Br J Radiol ; 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38588564

RESUMO

OBJECTIVES: To assess the safety and efficacy of percutaneous cryoablation (CA) of soft-tissue tumors (desmoid tumors (DT), vascular malformations (VM), and abdominal wall endometriosis (AWE)). METHODS: This systematic review of studies published before January 2024 encompassed a detailed analysis of CA techniques and technical aspects for the treatment of soft-tissue tumors. Data concerning CA efficacy, complication rates, and other relevant metrics was extracted and included for analysis. RESULTS: The analysis included 27 studies totaling 554 CA procedures. For DT (13 studies, 393 sessions), CA showed an average pain reduction of 79 ± 17% (range: 57-100) and a lesion volume decrease of 71.5 ± 9.8% (range: 44-97). VM (4 studies, 58 sessions) had a 100% technical success rate and an average pain reduction of 72 ± 25% (range: 63-85). The average pain reduction for AWE (6 studies, 103 sessions) was 82 ± 13% (range: 62-100). Overall, the complication rate for CA was low, with minor adverse events (AE) in about 20% of patients and major events in less than 5% of patients. CONCLUSION: Showing substantial efficacy in pain reduction and lesion volume decrease, as well as low incidence of severe AE, CA presents as a highly effective and safe alternative for the treatment of soft-tissue tumors. ADVANCES IN KNOWLEDGE: CA is effective and safe in treating soft-tissue tumors, particularly DT, VM, and AWE.

2.
Diagn Interv Imaging ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38429207

RESUMO

PURPOSE: The purpose of this study was to assess image quality and dose level using a photon-counting CT (PCCT) scanner by comparison with a dual-source CT (DSCT) scanner on virtual monoenergetic images (VMIs) at low energy levels. MATERIALS AND METHODS: A phantom was scanned using a DSCT and a PCCT with a volume CT dose index of 11 mGy, and additionally at 6 mGy and 1.8 mGy for PCCT. Noise power spectrum and task-based transfer function were evaluated from 40 to 70 keV on VMIs to assess noise magnitude and noise texture (fav) and spatial resolution on two iodine inserts (f50), respectively. A detectability index (d') was computed to assess the detection of two contrast-enhanced lesions according to the energy level used. RESULTS: For all energy levels, noise magnitude values were lower with PCCT than with DSCT at 11 and 6 mGy, but greater at 1.8 mGy. fav values were higher with PCCT than with DSCT at 11 mGy (8.6 ± 1.5 [standard deviation [SD]%), similar at 6 mGy (1.6 ± 1.5 [SD]%) and lower at 1.8 mGy (-17.8 ± 2.2 [SD]%). For both inserts, f50 values were higher with PCCT than DSCT at 11- and 6 mGy for all keV levels, except at 6 mGy and 40 keV. d' values were higher with PCCT than with DSCT at 11- and 6 mGy for all keV and both simulated lesions. Similar d' values to those of the DSCT at 11 mGy, were obtained at 2.25 mGy for iodine insert at 2 mg/mL and at 0.96 mGy for iodine insert at 4 mg/mL at 40 keV. CONCLUSION: Compared to DSCT, PCCT reduces noise magnitude and improves noise texture, spatial resolution and detectability on VMIs for all low-keV levels.

3.
Can Assoc Radiol J ; : 8465371241236152, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38444144

RESUMO

Interventional Oncology (IO) stands at the forefront of transformative cancer care, leveraging advanced imaging technologies and innovative interventions. This narrative review explores recent developments within IO, highlighting its potential impact facilitated by artificial intelligence (AI), personalized medicine and imaging innovations. The integration of AI in IO holds promise for accelerating tumour detection and characterization, guiding treatment strategies and refining predictive models. Imaging modalities, including functional MRI, PET and cone beam CT are reshaping imaging and precision. Navigation, fusion imaging, augmented reality and robotics have the potential to revolutionize procedural guidance and offer unparalleled accuracy. New developments are observed in embolization and ablative therapies. The pivotal role of genomics in treatment planning, targeted therapies and biomarkers for treatment response prediction underscore the personalization of IO. Quality of life assessment, minimizing side effects and long-term survivorship care emphasize patient-centred outcomes after IO treatment. The evolving landscape of IO training programs, simulation technologies and workforce competence ensures the field's adaptability. Despite barriers to adoption, synergy between interventional radiologists' proficiency and technological advancements hold promise in cancer care.

7.
Diagn Interv Imaging ; 105(3): 110-117, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37949769

RESUMO

PURPOSE: The purpose of this study was to compare the performance of Precise IQ Engine (PIQE) and Advanced intelligent Clear-IQ Engine (AiCE) algorithms on image-quality according to the dose level in a cardiac computed tomography (CT) protocol. MATERIALS AND METHODS: Acquisitions were performed using the CT ACR 464 phantom at three dose levels (volume CT dose indexes: 7.1/5.2/3.1 mGy) using a prospective cardiac CT protocol. Raw data were reconstructed using the three levels of AiCE and PIQE (Mild, Standard and Strong). The noise power spectrum (NPS) and task-based transfer function (TTF) for bone and acrylic inserts were computed. The detectability index (d') was computed to model the detectability of the coronary lumen (350 Hounsfield units and 4-mm diameter) and non-calcified plaque (40 Hounsfield units and 2-mm diameter). RESULTS: Noise magnitude values were lower with PIQE than with AiCE (-13.4 ± 6.0 [standard deviation (SD)] % for Mild, -20.4 ± 4.0 [SD] % for Standard and -32.6 ± 2.6 [SD] % for Strong levels). The average NPS spatial frequencies shifted towards higher frequencies with PIQE than with AiCE (21.9 ± 3.5 [SD] % for Mild, 20.1 ± 3.0 [SD] % for Standard and 12.5 ± 3.5 [SD] % for Strong levels). The TTF values at fifty percent (f50) values shifted towards higher frequencies with PIQE than with AiCE for acrylic inserts but, for bone inserts, f50 values were found to be close. Whatever the dose and DLR level, d' values of both simulated cardiac lesions were higher with PIQE than with AiCE. For the simulated coronary lumen, d' values were better by 35.1 ± 9.3 (SD) % on average for all dose levels for Mild, 43.2 ± 5.0 (SD) % for Standard, and 62.6 ± 1.2 (SD) % for Strong levels. CONCLUSION: Compared to AiCE, PIQE reduced noise, improved spatial resolution, noise texture and detectability of simulated cardiac lesions. PIQE seems to have a greater potential for dose reduction in cardiac CT acquisition.


Assuntos
Aprendizado Profundo , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Doses de Radiação , Algoritmos , Processamento de Imagem Assistida por Computador , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagens de Fantasmas
8.
Diagnostics (Basel) ; 13(23)2023 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-38066732

RESUMO

Images from 64 patients undergoing an enhanced abdominal-pelvis scan at portal phase in dual-energy CT mode for the diagnosis of colitis or bowel obstruction were retrospectively analyzed. Acquisitions were performed on a third-generation dual-source CT (DSCT) 100/Sn150 kVp. Mixed images were generated, as well as virtual monoenergetic images (VMIs) at 40/50/60/70 keV. Objective image quality was assessed on VMIs and mixed images by measuring contrast, noise and contrast-to-noise ratio (CNR). Noise, smoothing and overall image quality were subjectively analyzed by two radiologists using Likert scales. For both patient groups, the noise decreased significantly according to the energy level from 40 to 60 keV by -47.2 ± 24.0% for bowel obstruction and -50.4 ± 18.2% for colitis. It was similar between 60 and 70 keV (p = 0.475 and 0.059, respectively). Noise values were significantly higher in VMIs than in mixed images, except for 70 keV (p = 0.53 and 0.071, respectively). Similar results were observed for contrast values, with a decrease between 40 and 70 keV of -56.3 ± 7.9% for bowel obstruction -56.2 ± 10.9% for colitis. The maximum CNR value was found at 60 keV compared to other energy levels and mixed images, but there was no significant difference with the other energy levels apart from 70 keV (-9.7 ± 9.8%) for bowel obstruction and 40 keV (-6.6 ± 8.2%) and 70 keV (-5.8 ± 9.2%) for colitis. The VMIs at 60 keV presented higher scores for all criteria for bowel obstruction and colitis, with no significant difference in smoothing score compared to mixed images (p = 0.119 and p = 0.888, respectively).

9.
Cancers (Basel) ; 15(21)2023 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-37958366

RESUMO

Kidney cancer accounts for 3% of adult malignancies and is increasingly detected through advanced imaging techniques, highlighting the need for effective treatment strategies. This retrospective study assessed the safety and efficacy of a new single-probe percutaneous cryoablation system using liquid nitrogen for treating T1a renal cancers. From May 2019 to May 2022, 25 consecutive patients from two academic hospitals, with a median age of 64.8 years [IQR 59; 75.5], underwent cryoablation for 26 T1a renal tumors. These tumors had a median size of 25.3 mm [20; 30.7] and a median RENAL nephrometry score, indicating tumor complexity, of 7 [5; 9]. No major complications arose, but three non-clinically relevant perirenal hematomas were detected on post-procedure CT scans. With a median follow-up of 795 days [573; 1020], the primary local control rate at one month stood was 80.8% (21 out of 26). The five recurrent lesions, which exhibited a higher renal score (p = 0.016), were treated again using cryoablation, achieving a secondary local control rate of 100%. No patient died, and the disease-free survival rate was 92% (23 out of 25). In conclusion, single-probe percutaneous cryoablation emerges as a promising modality for managing small renal masses. Notably, recurrence rates appear influenced by RENAL nephrometry scores, suggesting a need for further research to refine the technique.

10.
Diagnostics (Basel) ; 13(19)2023 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-37835782

RESUMO

The purpose of this study was to compare the quality of low-energy virtual monoenergetic images (VMIs) obtained with three Dual-Energy CT (DECT) platforms according to the phantom diameter. Three sections of the Mercury Phantom 4.0 were scanned on two generations of split-filter CTs (SFCT-1st and SFCT-2nd) and on one Dual-source CT (DSCT). The noise power spectrum (NPS), task-based transfer function (TTF), and detectability index (d') were assessed on VMIs from 40 to 70 keV. The highest noise magnitude values were found with SFCT-1st and noise magnitude was higher with DSCT than with SFCT-2nd for 26 cm (10.2% ± 1.3%) and 31 cm (7.0% ± 2.5%), and the opposite for 36 cm (-4.2% ± 2.5%). The highest average NPS spatial frequencies and TTF values at 50% (f50) values were found with DSCT. For all energy levels, the f50 values were higher with SFCT-2nd than SFCT-1st for 26 cm (3.2% ± 0.4%) and the opposite for 31 cm (-6.9% ± 0.5%) and 36 cm (-5.6% ± 0.7%). The lowest d' values were found with SFCT-1st. For all energy levels, the d' values were lower with DSCT than with SFCT-2nd for 26 cm (-6.2% ± 0.7%), similar for 31 cm (-0.3% ± 1.9%) and higher for 36 cm (5.4% ± 2.7%). In conclusion, compared to SFCT-1st, SFCT-2nd exhibited a lower noise magnitude and higher detectability values. Compared with DSCT, SFCT-2nd had a lower noise magnitude and higher detectability for the 26 cm, but the opposite was true for the 36 cm.

11.
J Pers Med ; 13(10)2023 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-37888075

RESUMO

A wide variety of coils are available for vascular embolization. This study aimed to evaluate the safety and efficacy of a new Prestige coil. We carried out retrospective analysis of a multicenter's registry data collected between February 2022 and November 2022. The choice of embolization agent used to treat peripheral vascular anomalies was left to the investigator's discretion. Patients for whom at least one Prestige coil was used were included in Series 1. All other patients were included in Series 2. Efficacy and safety were evaluated. Patients were followed up for one month. In total, 220 patients were included, 110 in each series. Patients included 149 men (67.7%) and 71 women (32.3%), with a median age of 62.5 years (IQR: 35.8-73). Patient ages were similar in the two series. Complete occlusion of the targeted vessel was reported in 96.4% (n = 106/110) of patients in Series 1 and in 99.7% (n = 109/110) in Series 2. Four patients experienced non-serious adverse events (1.8%, n = 4/220): one experienced back pain and one vomiting in Series 1; one patient had off-target embolization and one a puncture site hematoma in Series 2. Sixteen patients (7.2%, n = 16/220) were lost to follow up. Improvement in the patient's general state at one month was reported in 79.0% (n = 83/105) of patients in Series 1 and in 74.7% (n = 74/99) in Series 2. Ten deaths occurred, five in Series 1 (4.8%, n = 5/105) and five in Series 2 (5.1%, n = 5/99). These deaths all concerned critically ill patients embolized for emergent arterial bleeding. In conclusion, the 1-month follow-up showed that Prestige coils, alone or in combination, are efficient and safe.

12.
Med Phys ; 50(11): 6828-6835, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37672341

RESUMO

BACKGROUND: Recently, a second generation of split filter dual-energy CT (SFCT) platform has been developed. The thicknesses of the gold and tin filters used to obtain both low- and high-energy spectra have been changed. These differences in filter thickness may affect the spectral separation between the two spectra and thus the quality of spectral images. PURPOSE: To compare the spectral performance of two Split-Filter Dual-Energy CT systems (SFCT-1st and SFCT-2nd ) on virtual monoenergetic images (VMIs) and iodine map. METHODS: A Multi-Energy CT phantom was scanned on two SFCT with a tube voltage of 120 kVp for both systems (SFCT-1st -120 and SFCT-2nd -120) and 140 kVp only for the second generation (SFCT-2nd -140). Acquisitions were performed on the phantom with a CTDIvol close to 11 mGy. Noise power spectrum (NPS) and task-based transfer function (TTF) were evaluated on VMIs from 40 to 70 keV. A detectability index (d') was computed to assess the detection of two contrast-enhanced lesions on VMIs. Hounsfield Unit (HU) accuracy was assessed on VMIs and the accuracy of iodine concentration was assessed on iodine maps. RESULTS: For all keV, noise magnitude values were lower with the SFCT-2nd -120 than with the SFCT-1st -120 (on average: -22.5 ± 2.9%) and higher with the SFCT-2nd -140 than with the SFCT-2nd -120 (on average: 25.0 ± 6.2%). Average NPS spatial frequencies (fav ) were lower with the SFCT-1st -120 than with the SFCT-2nd -120 (-6.0 ± 0.5%) and the SFCT-2nd -140 (-3.6 ± 1.6%). Similar TTF50% values were found for both systems and both kVp for blood and iodine inserts at 2 mg/mL (0.29 ± 0.01 mm-1 ) and at 4 mg/mL (0.31 ± 0.01 mm-1 ). d' values peaked at 40 keV for the SFCT-2nd and at 70 keV for the SFCT-1st . Highest d' values were found for the SFCT-2nd -120 for both simulated lesions. Accuracy of HU values and iodine concentration was higher with the SFCT-2nd than with the SFCT 1st . CONCLUSION: Compared to the SFCT-1st , with similar spatial resolution and noise texture values, the SFCT-2nd -120 exhibited the lowest values for noise magnitude, the highest detectability index values, and more accurate HU values and iodine concentrations.


Assuntos
Iodo , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas
13.
J Pers Med ; 13(7)2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37511744

RESUMO

The field of vascular interventional radiology has witnessed remarkable advancements, transforming the landscape of patient care for both vascular and non-vascular pathologies [...].

14.
Lancet Reg Health Eur ; 31: 100672, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37415648

RESUMO

Background: Prostatic artery embolisation (PAE) is a minimally invasive treatment of symptomatic benign prostatic hyperplasia (BPH). Our aim was to compare patient's symptoms improvement after PAE and medical treatment. Methods: A randomised, open-label, superiority trial was set in 10 French hospitals. Patients with bothersome lower urinary tract symptoms (LUTS) defined by International Prostatic Symptom Score (IPSS) > 11 and quality of life (QoL) > 3, and BPH ≥50 ml resistant to alpha-blocker monotherapy were randomly assigned (1:1) to PAE or Combined Therapy ([CT], oral dutasteride 0.5 mg/tamsulosin hydrochloride 0.4 mg per day). Randomisation was stratified by centre, IPSS and prostate volume with a minimisation procedure. The primary outcome was the 9-month IPSS change. Primary and safety analysis were done according to the intention-to-treat (ITT) principle among patients with an evaluable primary outcome. ClinicalTrials.gov Identifier: NCT02869971. Findings: Ninety patients were randomised from September 2016 to February 2020, and 44 and 43 patients assessed for primary endpoint in PAE and CT groups, respectively. The 9-month change of IPSS was -10.0 (95% confidence interval [CI]: -11.8 to -8.3) and -5.7 (95% CI: -7.5 to -3.8) in the PAE and CT groups, respectively. This reduction was significantly greater in the PAE group than in the CT group (-4.4 [95% CI: -6.9 to -1.9], p = 0.0008). The IIEF-15 score change was 8.2 (95% CI: 2.9-13.5) and -2.8 (95% CI: -8.4 to 2.8) in the PAE and CT groups, respectively. No treatment-related AE or hospitalisation was noticed. After 9 months, 5 and 18 patients had invasive prostate re-treatment in the PAE and CT group, respectively. Interpretation: In patients with BPH ≥50 ml and bothersome LUTS resistant to alpha-blocker monotherapy, PAE provides more urinary and sexual symptoms benefit than CT up to 24 months. Funding: French Ministry of Health and a complementary grant from Merit Medical.

16.
Diagn Interv Imaging ; 104(10): 506-512, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37286462

RESUMO

PURPOSE: The purpose of this study was to assess the impact of a tin filter on the image quality of ultra-low dose (ULD) chest computed tomography (CT) on three different CT systems. MATERIALS AND METHODS: An image quality phantom was scanned on three CT systems including two split-filter dual-energy CT (SFCT-1 and SFCT-2) scanners and one dual-source CT scanner (DSCT). Acquisitions were performed with a volume CT dose index (CTDIvol) of 0.4 mGy, first at 100 kVp without tin filter (Sn), and second, at Sn100/Sn140 kVp, Sn100/Sn110/Sn120/Sn130/Sn140/Sn150 kVp and Sn100/Sn150 kVp for SFCT-1, SFCT-2 and DSCT respectively. Noise-power-spectrum and task-based transfer function were computed. The detectability index (d') was computed to model the detection of two chest lesions. RESULTS: For DSCT and SFCT-1, noise magnitude values were higher with 100kVp than with Sn100 kVp and with Sn140 kVp or Sn150 kVp than with Sn100 kVp. For SFCT-2, noise magnitude increased from Sn110 kVp to Sn150 kVp and was higher at Sn100 kVp than at Sn110 kVp. For most kVp with the tin filter, the noise amplitude values were lower than those obtained at 100 kVp. For each CT system, noise texture and spatial resolution values were similar with 100 kVp and with all kVp used with a tin filter. For all simulated chest lesions, the highest d' values were obtained at Sn100 kVp for SFCT-1 and DSCT and at Sn110 kVp for SFCT-2. CONCLUSION: For ULD chest CT protocols, the lowest noise magnitude and highest detectability values for simulated chest lesions are obtained with Sn100 kVp for the SFCT-1 and DSCT CT systems and at Sn110 kVp for SFCT-2.


Assuntos
Estanho , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Tórax , Tomógrafos Computadorizados , Imagens de Fantasmas
17.
J Pers Med ; 13(6)2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37373879

RESUMO

The spleen is the most commonly injured organ in blunt abdominal trauma. Its management depends on hemodynamic stability. According to the American Association for the Surgery of Trauma-Organ Injury Scale (AAST-OIS ≥ 3), stable patients with high-grade splenic injuries may benefit from preventive proximal splenic artery embolization (PPSAE). This ancillary study, using the SPLASH multicenter randomized prospective cohort, evaluated the feasibility, safety, and efficacy of PPSAE in patients with high-grade blunt splenic trauma without vascular anomaly on the initial CT scan. All patients included were over 18 years old, had high-grade splenic trauma (≥AAST-OIS 3 + hemoperitoneum) without vascular anomaly on the initial CT scan, received PPSAE, and had a CT scan at one month. Technical aspects, efficacy, and one-month splenic salvage were studied. Fifty-seven patients were reviewed. Technical efficacy was 94% with only four proximal embolization failures due to distal coil migration. Six patients (10.5%) underwent combined embolization (distal + proximal) due to active bleeding or focal arterial anomaly discovered during embolization. The mean procedure time was 56.5 min (SD = 38.1 min). Embolization was performed with an Amplatzer™ vascular plug in 28 patients (49.1%), a Penumbra occlusion device in 18 patients (31.6%), and microcoils in 11 patients (19.3%). There were two hematomas (3.5%) at the puncture site without clinical consequences. There were no rescue splenectomies. Two patients were re-embolized, one on Day 6 for an active leak and one on Day 30 for a secondary aneurysm. Primary clinical efficacy was, therefore, 96%. There were no splenic abscesses or pancreatic necroses. The splenic salvage rate on Day 30 was 94%, while only three patients (5.2%) had less than 50% vascularized splenic parenchyma. PPSAE is a rapid, efficient, and safe procedure that can prevent splenectomy in high-grade spleen trauma (AAST-OIS) ≥ 3 with high splenic salvage rates.

18.
Phys Med ; 108: 102558, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36905775

RESUMO

PURPOSE: To compare quantitatively and qualitatively brain image quality acquired in helical and axial modes on two wide collimation CT systems according to the dose level and algorithm used. METHODS: Acquisitions were performed on an image quality and an anthropomorphic phantoms at three dose levels (CTDIvol: 45/35/25 mGy) on two wide collimation CT systems (GE Healthcare and Canon Medical Systems) in axial and helical modes. Raw data were reconstructed using iterative reconstruction (IR) and deep-learning image reconstruction (DLR) algorithms. The noise power spectrum (NPS) was computed on both phantoms and the task-based transfer function (TTF) on the image quality phantom. The subjective quality of images from an anthropomorphic brain phantom was evaluated by two radiologists including overall image quality. RESULTS: For the GE system, noise magnitude and noise texture (average NPS spatial frequency) were lower with DLR than with IR. For the Canon system, noise magnitude values were lower with DLR than with IR for similar noise texture but the opposite was true for spatial resolution. For both CT systems, noise magnitude was lower with the axial mode than with the helical mode for similar noise texture and spatial resolution. Radiologists rated the overall quality of all brain images as "satisfactory for clinical use", whatever the dose level, algorithm or acquisition mode. CONCLUSIONS: Using 16-cm axial acquisition reduces image noise without changing the spatial resolution and image texture compared to helical acquisitions. Axial acquisition can be used in clinical routine for brain CT examinations with an explored length of less than 16 cm.


Assuntos
Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Imagens de Fantasmas , Encéfalo , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
19.
Diagnostics (Basel) ; 13(6)2023 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-36980490

RESUMO

The study's aim was to assess the impact of a deep learning image reconstruction algorithm (Precise Image; DLR) on image quality and liver metastasis conspicuity compared with an iterative reconstruction algorithm (IR). This retrospective study included all consecutive patients with at least one liver metastasis having been diagnosed between December 2021 and February 2022. Images were reconstructed using level 4 of the IR algorithm (i4) and the Standard/Smooth/Smoother levels of the DLR algorithm. Mean attenuation and standard deviation were measured by placing the ROIs in the fat, muscle, healthy liver, and liver tumor. Two radiologists assessed the image noise and image smoothing, overall image quality, and lesion conspicuity using Likert scales. The study included 30 patients (mean age 70.4 ± 9.8 years, 17 men). The mean CTDIvol was 6.3 ± 2.1 mGy, and the mean dose-length product 314.7 ± 105.7 mGy.cm. Compared with i4, the HU values were similar in the DLR algorithm at all levels for all tissues studied. For each tissue, the image noise significantly decreased with DLR compared with i4 (p < 0.01) and significantly decreased from Standard to Smooth (-26 ± 10%; p < 0.01) and from Smooth to Smoother (-37 ± 8%; p < 0.01). The subjective image assessment confirmed that the image noise significantly decreased between i4 and DLR (p < 0.01) and from the Standard to Smoother levels (p < 0.01), but the opposite occurred for the image smoothing. The highest scores for overall image quality and conspicuity were found for the Smooth and Smoother levels.