress towards clinical application, as current surgical techniques are unable to address these issues.


Assuntos
Diamante , Próteses Visuais , Animais , Gatos , Estimulação Elétrica , Eletrodos , Eletrodos Implantados , Estudos de Viabilidade , Retina
4.
Int J Nanomedicine ; 14: 9929-9939, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31908450

RESUMO

PURPOSE: The aim of this study is to develop a new coating for wound dressings that is comprised of antimicrobial silver (Ag) and antioxidant flavonoid quercetin (Q). METHODS: Dip-coating was used to apply the coating on cotton gauge as a model dressing. Ag was immobilised using polydopamine as a priming and catalytic layer followed by coating of quercetin that was incorporated in a functionalized polydimethylsiloxane. The coating was investigated using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX) and release assay. The antimicrobial activity of quercetin and Ag was tested against Staphylococcus aureus (S. aureus). A surgical wound model on mice was used to evaluate the effects of the coated dressing on wound healing rates and tissue histology. RESULTS: Ag and quercetin showed enhanced antimicrobial activity against S. aureus when used in combination. Ag and quercetin were successfully immobilized onto the fibre of the dressing using the dip-coating process. The coating released Ag and quercetin over 8 days and showed strong antioxidant activity. In the wound healing model, complete wound closure was achieved in 12 days in the group receiving coated dressing and was associated with an enhancement in tissue remodelling and neo-angiogenesis and the reduction in tissue inflammation. CONCLUSION: These new antimicrobial-antioxidant coatings may be promising in the development of advanced wound care therapies.


Assuntos
Antibacterianos/farmacologia , Antioxidantes/farmacologia , Bandagens , Quercetina/farmacologia , Prata/farmacologia , Cicatrização/efeitos dos fármacos , Animais , Antioxidantes/química , Liberação Controlada de Fármacos , Indóis/química , Camundongos , Microscopia Eletrônica de Varredura , Polímeros/química , Quercetina/química , Silicones/química , Staphylococcus aureus/efeitos dos fármacos , Infecção dos Ferimentos/prevenção & controle
5.
Nat Biotechnol ; 34(3): 320-7, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26854476

RESUMO

High-fidelity intracranial electrode arrays for recording and stimulating brain activity have facilitated major advances in the treatment of neurological conditions over the past decade. Traditional arrays require direct implantation into the brain via open craniotomy, which can lead to inflammatory tissue responses, necessitating development of minimally invasive approaches that avoid brain trauma. Here we demonstrate the feasibility of chronically recording brain activity from within a vein using a passive stent-electrode recording array (stentrode). We achieved implantation into a superficial cortical vein overlying the motor cortex via catheter angiography and demonstrate neural recordings in freely moving sheep for up to 190 d. Spectral content and bandwidth of vascular electrocorticography were comparable to those of recordings from epidural surface arrays. Venous internal lumen patency was maintained for the duration of implantation. Stentrodes may have wide ranging applications as a neural interface for treatment of a range of neurological conditions.


Assuntos
Procedimentos Endovasculares , Córtex Motor/fisiologia , Neurônios/fisiologia , Stents , Animais , Catéteres , Angiografia Cerebral/métodos , Eletrodos , Humanos , Ovinos
6.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 4463-4466, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28269269

RESUMO

A major challenge facing neural prostheses is the development of electrodes that are well tolerated by the brain and body. A novel way to circumvent the need to perform an invasive craniotomy and penetration of the blood-brain barrier to implant electrodes, is to guide electrodes up into the cerebral veins and place electrodes on the vessel walls adjacent to neuronal populations. To aid in the development of these stent based devices, microelectrodes manufactured from Nitinol would allow electrodes to be implanted via a catheter and then once deployed, alter their shape to conform to the vessel walls. However, there is a paucity of data on whether Nitinol is a suitable material to record neural signals. Here we show that Nitinol is tolerated by the body and that it can effectively measure neural signals. Specifically, we electrochemically evaluate Nitinol electrodes in blood and record visually evoked potentials from sheep.


Assuntos
Ligas , Córtex Cerebral/fisiologia , Potenciais Evocados Visuais , Próteses Neurais , Monitorização Neurofisiológica/instrumentação , Animais , Vasos Sanguíneos , Procedimentos Endovasculares , Microeletrodos , Ovinos , Stents