Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 150
Filtrar
1.
Graefes Arch Clin Exp Ophthalmol ; 261(10): 2935-2944, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37247002

RESUMO

PURPOSE: To evaluate the outcomes of micropulse transscleral laser therapy (MP-TLT) in patients with uncontrolled glaucoma and prior glaucoma aqueous tube shunt. METHODS: In this single­center, retrospective, interventional case series, eyes that underwent MP-TLT and had prior glaucoma aqueous tube shunt surgeries were included. The Cyclo Glaucoma Laser System (IRIDEX Corporation, Mountain View, CA, USA) with the MicroPulse P3 probe (version 1) was used. Post­operative data were collected at day 1, week 1, and months 1, 3, 6, 12, 18, 24, 30 and 36. RESULTS: A total of 84 eyes (84 patients) with mean age of 65.8 ± 15.2 years and with advanced glaucoma (baseline mean deviation -16.25 ± 6.80 dB and best-corrected visual acuity 0.82 ± 0.83 logMar) were included in the study. Baseline mean IOP was 19.95 ± 5.6 mm Hg with a mean number of medications 3.39 ± 1.02. There were statistically significant differences in IOP between baseline and all follow-up visits (p < 0.01 for all). The mean percentage of IOP reduction between baseline and different follow-up visits ranged from 23.4% to 35.5% (p < 0.01). There was a significant reduction of visual acuity (≥ 2-lines) at 1 year (30.3%) and 2 years (76.78%). There was a statistically significant reduction in the number of glaucoma medications between baseline and all follow-up visits after postoperative week 1 (p < 0.05 for all). No severe complications including persistent hypotony and related complications were observed. At the last follow-up visit, only 24 (28%) eyes out of 84 eyes remained in the study. CONCLUSION: MP-TLT is an effective treatment for reducing IOP and decreasing the number of medications in patients with advanced glaucoma and prior glaucoma aqueous tube shunt.


Assuntos
Glaucoma , Terapia a Laser , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Pressão Intraocular , Estudos Retrospectivos , Fotocoagulação a Laser , Corpo Ciliar/cirurgia , Glaucoma/cirurgia , Resultado do Tratamento , Esclera/cirurgia
2.
Clin Ophthalmol ; 17: 25-46, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36660309

RESUMO

The Xen gel stent (Allergan Inc, an AbbVie company; Dublin, Ireland) was conceived as an option for patients requiring modest IOP reduction but for whom trabeculectomy was not yet indicated. As with any glaucoma surgery, establishing criteria for patient selection and identifying factors that contribute to a high likelihood of success are important. To help guide clinical decision-making, a systematic review of published studies on the gel stent was performed, with the goal of understanding postoperative outcomes based on clinical and patient factors. Results were organized around a series of pertinent clinical questions based on scenarios encountered in clinical practice. Criteria for including studies were intentionally broad, with the objective of simulating the diverse population of glaucoma patients encountered in real-world practice. Outcomes for IOP and medication reduction postoperatively were assessed in various analyses, including in eyes with various glaucoma types and severity; in eyes naïve to surgery as well as those with a history of prior incisional glaucoma surgery; and when surgery was performed as a standalone procedure or at the time of cataract surgery. The results of each of the various analyses were consistent in demonstrating that successful gel stent surgery achieved a postoperative IOP of approximately 14.0 mm Hg and reduction to fewer than 1 glaucoma medication. Additional data are shown on outcomes by method of implant (ab interno vs ab externo); intraoperative use of antifibrotics; and rates of needling in published studies.

3.
Clin Ophthalmol ; 17: 71-83, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36636622

RESUMO

Purpose: To provide expert consensus and evidence-based current guidelines on treatment technique, postoperative care, expected outcomes and retreatment for MicroPulse Transscleral Laser Treatment (TLT). Methods: A comprehensive search of PubMed led to the identification and analysis of 61 studies on MicroPulse TLT. To provide guidance in areas where there was not enough available literature, a three-round Delphi method was conducted involving 10 international experts in MicroPulse TLT. Results: The response rate was 70% in the first round, 70% in the second round, and 80% in the third round of the Delphi method. Once all responses were aggregated, a live meeting was held with 90% attendance, and consensus was achieved on each of the findings detailed in this manuscript. Conclusion: Used within appropriate treatment parameters, with proper technique and patient selection, MicroPulse TLT is a safe and effective treatment for many types and severities of glaucoma. MicroPulse TLT represents a useful addition to the glaucoma armamentarium.

4.
J Glaucoma ; 32(2): e3-e10, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36222877

RESUMO

We discuss how ophthalmic endoscopy was used in the management of 6 cases with atypical uveitis glaucoma hyphema syndrome. For case 1, the endoscope was used to remove a retained haptic foreign body after an intraocular lens (IOL) exchange with an iris-sutured IOL for a complete capsular bag-IOL complex dislocation. In case 2, the endoscope was key in identifying the presence and location of vascular lesions at the site of previous pars plana sclerotomies. In case 3, the endoscope enabled visualization of a large segmental Soemmering's Ring pushing a 3-piece IOL haptic into the posterior iris. For case 4, the endoscope allowed viewing of the sharp edge of the optic where the haptic of a one-piece lens had been amputated, and the sharp edge of the cut optic was anteriorly oriented and continuing to rub the posterior iris. In case 5, the endoscope confirmed the presence of 1 haptic of a 1-piece lens out of the capsular bag and in the sulcus space. Also, it showed that the capsular bag had inadequate zonular support to attempt repositioning the haptic into the bag. In case 6, the endoscope was helpful in identifying a 1-piece plate haptic IOL in the sulcus, with synechiae and anterior location causing iris bulging inferiorly.


Assuntos
Glaucoma de Ângulo Aberto , Doenças do Cristalino , Lentes Intraoculares , Uveíte , Humanos , Implante de Lente Intraocular/efeitos adversos , Hifema/diagnóstico , Hifema/etiologia , Hifema/cirurgia , Complicações Pós-Operatórias , Pressão Intraocular , Lentes Intraoculares/efeitos adversos , Uveíte/complicações , Uveíte/diagnóstico , Uveíte/cirurgia , Glaucoma de Ângulo Aberto/complicações , Endoscopia/efeitos adversos
5.
Clin Ophthalmol ; 16: 1837-1846, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35698599

RESUMO

Purpose: To provide consensus-based current guidelines on optimal dosimetry and patient selection for MicroPulse Transscleral Laser Therapy (TLT) based on a review of the literature and a Delphi method. Methods: A comprehensive search of Pub Med led to the identification and analysis of 61 studies on MicroPulse TLT that contained information on laser settings and patient selection. To determine consensus in areas where there was not enough available literature, a three-round Delphi method was conducted. Results: The response rate was 90% in the first round, 90% in the second round, and 80% in the third round of the Delphi technique. Once all responses were aggregated, a live meeting was held with 80% attendance, and consensus was achieved on each of the findings detailed in this manuscript. Conclusion: Micropulse TLT is a useful addition to the glaucoma armamentarium. When used with proper surgical technique at energy settings within the boundaries described in this manuscript, MicroPulse TLT is a safe and effective treatment for many types and stages of glaucoma. Based on current knowledge and experience, the consensus recommendation of this expert panel is that the standard MicroPulse TLT settings using the revised MicroPulse P3 Probe should be 2500 mW, 31.3% duty cycle, and 4 sweeps at a sweep velocity of 20 seconds each per hemisphere. Both hemispheres avoiding the 3 and 9 clock hours should be treated. The panel also reached consensus on patient selection for MicroPulse TLT providing guidance for the use of the procedure.

6.
Graefes Arch Clin Exp Ophthalmol ; 260(1): 265-270, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34379186

RESUMO

PURPOSE: To investigate the applicability of ISNT (inferior ≥ superior ≥ nasal ≥ temporal), IST (inferior ≥ superior ≥ temporal), and T min (temporal quadrant with the minimum value) rules to the peripapillary nerve fiber layer (NFL) thickness and radial peripapillary capillary (RPC) vessel density (VD) using Optical Coherence Tomography (OCT) and OCT angiography (OCT-A). MATERIALS AND METHODS: This cross-sectional study included 134 eyes of 74 healthy individuals. NFL thickness and RPC VD were measured in all four quadrants using OCT and OCT-A in order to determine the number of eyes that obey the ISNT, IST, and T min rules. RESULTS: Mean age was 48.8 ± 15.5 (range 25-82) years. The ISNT rule was valid in 52 eyes (38.81%) on OCT and only 12 eyes (8.95%) on OCT-A scans. The IST rule was followed by 83 (61.94%) and 37 (27.61%) eyes on OCT and OCT-A scans respectively. The T min rule was valid in 86 eyes (64.18%) in OCT scans and in 26 eyes (19.4%) in OCT-A scans. CONCLUSION: The topography of the RPC network does not obey the ISNT rule in healthy eyes. The ISNT rule and its variants were found to be more relevant in OCT NFL thickness measurements compared to OCT-A RPC VD measurements.


Assuntos
Disco Óptico , Tomografia de Coerência Óptica , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Angiofluoresceinografia , Humanos , Pessoa de Meia-Idade , Fibras Nervosas , Células Ganglionares da Retina , Vasos Retinianos/diagnóstico por imagem
8.
J Cataract Refract Surg ; 46(10): 1422-1432, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32657904

RESUMO

Minimally invasive glaucoma surgery (MIGS) has become a reliable standard of care for the treatment of glaucoma when combined with cataract surgery. This review describes the MIGS procedures currently combined with and without cataract surgery with a focus on visual outcomes based on the literature and the experience of the ASCRS Glaucoma Clinical Committee.


Assuntos
Extração de Catarata , Catarata , Glaucoma , Glaucoma/cirurgia , Humanos , Pressão Intraocular , Procedimentos Cirúrgicos Minimamente Invasivos
10.
Exp Eye Res ; 196: 108064, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32439396

RESUMO

This work sought to compare aqueous angiographic segmental patterns with bead-based methods which directly visualize segmental trabecular meshwork (TM) tracer trapping. Additionally, segmental protein expression differences between aqueous angiographic-derived low- and high-outflow human TM regions were evaluated. Post-mortem human eyes (One Legacy and San Diego eye banks; n = 15) were perfused with fluorescent tracers (fluorescein [2.5%], indocyanine green [0.4%], and/or fluorescent microspheres). After angiographic imaging (Spectralis HRA+OCT; Heidelberg Engineering), peri-limbal low- and high-angiographic flow regions were marked. Aqueous angiographic segmental outflow patterns were similar to fluorescent microsphere TM trapping segmental patterns. TM was dissected from low- and high-flow areas and processed for immunofluorescence or Western blot and compared. Versican expression was relatively elevated in low-flow regions while MMP3 and collagen VI were relatively elevated in high-flow regions. TGF-ß2, thrombospondin-1, TGF-ß receptor1, and TGF-ß downstream proteins such as α-smooth muscle actin were relatively elevated in low-flow regions. Additionally, fibronectin (FN) levels were unchanged, but the EDA isoform (FN-EDA) that is associated with fibrosis was relatively elevated in low-flow regions. These results show that segmental aqueous angiographic patterns are reflective of underlying TM molecular characteristics and demonstrate increased pro-fibrotic activation in low-flow regions. Thus, we provide evidence that aqueous angiography outflow visualization, the only tracer outflow imaging method available to clinicians, is in part representative of TM biology.


Assuntos
Humor Aquoso/fisiologia , Malha Trabecular/metabolismo , Actinas/metabolismo , Angiografia , Western Blotting , Colágeno Tipo VI/metabolismo , Fibronectinas/metabolismo , Fluoresceína/metabolismo , Humanos , Pressão Intraocular , Metaloproteinase 3 da Matriz/metabolismo , Microscopia Confocal , Microscopia de Fluorescência , Microesferas , Malha Trabecular/diagnóstico por imagem , Fator de Crescimento Transformador beta/metabolismo , Versicanas/metabolismo
11.
J Glaucoma ; 29(8): 627-638, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32459684

RESUMO

PURPOSE: The purpose of this study was to evaluate the efficacy of intraocular pressure (IOP) control after combined CyPass Micro-Stent implantation and cataract surgery (combined surgery). METHODS: All cases of combined surgery performed from February 2017 to July 2018 at Stein and Doheny Eye Institutes were reviewed. The primary outcome was a qualified success with stratified IOP targets based on criteria: final IOP (A) ≤18 mm Hg and reduction of 20%, (B) ≤15 mm Hg and reduction of 25%, (C) ≤12 mm Hg and reduction of 30%. Secondary outcome measures included postoperative IOP and number of medications, complications, additional glaucoma surgery, and postoperative refractive error. Predictive factors for failure were investigated. IOP spike was defined as a postoperative IOP ≥30 or >10 mm Hg increase from preoperative IOP. RESULTS: One hundred forty-one eyes (107 patients) were included. Mean (±SD) preoperative IOP was 15.4±3.4 mm Hg on an average of 2.2±1.1 medications. A statistically significant reduction in IOP and number of medications was seen at 12 months (13.8±4.2 mm Hg, 1.3±1.3 medications, P<0.001). Fifteen eyes (10.6%) had a postoperative IOP spike. Thirteen eyes (9.2%) experienced 17 complications (12.1%). Additional glaucoma surgery was performed in 3 eyes (2 patients). Cumulative success rates at 1 year based on criteria A, B, and C were 42%, 33%, and 28%, respectively. Lower preoperative IOP, greater preoperative medication number, the occurrence of postoperative IOP spike, and non-Caucasian ethnicity were associated with failure. CONCLUSION: Combined CyPass Micro-Stent implantation and cataract surgery may reduce glaucoma medication burden with a success rate of 28% to 42% at 1 year.


Assuntos
Corioide/cirurgia , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto/cirurgia , Facoemulsificação , Implantação de Prótese , Idoso , Idoso de 80 Anos ou mais , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Estudos Retrospectivos , Stents , Tonometria Ocular
12.
Graefes Arch Clin Exp Ophthalmol ; 258(7): 1475-1481, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32215725

RESUMO

PURPOSE: To compare the reproducibility and agreement of anterior chamber angle (ACA) parameters and metrics obtained by four different anterior segment-optical coherence tomography (AS-OCT) devices. METHODS: In this prospective study, 30 eyes from 15 normal subjects underwent anterior segment angle scanning using the Spectralis, Cirrus, and Optovue spectral domain optical coherence tomography (SD-OCT), as well as the Visante time-domain optical coherence tomography (TD-OCT). For each eye, the scan line was performed perpendicularly on the inferior (270°) angle, and the inferior ACA image was acquired 2 times. Inter-instrument and intra-instrument, as well as inter-observer and intra-observer reproducibility of anterior chamber angle metrics, Schwalbe's line (SL) to scleral spur (SS) distance (TM-Span), angle opening distance (AOD), and trabecular iris space area (TISA) measurements, were evaluated by intraclass correlation coefficients (ICCs) and Bland-Altman plots with limits of agreement (LoA). RESULTS: For this cohort of 30 eyes of 15 normal subjects, the mean TM-Span, AOD, and TISA were 0.966 ± 0.198 mm, 0.750 ± 0.205 mm, and 0.286 ± 0.090 mm2 from the Spectralis; 0.929 ± 0.113 mm, 0.717 ± 0.120 mm, and 0.267 ± 0.095 mm2 from the Cirrus; 0.923 ± 0.191 mm, 0.683 ± 0.161 mm, and 0.265 ± 0.072 mm2 from the Optovue; and 0.970 ± 0.070 mm, 0.705 ± 0.150 mm, and 0.279 ± 0.065 mm2 from the Visante. The intra-instrument (ICCs > 0.838), intra-grader (ICCs > 0.910), and inter-grader (ICCs > 0.869) agreement were good. Agreement between the four instruments was also good with ICCs from 0.901 to 0.967 for TM-Span, 0.887 to 0.941 for AOD, and 0.923 to 0.961 for TISA. CONCLUSIONS: Consistent and reproducible ACA measurements could be obtained from multiple AS-OCT devices including both SD- and TD-OCT instruments. These findings have relevance when considering multiple imaging devices in future studies.


Assuntos
Segmento Anterior do Olho/diagnóstico por imagem , Tomografia de Coerência Óptica/instrumentação , Adulto , Câmara Anterior/diagnóstico por imagem , Desenho de Equipamento , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
13.
Adv Ther ; 37(5): 2538-2549, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32200534

RESUMO

The Xen Gel Stent lowers intraocular pressure by shunting aqueous humor to the subconjunctival space. While published studies include both open conjunctiva and closed conjunctiva approaches, most publications feature a closed conjunctiva, ab interno approach. While this approach is widely used, other approaches may be preferred for some patients. This paper provides details on surgical steps and tips for enhancing outcomes for an open conjunctiva technique for the implantation of the Xen Gel Stent, as well as reasoning as to when this approach should be used.


Assuntos
Túnica Conjuntiva/cirurgia , Implantes para Drenagem de Glaucoma , Procedimentos Cirúrgicos Oftalmológicos/métodos , Humor Aquoso , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Pressão Intraocular , Tonometria Ocular
14.
Atten Percept Psychophys ; 82(4): 1949-1970, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-31898071

RESUMO

Cross-sensory correspondences can reflect crosstalk between aligned conceptual feature dimensions, though uncertainty remains regarding the identities of all the dimensions involved. It is unclear, for example, if heaviness contributes to correspondences separately from size. Taking steps to dissociate variations in heaviness from variations in size, the question was asked if a heaviness-brightness correspondence will induce a congruity effect during the speeded brightness classification of simple visual stimuli. Participants classified the stimuli according to whether they were brighter or darker than the mid-gray background against which they appeared. They registered their speeded decisions by manipulating (e.g., tapping) the object they were holding in either their left or right hand (e.g., left for bright, right for dark). With these two otherwise identical objects contrasting in their weight, stimuli were classified more quickly when the relative heaviness of the object needing to be manipulated corresponded with the brightness of the stimulus being classified (e.g., the heavier object for a darker stimulus). This novel congruity effect, in the guise of a stimulus-response (S-R) compatibility effect, was induced when heaviness was isolated as an enduring feature of the object needing to be manipulated. It was also undiminished when participants completed a concurrent verbal memory load task, countering claims that the heaviness-brightness correspondence is verbally mediated. Heaviness, alongside size, appears to contribute to cross-sensory correspondences in its own right and in a manner confirming the far-reaching influence of correspondences, extending here to the fluency with which people communicate simple ideas by manipulating a hand-held object.


Assuntos
Percepção Visual , Humanos
15.
Clin Exp Ophthalmol ; 48(1): 31-36, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31505089

RESUMO

IMPORTANCE: To evaluate the safety and efficacy of ab interno trabeculotomy (AIT) (trabecular ablation) with the trabectome in patients with uveitic glaucoma. BACKGROUND: Traditional glaucoma filtration surgeries in the uveitic patient population come with a higher risk of complications such as failure and hypotony. DESIGN: Retrospective observational cohort study. PARTICIPANTS: All patients diagnosed with uveitic glaucoma were included in this study. Patients were excluded if they have less than 12 months of follow-up. METHODS: All patients who received AIT alone or combined with phacoemulsification. MAIN OUTCOME MEASURES: Major outcomes include intraocular pressure (IOP), number of glaucoma medications and secondary glaucoma surgery, if any. Kaplan-Meier method was used for survival analysis and success was defined as IOP ≤21 mmHg, at least 20% IOP reduction from baseline for any two consecutive visits after 3 months, no additional glaucoma medications, and no secondary glaucoma surgery. RESULTS: A total of 45 eyes, 45 patients, with an average age of 52 years were included in the study. The majority were Japanese (40%) and underwent AIT alone (71%). IOP was reduced from 29.2 ± 8.0 to 16.7 ± 4.6 mmHg at 12 months (P < .01*), while the number of glaucoma medications was reduced from 4.0 ± 1.0 to 2.5 ± 1.6 (P < .01*). Survival rate at 12 months was 91%. Six cases required secondary glaucoma surgery and no other serious complication were reported. CONCLUSIONS AND RELEVANCE: The trabectome AIT procedure appears to be effective in reducing IOP in uveitic glaucoma patients. Although no statistically significant difference was found in the number of glaucoma medications, a decreasing trend was found.


Assuntos
Glaucoma de Ângulo Aberto/cirurgia , Malha Trabecular/cirurgia , Trabeculectomia/métodos , Uveíte Anterior/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anti-Hipertensivos/administração & dosagem , Criança , Estudos de Coortes , Feminino , Glaucoma de Ângulo Aberto/etiologia , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Estudos Retrospectivos , Tonometria Ocular , Trabeculectomia/instrumentação , Resultado do Tratamento , Uveíte Anterior/complicações , Uveíte Anterior/fisiopatologia , Campos Visuais/fisiologia
16.
Sci Rep ; 9(1): 18528, 2019 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-31811166

RESUMO

To construct an optical coherence tomography (OCT) nerve fiber layer (NFL) parameter that has maximal correlation and agreement with visual field (VF) mean deviation (MD). The NFL_MD parameter in dB scale was calculated from the peripapillary NFL thickness profile nonlinear transformation and VF area-weighted averaging. From the Advanced Imaging for Glaucoma study, 245 normal, 420 pre-perimetric glaucoma (PPG), and 289 perimetric glaucoma (PG) eyes were selected. NFL_MD had significantly higher correlation (Pearson R: 0.68 vs 0.55, p < 0.001) with VF_MD than the overall NFL thickness. NFL_MD also had significantly higher sensitivity in detecting PPG (0.14 vs 0.08) and PG (0.60 vs 0.43) at the 99% specificity level. NFL_MD had better reproducibility than VF_MD (0.35 vs 0.69 dB, p < 0.001). The differences between NFL_MD and VF_MD were -0.34 ± 1.71 dB, -0.01 ± 2.08 dB and 3.54 ± 3.18 dB and 7.17 ± 2.68 dB for PPG, early PG, moderate PG, and severe PG subgroups, respectively. In summary, OCT-based NFL_MD has better correlation with VF_MD and greater diagnostic sensitivity than the average NFL thickness. It has better reproducibility than VF_MD, which may be advantageous in detecting progression. It agrees well with VF_MD in early glaucoma but underestimates damage in moderate~advanced stages.


Assuntos
Glaucoma/diagnóstico , Disco Óptico/diagnóstico por imagem , Tomografia de Coerência Óptica , Testes de Campo Visual/métodos , Campos Visuais/fisiologia , Idoso , Estudos de Viabilidade , Feminino , Glaucoma/patologia , Glaucoma/fisiopatologia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Disco Óptico/patologia , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Am J Ophthalmol ; 202: 62-71, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30794787

RESUMO

PURPOSE: To investigate predictive factors associated with the rate of visual field (VF) loss in open-angle glaucoma. DESIGN: Prospective multicenter cohort study. METHODS: Perimetric glaucoma patients of the Advanced Imaging for Glaucoma study were selected for analysis if they had 9 completed visits. Confirmed rapid significant progression (CRSP) of VF was defined as a significant (P < 0.05) negative VF index (VFI) slope of -1%/year or a mean deviation slope of -0.5 dB/year, confirmed at 2 consecutive follow-up visits. Slow progression was defined as VFI slope greater than -0.5%/year or a mean deviation slope of -0.25 dB/year. Fourier-domain optical coherence tomography (FD-OCT) measured optic disc, peripapillary retinal nerve fiber layer (NFL), and macular ganglion cell complex (GCC) thicknesses. Logistic regression was used to identify baseline predictors for CRSP and slow progression. Linear regression was used to identify baseline predictors for the VFI and mean deviation slope. RESULTS: Eyes (n = 150) of 103 participants were included. Slow progression was observed in 80 eyes (53.3%) and CRSP in 23 eyes (15.3%). Larger NFL and GCC baseline focal loss volume (FLV), thinner central corneal thickness, and lower VFI were significant (P < 0.05) baseline predictors of more rapid progression on univariate analysis. The predictor with the highest odds ratio (OR) was NFL-FLV, which was also the most significant non-VF predictor in the multivariate analysis. Eyes with NFL-FLV >8.5% had an OR of 2.67 for CRSP and 0.42 for slow progression. Disc hemorrhage during the follow-up was also important, with an OR of 2.61 for CRSP and 0.23 for slow progression for each occurrence. CONCLUSIONS: Focal loss measured by FD-OCT or VF along with CCT are strong baseline predictors for the rate of glaucoma progression.


Assuntos
Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Disco Óptico/patologia , Doenças do Nervo Óptico/diagnóstico , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Campos Visuais/fisiologia , Progressão da Doença , Feminino , Seguimentos , Análise de Fourier , Glaucoma/complicações , Glaucoma/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Fibras Nervosas/patologia , Oftalmoscopia , Doenças do Nervo Óptico/etiologia , Doenças do Nervo Óptico/fisiopatologia , Prognóstico , Estudos Prospectivos , Fatores de Tempo , Tonometria Ocular , Testes de Campo Visual
18.
Ophthalmol Glaucoma ; 2(4): 215-223, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32672541

RESUMO

PURPOSE: Obtaining slit-lamp gonioscopic images requires a high level of expertise and can be time consuming. The images typically are limited to 4 quadrants with limited resolution and can be affected by different lighting conditions. Our goal was to study the ability of the novel imaging system to quickly and easily document the full 360 degrees of the anterior chamber angle in a standardized manner. DESIGN: Cross-sectional cohort study. SUBJECTS: Eighty-four eyes from 50 subjects were included in this study, including 26 eyes from 17 normal participants and 58 eyes from 33 patients diagnosed with glaucoma. METHODS: A newly introduced, commercially available gonioscope (GS-1, NIDEK Co, Gamagori, Japan) was utilized to perform semiautomated imaging of the full 360-degree iridocorneal angle on participants under an institutional review board-approved study. Topical proparacaine was administered to the eye to anesthetize the eye and imaging was completed using the 16-mirror, machine-attached gonioscopic lens coupled with lubricating ophthalmic gel ointment. The first step of the 2-step image acquisition process is analogous to manual gonioscopy, whereas the second step is performed by the instrument in an automated fashion. First, the instrument is manually moved forward by the operator to allow the machine-attached lens to make contact with the patient's corneal surface (time = 30 seconds). Second, the instrument automatically achieves fine focus on the iridocorneal angle and takes 16 sequential high-resolution photographs at multiple different focal planes (time = less than 30 seconds). MAIN OUTCOME MEASURES: Successful qualitative imaging of anterior chamber iridocorneal angle in normal and glaucomatous eyes including visualization of various implanted devices within angle before and after surgery in less than 1 minute per eye. RESULTS: In this pilot study, the full 360 degrees of iridocorneal angle of 84 eyes from 50 normal participants or glaucoma patients were successfully imaged using NIDEK GS-1 in under 60 seconds. All eyes were able to be imaged in 1 sitting, and we were able to image the full spectrum of angle from narrow/closed to fully open. The 360-degree views of the images were able to be displayed in 3 available formats (16-section display, a circular display, or a linear display). Successful imaging was also achieved of surgical devices and postsurgical conditions including CyPass, iStent, XEN, Baerveldt tube shunt, angle recession with iridodialysis, angle neovascularization, pigment dispersion, posttrabeculectomy sclerostomy and surgical iridectomy, and post-laser peripheral iridotomy. CONCLUSION: The newly introduced, semiautomated imaging system was able to document the full 360-degree iridocorneal angle views in normal and glaucoma eyes in less than 1 minute, which may allow longitudinal evaluation in a standardized manner. Furthermore, this system allows the ability to easily evaluate post-angle surgery changes and assess positions of implanted devices in the anterior chamber angle.


Assuntos
Câmara Anterior/diagnóstico por imagem , Glaucoma de Ângulo Fechado/diagnóstico , Pressão Intraocular/fisiologia , Tomografia de Coerência Óptica/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Glaucoma de Ângulo Fechado/fisiopatologia , Glaucoma de Ângulo Fechado/cirurgia , Humanos , Iridectomia/métodos , Iris/cirurgia , Terapia a Laser/métodos , Masculino , Pessoa de Meia-Idade , Projetos Piloto
19.
Ophthalmol Glaucoma ; 2(6): 413-421, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32672574

RESUMO

PURPOSE: To compare the histologic effects of endoscopic cyclophotocoagulation (ECP) with other ciliary body ablative procedures. A secondary aim was to correlate these findings with historical clinical success and complication rates. DESIGN: Prospective, qualitative comparison of histopathologic tissue analysis. PARTICIPANTS: Two eyes of two patients who had undergone ECP for open-angle glaucoma were studied. Two eyes from a healthy monkey were treated with ECP and studied. For comparison, 1 eye each of patients who had undergone contact and noncontact neodymium:yttrium-aluminum-garnet transscleral cyclophotocoagulation (TCP) for open-angle glaucoma were analyzed. METHODS: The human globes were enucleated and submitted for analysis by gross examination and light and electron microscopy. Monkey eyes were studied by gross examination and light microscopy 1 week, 2 weeks, and 1 month after ECP. MAIN OUTCOME MEASURES: Gross and histopathologic specimens of all eyes were analyzed with respect to location and type of tissue effects and degree of collateral damage. RESULTS: The gross analysis of all ECP specimens showed a uniform anterior-to-posterior whitening of each treated ciliary process. This correlated with microscopic evidence of loss of pigmentation from the pigmented ciliary epithelial cells seen with mostly preserved architecture and vasculature of the ciliary processes. By comparison, the TCP specimens showed erratic treatment of the ciliary processes with overlap into the pars plicata of the ciliary body. Microscopic analysis revealed significant disruption of the cells throughout the ciliary processes and loss of vessels within the stroma. CONCLUSIONS: Treatment with ECP results in less overall tissue destruction and a targeted effect on the pigmented ciliary epithelium of the ciliary processes when compared with TCP.


Assuntos
Corpo Ciliar/cirurgia , Endoscopia/métodos , Glaucoma/cirurgia , Pressão Intraocular/fisiologia , Fotocoagulação a Laser/métodos , Animais , Corpo Ciliar/patologia , Modelos Animais de Doenças , Glaucoma/patologia , Glaucoma/fisiopatologia , Haplorrinos , Humanos
20.
Ophthalmol Glaucoma ; 2(6): 402-412, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32672572

RESUMO

PURPOSE: To assess the short-term efficacy and safety of micropulse transscleral diode laser cyclophotocoagulation (MP-TSCPC) in the management of refractory glaucoma and to compare outcomes based on prior glaucoma surgeries. DESIGN: Retrospective analysis. PARTICIPANTS: Patients with refractory glaucoma who underwent MP-TSCPC at a single institution by 1 of 4 surgeons. METHODS: Chart review of cases of MP-TSCPC using the Iridex Cyclo G6 (Mountain View, CA) laser with standard parameters and laser duration at the discretion of each treating physician. MAIN OUTCOME MEASURES: Probability of postoperative success was estimated by the Kaplan-Meier method. Success parameters included intraocular pressure (IOP) 6 to 21 mmHg with or without topical antihypertensive therapy, 20% or more IOP reduction from baseline for any 2 consecutive visits after 3 postoperative months, and no subsequent glaucoma surgery. RESULTS: One hundred sixteen eyes of 116 patients (mean age, 65.8±16.9 years) were included. Baseline IOP was 22.2±7.9 mmHg, and mean postoperative follow-up time was 6.3±3.4 months (range, 3-12 months.) Postoperative IOP at the final follow up was 15.3±6.6 mmHg (P < 0.01), corresponding to a reduction of approximately 6.9 mmHg (31.1%). Most eyes (66.4%) underwent at least 6 months of follow-up. Short-term probability of success was 93.1% at 3 months and 74.3% at 6 months. Eyes that had undergone prior traditional glaucoma surgery (trabeculectomy, tube shunt, excessive pressure-regulating shunt system miniature glaucoma shunt [Alcon, Fort Worth, TX], or a combination thereof) demonstrated a higher probability of success (67.6%) compared with eyes that had not (41.4%; P = 0.014). The most common complications were decline in best-corrected visual acuity (7.8%) and hypotony (1.7%). CONCLUSIONS: Micropulse transscleral diode laser cyclophotocoagulation has a significant short-term ocular hypotensive effect and favorable safety profile in eyes with refractory glaucoma. The probability of successful outcome was greater in eyes that had undergone prior traditional glaucoma surgery.


Assuntos
Corpo Ciliar/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Pressão Intraocular/fisiologia , Lasers Semicondutores/uso terapêutico , Procedimentos Cirúrgicos Oftalmológicos/métodos , Acuidade Visual , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Fotocoagulação a Laser/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...