Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Opt Express ; 13(5): 3056-3079, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-35774305

RESUMO

Every year, more than a million refractive eye surgeries using femtosecond lasers are performed but the intrastromal cutting process remains an area of development. We investigated the mechanisms of laser dissection in cornea by ultra-high-speed photography. We found that the intrastromal bubble forms multiple lobes along the elongated laser plasma and the overlying lobes expand along the corneal lamellae. Videography demonstrated that the cutting process relies on crack propagation in the stroma along the bubble lobes with the crack originating from the pre-existing bubble layer. These insights are important for further improvement of the cutting mechanisms in refractive surgery.

2.
Transl Vis Sci Technol ; 9(10): 22, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-33024615

RESUMO

Purpose: We introduce a novel focus shaping concept for intrastromal corneal dissection that facilitates cleavage along corneal lamellae, and we analyze laser-tissue interactions governing cutting effectiveness and mechanical side effects. Methods: Focus shaping was achieved by a spiral phase plate that converts an incident Gaussian beam into a Laguerre-Gaussian beam with a helical phase. Such vortex beams have zero intensity at their center, are propagation invariant, and possess a ring focus equal in length to the Gaussian focus but with a larger diameter. Cutting precision and the required absorbed energy for flap dissection were compared for Gaussian and vortex beams on ex vivo porcine corneal specimens at pulse durations between 480 fs and 9 ps. Cutting quality and bubble formation were characterized by scanning electron microscopy and macro photography. Results: With the vortex beam, the cuts were much smoother. Bubble formation was markedly reduced because cutting can be performed close to the bubble threshold, whereas with the Gaussian beam energies well above threshold are needed. Although the incident energy at the flap dissection threshold was slightly larger for the vortex beam, the absorbed energy was much smaller and contributed more effectively to cutting. This reduced plasma-induced pressure more than sevenfold. Conclusions: The vortex beam approach for corneal dissection is a simple, versatile, and cost-effective way of improving the precision of refractive surgery while reducing bubble formation and pressure-related mechanical side effects. Translational Relevance: Phase plates for propagation invariant vortex beams are easily implemented in the beam path of next-generation clinical devices.


Assuntos
Substância Própria , Procedimentos Cirúrgicos Refrativos , Animais , Córnea/cirurgia , Substância Própria/diagnóstico por imagem , Dissecação , Lasers , Suínos
3.
J Vis Exp ; (158)2020 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-32391812

RESUMO

Nd:YAG lasers have been used to perform noninvasive intraocular surgery, such as capsulotomy for several decades now. The incisive effect relies on the optical breakdown at the laser focus. Acoustic shock waves and cavitation bubbles are generated, causing tissue rupture. Bubble sizes and pressure amplitudes vary with pulse energy and position of the focal point. In this study, enucleated porcine eyes were positioned in front of a commercially available Nd:YAG laser. Variable pulse energies as well as different positions of the focal spots posterior to the cornea were tested. Resulting lesions were evaluated by two-photon microscopy and histology to determine the best parameters for an exclusive detachment of corneal endothelial cells (CEC) with minimum collateral damage. The advantages of this method are the precise ablation of CEC, reduced collateral damage, and above all, the non-contact treatment.


Assuntos
Perda de Células Endoteliais da Córnea/cirurgia , Animais , Modelos Animais de Doenças , Humanos , Terapia a Laser , Suínos
4.
J Biomed Opt ; 24(5): 1-7, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31124345

RESUMO

Correction of hyperopia requires an increase of the refractive power by steepening of the corneal surface. Present refractive surgical techniques based on corneal ablation (LASIK) or intrastromal lenticule extraction (SMILE) are problematic due to epithelial regrowth. Recently, it was shown that correction of low hyperopia can be achieved by implanting intracorneal inlays or allogeneic lenticules. We demonstrate a steepening of the anterior corneal surface after injection of a transparent, liquid filler material into a laser-dissected intrastromal pocket. We performed the study on ex-vivo porcine eyes. The increase of the refractive power was evaluated by optical coherence tomography (OCT). For a circular pocket, injection of 1 µl filler material increased the refractive power by +4.5 diopters. An astigmatism correction is possible when ellipsoidal intrastromal pockets are created. Injection of 2 µl filler material into an ellipsoidal pocket increased the refractive power by +10.9 dpt on the short and +5.1 dpt on the long axis. OCT will enable to monitor the refractive change during filler injection and is thus a promising technique for real-time dosimetry.


Assuntos
Astigmatismo/cirurgia , Córnea/fisiologia , Cirurgia da Córnea a Laser/métodos , Hiperopia/cirurgia , Tomografia de Coerência Óptica , Animais , Materiais Biocompatíveis , Córnea/cirurgia , Topografia da Córnea , Preenchedores Dérmicos/química , Ácido Hialurônico/química , Hidrogéis/química , Radiometria , Refração Ocular , Refratometria , Suínos , Raios Ultravioleta
5.
Biomed Opt Express ; 5(10): 3521-40, 2014 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-25360369

RESUMO

Gut mucosa is an important interface between body and environment. Immune response and healing processes of murine small intestinal mucosa were investigated by intravital time-lapse two-photon excited autofluorescence microscopy of the response to localized laser-induced damage. Epithelial lesions were created by 355-nm, 500-ps pulses from a microchip laser that produced minute cavitation bubbles. Size and dynamics of these bubbles were monitored using a novel interferometric backscattering technique with 80 nm resolution. Small bubbles (< 2.5 µm maximum radius) merely resulted in autofluorescence loss of the target cell. Larger bubbles (7-25 µm) affected several cells and provoked immigration of immune cells (polymorphonuclear leucocytes). Damaged cells were expelled into the lumen, and the epithelium healed within 2 hours by stretching and migration of adjacent epithelial cells.

6.
Invest Ophthalmol Vis Sci ; 54(13): 7854-64, 2013 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-24168991

RESUMO

PURPOSE: A new 355 nm UV laser was used for corneal flap cutting in an animal model and tested for clinical and morphologic alterations. METHODS: Corneal flaps were created (Chinchilla Bastards; n = 25) with an UV nanosecond laser at 355 nm (150 kHz, pulse duration 850 ps, spot-size 1 µm, spot spacing 6 × 6 µm, side cut Δz 1 µm; cutting depth 130 µm) and pulse energies of 2.2 or 2.5 µJ, respectively. Following slit-lamp examination, animals were killed at 6, 12, and 24 hours after treatment. Corneas were prepared for histology (hematoxylin and eosin [HE], TUNEL-assay) and evaluated statistically, followed by ultrastructural investigations. RESULTS: Laser treatment was tolerated well, flap lift was easier at 2.5 µJ compared with 2.2 µJ. Standard HE at 24 hours revealed intact epithelium in the horizontal cut, with similar increase in corneal thickness at both energies. Irrespective of energy levels, TUNEL assay revealed comparable numbers of apoptotic cells in the horizontal and vertical cut at 6, 12, and 24 hours, becoming detectable in the horizontal cut as an acellular stromal band at 24 hours. Ultrastructural analysis revealed regular morphology in the epi- and endothelium, while in the stroma, disorganized collagen lamellae were detectable representing the horizontal cut, again irrespective of energy levels applied. CONCLUSIONS: This new UV laser revealed no epi- nor endothelial damage at energies feasible for corneal flap cutting. Observed corneal swelling was lower compared with existing UV laser studies, albeit total energy applied here was much higher. Observed loss of stromal keratinocytes is comparable with available laser systems. Therefore, this new laser is suitable for refractive surgery, awaiting its test in a chronic environment.


Assuntos
Córnea/cirurgia , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Lasers de Excimer/uso terapêutico , Miopia/cirurgia , Retalhos Cirúrgicos , Animais , Apoptose , Contagem de Células , Córnea/patologia , Modelos Animais de Doenças , Epitélio Corneano/ultraestrutura , Marcação In Situ das Extremidades Cortadas , Microscopia Eletrônica de Transmissão , Miopia/patologia , Coelhos , Resultado do Tratamento
7.
Phys Rev Lett ; 100(3): 038102, 2008 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-18233040

RESUMO

We determined the bubble radius R_(max) for femtosecond optical breakdown in water at 347, 520, and 1040 nm with an unprecedented accuracy (+/-10 nm). At threshold, R_(max) was smaller than the diffraction-limited focus radius and ranged from 190 nm to 320 nm. The increase of R_(max) with laser energy E_(L) is slowest at 347 nm, providing optimum control of cell surgery. Experimental results agree with a model of bubble formation in heated and thermoelastically stretched liquids. Theory predicts a threshold temperature T_(th) approximately equal to 168 degrees C. For T>300 degrees C, a phase explosion sets in, and R_(max) increases rapidly with E_(L).


Assuntos
Lasers , Nanotecnologia/métodos , Frações Subcelulares/química , Água/química , Termodinâmica
8.
Opt Lett ; 31(12): 1812-4, 2006 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-16729079

RESUMO

We developed a modified Hoffman contrast technique with a 12 ns pulsed incoherent extended white-light source that enables an easily interpretable visualization of ablation plumes with high resolution, a large dynamic range, and color information. By comparison, a conventional dark-field setup with a slitlike laser light source provides large sensitivity but a small dynamic range, and it is difficult to interpret the filtered images.


Assuntos
Algoritmos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Terapia a Laser/métodos , Refratometria/métodos , Cirurgia Assistida por Computador/métodos , Imagens de Fantasmas , Refratometria/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...