Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Water Res ; 266: 122322, 2024 Aug 24.
Artigo em Inglês | MEDLINE | ID: mdl-39213680

RESUMO

Ultraviolet light-emitting diodes (UV-LEDs) have demonstrated the ability to inactivate microorganisms in water, offering an environmentally safer alternative to the conventional mercury lamp, in UV applications. While several studies have explored the microbiological effect of UVC-LEDs (200nm-280nm), limited information exists regarding their effects on waters with critical qualities. These critical qualities encompass bacteria, viruses, and protozoa - drinking water quality indicators defined by the World Health Organization for small water systems. For the first time, this work reports on the Escherichia coli, PhiX-174, MS2, and Cryptosporidium oocysts inactivation using a bench-scale UVC-LED (280 nm) water disinfection system. UV doses at a wavelength of 280 nm (UV280) of up to 143.4 mJ/cm2 were delivered under two quality-critical water conditions: filtered water (UV transmittance at 280 nm - UVT280 90.2 %) and WHO challenge water (UVT 15.7 %). Results revealed microbiological reductions dependent on exposure time and UVT. For UV280 dose of 16.1 mJ/cm2, 2.93-3.70 log E. coli reductions were observed in UVT 90.2 % and 15.7 %, 3.49-4.21 log for PhiX-174, 0.63-0.78 log for MS2, and 0.02-0.04 log for Cryptosporidium oocysts. Significantly higher UV280 doses of 143.4 mJ/cm2 led to reductions of 3.94-5.35 log for MS2 and 0.42-0.46 log for Cryptosporidium oocysts. Statistical analysis revealed that the sensitivity among the organisms to UV280 exposure was E. coli = PhiX-174 > MS2 >> Cryptosporidium oocysts. Although experiments with WHO challenge water posed greater challenges for achieving 1 log reduction compared to filtered water, this difference only proved statistically significant for PhiX-174 and MS2 reductions. Overall, UVC-LED technology demonstrated notable efficacy in microbiological inactivation, achieving significant reductions based on WHO scheme of evaluation for POU technologies in both bacteria and viruses even in critical-quality waters. The findings emphasize the potential for extending the application of UVC-LED as a viable solution for household water treatment.

2.
Artigo em Inglês | MEDLINE | ID: mdl-35452358

RESUMO

Safe drinking water' supply is an essential service and depends directly on the water treatment that produces water treatment sludge (WTS) as a product, whose final destination varies and remains a challenge. The ecotoxicity assessment of the WTS address the ecological implications of the WTS disposal but these information is still scarce in the literature. In this sense, we did a systematic review of the ecotoxicological studies on WTS using databases from six platforms. From the 785 papers recovered; 16 studies were eligible and showed the ecotoxicity assays' applicability to evaluate the WTS. We discussed WTS ecotoxicity considering sample characterization; terrestrial and aquatic toxicity assays; and WTS challenges. WTS proved to be a highly heterogeneous matrix composed mainly of coagulant precipitates, including Al and Fe. Studies lack consensus concerning the most representative/sensitive species for evaluating WTS' toxicity. Crustaceans were the most studied aquatic group, although algae species were more sensitive. Besides, soil ecotoxicity assessed only plant growth, and a single study used the earthworm. Even papers used bioassays to indicate the recycling WTS' feasibility, there is a lack of specific legislation regarding the WTS reuse. Furthermore, are necessary a regulation for WTS management that involves an ecological risk assessment.


Assuntos
Oligoquetos , Poluentes Químicos da Água , Purificação da Água , Animais , Biota , Ecotoxicologia , Esgotos , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/toxicidade
3.
Environ Technol ; 43(22): 3401-3413, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33890830

RESUMO

Household Water Treatment and Safe Storage (HWTS) are recommended to supply the demand for drinking water in communities without conventional water supply systems. However, there is a lack of long-term laboratory studies regarding such technologies. We evaluated the contributions of each step of a multi-barrier system with pretreatment (sedimentation and fabric filtration), filtration in Household Slow Sand Filters (HSSFs) and disinfection (sodium hypochlorite) treating surface water for more than 14 consecutive months. Removal of turbidity, colour, organic matter, coliform group bacteria and protozoa were evaluated. Two HSSF models were compared, one with a diffuser vessel (HSSF-d) and one with a gravity float equipped vessel (HSSF-f). Correlations between efficiency and operational parameters were assessed. Overall, the multi-barrier system removed more than 90% of turbidity and more than 3.5 log of Escherichia coli. HSSF removed up to 3.0 log of Giardia spp. and 2.4 log of Cryptosporidium spp. HSSF-f presented significantly higher removal rates for turbidity, apparent colour and E. coli. Disinfection resulted in water with E. coli concentration lower than 1 CFU 100mL-1, however it was not able to inactivate protozoa. The evaluated system was able to reduce microbiological risks from water and could indeed be an alternative to communities that depend on surface water as their main source of supply. Nevertheless, further studies are recommended to include a low-cost disinfectant for protozoa inactivation.


Assuntos
Criptosporidiose , Cryptosporidium , Purificação da Água , Escherichia coli , Filtração , Purificação da Água/métodos , Abastecimento de Água
4.
Environ Technol ; 43(10): 1583-1592, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33092473

RESUMO

This study aimed to evaluate the efficiency of four household slow sand filter (HSSF) models for the removal of microorganisms from river water throughout the development of their biological layers (schmutzdecke). Two models were designed to be operated continuously (HSSF-CC and HSSF-CT) and two intermittently (HSSF-ID and HSSF-IF). Filters were fed daily with 48 L pre-treated river water (24 h sedimentation followed by filtration through a non-woven synthetic blanket). Water samples were quantified by coliform group bacteria and analysed by bright field microscopy to visualize the microorganisms. Total coliform reduction was between 1.42 ± 0.59 log and 2.96 ± 0.58 log, with continuous models showing a better performance (p-values < 0.004). Escherichia coli reduction varied from 1.49 ± 0.58 log to 2.09 ± 0.66 log and HSSF-IF, HSSF-CC and HSSF-CT presented a similar performance (p-values > 0.06), slightly better than the one presented by HSSF-ID (p-value=0.04). Microorganisms, such as algae, protozoa and helminths were detected by microscopy in raw water and pre-treated water. Algae were the most significant group in these samples, although they were not visualized by bright field microscopy in the filtered water. Results showed the potential of HSSF in microbiological risk reduction from river water, which increases the range of point-of-use water treatments in rural communities. However, additional studies of the HSSF biological layer must be performed.


Assuntos
Rios , Purificação da Água , Escherichia coli , Características da Família , Filtração/métodos , Água Doce , Dióxido de Silício , Purificação da Água/métodos
5.
J Environ Manage ; 288: 112412, 2021 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-33823447

RESUMO

This study evaluated the impact of a 50% reduction of filter media depth in Household Slow Sand Filters (HSSFs) on continuous flow to remove physicochemical and microbiological parameters from river water. Furthermore, simple pre-treatment and disinfection processes were evaluated as additional treatments. Two filter models with different filtration layer depths were evaluated: a traditional one with 50 cm media depth (T-HSSF) and a compact one (C-HSSF) with 25 cm. HSSFs were fed with pre-treated river water (24-h water sedimentation followed by synthetic fabric filtration) for 436 days at a constant filtration rate of 0.90 m3 m-2 day-1 with a daily production of 48 L day-1. Sodium hypochlorite (2.0 mg L-1 of NaOCl 2.5% for 30 min) was used to disinfect the filtered water. Water samples were analysed weekly for parameters such as turbidity, organic matter, colour and E. coli, among others. Removal of protozoan cysts and oocysts by the HSSFs were also evaluated. After pretreatment, turbidity from the HSSF river water was reduced to 13.2 ± 14.6 NTU, allowing the filters to operate. Statistical analysis indicated no significant difference (p > 0.05) between T-HSSF and C-HSSF efficiencies in all evaluated parameters throughout operation time. Hence, media depth reduction did not hinder continuous HSSF performance for almost all the evaluated parameters. However, it may have affected Giardia cysts retaining, which passed through the thinner media on one evaluation day. Disinfection was effective in reducing remaining bacteria from filtered water; however, it was ineffective to inactivate protozoa. The reduction in the filtration layer did not affect the overall filtered water quality or quantity showing that a compact HSSF model may be a viable option for decentralized water treatment.


Assuntos
Areia , Purificação da Água , Escherichia coli , Características da Família , Filtração , Dióxido de Silício
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA